
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Copryright 2017 数码人公司保留对本资料修改的权利 1 1 U位资产智能管理系统说明书 U-level Assets Management Manual V3.2 深圳市数码人技术有限公司 ShenZhen Digitalor Technologies Co., Ltd. 版权所有 侵权必究 All rights reserve Copryright 2017 数码人公司保留对本资料修改的权利 2 2 前言/preface. 感谢您使用深圳数码人技术公司生产的U位资产管理系统。本系统是数码人技术公司原创 发明的MC-RFID物联网传感器系统,突破了传统RFID技术的局限性,彻底解决了RFID定位的精确 性、U位场景可靠性、数据准确性这三大难题,实现了100%的数据准确性,具有高可靠、免维护、 全生命周期低成本等特点。 Thank you for choosing the U-level Assets Management System produced by ShenZhen Digitalor Technologies Company. This system is an MC-RFID IOT sensor that is original invention by Digitalor, it had breakthrough on the traditional RFID technology, solved thoroughly these problems-accuracy of RFID label position, reliability of server scene and accuracy of data, which has achieved 100% data accuracy, with high reliability, maintenance-free and low cost of the whole life cycle. 是目前业界最具有规模化和商业价值的产品。 At present, this is most large-scale and commercial products in the industry. 美国专利授权号/US Patent:US9633 235 B2 本说明书对U位资产智能监控系统的安装运行,以及应用环境进行了详细的介绍.在安装前 请详细阅读此说明书,以便安全正确使用。 This manual provides a detailed introduction for installation, operation and application environment of U-level Assets Management System. Please read carefully the instruction before installation so that it can be operation safely. 公司网址:http://www.digitalor.com 联系电话:Shenzhen +86-755-86656491 Beijing +86-010-82313100 US +1-223456623 Copryright 2017 数码人公司保留对本资料修改的权利 3 3 目录/Catalog 1. 序言/ Foreword..................................................................................................4 1.1 开箱检查/Checking..........................................................................................4 1.2 安装注意事项/Security.....................................................................................4 2. 安装和运行示意图/Installation & schematic.......................................................4 2.1 安装示意图/ Installation...................................................................................4 2.2 RFID标签安装/Labeling the UTAG..................................................................5 2.3 组网和运行示意图/Network & operation.........................................................5 3. 相关技术标准/ Related standards.......................................................................6 4. 规格参数及环境要求/ Specification parameters & environmental requirements.7 4.1 电气参数/ Electrical parameters........................................................................7 4.2 环境要求/ Environmental requirements............................................................8 5. 维护/Maintenance...............................................................................................8 6. 包装清单以及数量/Packing lists & quantity.........................................................8 7. 有毒有害物质含量表/ RoSH 6 category................................................................8 Copryright 2017 数码人公司保留对本资料修改的权利 4 4 1.序言/Foreword 1.1 开箱检查/Checking 在开箱前,请认真检查外包装箱是否有破损现象,内包装箱内零配件是否与包装清单相符, 如您有任何疑惑请速与供货商或者我公司联系解决! Please be careful checking outside box if there is any damage. Ensure the quantity of the parts is matched with the packing lists in the inner boxes. Please contact with supplier or our company if you have any confuse. 1.2 安装注意事项/Security 必须是贵公司已经授权的人才能安装此产品,并且确保机柜已经可靠接地,否则有触电 的危险。 The operators for installation must be authorized by your company, and ensure the rack is reliable on the electrical grounding, or it may cause electrical shock. 2.安装和运行示意图/ Installation & schematic 2.1 安装示意图/ Installation Copryright 2017 数码人公司保留对本资料修改的权利 5 5 2.2 RFID标签安装/Installation of RFID label 2.2.1 安装RFID标签前,需要确认粘胶位置已经清洁干净,最好是用酒精擦拭设备表 面,以确保能粘贴牢固。 You need to make sure that the position to stick UTAG is clean, it is best to wipe the surface of servers with alcohol to make sure it is securely pasted. 2.3 组网和运行示意图/ Network & operation Copryright 2017 数码人公司保留对本资料修改的权利 6 6 3. 相关技术标准/Related standards 标准/Standard 标准内容/Contents GB 50348-2004 安全防范工程技术规范/Technical specification for safety protection engineering. GB 50396-2007 出入口控制系统工程设计规范/code of design for access control systems engineering. GB 50174-2008 电子信息系统机房设计规范/Code for design of electronic information system room. EN55022:2006 信息技术设备-无线电干扰特性-限制和测量方法/ Information technology equipment — Radio disturbance characteristics —Limits and methods of measurement IEC 60950-1 信息技术设备的安全 第1部分:一般要求 /Information technology equipment – Safety. Part 1: General requirements IEC61000-4-6 电磁兼容性(EMC).第4-6部分:测试和测量技术.射频场感应的传导 干扰抗扰性./Electromagnetic compatibility(EMC)-Part 4-6: Testing and measurement techniques-Immunity to conducted disturbances, induced by radio-frequency fields. IEC61000-4-5 电磁兼容性(EMC).第4-5部分:试验和测量/Electromagnetic compatibility(EMC)-Part4-5: Testing and measurement techniques -Surge immunity test IEC61000-4-4 试验和测量技术-电快速瞬变脉冲群抗扰度试验/Electromagnetic compatibility(EMC)-Part 4-4: Testing and measurement techniques-Electrical fast transient /burst immunity test. RED 2014/53/EU 欧洲无线产品认证/CE RED Certificate 91/263/EEC 电信终端设备CE认证/Telecommunications Terminal Equipment CE Copryright 2017 数码人公司保留对本资料修改的权利 7 7 4. 规格参数及环境要求/Specification parameters & environmental requirements 4.1 规格参数/ Specification parameters 项目/Item 规格描述/Specification 输入电压/Input voltage 12V /24V DC 输入电流/Input current < 0.02A (Note: One block) 42U平均功耗/Average power consumption for 42U ≤2W 上行通信方式/Upload Communication mode RS485 下行通信方式/Down Communication mode RS485 USART U位数量/ U quantity of one block 6U 工作频率/Frequency 13.56MHZ 标签与模块的数据通信方式/ Communication mode RFID非接触式/RFID non-contact RFID读取方式/Read ways 自动读取/Auto-read 标签读取距离/Distance for reading < 20mm 标签与U位模块固定方式/Fixing module with RFID 磁力吸附/Magnet 散热要求/Cooling 自然散热/Room cooling 防护等级/Protection class IP50 外形尺寸/Dimension 267 x 27 x 12 mm 重量/Weight 150±5g 外壳材质/Material PC阻燃材料/ Flame retardant PC 颜色/Color 黑色/Black Copryright 2017 数码人公司保留对本资料修改的权利 8 8 4.2 环境要求/ Environmental requirements 应用参数/Parameter 使用条件/ Application 运输条件/ Transportation 贮存条件/ Storage 备注/ Remark 项目/Item 单位/Unit m m 温度/ Temperature °C -20 -40 -40 / °C +55 +70 +70 湿度/ Humidity % 5 / 5 / % 95 …
Text truncated - open the document above for the full version.
Shenzhen Digitalor Technology Co. Ltd. Add: Room305-2, Shen zhen IC Design&ApplicationIndustril Park, No.1089, Chaguang Rd, Nanshan District, Shenzhen, China Tel: +8615919803961 Fax: / Date: 2020-06-11 Dear Sir/Madam, We, Shenzhen Digitalor Technology Co. Ltd. Hereby declares the following statement for FCC, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: U-level Assets Management Module Model no.: UR5000-MT-6, UR5000-SL-6, UR5000-SL-5 Sincerely, (Signed) Name / Title: Yi Lu / Manager Company: Shenzhen Digitalor Technology Co. Ltd. Address: Room305-2, Shen zhen IC Design&ApplicationIndustril Park, No.1089, Chaguang Rd, Nanshan District, Shenzhen, China Phone: +8615919803961 Fax: / E-Mail: [email protected]
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 <2020-06-11> TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AOFJ-UR5000-MT-6 UR5000-MT-6 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, (Signed) Name / Title: Yi Lu / Manager Company: Shenzhen Digitalor Technology Co. Ltd. Address: Room305-2, Shen zhen IC Design&ApplicationIndustril Park, No.1089, Chaguang Rd, Nanshan District, Shenzhen, China Phone: +8615919803961 Fax: / E-Mail: [email protected]
Shenzhen Digitalor Technology Co. Ltd. Room305-2, Shen zhen IC Design&ApplicationIndustril Park, No.1089, Chaguang Rd, Nanshan District, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2020/06/11 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2AOFJ-UR5000-MT-6 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, (Signed) Name / Title: Yi Lu / Manager Company: Shenzhen Digitalor Technology Co. Ltd. Address: Room305-2, Shen zhen IC Design&ApplicationIndustril Park, No.1089, Chaguang Rd, Nanshan District, Shenzhen, China Phone: +8615919803961 Fax: / E-Mail: [email protected]
FCC ID:2AOFJ-UR5000-MT-6 FCC ID:2AOFJ-UR5000-MT-6 FCC ID:2AOFJ-UR5000-MT-6 FCC ID:2AOFJ-UR5000-MT-6
_____________________________________________________________________________________________________ LABEL AND LOCATION (Size: L4.0cm x 2.0cm) Label Location FCC Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Statement Location
FCCID:2AOFJ-UR5000-MT-6 Antenna FCCID:2AOFJ-UR5000-MT-6
Shenzhen Global Test Service Co.,Ltd. No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road, Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong FCC PART 15 SUBPART C TEST REPORT FCC PART 15 C (15.225) Report Reference No. .................... : FCC ID. ........................................... : GTS20200512007-1-1 2AOFJ-UR5000-MT-6 Compiled by ( position+printed name+signature) . : File administrators Tracy Hu Supervised by ( position+printed name+signature) . : Test Engineer Moon Tan Approved by ( position+printed name+signature) . : Manager Simon Hu Date of issue .................................... : May. 16, 2020 Representative Laboratory Name . : Shenzhen Global Test Service Co.,Ltd. Address ............................................ : No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road, Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong Applicant’s name............................ : Shenzhen Digitalor Technology Co., Ltd Address ............................................ : Room305-2, Shen zhen IC Design&ApplicationIndustril Park, No.1089, Chaguang Rd, Nanshan District, Shenzhen, China Test specification ........................... : Standard ........................................... : FCC Part 15 C (15.225) TRF Originator .................................. : Shenzhen Global Test Service Co.,Ltd. Master TRF ...................................... : Dated 2014-12 Shenzhen Global Test Service Co.,Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Global Test Service Co.,Ltd. is acknowledged as copyright owner and source of the material. Shenzhen Global Test Service Co.,Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : U-level Assets Management Module Trade Mark ....................................... : N/A Manufacturer .................................... : Shenzhen Digitalor Technology Co., Ltd Model/Type reference ...................... : UR5000-MT-6 List Model ........................................ : UR5000-SL-6, UR5000-SL-5 Modulation Type ............................... : ASK Operation Frequency ....................... : 13.56 MHz Hardware Version ............................ : V2.0 Software Version .............................. : V2.0 Rating ............................................... : Adapter 1:Input: 100-240V~50/60Hz 1.0A MAX Output: 12V 2500mA Adapter 2:Input: 100-240V~50/60Hz 2.0A MAX Output: 24V 3A Result ............................................... : PASS Report No.: GTS20200512007-1-1 Page 2 of 25 T E S T R E P O R T Test Report No. : GTS20200512007-1-1 May. 16, 2020 ______________________________________________________________________________________________ Date of issue Equipment under Test : U-level Assets Management Module Model /Type : UR5000-MT-6 List Model : UR5000-SL-6, UR5000-SL-5 Applicant : Shenzhen Digitalor Technology Co., Ltd Address : Room305-2, Shen zhen IC Design&ApplicationIndustril Park, No.1089, Chaguang Rd, Nanshan District, Shenzhen, China Manufacturer : Shenzhen Digitalor Technology Co., Ltd Address : Room305-2, Shen zhen IC Design&ApplicationIndustril Park, No.1089, Chaguang Rd, Nanshan District, Shenzhen, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: GTS20200512007-1-1 Page 3 of 25 Contents 1. TEST STANDARDS ......................................................................................................................................... 4 2. SUMMARY ....................................................................................................................................................... 5 2.1. General Remarks ................................................................................................................................... 5 2.2. Product Description ................................................................................................................................ 5 2.3. Equipment Under Test ........................................................................................................................... 5 2.4. Short description of the Equipment under Test (EUT) ........................................................................... 5 2.5. Block Diagram of Test Setup ................................................................................................................. 5 2.6. Related Submittal(s) / Grant (s) ............................................................................................................. 6 2.7. Special Accessories ............................................................................................................................... 6 2.8. Modifications .......................................................................................................................................... 6 3. TEST ENVIRONMENT ..................................................................................................................................... 7 3.1. Address of the test laboratory ................................................................................................................ 7 3.2. Test Facility ............................................................................................................................................ 7 3.3. Environmental conditions ....................................................................................................................... 7 3.4. Summary of measurement results ............................................…
Text truncated - open the document above for the full version.
FCCID:2AOFJ-UR5000-MT-6 1. Test Setup Photos of the EUT Adapter 1: YS04-120250D FCCID:2AOFJ-UR5000-MT-6 Adapter 2: SK08T-2400300W2 FCCID:2AOFJ-UR5000-MT-6
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |