FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Contrinex AG/
  3. 2ANZQ-RFC23HF

2ANZQ-RFC23HFRLH-C23TA-NHV

Contrinex AG
RLH-C23TA-NHV - FCC ID 2ANZQ-RFC23HF - Contrinex AG
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Sep 04, 2026
Application Purpose
Original Equipment
Equipment Note
RLH-C23TA-NHV
Frequency Range
13.56000000 - 13.56000000
Company
Contrinex AG
Country
Switzerland

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

HF RFID SYSTEM READ/WRITE MODULES (RWM) CONTRINEX AG Industrial Electronics Route du Pâqui 3 – P.O. Box – CH 1720 Corminboeuf – Switzerland – Tel: +41 26 460 46 46 Fax: +41 26 460 46 40 – Internet: www.contrinex.com – E-mail: [email protected] 1 HOUSINGREAD/WRITE DISTANCE 920x32 mm plastic housing (C23) 9Metal threaded housing (M18, M30) 9Sensing face of PBTP 9Insensitive to dirt 9IO-Link V1.1.3 92× PNP output in SIO mode configurable 9IP 68/69K (C44, C23, C88) M18 M30 C44 C23 C88 34 mm 50 mm 78 mm 36 mm 120mm RLH-xxxxA-NHx PICTURES T.B.D. RLH-C23TA-NHV-224 RLH-C88TA-NHS RLH-M18PA-NHS RLH-M30PA-NHS RLH-C44PA-NHS CONTRINEX AG Industrial Electronics Route du Pâqui 3 – P.O. Box – CH 1720 Corminboeuf – Switzerland – Tel: +41 26 460 46 46 Fax: +41 26 460 46 40 – Internet: www.contrinex.com – E-mail: [email protected] 2 GENERAL DATAINTERFACE Carrier frequency13.56 MHzData transfer rate230,400 baud Compatible standardISO 15693 1 LEDsSee “LED status” on p. 3 Maximum transmission speed26.5 kbit/sIO-Link 9 Maximum field strength (at 3 m/30 m) RLH-M18PA-NHS: 45.4 / 4.6 dBμV/m RLH-M30PA-NHS: 55.1 / 14.9 dBμV/m RLH-C44PA-NHS: 66.7 / 26.4 dBμV/m RLH-C23TA-NHV-224: TBD / TBD dbμV/m RLH-C88TA-NHS: TBD / TBD dbμV/m MTTF (@ 40°C)TBD Read-write distance max. (RSSI ≥ 0) with ∅∅ 50 mm transponder RLH-M18PA-NHS: 34 mm RLH-M30PA-NHS: 50 mm RLH-C44PA-NHS: 78 mm RLH-C23TA-NHV-224: 36 mm LH-C88TA-NHS: 120 mm 1 Protocol anti-collision excluded. A maximum of one transponder can be detected at a time by the RWM, otherwise “TAGCommError” is reported ELECTRICAL DATAMECHANICAL DATA Supply voltage range (Ub) 11 ... 32 VDC Sensing face materialPBTP Max. current consumption (no load)≤ 50 mAAmbient temperature range TA 2 −25 ... +80°C Max. output current ≤ 200 mA (RLH-C23TA-NHV-244: ≤ 100 mA) Storage temperature range TS 3 −25 ... +80°C Short-circuit protection 9 Housing materialSee table “Available types” (p. 2) Voltage reversal protection 9 Enclosure ratingSee table “Available types” (p. 2) Cable length max.≤ 20 m Max. tightening torque RLH-M18PA-NHS: 25 Nm RLH-M30PA-NHS: 70 Nm RLH-C44PA-NHS: 0.6 Nm 4 RLH-C23TA-NHV-224: 0.25 Nm 5 RLH-C88TA-NHS: 2 Nm Weight (incl. nuts) See table “Available types” (p. 2) 2 Read/write operations possible 3 Data retention and mechanical stability limit 4 (on M12 connector) 5 (on M3 screw) CONTRINEX AG Industrial Electronics Route du Pâqui 3 – P.O. Box – CH 1720 Corminboeuf – Switzerland – Tel: +41 26 460 46 46 Fax: +41 26 460 46 40 – Internet: www.contrinex.com – E-mail: [email protected] 3 MOUNTING RECOMMENDATIONS CLEARANCE Read/write modules must not mutually influence each other. For this reason, a minimum distance of b between the devices must be observed. PIN ASSIGNMENT 3 1 4 2 SIO L+ L- 0V 24V C/Q1 Q2 SIO A : unique transponder zone B : sensing face