Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – EquipmentType Company name: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address: A2 2F BUILDING ENET NEW INDUSTRIAL PARK,DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA SHENZHEN, 518XXX China Product Name: Smart Phone FCC ID: 2ANMUC17 Model(s): C17 Plus, C17 S, C17 E, C17 Pro, C17, C17 Ultra, C17 MAX, C17 GT, C17 4G 2.911(d)(5)(i) EquipmentType We, [SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD ] (“the applicant”) certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: Gaolei Yan Date: 8/11/2026 Title and Company name: Manager / SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1)986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD 2.911 (d)(5)(ii) Applicant Attestation v1.3 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address: A2 2F BUILDING ENET NEW INDUSTRIAL PARK,DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA SHENZHEN, 518XXX China Product Name: Smart Phone FCC ID: 2ANMUC17 Model(s): C17 Plus, C17 S, C17 E, C17 Pro, C17, C17 Ultra, C17 MAX, C17 GT, C17 4G 2.911(d)(5)(ii) Applicant filing We, [SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 ,established pursuant to §1.50002 of this chapter,as an entity producing coveredcommunications equipment. Yours sincerely, Name: Gaolei Yan Date: 8/11/2026 Title and Company name: Manager / SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1)986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
(SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD) U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTENTION: FCC C ertification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name: Baihetian Innovative Solutions FRN: 0033401605 Contact Name: Kenneth Young Street Address: 6837 Chase Rd City/Province/Zip: Dearborn, MI 48126 Telephone No: 313-395-3113 Email: [email protected] This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of t he Applicant noted below. U.S. Agent Signature: Date: April 22, 2024 Signed by (Printed Name/Title): Kenneth Young/ Manager The Applicant acknowledges th at th ey must maintain an agent for no less than on e year aft er terminating all marketing and importation OR th e conclusion of any Commission-r elated proceeding involving the equipment. The appli ca nt fu rth er acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Grantee Code: 2ANMU FCC ID:2ANMUC17 Contact Name: Gaolei Yan StreetAddress:A2 2F BUILDINGENET NEW INDUSTRIALPARK, DAFUINDUSTRIAL ZONE, GUANLAN, LONGHUA City/Province/Zip: SHENZHEN,China Telephone No: 0755-61156588 Email: [email protected] Applicant Signature: Date:2026.7.25 Signed by (Printed Name/Title) : Gaolei Yan/ Manager
SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Family models difference declaration Product name: Smart Phone Model No.: C17 Plus Family Model: C17 S, C17 E, C17 Pro, C17, C17 Ultra, C17 MAX, C17 GT, C17 4G FCC ID: 2ANMUC17 Difference declaration: All models are the same circuit and RF module, except for model names. Regards, Signature Gaolei Yan / Manager Date/City: Phone: Fax: E-mail: 2026-08-11/ Shenzhen 0755-61156588 0755-61156588 [email protected]
SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2026/07/25 Subject; Request for Confidentiality FCC ID: 2ANMUC17 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description SOFTWARE SECURITY REQUIREMENTS FOR U-NII DEVICES Tune up In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Gaolei Yan Title: Manager Email: [email protected]
Letter of Authorization Company name: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address: A2 2F BUILDING ENET NEW INDUSTRIAL PARK,DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA SHENZHEN, 518XXX China Product Name: Smart Phone FCC ID: 2ANMUC17 Model(s): C17 Plus, C17 S, C17 E, C17 Pro, C17, C17 Ultra, C17 MAX, C17 GT, C17 4G We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: Gaolei Yan Date: 2026-08-11 Title: Manager Signature of applicant:
ATTACHMENT PHOTOGRAPHS OF EXT Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6 Photo 7 Photo 8 Photo 9 Photo 10
size:40*30mm Label location
Page 1 of 262 Report No.: N26042809821E FCC SAR EVALUATION REPORT In accordance with the requirements of FCC 47 CFR Part 2(2.1093) and IEEE Std 1528-2013 Product Name: Smart Phone Brand Name: OUKITEL Model Name: C17 Plus Family Model: C17 S, C17 E, C17 Pro, C17, C17 Ultra, C17 MAX, C17 GT, C17 4G Report No.: N26042809821E FCC ID: 2ANMUC17 Prepared for SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN,LONGHUA SHENZHEN, 518XXX China Prepared by Shenzhen NTEK Testing Technology Co., Ltd. No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China Tel. 0755-23200050 Website: http://www.ntek.org.cn Page 2 of 262 Report No.: N26042809821E TEST RESULT CERTIFICATION Applicant’s name ................. : SHENZHENYUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address .................................. : A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN,LONGHUA SHENZHEN, 518XXX China Manufacturer's Name .......... : SHENZHENYUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address .................................. : A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN,LONGHUA SHENZHEN, 518XXX China Product description Product name ........................ : Smart Phone Brand Name ......................... : OUKITEL Model and/or type reference .............................. : C17 Plus Family Model.......................... : C17 S, C17 E, C17 Pro, C17, C17 Ultra, C17 MAX, C17 GT, C17 4G Standards ............................. : FCC 47 CFR Part 2(2.1093) IEEE Std 1528-2013 Published RF exposure KDB procedures This device described above has been tested by Shenzhen NTEK. In accordance with the measurement methods and procedures specified in IEEE Std 1528-2013 and KDB 865664 D01. Testing has shown that this device is capable of compliance with localized specific absorption rate (SAR) specified in FCC 47 CFR Part 2(2.1093). The test results in this report apply only to the tested sample of the stated device/equipment. Other similar device/equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. This report shall not be reproduced except in full, without the written approval of Shenzhen NTEK, this document may be altered or revised by Shenzhen NTEK, personal only, and shall be noted in the revision of the document. Test Sample Number ............................ S2605070382-1# Date of Test Date (s) of performance of tests ............. : May. 11, 2026~ May. 26, 2026 Date of Issue .......................................... : Jun. 23, 2026 Test Result .............................................. : Pass Prepared By : Reviewed By : Approved By : Owen Xiao (Project Engineer) Aaron Cheng (Supervisor) Alex Li (Manager) Page 3 of 262 Report No.: N26042809821E ※ ※ Revision History ※ ※ REV. DESCRIPTION ISSUED DATE REMARK Rev.1.0 Initial Test Report Release Jun. 23, 2026 Owen Xiao Page 4 of 262 Report No.: N26042809821E TABLE OF CONTENTS 1. General Information ............................................................................................ 6 1.1. RF exposure limits .................................................................................... 6 1.2. Statement of Compliance ........................................................................ 7 1.3. EUT Description ....................................................................................... 7 1.4. Test specification(s) .................................................................................. 9 1.5. Ambient Condition ................................................................................... 9 1.6. Facilities And Accreditations .................................................................... 9 1.6.1. Facilities ............................................................................................. 9 1.6.2. Laboratory Accreditations And Listings .............................................. 9 2. SAR Measurement System ................................................................................. 10 2.1. SATIMO SAR Measurement Set-up Diagram .......................................... 10 2.2. Robot ..................................................................................................... 11 2.3. E-Field Probe .......................................................................................... 12 2.3.1. E-Field Probe Calibration ................................................................. 12 2.4. SAM phantoms ...................................................................................... 13 2.4.1. Technical Data .................................................................................. 14 2.5. Device Holder ........................................................................................ 15 2.6. Test Equipment List ................................................................................ 16 3. SAR Measurement Procedures .......................................................................... 19 3.1. Power Reference ................................................................................... 19 3.2. Area scan & Zoom scan .......................................................................... 19 3.3. Description of interpolation/extrapolation scheme .............................. 21 3.4. Volumetric Scan ..................................................................................... 21 3.5. Power Drift ............................................................................................ 21 4. System Verification Procedure .......................................................................... 22 4.1. Tissue Verification ................................................................................. 22 4.1.1. Tissue Dielectric Parameter Check Results ...................................... 23 4.2. System Verification Procedure ...…
Text truncated - open the document above for the full version.
Page 211 of 262 Report No.: N26042809821E Page 212 of 262 Report No.: N26042809821E Page 213 of 262 Report No.: N26042809821E Page 214 of 262 Report No.: N26042809821E Page 215 of 262 Report No.: N26042809821E Page 216 of 262 Report No.: N26042809821E Page 217 of 262 Report No.: N26042809821E Page 218 of 262 Report No.: N26042809821E Page 219 of 262 Report No.: N26042809821E Page 220 of 262 Report No.: N26042809821E Page 221 of 262 Report No.: N26042809821E Page 222 of 262 Report No.: N26042809821E Page 223 of 262 Report No.: N26042809821E Page 224 of 262 Report No.: N26042809821E Page 225 of 262 Report No.: N26042809821E Page 226 of 262 Report No.: N26042809821E Page 227 of 262 Report No.: N26042809821E Page 228 of 262 Report No.: N26042809821E Page 229 of 262 Report No.: N26042809821E Page 230 of 262 Report No.: N26042809821E Page 231 of 262 Report No.: N26042809821E Page 232 of 262 Report No.: N26042809821E Page 233 of 262 Report No.: N26042809821E Page 234 of 262 Report No.: N26042809821E Page 235 of 262 Report No.: N26042809821E Page 236 of 262 Report No.: N26042809821E Page 237 of 262 Report No.: N26042809821E Page 238 of 262 Report No.: N26042809821E Page 239 of 262 Report No.: N26042809821E Page 240 of 262 Report No.: N26042809821E Page 241 of 262 Report No.: N26042809821E Page 242 of 262 Report No.: N26042809821E Page 243 of 262 Report No.: N26042809821E Page 244 of 262 Report No.: N26042809821E Page 245 of 262 Report No.: N26042809821E Page 246 of 262 Report No.: N26042809821E Page 247 of 262 Report No.: N26042809821E Page 248 of 262 Report No.: N26042809821E Page 249 of 262 Report No.: N26042809821E Page 250 of 262 Report No.: N26042809821E Page 251 of 262 Report No.: N26042809821E Page 252 of 262 Report No.: N26042809821E Page 253 of 262 Report No.: N26042809821E Page 254 of 262 Report No.: N26042809821E Page 255 of 262 Report No.: N26042809821E <Justification of the extended calibration> If dipoles are verified in return loss (<-20dB, within 20% of prior calibration for below 3GHz, and <-8dB, within 20% of prior calibration for 5GHz to 6GHz), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. <Head 750MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -29.875 - 52.798 - Feb. 13, 2025 -27.437 8.16 49.256 3.542 Feb. 10, 2026 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 256 of 262 Report No.: N26042809821E <Head 835MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -46.216 - 51.571 - Feb. 13, 2025 -46.314 0.212 48.792 2.779 Feb. 10, 2026 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 257 of 262 Report No.: N26042809821E <Head 1800MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -25.579 - 44.876 - Feb. 13, 2025 -25.140 1.716 48.510 3.634 Feb. 10, 2026 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 258 of 262 Report No.: N26042809821E <Head 1900MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -27.206 - 46.948 - Feb. 13, 2025 -28.057 3.128 45.249 1.699 Feb. 10, 2026 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 259 of 262 Report No.: N26042809821E <Head 2450MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -25.738 - 55.969 - Feb. 13, 2025 -26.659 3.578 54.323 1.646 Feb. 10, 2026 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 260 of 262 Report No.: N26042809821E <Head 2600MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -23.352 - 55.439 - Feb. 13, 2025 -23.058 1.259 57.024 1.585 Feb. 10, 2026 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data
Antenna test data report Customer: Yunji Project: S208 GSM: B2/B3/B5/B8 WCDMA: B1/B2/B4/B5/B8 TDD:B34/38/B39/B40/B41 FDD:B1/B2/B3/B4/B5/B7/B8/B12/B13/B17/B18/B19/B20/B25/B26/B28AB/ B66 Engineer:xiong (187 1893 6792) Date:2026-07-22 Shenzhen Ruixinda Communication Equipment Co., Ltd Address: Room 503, Building 211, Tairan Ninth Road, Tairan Industrial Zone, Chegongmiao, Futian District, Shenzhen 1. Test Project 2.Test Equipment Agilent 5071B (S Parameter(RL/VSWR)Test Equipment) Test Project Equipment 1. S Parameter 1. Return Loss(RL) 2. VSWR Network Analyzer: Agilent 5071B 2. RF Test (2/3/4G) 1. power 2. level 3.TRP/TIS Comprehensive Test: SP9500/CMW500/8960 Test Environment: Anechoic Chamber SP9500 (5GTest Equipment) Agilent 8960 (2G/3G Test Equipment) CMW 500 (2G/3G/4GTest Equipment) 3.TestEnvironment Microwave Anechoic Chamber 4.Test Steps Passive VSWR/RL Test Steps: 50Ω Coaxial Cable 100mm Length Copper Pipe 5071B Network Analyzer Test Fixture Active TRP/TIS Test Steps: Open Computer OTA Test Software Open Turntable Switch And Reset To zero Open 8960/CMW500 Test Equipment Test mobile phone insert test SIM card and Put into the microwave darkroom to connect OTA Software automatic testing Output Data 5.Antenna Gain Band Max Gain Band Max Gain GSM850 -0.35 LTE-B1 -0.30 GSM900 -0.41 LTE-B2 -0.28 DCS1800 -0.17 LTE-B3 -0.17 PCS1900 -0.28 LTE-B4 -0.32 WCDMA1 -0.30 LTE-B5 -0.35 WCDMA2 -0.28 LTE-B7 -0.22 WCDMA4 -0.32 LTE-B8 -0.41 WCDMA5 -0.35 LTE-B12 -0.90 WCDMA8 -0.41 LTE-B17 -0.90 LTE-B18 -0.35 LTE-B19 -0.35 LTE-B20 -0.35 LTE-B25 -0.28 LTE-B26 -0.35 LTE-B28 -0.95 LTE-B66 -0.32 LTE-B34 -0.30 Bluetooth 0.11 LTE-B38 -0.22 WIFI-2.4G 0.11 LTE-B39 -0.28 WIFI-5.8G -0.44 LTE-B40 -0.37 GPS -0.10 LTE-B41 -0.22 6.3D Lobe Diagram GPS BT/2.4G-WIFI 5.1G-WIFI 5.8G-WIFI NFC Physical parameters of antenna body physical properties size W 0.5mm G 0.5mm T 0.04mm N 3.6 SIZE 40mm*30mm 7 Mechanical drawing 8.Introduction to Antenna Information S208 Antenna type and frequency band MAIN ANTENNA(PIFA):2G/3G/4G DIV ANTENNA(PIFA):2G/3G/4G GPS/WIFI/BT ANTENNA(PIFA):L1/2.4G-5.1-5.8 WIFI/BT/NFC Antenna materia FPC
Page 1 of 27 Report No.: N26042809833E ` FCC RADIO TEST REPORT FCC ID: 2ANMUC17 Product: Smart phone Trade Mark: OUKITEL Model Name: C17 Plus Family Model: C17 S, C17 E, C17 Pro, C17, C17 Ultra, C17 MAX, C17 GT, C17 4G Report No.: N26042809833E Issue Date: Jul. 07, 2026 Prepared for SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN,LONGHUA SHENZHEN, 518XXX China Prepared by Shenzhen NTEK Testing Technology Co., Ltd. No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China Tel. 0755-23200050 Website: http://www.ntek.org.cn Page 2 of 27 Report No.: N26042809833E ` TEST RESULT CERTIFICATION Applicant’s name ................. : SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address ................................. : A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN,LONGHUA SHENZHEN, 518XXX China Manufacturer's Name .......... : SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address ................................. : A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN,LONGHUA SHENZHEN, 518XXX China Product description Product name ........................... : Smart phone Model and/or type reference : C17 Plus Family Model ......................... : C17 S, C17 E, C17 Pro, C17, C17 Ultra, C17 MAX, C17 GT, C17 4G Test Sample number .............. : S2605070381-1# Standards ............................. : FCC Part15.225 Test procedure ............................... : ANSI C63.10-2020+Cor 1-2023 This device described above has been tested by NTEK, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of NTEK, this document may be altered or revised by NTEK, personnel only, and shall be noted in the revision of the document. Date of Test ............................................ : Date (s) of performance of tests ............. : May. 12, 2026 ~ Jul. 07, 2026 Date of Issue ........................................... : Jul. 07, 2026 Test Result ............................................... : Pass Prepared By : Reviewed By : Approved By : Mary Hu (Project Engineer) Aaron Cheng (Supervisor) Alex Li (Manager) Page 3 of 27 Report No.: N26042809833E ` Table of Contents Page 1 . SUMMARY OF TEST RESULTS 4 1.1 TEST FACILITY 5 1.2 MEASUREMENT UNCERTAINTY 5 2 . GENERAL INFORMATION 6 2.1 GENERAL DESCRIPTION OF EUT 6 2.2 DESCRIPTION OF TEST MODES 7 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 8 2.4 DESCRIPTION OF SUPPORT UNITS (CONDUCTED MODE) 9 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 10 3 . ANTENNA REQUIREMENT 11 3.1 STANDARD REQUIREMENT 11 3.2 EUT ANTENNA 11 4 . EMC EMISSION TEST 12 4.1 CONDUCTED EMISSION MEASUREMENT 12 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 12 4.1.2 TEST CONFIGURATION 12 4.1.3 TEST PROCEDURE 12 4.1.4 TEST RESULT 13 4.2 RADIATED EMISSION MEASUREMENT 15 4.2.1 RADIATED EMISSION LIMITS 15 4.2.2 TEST PROCEDURE 16 4.2.3 DEVIATION FROM TEST STANDARD 16 4.2.4 TEST SETUP 17 4.2.5 TEST RESULTS (BELOW 30MHZ) 18 4.2.6 TEST RESULTS (BETWEEN 30 – 1000 MHZ) 22 5 . BANDWIDTH TEST 24 5.1 TEST PROCEDURE 24 5.2 DEVIATION FROM STANDARD 24 5.3 TEST SETUP 24 5.4 TEST RESULTS 25 6. FREQUENCY TOLERANCE 26 Page 4 of 27 Report No.: N26042809833E ` 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15, Subpart C (15.225) Standard Section Test Item Judgment Remark 15.207 Conducted Emission Pass 15.205(a) 15.209 15.225(abcd) Radiated Spurious Emission Pass 15.225 15.215(c) 20dB Bandwidth Pass 15.225(e) Frequency Tolerance Pass 15.203 Antenna Requirement Pass NOTE: (1) ” N/A” denotes test is not applicable in this Test Report. Page 5 of 27 Report No.: N26042809833E ` 1.1 TEST FACILITY All measurement facilities used to collect the measurement data are located at No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China. The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.10 and CISPR Publication 22. Site Description CNAS-Lab. : The Certificate Registration Number is L5516. IC-Registration The Certificate Registration Number is 9270A. CAB identifier:CN0074 FCC- Accredited Test Firm Registration Number: 463705. Designation Number: CN1184 A2LA-Lab. The Certificate Registration Number is 4298.01 This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Name of Firm : Shenzhen NTEK Testing Technology Co., Ltd. Site Location : No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China. 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±1.38dB 2 RF power,conducted ±0.16dB 3 Spurious emissions,conducted ±0.21dB 4 All emissions,radiated(<1G) ±4.68dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% Page 6 of 27 Report No.: N26042809833E ` 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Equipment Smart phone Trade Mark OUKITEL Model Name C17 Plus Family Model C17 S, C17 E, C17 Pro, C17, C17 Ultra, C17 MAX, C17 GT, C17 4G Model Difference All models are the same circuit and RF module, except for model names. Product Description The EUT is a Smart phone Operat…
Text truncated - open the document above for the full version.
6837 Chase Rd · Dearborn, Michigan, 48126 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |