2AO4C-WLC759DWWireless Charger Unit

UniMax Electronics Inc.

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Mar 27, 2026
Application Purpose
Original Equipment
Equipment Note
Wireless Charger Unit
Frequency Range
0.12777000 - 0.12777000
Company
UniMax Electronics Inc.
Country
Taiwan

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

.tw

ID Label/Location Info

Page 1 of 2 Product Name:Wirless Charger Unit/無線充電器 Model No.: GN819-01040 Brand:UNIMAX Production Label Page 2 of 2 Label Location

RF Exposure Info

1/1 DASY8 Module WPT Measurement Report Device under test Info: V-Coil35085_1023 Tool info DASY software version: DASY8 Module WPT 3.2.0.6673 Probe model, serial no. and configuration date: MAGPy-8H3D+E3Dv2, WP000211, 2025/06/05 Software version: 3.2.9, backend: 3.2.20 Hardware version: FPGA: 100, FW: N/A Scan info Center location: x: 82.44 mm, y: -102.00 mm, z: 38.64 mm Dimensions: x: 389.0 mm, y: 521.0 mm, z: 36.7 mm Resolution: x: 7.33 mm, y: 7.33 mm, z: 7.33 mm Completed on: 2026/01/28 Measurement results Maximum H-field [rms]: magnitude:136.78 A/m x: 27.33 A/m, y: 119.95 A/m, z: 59.76 A/m Maximum H-field location relative to DUT: x: 25.67 mm, y: -172.33 mm, z: 8.50 mm Maximum E-field [rms]: magnitude:270.35 V/m x: 11.22 V/m, y: 3.32 V/m, z: 270.10 V/m Maximum E-field location relative to DUT: x: 95.33 mm, y: 146.67 mm, z: 0.00 m Distance to -20.0 dB boundary: 60.47 mm Offset relative to DUT: x: 0.00 m, y: 0.00 m, z: 1.00 mm H-field magnitude [rms] at center locationH-field magnitude [rms] at lowest plane Incident fields and induced fields in the homogeous phantom at the peak frequency Peak incident fields [rms] Peak E ind [V/m, rms] Peak J ind [A/m 2 , rms ] psSAR [mW/kg]H-field extent Distance [mm] H inc [A/m]E inc [V/m] Cube avg.LocalLine avg.Surface avg.1g avg.10g avg. -20 dB radius [mm] 0.00 2152703.453.483.492.436.985.21182 2.001952473.253.283.292.306.264.74184 Compliance evaluation (Field values at the peak frequency) ICNIRP 2010/2020ICNIRP 1998IEEE 2019FCCHC Code 6 RL [rms]BR [rms]RL [rms]BR [rms]ERL [rms]DRL [rms]MPE [rms]BR [rms]RL [rms]BR [rms] Distance pH inc pE inc pE indpsSAR pH inc pE inc pJ indpsSAR pH inc pE inc pE indpsSAR pH inc pE inc pE indpsSAR pH inc pE inc pE indpsSAR [mm][A/m][V/m][V/m][mW/kg][A/m][V/m] [A/m 2 ] [mW/kg][A/m][V/m][V/m][mW/kg][A/m][V/m][V/m][mW/kg][A/m][V/m][V/m][mW/kg] 0.00 21527026.05.212152702.445.2121527013.55.21215270N/A6.9821527037.06.98 2.00 19524724.64.741952472.304.7419524712.84.74195247N/A6.2619524735.16.26 Coverage factors: w E ind, cube avg. = [7.53, 7.56], w E ind, local = [10.63, 10.68], w E ind, line avg. = [3.87, 3.88] Compliance evaluation (Exposure ratios) (with multi-frequency enhancement, total field evaluation, coverage evaluation) ICNIRP 2010/2020ICNIRP 1998IEEE 2019FCCHC Code 6 RLBRRLBRERLDRLMPEBRRLBR Distance [mm] pH inc pE inc pE indpsSAR pH inc pE inc pJ indpsSAR pH inc pE inc pE indpsSAR pH inc pE inc pE indpsSAR pH inc pE inc pE indpsSAR NSTHNSTHNSTHN/AN/ANSTHNSTHNSTHNSTHN/AN/AN/ATHNSTHNSTHNSTH 0.00 10.2N/A11.9N/A2.27N/A43.011.314.4N/A1.32N/A1.6N/A0.76N/A2.396.9N/AN/A2.39N/A11.9N/A3.23N/A 2.00 9.29N/A10.8N/A2.15N/A39.010.313.6N/A1.2N/A1.46N/A0.72N/A2.176.31N/AN/A2.17N/A10.8N/A3.06N/A Coverage factors: w E ind, cube avg. = [7.53, 7.56], w E ind, local = [10.63, 10.68], w E ind, line avg. = [3.87, 3.88] Simulation performed at 2026/01/28 using Sim4Life version 9.0.0.18820

RF Exposure Info

1/1 DASY8 Module WPT Measurement Report Device under test Info: 06_Front_0mm Tool info DASY software version: DASY8 Module WPT 3.2.0.6673 Probe model, serial no. and configuration date: MAGPy-8H3D+E3Dv2, WP000211, 2025/06/05 Software version: 3.2.9, backend: 3.2.20 Hardware version: FPGA: 100, FW: N/A Scan info Center location: x: 77.66 mm, y: 28.43 mm, z: 74.58 mm Dimensions: x: 168.3 mm, y: 257.0 mm, z: 36.9 mm Resolution: x: 7.33 mm, y: 7.33 mm, z: 7.33 mm Completed on: 2026/01/28 Measurement results Maximum H-field [rms]: magnitude:10.00 A/m x: 1.88 A/m, y: 1.34 A/m, z: 9.73 A/m Maximum H-field location relative to DUT: x: -40.33 mm, y: -18.33 mm, z: 8.50 mm Maximum E-field [rms]: magnitude:53.64 V/m x: 595.04 mV/m, y: 307.88 mV/m, z: 53.64 V/m Maximum E-field location relative to DUT: x: 0.00 m, y: 14.67 mm, z: 0.00 m Distance to -20.0 dB boundary: 49.19 mm Offset relative to DUT: x: 0.00 m, y: 0.00 m, z: 1.00 mm H-field magnitude [rms] at center locationH-field magnitude [rms] at lowest plane Incident fields and induced fields in the homogeous phantom at the peak frequency Peak incident fields [rms] Peak E ind [V/m, rms] Peak J ind [A/m 2 , rms ] psSAR [mW/kg]H-field extent Distance [mm] H inc [A/m]E inc [V/m] Cube avg.LocalLine avg.Surface avg.1g avg.10g avg. -20 dB radius [mm] 0.00 19.853.60.1080.110.110.07085.11e-32.79e-357.9 Compliance evaluation (Field values at the peak frequency) ICNIRP 2010/2020ICNIRP 1998IEEE 2019FCCHC Code 6 RL [rms]BR [rms]RL [rms]BR [rms]ERL [rms]DRL [rms]MPE [rms]BR [rms]RL [rms]BR [rms] Distance pH inc pE inc pE indpsSAR pH inc pE inc pJ indpsSAR pH inc pE inc pE indpsSAR pH inc pE inc pE indpsSAR pH inc pE inc pE indpsSAR [mm][A/m][V/m][V/m][mW/kg][A/m][V/m] [A/m 2 ] [mW/kg][A/m][V/m][V/m][mW/kg][A/m][V/m][V/m][mW/kg][A/m][V/m][V/m][mW/kg] 0.00 19.853.60.612 2.79e- 3 19.853.60.0722 2.79e- 3 19.853.60.339 2.79e- 3 19.853.6N/A 5.11e- 3 19.853.60.882 5.11e- 3 Coverage factors: w E ind, cube avg. = [5.67], w E ind, local = [8.01], w E ind, line avg. = [3.07] Compliance evaluation (Exposure ratios) (with multi-frequency enhancement, total field evaluation, coverage evaluation) ICNIRP 2010/2020ICNIRP 1998IEEE 2019FCCHC Code 6 RLBRRLBRERLDRLMPEBRRLBR Distance [mm] pH inc pE inc pE indpsSAR pH inc pE inc pJ indpsSAR pH inc pE inc pE indpsSAR pH inc pE inc pE indpsSAR pH inc pE inc pE indpsSAR NSTHNSTHNSTHN/AN/ANSTHNSTHNSTHNSTHN/AN/AN/ATHNSTHNSTHNSTH 0.00 0.940.528.933.710.04<0.013.9610.00.36<0.010.120.071.210.450.01<0.0112.12.1N/A<0.010.223.468.93N/A0.05<0.01 Coverage factors: w E ind, cube avg. = [5.67], w E ind, local = [8.01], w E ind, line avg. = [3.07] Simulation performed at 2026/01/28 using Sim4Life version 9.0.0.18820 1/1 DASY8 Module WPT Measurement Report Device under test Info: 12_Front_0mm Tool info DASY software version: DASY8 Module WPT 3.2.0.6673 Probe model, serial no. and configuration date: MAGPy-8H3D+E3Dv2, WP000211, 2025/06/05 Software version: 3.2.9, backend: 3.2.20 Hardware version: FPGA: 100, FW: N/A Scan info Center location: x: 84.74 mm, y: 45.34 mm, z: 52.53 mm Dimensions: x: 256.3 mm, y: 256.7 mm, z: 36.7 mm Resolution: x: 7.33 mm, y: 7.33 mm, z: 7.33 mm Completed on: 2026/01/28 Measurement results Maximum H-field [rms]: magnitude:7.54 A/m x: 289.12 mA/m, y: 766.09 mA/m, z: 7.49 A/m Maximum H-field location relative to DUT: x: -62.33 mm, y: -18.33 mm, z: 8.50 mm Maximum E-field [rms]: magnitude:55.31 V/m x: 3.52 V/m, y: 217.88 mV/m, z: 55.20 V/m Maximum E-field location relative to DUT: x: 0.00 m, y: 0.00 m, z: 0.00 m Distance to -20.0 dB boundary: 51.33 mm Offset relative to DUT: x: 0.00 m, y: 0.00 m, z: 1.00 mm H-field magnitude [rms] at center locationH-field magnitude [rms] at lowest plane Incident fields and induced fields in the homogeous phantom at the peak frequency Peak incident fields [rms] Peak E ind [V/m, rms] Peak J ind [A/m 2 , rms ] psSAR [mW/kg]H-field extent Distance [mm] H inc [A/m]E inc [V/m] Cube avg.LocalLine avg.Surface avg.1g avg.10g avg. -20 dB radius [mm] 0.00 15.455.30.08920.09120.09070.05863.48e-31.92e-357.5 Compliance evaluation (Field values at the peak frequency) ICNIRP 2010/2020ICNIRP 1998IEEE 2019FCCHC Code 6 RL [rms]BR [rms]RL [rms]BR [rms]ERL [rms]DRL [rms]MPE [rms]BR [rms]RL [rms]BR [rms] Distance pH inc pE inc pE indpsSAR pH inc pE inc pJ indpsSAR pH inc pE inc pE indpsSAR pH inc pE inc pE indpsSAR pH inc pE inc pE indpsSAR [mm][A/m][V/m][V/m][mW/kg][A/m][V/m] [A/m 2 ] [mW/kg][A/m][V/m][V/m][mW/kg][A/m][V/m][V/m][mW/kg][A/m][V/m][V/m][mW/kg] 0.00 15.455.30.507 1.92e- 3 15.455.30.0600 1.92e- 3 15.455.30.280 1.92e- 3 15.455.3N/A 3.49e- 3 15.455.30.731 3.49e- 3 Coverage factors: w E ind, cube avg. = [5.66], w E ind, local = [8.00], w E ind, line avg. = [3.07] Compliance evaluation (Exposure ratios) (with multi-frequency enhancement, total field evaluation, coverage evaluation) ICNIRP 2010/2020ICNIRP 1998IEEE 2019FCCHC Code 6 RLBRRLBRERLDRLMPEBRRLBR Distance [mm] pH inc pE inc pE indpsSAR pH inc pE inc pJ indpsSAR pH inc pE inc pE indpsSAR pH inc pE inc pE indpsSAR pH inc pE inc pE indpsSAR NSTHNSTHNSTHN/AN/ANSTHNSTHNSTHNSTHN/AN/AN/ATHNSTHNSTHNSTH 0.00 0.730.406.911.930.03<0.013.077.110.29<0.010.090.050.930.260.01<0.019.421.63N/A<0.010.172.696.91N/A0.04<0.01 Coverage factors: w E ind, cube avg. = [5.66], w E ind, local = [8.00], w E ind, line avg. = [3.07] Simulation performed at 2026/01/28 using Sim4Life version 9.0.0.18820 1/1 DASY8 Module WPT Measurement Report Device under test Info: 11_Front_0mm Tool info DASY software version: DASY8 Module WPT 3.2.0.6673 Probe model, serial no. and configuration date: MAGPy-8H3D+E3Dv2, WP000211, 2025/06/05 Software version: 3.2.9, backend: 3.2.20 Hardware version: FPGA: 100, FW: N/A Scan info Center location: x: 77.62 mm, y: 28.40 mm, z: 74.56 mm Dimensions: x: 212.4 mm, y: 257.0 mm, z: 36.9 mm Resolution: x: 7.33 mm, y: 7.33 mm, z: 7.33 mm Completed on: 2026/01/28 Measurement results Maximum H-field [rms]: magnitude:9.69 A/m x: 1.80 A/m, y: 491.13 mA/m, z: 9.5…

Text truncated - open the document above for the full version.

RF Exposure Info

SPORTON INTERNATIONAL INC. Page Number : 1 of 12 TEL : 886-3-327-3456 Report Issued Date : Feb. 03, 2026 FAX : 886-3-328-4978 RF Exposure Report Report No. : FA612122 RF Exposure Report FCC ID : 2AO4C-WLC759DW Equipment : Wireless Charger Unit Brand Name : UNIMAX Model Name : GN819-01040 Applicant : UniMax Electronics Inc. 15, Li-Te Rd., Beitou Dist.,112 Taipei City, Taiwan Standard : FCC 47 CFR Part 2.1093 The product was received on Jan. 23, 2026 and testing was started from Jan. 28, 2026 and completed on Jan. 28, 2026. We, SPORTON INTERNATIONAL INC., would like to declare that the tested sample provide by manufacturer and the test data has been evaluated in accordance with the test procedures given in 47 CFR Part 2.1093 and has been pass the FCC requirement. The results in this report apply exclusively to the tested model / sample. Without written approval of SPORTON INTERNATIONAL INC. Laboratory, the test report shall not be reproduced except in full. Sporton International Inc. Wensan Laboratory No.58, Aly. 75, Ln. 564, Wenhua 3rd, Rd., Guishan Dist., Taoyuan City 333010, Taiwan Approved by: Cona Huang / Deputy Manager SPORTON INTERNATIONAL INC. Page Number : 2 of 12 TEL : 886-3-327-3456 Report Issued Date : Feb. 03, 2026 FAX : 886-3-328-4978 RF Exposure Report Report No. : FA612122 Table of Contents 1. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ............................................................................. 4 2. RF EXPOSURE LIMIT ................................................................................................................................. 4 3. SYSTEM DESCRIPTION AND SETUP ....................................................................................................... 5 4. EQUIPMENT LIST ....................................................................................................................................... 8 5. SYSTEM VALIDIATION .............................................................................................................................. 8 6. RF EXPOSURE RESULTS .......................................................................................................................... 9 6.1. Maximum Permissible Exposure Evaluation ..................................................................................... 9 6.2. Peak Spatial-Average SAR Evaluation .............................................................................................. 9 7. UNCERTAINTY .......................................................................................................................................... 10 8. REFERENCE ............................................................................................................................................. 12 Appendix A. Plots of System Performance Check Appendix B. Plots of Highest Measurement Result Appendix C. DASY Calibration Certificate Appendix D. Test Setup Photo SPORTON INTERNATIONAL INC. Page Number : 3 of 12 TEL : 886-3-327-3456 Report Issued Date : Feb. 03, 2026 FAX : 886-3-328-4978 RF Exposure Report Report No. : FA612122 Revision History REPORT NO. VERSION DESCRIPTION ISSUED DATE FA612122 Rev. 01 Initial issue of report Feb. 03, 2026 SPORTON INTERNATIONAL INC. Page Number : 4 of 12 TEL : 886-3-327-3456 Report Issued Date : Feb. 03, 2026 FAX : 886-3-328-4978 RF Exposure Report Report No. : FA612122 1. Description of Equipment Under Test (EUT) Product Feature & Specification FCC ID 2AO4C-WLC759DW Equipment Wireless Charger Unit Brand Name UNIMAX Model Name GN819-01040 Frequency Range 127.77KHz Mode ASK 2. RF Exposure Limit <Limits for Maximum Permissible Exposure> § 1.1310 The criteria listed in table 1 shall be used to evaluate the environmental impact of human exposure to radio frequency(RF) radiation as specified in § 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of § 2.1093 of this chapter. (1) Occupational/controlled exposure limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when a person is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. The phrase fully aware in the context of applying these exposure limits means that an exposed person has received written and/or verbal information fully explaining the potential for RF exposure resulting from his or her employment. With the exception of transient persons, this phrase also means that an exposed person has received appropriate training regarding work practices relating to controlling or mitigating his or her exposure. Such training is not required for transient persons, but they must receive written and/or verbal information and notification (for example, using signs) concerning their exposure potential and appropriate means available to mitigate their exposure. The phrase exercise control means that an exposed person is allowed to and knows how to reduce or avoid exposure by administrative or engineering controls and work practices, such as use of personal protective equipment or time averaging of exposure. (2) General population/uncontrolled exposure limits apply in situations in which the general public may be exposed, or in which persons who are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. <Limit for peak spatial-average SAR> The SAR limits for general population/uncontrolled exposure are 0.08 W/kg, as averaged over the whole body, and a peak spatial- average SAR of 1.6 W/kg, averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the parts of the human body treated as extremities, su…

Text truncated - open the document above for the full version.

Test Report

INPAQ TECHNOLOGY CO., LTD 2025/10/17 PAGE 1 OF 6 WPC-W-P-TX-MPA10-001-B Specification 1. Explanation of Part Number: W P C W P T X M P A 10 0 0 1 B (1) (2) (3) (4) (5) (6) (7) (1) Product type:Wireless Power Charging (2) Mode:WPC (3) Active or passive:Passive (4) Type:Power Transmitter (5) Antenna material or type:Coil Antenna (6) Suffix:Serial number (7) Automobile:Before installation UNLESS OTHER SPECIFIED TOLERANCES ON: X=± X.X=± X.XX=± ANGLES=± HOLEDIA=± INPAQ TECHNOLOGY CO., LTD. SCALE: N/A UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:廖偉廷 CHECKED BY:鄭榮謀 DESIGNED BY:曾國恒 APPROVED BY:洪碩國 TITLE:WPC-W-P-TX-MPA10-001-B Specification DOCUMENT NO. ENS000131240 SPEC REV. P4 INPAQ TECHNOLOGY CO., LTD 2025/10/17 PAGE 2 OF 6 2. Dimension: 3. Solid picture and Material list: Index Item Description Color Q’ty 1 Coil USTC Pastel orange 1 1-1 Tape Insulating tapes Orange 1 1-2 Lead-free tin Sn99.3%、Cu0.7% Silver 0.1g 2 Adhesive 3M-468_50x40x0.13mm White translucency 1 3 Ferrite Core Mn-Zn95_56x49xT1mm Black 1 4 Adhesive 3M-468_56x49x0.13mm White translucency 1 UNLESS OTHER SPECIFIED TOLERANCES ON: X=± X.X=± X.XX=± ANGLES=± HOLEDIA=± INPAQ TECHNOLOGY CO., LTD. SCALE: N/A UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:廖偉廷 CHECKED BY:鄭榮謀 DESIGNED BY:曾國恒 APPROVED BY:洪碩國 TITLE:WPC-W-P-TX-MPA10-001-B Specification DOCUMENT NO. ENS000131240 SPEC REV. P4 INPAQ TECHNOLOGY CO., LTD 2025/10/17 PAGE 3 OF 6 4. Coil Specification: a.) COIL MATERIAL:0.08*105P(USTC) b.) LAYERS:1LAYER 5. Test Condition: 5.1 Test Equipment 5.2 Electrical Specification UNLESS OTHER SPECIFIED TOLERANCES ON: X=± X.X=± X.XX=± ANGLES=± HOLEDIA=± INPAQ TECHNOLOGY CO., LTD. SCALE: N/A UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:廖偉廷 CHECKED BY:鄭榮謀 DESIGNED BY:曾國恒 APPROVED BY:洪碩國 TITLE:WPC-W-P-TX-MPA10-001-B Specification DOCUMENT NO. ENS000131240 SPEC REV. P4 NO ITEM Maker/Part name Remark 1 LCR Meter WAYNE KERR 6500B L/Q/Rdc Tester 2 Test Fixture WAYNE KERR FIXTURE 20A 1030 3 Calibration Kit INPAQ Internal Coil Test Item Test Condition Specification Inductance 100K Hz, 1V 12.5 uH±8% Q value 100K Hz, 1V 100 Min DCR 1Hz@25°C 75 mΩ Max FLQ(100K~200K) INPAQ TECHNOLOGY CO., LTD 2025/10/17 PAGE 4 OF 6 6. Reliability Test: NO ITEM Condition