C : support [mm]RLH-C44PA-NHSRLH-C23TA-NHV-224 RLH-C88TA-NHS a 6045180 b 12090360 c12090360 d 10845 IO-LINK CHARACTERISTICSVALUE Vendor ID0x0156 Device ID0xAB0600 IO-Link Protocol1.1.3 SIO-ModeSupported Process data32 bytes input / 32 bytes output Baudrate COM3 (230.4 kBaud) Minimum cycle time 10 ms Supported Access Locks Parameter: no, Data Storage: yes, Local Parameterization: no, Local User Interface: no Sub Index AccessNo sub index addressing possible except otherwise specified IODD files may be downloaded from https://www.contrinex.com/collections/rfid Select the product name to display the product page with corresponding downloads. Alternatively, just click/scan the QR code on the left. [mm]RLH-M18PA-NHSRLH-M30PA-NHS a3045 b5490 c6090 d1010 AVAILABLE TYPES Part numberPart reference Sensing faceHousing materialMountingEnclosure ratingConnection Weight 720-100-224RLH-M18PA-NHS ∅ 18 Chrome-plated brassNon-embeddable IP67 M12 4-pin37 g 720-100-225RLH-M30PA-NHS ∅ 30 Chrome-plated brassNon-embeddable IP67 M12 4-pin87 g 720-100-226RLH-C44PA-NHS 40×40 mmPBTPNon-embeddableIP68 & IP69KM12 4-pin105 g 720-100-229RLH-C23TA-NHV-224 32 x 20 mmPBTPNon-embeddableIP67 PUR 0,3m+M12 4-pin 19 g 720-100-228RLH-C88TA-NHS 80 x 80 mmPBTPNon-embeddableIP67M12 4-pin256 g CONTRINEX AG Industrial Electronics Route du Pâqui 3 – P.O. Box – CH 1720 Corminboeuf – Switzerland – Tel: +41 26 460 46 46 Fax: +41 26 460 46 40 – Internet: www.contrinex.com – E-mail: [email protected] 4 POSSIBLE COMBINATION AND TYPICAL DISTANCE (RSSI ≥ 1) RLH-M18PA-NHSRLH-M30PA-NHSRLH-C44PA-NHS Transponder typeS max [mm]S 0 [mm]D 0 [mm]S max [mm]S 0 [mm]D 0 [mm]S max [mm]S 0 [mm]D 0 [mm] ∅∅ 9 RTP-0090-020113.515175.52424932 ∅∅ 9 RTH-D09RA-NF0113.515175.52424932 ∅∅ 16 RTP-0160-020198.522281331402044 ∅∅ 16 RTH-D16RA-NF0198.522281331402044 ∅∅ 20 RTH-D20QA-ND0176212611.531381742 ∅∅ 20 RTH-D20QA-NF018821261230401844 ∅∅ 26 RTP-0263-02015421331536381744 ∅∅ 30 RTH-D30QA-ND019528341538462352 ∅∅ 30 RTH-D30QA-NF022928301338442148 ∅∅ 50 RTH-D50QA-ND020044441854582666 ∅∅ 50 RTH-D50QA-NF024642461954643268 ∅∅ 50 RTP-0502-022341042502354784180 ∅∅ 50 RTP-0502-06220439462052462052 RLH-C88TA-NHSRLH-C23TA-NHV-224 Transponder typeS max [mm]S 0 [mm]D 0 [mm]S max [mm]S 0 [mm]D 0 [mm] ∅∅ 30 RTH-D30QA-NDO804090273014 ∅∅ 30 RTP-0301-0209045100tbdtbdtbd ∅∅ 30 RTH-D30QA-NCO603075273014 ∅∅ 50 RTP-0502-02212060120364020 D 0 S 0 x y S max Read/Write Module Working area when RSSI ≥ 1 Transponder RLH-M30PA-NHS D 0 S 0 x y S max Read/Write Module Working area when RSSI ≥ 1 Transponder RLH-M18PA-NHS OUTPUT POWER D 0 S 0 x S max Model: RLS- C44P A-NxS Made by Contrinex y Read/Write Module Working area when RSSI ≥ 1 Transponder RLH-C44PA-NHS D 0 S 0 x y S max Read/Write Module Working area when RSSI ≥ 1 Transponder RLH-C88TA-NHS D 0 S 0 x y S max Read/Write Module Working area when RSSI ≥ 1 Transponder RLH-C23TA-NHV-224 CONTRINEX AG Industrial Electronics Route du Pâqui 3 – P.O. Box – CH 1720 Corminboeuf – Switzerland – Tel: +41 26 460 46 46 Fax: +41 26 460 46 40 – Internet: www.contrinex.com – E-mail: [email protected] 5 LED STATUS S TAG 1 23 4 This LED is yellow OR green Yellow condition dominates green 1: Tag RSSI leve…

Text truncated - open the document above for the full version.

