FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shearwater Research Inc./
  3. 2AO24-56021-01

2AO24-56021-01Peregrine Charger Pad

Shearwater Research Inc.
Peregrine Charger Pad - FCC ID 2AO24-56021-01 - Shearwater Research Inc.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
May 20, 2020
Application Purpose
Original Equipment
Date of Application
May 20, 2020
Equipment Note
Peregrine Charger Pad
Frequency Range
0.12438000 - 0.20646000
Company
Shearwater Research Inc.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wireless Charger Non-slip silicone Cable Upper shell Bottom shell Watch wireless coil Connector PCBA .Input:5V/ 1.5A .Output:5V/0.5A .Working Power:2.5W .Working Distance:3mm .Charigng Efficiency:70% .Standard:QI .Quality:Quality and meet CE/FCC/ROHS .Oparation frequency:124.38kHz-206.46kHz .H-field:21.27dBμA/m at 3m .Hardware:56021-01-RevA .Software:56021-01-RevA Application Devices Compatible with Peregrine FCC ID:2AO24-56021-01 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Cover Letter(s)

Applicant Declaration Applicant Declaration Rev:0.0 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Shearwater Research Inc. Address Unit 250 13155 Delf Place Richmond British Columbia Canada Grantee Code 2AO24 FCC ID 2AO24-56021-01 Authorized Contact Name Andy lee Contact Email [email protected] Contact Phone 604-669-9958 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Applicant Signature: Date:2020-05-15 Print Name: Andy lee Title: Mechanical Engineer *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 4 External Photos for SZEM2003001212CR FCC ID:2AO24-56021-01 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 4 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 4 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 4

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 3 Internal Photos for SZEM2003001212CR FCC ID: 2AO24-56021-01 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 3 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 3

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300121202 Page: 1 of 9 Keny Xu EMC Laboratory Manager 1 COVER PAGE Human Exposure Report Application No.: SZEM2003001212CR Applicant: Shearwater Research Inc. Address of Applicant: Unit 250 13155 Delf Place Richmond, British Columbia, Canada Manufacturer: Shearwater Research Inc. Address of Manufacturer: Unit 250 13155 Delf Place Richmond, British Columbia, Canada Factory: Shenzhen Itian Technology Co., Ltd Address of Factory: 501, Buliding C, Hongde Industrial Area, Lianrun Road, Dalang Street, Longhua District, Shenzhen Equipment Under Test (EUT): EUT Name: Peregrine Charger Pad Model No.: 56021-01 Trade mark: FCC ID: 2AO24-56021-01 Standards: 47 CFR PART 1, Subpart I, Section 1.1310 47 CFR PART 2, Subpart J, Section 2.1091 Date of Receipt: 2020-03-09 Date of Test: 2020-03-12 to 2020-03-18 Date of Issue: 2020-03-24 Test Result : Pass* * In the configuration tested, the EUT complied with the standards specified above SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300121202 Page: 2 of 9 Revision Record Version Chapter Date Modifier Remark 01 2020-03-24 Original Authorized for issue by: Calvin Weng /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300121202 Page: 3 of 9 2 Contents 1 COVER PAGE ..................................................................................................................................... 1 2 CONTENTS ......................................................................................................................................... 3 3 GENERAL INFORMATION .................................................................................................................. 4 3.1 DETAILS OF E.U.T. ............................................................................................................................. 4 3.2 DESCRIPTION OF SUPPORT UNITS ........................................................................................................ 4 3.3 TEST LOCATION ................................................................................................................................. 5 3.4 TEST FACILITY ................................................................................................................................... 5 3.5 DEVIATION FROM STANDARDS .............................................................................................................. 5 3.6 ABNORMALITIES FROM STANDARD CONDITIONS ..................................................................................... 5 4 EQUIPMENTS USED DURING TEST .................................................................................................. 6 5 TEST RESULTS .................................................................................................................................. 7 5.1 RF EXPOSURE TEST ........................................................................................................................... 7 5.1.1 E.U.T. Operation ...................................................................................................................... 7 6 PHOTOGRAPHS ................................................................................................................................. 9 6.1 TEST SETUP PHOTOS .......................................................................................................................... 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300121202 Page: 4 of 9 3 General Information 3.1 Details of E.U.T. Power Supply: Input: DC5V, 1.5A Output: DC5V, 0.5A Operation Frequency: 124.38kHz to 206.46kHz Modulation Type: Load modulation Antenna Type: Loop antenna Antenna Gain: 0dBi Remark: This device has been tested the full load at 2.5W. 3.2 Description of Support Units Description Manufacturer Model No. Serial No. Adapter Apple A1357 W010A051 REF. No.SEA0500 Micro USB Cable PHILIPS SWR2101 REF. No.SEA0700 Peregrine Shearwater Research Inc. 16001 N/A SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300121202 Page: 5 of 9 3.3 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab, No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong,China 518057. Tel: +86 755 2601 2053 Fax: +86 755 2671 0594 No tests were sub-contracted. 3.4 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized by ISED as an accredited testing laboratory. CAB identifier: CN0006. IC#: 4620C. 3.5 Deviation from Standards None. 3.6 Abnormalities from Standard Conditions None. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300121202 Page: 6 of 9 4 Equipments Used during Test Item Equipment…

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300121201 Page: 1 of 30 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZEM2003001212CR Applicant: Shearwater Research Inc. Address of Applicant: Unit 250 13155 Delf Place Richmond, British Columbia, Canada Manufacturer: Shearwater Research Inc. Address of Manufacturer: Unit 250 13155 Delf Place Richmond, British Columbia, Canada Factory: Shenzhen Itian Technology Co., Ltd Address of Factory: 501, Buliding C, Hongde Industrial Area, Lianrun Road, Dalang Street, Longhua District, Shenzhen Equipment Under Test (EUT): EUT Name: Peregrine Charger Pad Model No.: 56021-01 Trade mark: FCC ID: 2AO24-56021-01 Standard(s) : 47 CFR Part 15, Subpart C Date of Receipt: 2020-03-09 Date of Test: 2020-03-12 to 2020-03-18 Date of Issue: 2020-03-24 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300121201 Page: 2 of 30 Revision Record Version Chapter Date Modifier Remark 01 2020-03-24 Original Authorized for issue by: Calvin Weng /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300121201 Page: 3 of 30 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C N/A 47 CFR Part 15, Subpart C 15.203 Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass 20dB Bandwidth 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.9.2 47 CFR Part 15, Subpart C 15.215 Pass Restricted Bands 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 Pass Radiated Emissions (9kHz-30MHz) 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.4 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Emissions (30MHz-1GHz) 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300121201 Page: 4 of 30 3 Contents Page 1 COVER PAGE ..................................................................................................................................... 1 2 TEST SUMMARY ................................................................................................................................. 3 3 CONTENTS ......................................................................................................................................... 4 4 GENERAL INFORMATION .................................................................................................................. 6 4.1 DETAILS OF E.U.T. ......................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS .................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY ......................................................................................................... 6 4.4 TEST LOCATION ............................................................................................................................. 7 4.5 TEST FACILITY ............................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ......................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................. 7 5 EQUIPMENT LIST ............................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................11 6.1 ANTENNA REQUIREMENT ................................................................................................................11 6.1.1 Test Requirement: ..................................................................................................................11 6.1.2 Conclusion ..............................................................................................................................11 7 RADIO SPECTRUM MATTER TEST RESULTS .................................................................................12 7.1 CONDUCTED EMISSIONS AT AC POWER LINE (150KHZ-30MHZ) ........................................................12 7.1.1 E.U.T. Operation .....................................................................................................................13 7.1.2 Test Setup Diagram ................................................................................................................13 7.1.3 Measurement Procedure and Data .........................................................................................13 7.2 20DB BANDWIDTH .........................................................................................................................16 7.2.1 E.U.T. Operation .....................................................................................................................16 7.2.2 Test Setup Diagram ................................................................................................................16 7.2.3 Measurement Procedure and Data .........................................................................................16 7.3 RESTRICTED BANDS ......................................................................................................................18 7.3.1 E.U.T. Operation ............................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 3 Setup Photos for SZEM2003001212CR FCC ID: 2AO24-56021-01 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 3 1 Photographs 1.1 Conducted Emissions at AC Power Line (150kHz-30MHz) Test Setup 1.2 Radiated Emissions (9kHz-30MHz) Test Setup SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 3 1.3 Radiated Emissions (30MHz-1GHz) Test Setup

Test Setup Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 4 RF exposure setup for SZEM2003001212CR FCC ID: 2AO24-56021-01 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 4 1.1 Test photos Test with mobile phone with 15cm measurement distance Side 1 Side 2 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 4 Side 4 Side 3 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 4 Top

Contact Information

Applicant

Matthew Ashley(Engineering Manager)
[email protected]604-669-9958Fax: 604 681 4982

Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Keny Xu
[email protected]86 755 25328629

No.1 Workshop, M-10, Middle Section, · Shenzhen · China

Test Firm

SGS-CSTC Standards Technical Services Co., LtdDerek Yang
[email protected]+86 0135 6484 8721

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.12438 MHz - 0.20646 MHz-
Confidentiality
Long Term

Other Applications from Shearwater Research Inc.

Air integration pressure transmitter - FCC ID 2AO24-17001 - Shearwater Research Inc.
2AO24-17001

Air integration pressure transmitter

May 18, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz