Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jan 12, 2020
Application Purpose
Original Equipment
Date of Application
Jan 12, 2020
Equipment Note
EXOvault mouse
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Golden Rock Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Bluetooth to channel from Power Button Dongle Press to change communication Click to pair Bluetooth (you must frist select Bluetooth channel) Full manual availble at www.EXOvault.com EXOvault Mouse Quick Start Dongle will auto install and pair with mouse Pairing symbol. To pair Bluetooth frist select Bluetooth channel then hold down the pairing button on the bottom of the mouse. When pairing mode is entered, the display points to this symbol. When pairing is successful, the indicator points back to the Bluetooth channel. pairs) Off Bluetooth Channel selected automatically 2.4g Dongle Channel selected (dongle CPI mode (changes speed of mouse) Battery power display 0 to 100 in 17% increments FCC Warning Statement Changes or modifications not expressly approved by t he party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐‐ Reorient or relocate the receiving antenna. ‐‐ Increase the separation between the equipment and receiver. ‐‐ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐‐ Consult the dealer or an experienced radio/TV technician for help.

Cover Letter(s)

<ShenzhenGoldenRockTechnologyCo.,Ltd.> OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:Jan.07,2020 Subject;RequestforLongTermConfidentiality FCCID:2AO78-MICE01 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,weare requestingtheCommissiontowithholdthefollowingattachment(s)asconfidentialdocumentsfrom publicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredasproprietary informationinoperationoftheequipment.Thepublicdisclosureofthesedocumentsmightbeharmfulto ourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatandcorrespondenceduring thecertificationreviewprocesscannotbegrantedasconfidentialdocumentsandthisinformationwillbe availableforpublicreviewoncethegrantofequipmentauthorizationisissued. Sincerely, Signature: Name:MinMo Title:Manager

Cover Letter(s)

ShenzhenGoldenRockTechnologyCo.,Ltd. LetterofAuthorization Company:ShenzhenGoldenRockTechnologyCo.,Ltd. Address:Room#338,3/F,HuafengBuilding,41District,XinanStreet,Baoan District,Shenzhen,China ProductName:EXOvaultmouse ModelNumber:Mouse01 FCCIdentifier:2AO78-MICE01 WeauthorizeMiCOMLabsInc,575BoulderCourt,Pleasanton,California94566, USA,toactonourbehalfonallmattersconcerningtheabovenamedequipment. AnyindividualwithinMiCOMLabsisauthorizedtoactonourbehalfandtake actionontheapplication. WedeclarethatMiCOMLabsInc,575BoulderCourt,Pleasanton,California 94566,USA,isallowedtoforwardallinformationrelatedtotheapprovalproject totheFederalCommunicationCommissionandtodiscussanyissues concerningtheapprovalapplication.AnyandallactscarriedoutbyMiCOMLabs onourbehalfshallhavethesameeffectasactsofourown. Name:MinMoDate:Jan.07,2020 Title:Manager Signatureofapplicant:

Cover Letter(s)

ModelDifferenceDeclaration ToWhomItMayConcern, We,ShenzhenGoldenRockTechnologyCo.,Ltd. Product:EXOvaultmouse Trademark:N/A ModelNumber:Mouse01,Mouse02,Mouse03,Mouse04 Allmodel’sthefunction,softwareandelectriccircuitarethesame,onlywitha productcolorandmodelnameddifferent.Testsamplemodel:Mouse01. Pleasecontactmeifyouhaveanyquestion. <Signature> : Name :MinMo Title : Manager Company : ShenzhenGoldenRockTechnologyCo.,Ltd.

Cover Letter(s)

CertificationServiceAgreement CertificationServiceAgreement Introduction ThisCertificationServiceAgreementwaswrittentocovertheScopeofServiceandClient Responsibilitiesforthecountires/domainsthatMiCOMLabscanissuecompliancecertificatesunderits ISO17065accreditationstatus–USA(FCC),Canada(ISED),Japan(MIC)andEuropeanUnion. BysigningthisdocumentitremovestheneedtouploadaServiceAgreementdocumentforeachnew tracker(application). GeneralRequirements ThisServiceAgreementcoverstherequirementsofthefollowingfourcertificationschemesasoperatedbyMiCOM LabsCertification; CountryRecognitionBodyDesignationIdentificationNo. USAFederalCommunicationsCommission(FCC)TCBUS0159 CanadaCanadaISEDFCBUS0159 JapanMIC(MinistryofInternalAffairsandCommunication)RCBR210 EuropeEuropeanCommissionNBNB2280 1.Thecertificationholder/granteeacknowledgesandagreestothefollowing;- (a)alwaysfulfillsthecertificationrequirements,includingimplementingappropriatechangeswhentheyare communicatedbyMiCOMLabs; (b)ensurestheproductforwhichaCertificateisissuedalwaysfulfilstheproductcompliancerequirements underthecertificationschemeandthatallongoingproductionofthecertifiedproductcontinuestofulfillthe productrequirementsandagreesthatiftheconditionsunderwhichtheCertificationwasissuedarenot met,thattheCertificationwillnotbevalidandwillberevoked; (c)makesallnecessaryarrangementsfor: 1)theconductoftheevaluationandsurveillance(ifrequired),includingprovisionforexamining documentationandrecords,andaccesstotherelevantequipment,location(s),area(s),personnel, andcertificationholder/grantee'ssubcontractors; 2)investigationofcomplaints; 3)theparticipationofobservers,ifapplicable; (d)makesclaimsregardingcertificationconsistentwiththescopeofcertification; (e)doesnotuseitsproductcertificationinsuchamannerastobringMiCOMLabsintodisreputeanddoesnot makeanystatementregardingitsproductcertificationthatMiCOMLabsmayconsidermisleadingor unauthorized; (f)uponsuspension,withdrawal,orterminationofcertification,thecertificationholder/granteediscontinuesits useofalladvertisingmatterthatcontainsanyreferencetheretoandtakesactionasrequiredbythe certificationscheme(e.g.thereturnofcertificationdocuments)andtakesanyotherrequiredmeasures; MiCOMLabs,575BoulderCourt,Pleasanton,CA94566 Tel:+1(925)462-0304,Fax:+1(925)462-0306,Web:www.micomlabs.com Page 1of7Doc#:SingleCertificationServiceAgreementRev1.0 CertificationServiceAgreement (g)ifthecertificationholder/granteeprovidescopiesofthecertificationdocumentstoothers,thedocuments shallbereproducedintheirentiretyorasspecifiedinthecertificationscheme; (h)inmakingreferencetoitsproductcertificationincommunicationmediasuchasdocuments,brochuresor advertising,thecertificationholder/granteecomplieswiththerequirementsofMiCOMLabsoras specifiedbythecertificationscheme; (i)complieswithanyrequirementsthatmaybeprescribedinthecertificationschemerelatingtotheuseof marksofconformity,andthatconformitymarksareonlyonspecificproductsfoundtocomplywiththe requirements,andoninformationrelatedtotheproduct; (j)keepsarecordofallcomplaintsmadeknowntoitrelatingtocompliancewithcertificationrequirementsand makestheserecordsavailabletoMiCOMLabswhenrequested,and: 1)takesappropriateactionwithrespecttosuchcomplaintsandanydeficienciesfoundinproducts thataffectcompliancewiththerequirementsforcertification. 2)documentstheactionstaken. 2.MiCOMLabswillissueCertificationthatisvalidforthespecifiedequipmentasitispresentedatthetimeof certification.Thecertificationholder/granteewillinformMiCOMLabs,withoutdelay,ofchangesthatmay affectitsabilitytoconformwithanyoftherequirementsunderthecertificationscheme. Someexamplesofthismaybe,butareinnowaylimitedtothefollowing;- Productmodifications;Changesinthechassismaterial,chassisgasketmethodology/material,grounding, antennagain,antennatype,shieldingmaterial,modificationoftransmissionslines,changestotransmissionline matchingcircuitry,operatingdutycycle,changeofproductusage,operatingfrequency,bandwidth,transmit power/EIRP); Changesto;theLegal,commercial,organizationalstatus;contactaddressandproductionsites. Suchmodificationsshallrequireadditionalapprovalintheformofareviewandamendmenttotheoriginal productcertificationandchangestotheproductcertificationrecordsincludingthecertificate. 3.MiCOMLabsshallexercisethecontrolasspecifiedbythecertificationschemeoverownership,useanddisplayof licenses,certificates,marksofconformity,andanyothermechanismsforindicatingaproductiscertified. Incorrectreferencestothecertificationscheme,standardsormisleadinguseoflicenses,certificates,marks,or anyothermechanismforindicatingaproductiscertified,foundindocumentationorotherpublicity,shallbedealt withbysuitableactionbyMiCOMLabsand/ortheappropriateregulatoryauthority. 4.Confidentiality-MiCOMLabswillholdallformsanddocumentsthatmakeupthecertificationapplication confidentialandwillnotreleaseanyinformationtothirdpartieswithoutwrittenconsentfromtheapplicant. MiCOMLabs,575BoulderCourt,Pleasanton,CA94566 Tel:+1(925)462-0304,Fax:+1(925)462-0306,Web:www.micomlabs.com Page2of7Doc#:SingleCertificationServiceAgreementRev1.0 CertificationServiceAgreement GeneralTermsandConditions: DOCUMENTATION Documentationrequiredforevaluationofthecertificationapplicationmustbeprovidedinitsentirety.Technical evaluationoftheapplicationwillnotbeginuntilalloftherequireddocumentationismadeavailabletoMiCOMLabs. Applicantagreestobefullyliableforthequalityandaccuracyoftheapplicationandalldocumentationprovidedfor certificationpurposes. Requestsforadditionalapplicationdocumentation(corrected/additionalforms;attestationletters,application exhibits,technicalinformation,etc)shallbedeliveredtoMiCOMwithin60daysoftherequest.Failuretoprovide therequesteddocumentationwithinthistimeframemayresultindismissalofthecertificationapplicationormay incurthefullfee. ElectronicSignatures MiCOMLabs,Inc.usesaneventdrivencloudbasedsystemtomanagecertificationprograms.Client electronicsignaturesmaybeusedonanasneededbasisatkeystagesinthecertificationprocessasarecord ofagreement/acknowledgementonapplicationandcertificationdetails. Iack…

Text truncated - open the document above for the full version.

External Photos

Model:Mouse01 Model:Mouse01 Model:Mouse01

ID Label/Location Info

FCCIDLABEL: LabelLocation: FCCID:2AO78-MICE01 Productname:EXOvaultmouse ModelNo.:Mouse01 ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothe followingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference (2)Thisdevicemustacceptanyinterferencereceived,includinginterferencethat maycauseundesiredoperation. Long:3cm Width:2cm

Internal Photos

Model:Mouse01 Model:Mouse01 Model:Mouse01 Model:Mouse01 BLEAntenna

Test Report

Page1of24ReportNo.:UNIA19121711ER-02 FCCRADIOTESTREPORT FCCID:2AO78-MICE01 Product : EXOvaultmouse TradeName: N/A ModelName : Mouse01 SerialModel: Mouse02,Mouse03,Mouse04 ReportNo. : UNIA19121711ER-02 Preparedfor ShenzhenGoldenRockTechnologyCo.,Ltd. Room#338,3/F,HuafengBuilding,41District,XinanStreet,BaoanDistrict, Shenzhen,China Preparedby ShenzhenUnitedTestingTechnologyCo.,Ltd. 2F,AnnexBldg,JiahuangyuanTechPark,#365Baotian1Rd,Tiegang Community,XixiangStr,Bao'anDistrict,Shenzhen,China Page2of24ReportNo.:UNIA19121711ER-02 TESTRESULTCERTIFICATION Applicant’sname....................: ShenzhenGoldenRockTechnologyCo.,Ltd. Address......................................: Room#338,3/F,HuafengBuilding,41District,XinanStreet,Baoan District,Shenzhen,China Manufacture'sName..............: ShenzhenGoldenRockTechnologyCo.,Ltd. Address......................................: Room#338,3/F,HuafengBuilding,41District,XinanStreet,Baoan District,Shenzhen,China Productdescription Productname............................... : EXOvaultmouse TradeMark ................................. : N/A Modeland/ortypereference.: Mouse01,Mouse02,Mouse03,Mouse04 Standards..................................: FCCRulesandRegulationsPart15SubpartCSection15.249, ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedbyShenzhenUnitedTestingTechnology Co.,Ltd.,andthetestresultsshowthattheequipmentundertest(EUT)isincompliance withtheFCCrequirements.Anditisapplicableonlytothetestedsampleidentifiedinthe report. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofUNI,this documentmaybealteredorrevisedbyShenzhenUnitedTestingTechnologyCo.,Ltd., personnelonly,andshallbenotedintherevisionofthedocument. DateofTest...............................................: Date(s)ofperformanceoftests...............: Dec.17,2019~Jan.07,2020 DateofIssue .............................................. : Jan.07,2020 TestResult..................................................:Pass Preparedby: Kahnyang/Editor Reviewer: SherwinQian/Supervisor Approved&AuthorizedSigner: Liuze/Manager Page3of24ReportNo.:UNIA19121711ER-02 TableofContentsPage 1.TESTSUMMARY4 2.GENERALINFORMATION5 2.1GENERALDESCRIPTIONOFEUT5 2.2CarrierFrequencyofChannels6 2.3OperationofEUTduringtesting6 2.4DESCRIPTIONOFTESTSETUP6 2.5MEASUREMENTINSTRUMENTSLIST7 3.CONDUCTEDEMISSIONSTEST8 3.1ConductedPowerLineEmissionLimit8 3.2TestSetup8 3.3TestProcedure8 3.4TestResult8 4RADIATEDEMISSIONTEST11 4.1RadiationLimit11 4.2TestSetup11 4.3TestProcedure12 4.4TestResult13 5BANDEDGE18 5.1Limits18 5.2TestProcedure18 5.3TestResult18 6OCCUPIEDBANDWIDTHMEASUREMENT20 6.1TestSetup20 6.2TestProcedure20 6.3MeasurementEquipmentUsed20 6.4TestResult20 7ANTENNAREQUIREMENT22 8PHOTOGRAPHOFTEST23 8.1RadiatedEmission23 8.2ConductedEmission24 Page4of24ReportNo.:UNIA19121711ER-02 1.TESTSUMMARY TESTPROCEDURESANDRESULTS DESCRIPTIONOFTESTRESULTSTANGARD CONDUCTEDEMISSIONSTEST COMPLIANTFCCPart15.207 RADIATEDEMISSIONTESTCOMPLIANTFCCPart15.209/15.249 BANDEDGECOMPLIANTFCCPart15.249(d) OCCUPIEDBANDWIDTHMEASUREMENTCOMPLIANTFCCPart15.215 ANTENNAREQUIREMENTCOMPLIANTFCCPart15.203 TESTFACILITY TestFirm:ShenzhenUnitedTestingTechnologyCo.,Ltd. Address:2F,AnnexBldg,JiahuangyuanTechPark,#365Baotian1Rd,Tiegang Community,XixiangStr,Bao'anDistrict,Shenzhen,China Thetestingqualityabilityofourlaboratorymeetwith"QualityLawofPeople'sRepublicof China"Clause19.ThetestingqualitysystemofourlaboratorymeetswithISO/IEC-17025 requirements.ThisapprovalresultisacceptedbyMRAofAPLAC. Ourtestfacilityisrecognized,certified,oraccreditedbythefollowingorganizations: A2LACertificateNumber:4747.01 TheEMCLaboratoryhasbeenaccreditedbyA2LA,andincompliancewithISO/IEC 17025:2017GeneralRequirementsfortestingLaboratories. FCCRegistrationNumber:674885 TheEMCLaboratoryhasbeenregisteredandfullydescribedinareportfiledwiththe(FCC) FederalCommunicationscommission. ICRegistrationNumber:21947 TheEMCLaboratoryhasbeenregisteredandfullydescribedinareportfiledwiththe(IC) IndustryCanada. MEASUREMENTUNCERTAINTY MeasurementUncertainty ConductedEmissionExpandedUncertainty=2.23dB,k=2 Radiatedemissionexpandeduncertainty(9kHz-30MHz)= 3.08dB,k=2 Radiatedemissionexpandeduncertainty(30MHz-1000MHz)= 4.42dB,k=2 Radiatedemissionexpandeduncertainty(Above1GHz)= 4.06dB,k=2 Page5of24ReportNo.:UNIA19121711ER-02 2.GENERALINFORMATION 2.1GENERALDESCRIPTIONOFEUT Equipment EXOvaultmouse TradeMarkN/A ModelName Mouse01 SerialNo. Mouse02,Mouse03,Mouse04 ModelDifference Allmodel’sthefunction,softwareandelectriccircuitare thesame,onlywithaproductcolorandmodelnamed different.Testsamplemodel:Mouse01. FCCID2AO78-MICE01 AntennaType PCBAntenna AntennaGain1dBi FrequencyRange2402~2480MHz NumberofChannels 40CH ModulationTypeGFSK Battery 3.7V650mAh PowerSourceAC100-240V~50/60Hz Page6of24ReportNo.:UNIA19121711ER-02 2.2CarrierFrequencyofChannels ChannelList Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 012402112422212442312462 022404122424222444322464 032406132426232446332466 042408142428242448342468 052410152430252450352470 062412162432262452362472 072414172434272454372474 082416182436282456382476 092418192438292458392478 102420202440302460402480 2.3OperationofEUTduringtesting OperatingMode Themodeisused:Transmittingmode LowChannel:2402MHz MiddleChannel:2442MHz HighChannel:2480MHz 2.4DESCRIPTIONOFTESTSETUP OperationofEUTduringConductedtesting: OperationofEUTduringRadiationtesting: Tableforauxiliaryequipment: EquipmentDescriptionManufacturerModelCalibrationDueDate AdapterHUAWEIHW-050200C01N/A Adapter EUT EUT ACPower Page7of24ReportNo.:UNIA19121711ER-02 2.5MEASUREMENTINSTRUMENTSLIST ItemEquipmentManufacturerModelNo.SerialNo.Calibrateduntil CONDUCTEDEMISSIONSTEST 1AMNSchwarzbeckNNLK812181213702020.09.06 2AMNETS3810/2000201992020.09.06 3 EMITEST RECEIVER Rohde&SchwarzESCI1012102020.09.06 4AANTESEQT8-Cat6388882020.09.06 RADIATEDEMISSIONTEST 1HornAntennaSunolDRH-118A1014152020.09.06 2BicoNILogAntennaSunolJB1AntennaA0902152020.09.06 3PREAMPHP8449B3008A001602020.09.06 4PREAM…

Text truncated - open the document above for the full version.

Test Report

Page1of24ReportNo.:UNIA19121711ER-01 FCCRADIOTESTREPORT FCCID:2AO78-MICE01 Product : EXOvaultmouse TradeName: N/A ModelName : Mouse01 SerialModel: Mouse02,Mouse03,Mouse04 ReportNo. : UNIA19121711ER-01 Preparedfor ShenzhenGoldenRockTechnologyCo.,Ltd. Room#338,3/F,HuafengBuilding,41District,XinanStreet,BaoanDistrict, Shenzhen,China Preparedby ShenzhenUnitedTestingTechnologyCo.,Ltd. 2F,AnnexBldg,JiahuangyuanTechPark,#365Baotian1Rd,Tiegang Community,XixiangStr,Bao'anDistrict,Shenzhen,China Page2of24ReportNo.:UNIA19121711ER-01 TESTRESULTCERTIFICATION Applicant’sname....................: ShenzhenGoldenRockTechnologyCo.,Ltd. Address......................................: Room#338,3/F,HuafengBuilding,41District,XinanStreet,Baoan District,Shenzhen,China Manufacture'sName..............: ShenzhenGoldenRockTechnologyCo.,Ltd. Address......................................: Room#338,3/F,HuafengBuilding,41District,XinanStreet,Baoan District,Shenzhen,China Productdescription Productname............................... : EXOvaultmouse TradeMark ................................. : N/A Modeland/ortypereference.: Mouse01,Mouse02,Mouse03,Mouse04 Standards..................................: FCCRulesandRegulationsPart15SubpartCSection15.249, ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedbyShenzhenUnitedTestingTechnology Co.,Ltd.,andthetestresultsshowthattheequipmentundertest(EUT)isincompliance withtheFCCrequirements.Anditisapplicableonlytothetestedsampleidentifiedinthe report. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofUNI,this documentmaybealteredorrevisedbyShenzhenUnitedTestingTechnologyCo.,Ltd., personnelonly,andshallbenotedintherevisionofthedocument. DateofTest...............................................: Date(s)ofperformanceoftests...............: Dec.17,2019~Jan.07,2020 DateofIssue .............................................. : Jan.07,2020 TestResult..................................................:Pass Preparedby: Kahnyang/Editor Reviewer: SherwinQian/Supervisor Approved&AuthorizedSigner: Liuze/Manager Page3of24ReportNo.:UNIA19121711ER-01 TableofContentsPage 1.TESTSUMMARY4 2.GENERALINFORMATION5 2.1GENERALDESCRIPTIONOFEUT5 2.2CarrierFrequencyofChannels6 2.3OperationofEUTduringtesting6 2.4DESCRIPTIONOFTESTSETUP6 2.5MEASUREMENTINSTRUMENTSLIST7 3.CONDUCTEDEMISSIONSTEST8 3.1ConductedPowerLineEmissionLimit8 3.2TestSetup8 3.3TestProcedure8 3.4TestResult8 4RADIATEDEMISSIONTEST11 4.1RadiationLimit11 4.2TestSetup11 4.3TestProcedure12 4.4TestResult13 5BANDEDGE18 5.1Limits18 5.2TestProcedure18 5.3TestResult18 6OCCUPIEDBANDWIDTHMEASUREMENT20 6.1TestSetup20 6.2TestProcedure20 6.3MeasurementEquipmentUsed20 6.4TestResult20 7ANTENNAREQUIREMENT22 8PHOTOGRAPHOFTEST23 8.1RadiatedEmission23 8.2ConductedEmission24 Page4of24ReportNo.:UNIA19121711ER-01 1.TESTSUMMARY TESTPROCEDURESANDRESULTS DESCRIPTIONOFTESTRESULTSTANGARD CONDUCTEDEMISSIONSTEST COMPLIANTFCCPart15.207 RADIATEDEMISSIONTESTCOMPLIANTFCCPart15.209/15.249 BANDEDGECOMPLIANTFCCPart15.249(d) OCCUPIEDBANDWIDTHMEASUREMENTCOMPLIANTFCCPart15.215 ANTENNAREQUIREMENTCOMPLIANTFCCPart15.203 TESTFACILITY TestFirm:ShenzhenUnitedTestingTechnologyCo.,Ltd. Address:2F,AnnexBldg,JiahuangyuanTechPark,#365Baotian1Rd,Tiegang Community,XixiangStr,Bao'anDistrict,Shenzhen,China Thetestingqualityabilityofourlaboratorymeetwith"QualityLawofPeople'sRepublicof China"Clause19.ThetestingqualitysystemofourlaboratorymeetswithISO/IEC-17025 requirements.ThisapprovalresultisacceptedbyMRAofAPLAC. Ourtestfacilityisrecognized,certified,oraccreditedbythefollowingorganizations: A2LACertificateNumber:4747.01 TheEMCLaboratoryhasbeenaccreditedbyA2LA,andincompliancewithISO/IEC 17025:2017GeneralRequirementsfortestingLaboratories. FCCRegistrationNumber:674885 TheEMCLaboratoryhasbeenregisteredandfullydescribedinareportfiledwiththe(FCC) FederalCommunicationscommission. ICRegistrationNumber:21947 TheEMCLaboratoryhasbeenregisteredandfullydescribedinareportfiledwiththe(IC) IndustryCanada. MEASUREMENTUNCERTAINTY MeasurementUncertainty ConductedEmissionExpandedUncertainty=2.23dB,k=2 Radiatedemissionexpandeduncertainty(9kHz-30MHz)= 3.08dB,k=2 Radiatedemissionexpandeduncertainty(30MHz-1000MHz)= 4.42dB,k=2 Radiatedemissionexpandeduncertainty(Above1GHz)= 4.06dB,k=2 Page5of24ReportNo.:UNIA19121711ER-01 2.GENERALINFORMATION 2.1GENERALDESCRIPTIONOFEUT Equipment EXOvaultmouse TradeMarkN/A ModelName Mouse01 SerialNo. Mouse02,Mouse03,Mouse04 ModelDifference Allmodel’sthefunction,softwareandelectriccircuitare thesame,onlywithaproductcolorandmodelnamed different.Testsamplemodel:Mouse01. FCCID2AO78-MICE01 AntennaType PCBAntenna AntennaGain1dBi FrequencyRange2402~2480MHz NumberofChannels 40CH ModulationTypeGFSK Battery 3.7V650mAh PowerSourceAC100-240V~50/60Hz Page6of24ReportNo.:UNIA19121711ER-01 2.2CarrierFrequencyofChannels ChannelList Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 012402112422212442312462 022404122424222444322464 032406132426232446332466 042408142428242448342468 052410152430252450352470 062412162432262452362472 072414172434272454372474 082416182436282456382476 092418192438292458392478 102420202440302460402480 2.3OperationofEUTduringtesting OperatingMode Themodeisused:Transmittingmode LowChannel:2402MHz MiddleChannel:2440MHz HighChannel:2480MHz 2.4DESCRIPTIONOFTESTSETUP OperationofEUTduringConductedtesting: OperationofEUTduringRadiationtesting: Tableforauxiliaryequipment: EquipmentDescriptionManufacturerModelCalibrationDueDate AdapterHUAWEIHW-050200C01N/A Adapter EUT EUT ACPower Page7of24ReportNo.:UNIA19121711ER-01 2.5MEASUREMENTINSTRUMENTSLIST ItemEquipmentManufacturerModelNo.SerialNo.Calibrateduntil CONDUCTEDEMISSIONSTEST 1AMNSchwarzbeckNNLK812181213702020.09.06 2AMNETS3810/2000201992020.09.06 3 EMITEST RECEIVER Rohde&SchwarzESCI1012102020.09.06 4AANTESEQT8-Cat6388882020.09.06 RADIATEDEMISSIONTEST 1HornAntennaSunolDRH-118A1014152020.09.06 2BicoNILogAntennaSunolJB1AntennaA0902152020.09.06 3PREAMPHP8449B3008A001602020.09.06 4PREAM…

Text truncated - open the document above for the full version.

Test Setup Photos

Model:Mouse01 Model:Mouse01

Contact Information

Applicant

Min Mo
[email protected]+86-755-29095866Fax: +86-755-27162868

Technical Contact

Shenzhen Golden Rock Technology Co., Ltd.
[email protected]

China

Test Firm

Shenzhen United Testing Technology Co., Ltd.Liu Ze
[email protected]86-755-86180996

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-