Attestation Statements

Contrinex AG Rev 2026-04-24 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 07-13-2026 Ref: Attestation Statements Part 2.911(d)(5)(i) and Part 2.911(d)(5)(ii) FCC ID: 2ANZQ-RFC23HF Part 2.911(d)(5)(i) [Contrinex AG] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment and does not contain anti-virus software or cybersecurity software prohibited from receiving an equipment authorization pursuant to 47 CFR 2.903, KDB 986446 D01 Covered Equipment Guidance, and FCC Covered List (www.fcc.gov/supplychain/coveredlist). Part 2.911(d)(5)(ii) [Contrinex AG] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) (David Bachmann)

Attestation Statements

Contrinex AG Declaration of Conformity Federal Communications Commission Authorization and Evaluation Division F F C C C C I I D D : : 2 2 A A N N Z Z Q Q - - R R F F C C 2 2 3 3 H H F F Please be notified that we, the undersigned, C C o o n n t t r r i i n n e e x x A A G G declares that the product which bears the above FCC ID is also compliant with the FCC requirements for sDOC. And the sDOC procedure shall be carried out prior to marketing the device in the US. Sincerely, _________________ Name: David Bachmann Title: SR Manager, R&D Email: [email protected] Date:2026/7/13

Cover Letter(s)

Contrinex AG Confidentiality Request Letter Federal Communications Commission Authorization and Evaluation Division FCC ID: 2ANZQ-RFC23HF Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: 1. Block Diagram 2. Schematics 3. Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, _________________ Name: David Bachmann Title: SR Manager, R&D Email: [email protected] Date: 2026/07/13

Cover Letter(s)

Contrinex AG Declaration of Authorization We Name: Contrinex AG Address: Route du paqui 3 Corminboeuf FR 1720 Switzerland Declare that: Name Representative of agent: Marlin Chen Agent Company name: MRT Technology (Suzhou) Co., Ltd Address: D8 Building, Youxin Industrial Park, No.2 Tian'edang Rd., Wuzhong Economic Development Zone City: Suzhou Country: China is authorized to apply for Certification of the following product(s): Product: RLH-C23TA-NHV FCC ID: 2ANZQ-RFC23HF Model No.: RLH-C23TA-NHV-224 Sincerely, ________________ Name: David Bachmann Title: SR Manager, R&D Email: [email protected] Date:2026/07/13

Cover Letter(s)

Contrinex AG Justification Statement Federal Communications Commission Authorization and Evaluation Division FCC ID: 2ANZQ-RFC23HF Please be notified that we, the undersigned, Contrinex AG state that all measurements were performed radiated and therefore additional antenna gain documentation is not required. Sincerely, _________________ Name: David Bachmann Title: SR Manager, R&D Email: [email protected] Date:2026/07/13

External Photos

Report No.: 2606TW0125-UE 1 of 4 External Photograph (1) EUT Photo (2) EUT Photo Report No.: 2606TW0125-UE 2 of 4 (3) EUT Photo (4) EUT Photo Report No.: 2606TW0125-UE 3 of 4 (5) EUT Photo (6) EUT Photo Report No.: 2606TW0125-UE 4 of 4 (7) EUT Photo

Internal Photos

Report No.: 2606TW0125-UI 1 of 4 Internal Photograph (1) EUT Photo (2) EUT Photo Report No.: 2606TW0125-UI 2 of 4 (3) EUT Photo (4) EUT Photo Report No.: 2606TW0125-UI 3 of 4 (5) EUT Photo (6) EUT Photo Report No.: 2606TW0125-UI 4 of 4 (7) EUT Photo

RF Exposure Info

MRT Technology (Taiwan) Co., Ltd Report No.: 2606TW0125-U3 Phone: +886-3-3288388 Report Version: V1.0 Web: www.mrt-cert.com Issue Date: 2026-07-31 Page Number: 1 of 7 RF Exposure Evaluation FCC ID : 2ANZQ-RFC23HF Applicant : Contrinex AG Application Type : Certification Product : RLH-C23TA-NHV Model No. : RLH-C23TA-NHV-224 Brand Name : Contrinex FCC Rule Part(s) : Part 2.1091 (Mobile) Received Date : 2026-06-24 Reviewed By : ( Paddy Chen ) Approved By : ( Chenz Ker) The test results relate only to the samples tested. The test results shown in the test report are traceable to the national/international standards through the calibration of the equipment and evaluated measurement uncertainty herein. The test report shall not be reproduced except in full without the written approval of MRT Technology (Taiwan) Co., Ltd. Report No.: 2606TW0125-U3 Page Number: 2 of 7 Revision History Report No. Version Description Issue Date Note 2606TW0125-U3 V1.0 Original Report 2026-07-31 Valid Report No.: 2606TW0125-U3 Page Number: 3 of 7 CONTENTS Description Page 1. General Information ............................................................................................................ 4 1.1. Applicant .................................................................................................................... 4 1.2. Manufacturer ............................................................................................................. 4 1.3. Testing Facility ........................................................................................................... 4 2. PRODUCT INFORMATION ................................................................................................... 5 2.1. Feature of Equipment under Test .............................................................................. 5 2.2. Description of Available Antennas .............................................................................. 5 3. RF Exposure Evaluation ..................................................................................................... 6 3.1. Limits ......................................................................................................................... 6 3.2. Test Result of RF Exposure Evaluation ...................................................................... 7 Report No.: 2606TW0125-U3 Page Number: 4 of 7 1. General Information 1.1. Applicant Contrinex AG Route du Paqui 3, CH-1720 Corminboeuf, Switzerland 1.2. Manufacturer Contrinex AG Route du Paqui 3, CH-1720 Corminboeuf, Switzerland 1.3. Testing Facility Test Site 1 - MRT Taiwan Laboratory Laboratory Location No. 38, Fuxing 2nd Rd., Guishan Dist., Taoyuan City 333, Taiwan (R.O.C.) Laboratory Accreditations TAF: 3261 FCC: 291082, TW3261 ISED: TW3261 Test Site 2 - MRT Taiwan Laboratory Laboratory Location No. 64, Wenming Rd , Guishan Dist , Taoyuan City 333, Taiwan (R.O.C.) Laboratory Accreditations TAF: 3261 FCC: 291082, TW3261 ISED: TW3261 Report No.: 2606TW0125-U3 Page Number: 5 of 7 2. PRODUCT INFORMATION 2.1. Feature of Equipment under Test Product Name RLH-C23TA-NHV Model No. RLH-C23TA-NHV-224 RFID Specification 13.56 MHz Operating Temperature -25 ~ 80 °C Power Type DC 24V Note: The information of the EUT (Equipment Under Test) was provided by the manufacturer. The accuracy, completeness, and validity of the information are solely the responsibility of the manufacturer. 2.2. Description of Available Antennas Antenna Type PCB Loop Antenna Report No.: 2606TW0125-U3 Page Number: 6 of 7 3. RF Exposure Evaluation 3.1. Limits The 1 mW Blanket Exemption of § 1.1307(b)(3)(i)(A) applies for single fixed, mobile, and portable RF sources with available maximum time-averaged power of no more than 1 mW, regardless of separation distance. The 1 mW blanket exemption applies at separation distances less than 0.5 cm, including where there is no separation. This exemption shall not be used in conjunction with other exemption criteria other than those for multiple RF sources in paragraph § 1.1307(b)(3)(ii)(A). The 1 mW exemption is independent of service type and covers the full range of 100 kHz to 100 GHz, but it shall not be used in conjunction with other exemption criteria or in devices with higher-power transmitters operating in the same time-averaging period. Exposure from such higher-power transmitters would invalidate the underlying assumption that exposure from the lower-power transmitter is the only contributor to SAR in the relevant volume of tissue. Report No.: 2606TW0125-U3 Page Number: 7 of 7 3.2. Test Result of RF Exposure Evaluation Product RLH-C23TA-NHV Test Item RF Exposure Evaluation Mode Frequency Band (MHz) EIRP Output Power (dBm) EIRP Output Power (mW) SAR Test Exclusion Limit (mW) RFID 13.56 -46.56 0.0000022 1 So, this device can complies the SAR test exclusion. Note: For data on output power, please refer to RFID Test Report No. 2606TW0125-U2. (this data has been converted). The End

Test Report

MRT Technology (Taiwan) Co., Ltd. Report No.: 2606TW0125-U2 Phone: +886-3-3288388 Report Version: V1.0 Web: www.mrt-cert.com Is s ue D ate: 2026-07-31 Template Version: 2.2 1 of 39 RF MEASUREMENT REPORT FCC ID: 2ANZQ-RFC23HF Applicant: Contrinex AG Product: RLH-C23TA-NHV Model No.: RLH-C23TA-NHV-224 Brand Name: Contrinex FCC Classification: Part 15 Low Power Communication Device Transmitter (DXX) FCC Rule Part(s): Part 15 Subpart C (Section 15.225) Result: Complies Received Date: 2026-06-24 Test Date: 2026-07-03~2026-07-07 Reviewed By: Paddy Chen Approved By: Chenz Ker The test results relate only to the samples tested. This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report. Testing was performed in accordance with the applicable measurement procedures. The test results reported herein apply only to the specific item(s) tested. The test report shall not be reproduced except in full without the written approval of MRT Technology (Taiwan) Co., Ltd. Report No.: 2606TW0125-U2 2 of 39 Revision History Report No. Version Description Issue Date Note 2606TW0125-U2 V1.0 Original Report 2026-07-31 Valid Report No.: 2606TW0125-U2 3 of 39 CONTENTS Description Page 1. General Information ................................................................................................................................. 5 1.1. Applicant ....................................................................................................................................... 5 1.2. Manufacturer ................................................................................................................................ 5 1.3. Testing Facility .............................................................................................................................. 5 1.4. Product Information ...................................................................................................................... 5 1.5. Radio Specification ....................................................................................................................... 7 2. Test Configuration .................................................................................................................................... 8 2.1. Test Mode .................................................................................................................................... 8 2.2. Test Configuration and Software .................................................................................................. 9 2.3. Applied Standards ...................................................................................................................... 10 2.4. Test Environment Condition ....................................................................................................... 10 3. Antenna Requirements .......................................................................................................................... 11 4. Measuring Instrument ............................................................................................................................ 12 5. Decision Rules and Measurement Uncertainty ................................................................................... 13 5.1. Decision Rules ........................................................................................................................... 13 5.2. Measurement Uncertainty .......................................................................................................... 13 6. Test Result .............................................................................................................................................. 14 6.1. Summary .................................................................................................................................... 14 6.2. In-band Emission Measurement ................................................................................................ 15 6.2.1. Test Limit .................................................................................................................................... 15 6.2.2. Test Procedure ........................................................................................................................... 15 6.2.3. Test Setting ................................................................................................................................. 15 6.2.4. Test Setup .................................................................................................................................. 16 6.2.5. Test Result .................................................................................................................................. 16 6.3. Out-band Emission Measurement .............................................................................................. 17 6.3.1. Test Limit .................................................................................................................................... 17 6.3.2. Test Procedure ........................................................................................................................... 17 6.3.3. Test Setting ................................................................................................................................. 18 6.3.4. Test Setup .................................................................................................................................. 19 6.3.5. Test Result .................................................................................................................................. 19 6.4. 20 dB Bandwidth Measurement ................................................................................................. 20 6.4.1. Test Limit .................................................................................................................................... 20 6.4.2. Te…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: 2606TW0125-UT 1 of 3 RF Test Photograph Description: Front View of Conducted Emission Test Setup - TX Description: Side View of Conducted Emission Test Setup - TX Report No.: 2606TW0125-UT 2 of 3 Description: Radiated Emission Test Setup for 9kHz~30MHz - TX Description: Radiated Emission Test Setup for 9kHz~30MHz - TX Report No.: 2606TW0125-UT 3 of 3 Description: Radiated Emission Test Setup for below 30MHz - TX

Contact Information

Applicant

David Bachmann(SR Manager, R&D)
[email protected]Fax: +41 26 460 46 46

Technical Contact

Contrinex, Inc.Luca Romeo
[email protected]

480 Wrangler Dr. (Suite 100) · Coppell, 75019 · United States

Test Firm

MRT Technology (Taiwan) Co., LtdChenz Ker
[email protected]Fax: +886-3-328-8918

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term