Characteri stics Remark 1 High Temp. Storage Test Initial value measured at standard test condition. Test Conditions: 125 ±5 °C, 1000hr Measuring After 24±4hr at standard conditions. - No electrical, appearance problem Sample Size: 77 PCS 2 Temperature cycle Test Initial value measured at standard test condition. Test Conditions: -40°C, 0.5hr➔125°C, 0.5hr Test Cycle: 1000 times Measuring After 24±4hr at standard conditions. Sample Size: 77 PCS 3 High Temp &Humidity Storage Test Initial value measured at standard test condition. Test Conditions: 85±5°C, 85±5% RH, 1000hr Measuring After 24±4hr at standard conditions. Sample Size: 77 PCS 4 Vibration 5 g's for 20 minutes, 12 cycles each of 3 orientations. Test from 10-2000Hz. Sample Size: 30 PCS UNLESS OTHER SPECIFIED TOLERANCES ON: X=± X.X=± X.XX=± ANGLES=± HOLEDIA=± INPAQ TECHNOLOGY CO., LTD. SCALE: N/A UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:廖偉廷 CHECKED BY:鄭榮謀 DESIGNED BY:曾國恒 APPROVED BY:洪碩國 TITLE:WPC-W-P-TX-MPA10-001-B Specification DOCUMENT NO. ENS000131240 SPEC REV. P4 INPAQ TECHNOLOGY CO., LTD 2025/10/17 PAGE 5 OF 6 7. Package Spec: A small boxed:18 pcs Tray (total 4 pcs), total number of samples 18 * 4 = 72 pcs. A Carton boxed include 4 small boxed, total number of samples 72 * 4 = 288 pcs. 8. Packing Information: 1.) Do not apply high mechanical force or damage on the products during attaching process. 2.) Do not store in high temperature or high humidity environments. 3.) Avoid heat shock, vibration, direct sunlight, etc. 4.) Do not store in corrosive gas atmosphere such as one containing sulfurous acid gas or alkaline gas. 9. Operating & Storage Condition: 1.) OPERATING TEMPERATURE RANGE:-40°C~+125°C 2.) STORAGE TEMPERATURE RANGE:-40°C~+125°C 9.1. Recommended storage condition: Store in room condition as listed below:Temperature -20°C~+45ºC, Humidity 80% Max. 10. Certificate: IATF16949 QC080000 ISO45001 ISO9001 ISO14001 Compliant with AEC-Q200 Can Apply for QI Certified off MP-A10 UNLESS OTHER SPECIFIED TOLERANCES ON: X=± X.X=± X.XX=± ANGLES=± HOLEDIA=± INPAQ TECHNOLOGY CO., LTD. SCALE: N/A UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:廖偉廷 CHECKED BY:鄭榮謀 DESIGNED BY:曾國恒 APPROVED BY:洪碩國 TITLE:WPC-W-P-TX-MPA10-001-B Specification DOCUMENT NO. ENS000131240 SPEC REV. P4 INPAQ TECHNOLOGY CO., LTD 2025/10/17 PAGE 6 OF 6

Test Report

Project No: TM-2512000212P Page 1 / 33 Report No.: TMWK2512005642KR FCC ID: 2AO4C-WLC759DW Rev. 02 No.11, Wugong 6th Rd., Wugu Dist., New Taipei City , Taiwan /新北市五股區五工六路11號 t:(886-2) 2299-9720 f:(886-2) 2299-9721 www.sgs.com.tw Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of client’s instruction, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced, except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Compliance Certification Services Inc. 程智科技股份有限公司 Member of the SGS Group FCC 47 CFR PART 15 SUBPART C TEST REPORT For Wireless Charger Unit Model: GN819-01040 Trade Name: UNIMAX Issued to UniMax Electronics Inc. 15, Li-Te Rd., Beitou Dist.,112 Taipei City, Taiwan Issued by Compliance Certification Services Inc. Wugu Laboratory No.11, Wugong 6th Rd., Wugu Dist., New Taipei City, Taiwan Issued Date: March 25, 2026 This document cannot be reproduced except in full, without prior written approval of the Company. 本報告未經本公司書面許可,不可部份複製。 Project No: TM-2512000212P Page 2 / 33 Report No.: TMWK2512005642KR Rev. 02 Revision History Rev. Issue Date Revisions Effect Page Revised By 00 March 12, 2026 Initial Issue ALL Peggy Tsai 01 March 25, 2026 See the following Note Rev.(01) P. 6, 14 Peggy Tsai 02 March 25, 2026 See the following Note Rev.(02) P. 6 Peggy Tsai Rev. (01) 1. Modify test summary in section 3. 2. Modify note in section 7.1. Rev. (02) 1. Modify test summary in section 3. This document cannot be reproduced except in full, without prior written approval of the Company. 本報告未經本公司書面許可,不可部份複製。 Project No: TM-2512000212P Page 3 / 33 Report No.: TMWK2512005642KR Rev. 02 TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION ......................................................................................... 4 2. EUT DESCRIPTION ............................................................................................................. 5 3. TEST SUMMARY ................................................................................................................. 6 4. TEST METHODOLOGY ....................................................................................................... 7 4.1 EUT CONFIGURATION .................................................................................................. 7 4.2 EUT EXERCISE .............................................................................................................. 7 4.3 GENERAL TEST PROCEDURES ................................................................................... 7 4.4 FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS ........................................ 8 4.5 DESCRIPTION OF TEST MODES .................................................................................. 9 5. INSTRUMENT CALIBRATION ........................................................................................... 10 5.1 MEASURING INSTRUMENT CALIBRATION ................................................................ 10 5.2 MEASUREMENT EQUIPMENT USED .......................................................................... 11 5.3 MEASUREMENT UNCERTAINTY ................................................................................ 12 5.4 FACILITIES AND TEST LOCATION .............................................................................. 12 6. SETUP OF EQUIPMENT UNDER TEST ............................................................................ 13 6.1 SUPPORT AND EUT ACCESSORIES EQUIPMENT .................................................... 13 6.2 TEST SETUP DIAGRAM ............................................................................................... 13 6.3 TEST PROGRAM .......................................................................................................... 13 7. TEST REQUIREMENTS ..................................................................................................... 14 7.1 20DB BANDWIDTH ....................................................................................................... 14 7.2 TRANSMITTER RADIATED EMISSION ........................................................................ 16 7.3 AC POWER-LINE CONDUCTED EMISSION ................................................................ 32 7.4 COIL RULERS AND SPECIFICATIONS ....................................................................... 33 APPENDIX A PHOTOGRAPHS OF TEST SETUP ................................................................. A-1 APPENDIX 1 - PHOTOGRAPHS OF EUT This document cannot be reproduced except in full, without prior written approval of the Company. 本報告未經本公司書面許可,不可部份複製。 Project No: TM-2512000212P Page 4 / 33 Report No.: TMWK2512005642KR Rev. 02 1. TEST RESULT CERTIFICATION Applicant: UniMax Electronics Inc. 15, Li-Te Rd., Beitou Dist.,112 Taipei City, Taiwan Manufacturer: UniMax Electronics Inc. 15, Li-Te Rd., Beitou Dist.,112 Taipei City, Taiwan Equipment Under Test: Wireless Charger Unit…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Alan Tseng(Specialist)
[email protected]Fax: +886-2-2893-1687

Technical Contact

ASUS COMPUTER INTERNATIONALGigi Liu
[email protected]

48720 Kato Road, · Fremont, 94538 · United States

Test Firm

Compliance Certification Services Inc. Wugu Lab.Czerny Lin
[email protected]Fax: +886-2-2299-9721

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.12777 MHz - 0.12777 MHz-
Confidentiality
Long Term

Other Applications from UniMax Electronics Inc.

WIRELESS CHARGER UNIT - FCC ID 2AO4C-WLCD03BW - UniMax Electronics Inc.
2AO4C-WLCD03BW

WIRELESS CHARGER UNIT

Jan 09, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz