FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Chengdu Accsoon Technology Co., LTD./
  3. 2AOH401MIC02

2AOH401MIC02ACCSOON CoMo

Chengdu Accsoon Technology Co., LTD.

Application Details

Equipment Class
PUE - Part 15 Unlicensed PCS portable Tx held to ear
Date of Grant
Jul 21, 2024
Application Purpose
Original Equipment
Date of Application
Jul 21, 2024
Equipment Note
ACCSOON CoMo
Frequency Range
1921.53600000 - 1928.44800000
Company
Chengdu Accsoon Technology Co., LTD.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Chengdu Accsoon Technology Co., LTD. 2024-07-02 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID#2AOH401MIC02) [Chengdu Accsoon Technology Co., LTD.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) Zhang Jalen Chengdu Accsoon Technology Co., LTD. 2024-07-02 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID#2AOH401MIC02) [Chengdu Accsoon Technology Co., LTD.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) Zhang Jalen

Attestation Statements

Chengdu Accsoon Technology Co., LTD. Attestation Statements 2024-06-19 TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (FCC ID#2AOH401MIC02) (Chengdu Accsoon Technology Co., LTD. ), the undersigned, hereby authorize (AOGES CO., LIMITED) to act as our designated U.S. agent for service of process, (Chengdu Accsoon Technology Co., LTD.) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. (AOGES CO., LIMITED) accepts the responsibility to act as designated U.S. agent for service of process. Applicant Information: Company name: Chengdu Accsoon Technology Co., LTD. Contact Name: Zhang Jalen Address: Rm. 708, Bld. 1, Xiongchuan Center, No.166, Tianfu 2nd St., High-tech Zone, Chengdu, China Telephone No: +86-13550858379 Email: [email protected] Signature U.S. Agent Information: Company Name: AOGES CO., LIMITED Address: 1624 Market St, Ste 226, #30327 Denver CO, 80202 USA FRN: 0033947847 Contact Name: XIAOYAN LAl Telephone No: +1 303 623 1940 Email: [email protected] Signature

Cover Letter(s)

Differences Description We Chengdu Accsoon Technology Co., LTD. state: Product: ACCSOON CoMo Model Name: MIC02, MIC02-H, MIC02-R, MIC02-1H1R, MIC02-1H2R, MIC02-1H3R, MIC02-1H4R, MIC02-1H5R, MIC02-1H6R, MIC02-1H7R, MIC02-1H8R Trade Name: ACCSOON FCC ID: 2AOH401MIC02 The electrical circuit design, layout, components used and internal wiring for above models are identical, the model is different from the sales area, everything else is exactly the same. Signatory Date 2024.07.02 Signature Name: Zhang Jalen Title: Manager Company: Chengdu Accsoon Technology Co., LTD. Address: Rm. 708, Bld. 1, Xiongchuan Center, No.166, Tianfu 2nd St., High-tech Zone, Chengdu, 610000, China.

Cover Letter(s)

Chengdu Accsoon Technology Co., LTD. 2024-07-02 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (ACCSOON CoMo / MIC02, MIC02-H, MIC02-R, MIC02-1H1R, MIC02-1H2R, MIC02-1H3R, MIC02-1H4R, MIC02- 1H5R, MIC02-1H6R, MIC02-1H7R, MIC02-1H8R # AND FCC ID#2AOH401MIC02) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the • Schematics • Block diagram • Operation description required to be submitted with this application be permanently withheld from public review. These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors.. Please contact me if there is any information you may need. Sincerely, Sincerely, Name: Zhang Jalen Signature:

Cover Letter(s)

Chengdu Accsoon Technology Co., LTD. 2024-07-02 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen STS Test Services Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Name: Zhang Jalen Signature:

Cover Letter(s)

Chengdu Accsoon Technology Co., LTD. 2024-07-02 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Short Term Confidentiality Request For (ACCSOON CoMo / MIC02, MIC02-H, MIC02-R, MIC02-1H1R, MIC02-1H2R, MIC02-1H3R, MIC02-1H4R, MIC02- 1H5R, MIC02-1H6R, MIC02-1H7R, MIC02-1H8R # AND FCC ID#2AOH401MIC02) To Whom It May Concern: In accordance with sections 0.457 and 0.459 of CFR 47, < Chengdu Accsoon Technology Co., LTD. >. requests short-term Confidentiality of following sections of this application for a period of 45 days after grant is issued. Test setup photos External photos Internal photos User’s manual These documents contain detailed system and equipment descriptions and related information about the product, which < Chengdu Accsoon Technology Co., LTD. > considers to be proprietary, confidential, and a custom design and otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, < Chengdu Accsoon Technology Co., LTD. > feels that this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Name: Zhang Jalen Signature:

ID Label/Location Info

Label Size:10*4mm Note:The label is silk-screen on the sample FCC ID: 2AOH401MIC02.

RF Exposure Info

ReportNo.:AGC02787240502AP01 Page 1 of 3 EUTPhotographs Frontside Backside ReportNo.:AGC02787240502AP01 Page 2 of 3 Topside Bottomside ReportNo.:AGC02787240502AP01 Page 3 of 3 Leftside Rightside ----ENDOFREPORT----

RF Exposure Info

CALIBRATIONDATA PROBECALIBRATIONDATA DIPOLECALIBRATIONDATA

RF Exposure Info

Page1of37 SARTestReport ReportNo.:AGC02787240502FH01 FCCID: 2AOH401MIC02 APPLICATIONPURPOSE: OriginalEquipment PRODUCTDESIGNATION: ACCSOONCoMo BRANDNAME: ACCSOON MODELNAME: MIC02 SERIESMODEL MIC02-H,MIC02-R,MIC02-1H1R,MIC02-1H2R,MIC02-1H3R, MIC02-1H4R,MIC02-1H5R,MIC02-1H6R,MIC02-1H7R,MIC02-1H8R APPLICANT: ChengduAccsoonTechnologyCo.,LTD. DATEOFISSUE: May22,2024 STANDARD(S): IEEEStd.1528:2013 FCC47CFRPart2§2.1093 IEEEStdC95.1™-2005 REPORTVERSION: V1.0 AttestationofGlobalCompliance(Shenzhen)Co.,Ltd. ReportNo.:AGC02787240502FH01 Page 2 of 37 ReportReviseRecord ReportVersionReviseTimeIssuedDateValidVersionNotes V1.0/May22,2024ValidInitialRelease ReportNo.:AGC02787240502FH01 Page 3 of 37 TestReport ApplicantNameChengduAccsoonTechnologyCo.,LTD. ApplicantAddress Rm.708,Bld.1,XiongchuanCenter,No.166,Tianfu2ndSt.,High-techZone, Chengdu,610000,China. ManufacturerNameShenzhenAccsoonTechnologyCo.,LTD. ManufacturerAddress Room302,BLDGD,Zhiyuanyungu,73GuanlanBlvd,LonghuaDistrict, Shenzhen,China. FactoryNameShenzhenAccsoonTechnologyCo.,LTD. FactoryAddress Room302,BLDGD,Zhiyuanyungu,73GuanlanBlvd,LonghuaDistrict, Shenzhen,China. ProductDesignationACCSOONCoMo BrandNameACCSOON ModelNameMIC02 SeriesModel MIC02-H,MIC02-R,MIC02-1H1R,MIC02-1H2R,MIC02-1H3R,MIC02-1H4R, MIC02-1H5R,MIC02-1H6R,MIC02-1H7R,MIC02-1H8R DifferentDescriptionThemodelisdifferentfromthesalesarea,everythingelseisexactlythesame EUTVoltage RatedVoltage:3.6V ChargeLimitVoltage: Capacity:2400mAh ApplicableStandard IEEEStd.1528:2013 FCC47CFRPart2§2.1093 IEEEStdC95.1™-2005 DateofreceiptoftestitemMay13,2024 TestDateMay22,2024 ReportTemplateAGCRT-US-4G/SAR(2021-04-20) Note:Theresultsoftestinginthisreportapplytotheproduct/systemwhichwastestedonly. PreparedBy TheaHuang (ProjectEngineer) May22,2024 ReviewedBy CalvinLiu (Reviewer) May22,2024 ApprovedBy MaxZhang (AuthorizedOfficer) May22,2024 ReportNo.:AGC02787240502FH01 Page 4 of 37 TABLEOFCONTENTS 1.SUMMARYOFMAXIMUMSARVALUE...........................................................................................................5 2.GENERALINFORMATION................................................................................................................................6 2.1.EUTDESCRIPTION..........................................................................................................................................6 3.SARMEASUREMENTSYSTEM.........................................................................................................................7 3.1.THESATIMOSYSTEMUSEDFORPERFORMINGCOMPLIANCETESTSCONSISTSOFFOLLOWINGITEMS..................7 3.2.COMOSARE-FIELDPROBE...........................................................................................................................8 3.3.ROBOT............................................................................................................................................................8 3.4.VIDEOPOSITIONINGSYSTEM...........................................................................................................................9 3.5.DEVICEHOLDER..............................................................................................................................................9 3.6.SAMTWINPHANTOM....................................................................................................................................10 4.SARMEASUREMENTPROCEDURE...............................................................................................................11 4.1.SPECIFICABSORPTIONRATE(SAR)...............................................................................................................11 4.2.SARMEASUREMENTPROCEDURE.................................................................................................................12 4.3.RFEXPOSURECONDITIONS...........................................................................................................................14 5.TISSUESIMULATINGLIQUID..........................................................................................................................15 5.1.THECOMPOSITIONOFTHETISSUESIMULATINGLIQUID.....................................................................................15 5.2.TISSUEDIELECTRICPARAMETERSFORHEADANDBODYPHANTOMS...............................................................16 5.3.TISSUECALIBRATIONRESULT.........................................................................................................................17 6.SARSYSTEMCHECKPROCEDURE.............................................................................................................18 6.1.SARSYSTEMCHECKPROCEDURES..............................................................................................................18 6.2.SARSYSTEMCHECK....................................................................................................................................19 7.EUTTESTPOSITION.......................................................................................................................................21 8.SAREXPOSURELIMITS.................................................................................................................................22 9.TESTFACILITY................................................................................................................................................23 10.TESTEQUIPMENTLIST................................................................................................................................24 11.MEASUREMENTUNCERTAINTY..................................................................................................................25 12.CONDUCTEDPOWERMEASUREMENT......................................................................................................28 13.TESTRESULTS.............................................................................................................................................29 13.1.SARTES…

Text truncated - open the document above for the full version.

Test Report

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Radio Test Report Report No.: STS2403171W02 Issued for Chengdu Accsoon Technology Co., LTD. Rm. 708, Bld. 1, Xiongchuan Center, No.166, Tianfu 2nd St., High-tech Zone, Chengdu, 610000, China. Product Name: ACCSOON CoMo Brand Name: ACCSOON Model Name: MIC02 Series Model(s): MIC02-H, MIC02-R, MIC02-1H1R, MIC02- 1H2R, MIC02-1H3R, MIC02-1H4R, MIC02- 1H5R, MIC02-1H6R, MIC02-1H7R, MIC02- 1H8R FCC ID: 2AOH401MIC02 Test Standards: Title 47 of the CFR, Part 15 Subpart D Page 2 of 67 Report No.: STS2403171W02 TEST RESULT Applicant’s Name ................. : Chengdu Accsoon Technology Co., LTD. Address ................................. : Rm. 708, Bld. 1, Xiongchuan Center, No.166, Tianfu 2nd St., High-tech Zone,Chengdu, 610000, China. Manufacturer's Name ........... : Shenzhen Accsoon Technology Co., LTD. Address ................................. : Room 302, BLDG D, Zhiyuanyungu, 73 Guanlan Blvd, Longhua Dis- trict, Shenzhen, China. Product Description Product Name ........................ : ACCSOON CoMo Brand Name ......................... : ACCSOON Model Name .......................... : MIC02 Series Model .......................... : MIC02-H, MIC02-R, MIC02-1H1R, MIC02-1H2R, MIC02-1H3R, MIC02-1H4R, MIC02-1H5R, MIC02-1H6R, MIC02-1H7R, MIC02- 1H8R Test Standards ..................... : Title 47 of the CFR, Part 15. Subpart D Test procedure ........................ : ANSI C63.17-2013 This device described above has been tested by STS and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. The test results presented in this report relate only to the object tested. This report shall not be repro- duced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Date of Test ........................................... : Date of receipt of test item ...................... : 29 Mar. 2024 Date of performance of tests .................. : 29 Mar. 2024 ~ 16 May 2024 Date of Issue .......................................... : 16 May 2024 Test Result .............................................. : Pass Testing Engineer : (Lenon Hou) Technical Manager : (Chris Chen) Authorized Signatory : (Bovey Yang) Page 3 of 67 Report No.: STS2403171W02 TABLE OF CONTENTS Page 1 INTRODUCTION 7 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2 PRODUCT INFORMATION 8 3 TEST CONFIGURATION OF EQUIPMENT UNDER TEST 9 3.1 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 9 3.2 SYSTEM TEST CONFIGURATION 10 4 MEASUREMENT INSTRUMENTS 11 5 TEST ITEMS 12 5.1 ANTENNA REQUIREMENT 12 5.2 MODULATION TECHNIQUES 12 5.3 EMISSION BANDWIDTH 13 5.4 PEAK TRANSMIT POWER 16 5.5 POWER SPECTRAL DENSITY 19 5.6 POWER ADJUSTMENT FOR ANTENNA GAIN 22 5.7 AUTOMATICALLY DISCONTINUE TRANSMISSION 23 5.8 SYSTEM ACKNOWLEDGE-MENT TEST 24 5.9 MONITORING THRESHOLD 25 5.10 DURATION OF TRANSMISSION 26 5.11 SELECTED CHANNEL CONFIRMATION, POWER ACCURACY, SEGMENT OCCUPANCY 27 5.12 RANDOM WAITING 29 5.13 MONITORING REQUIREMENTS 30 5.14 MONITORING ANTENNA 31 5.15 DUPLEX CONNECTIONS 31 5.16 ALTERNATIVE MONITORING INTERVAL FOR CO-LOCATED DEVICES 32 5.17 FAIR ACCESS 32 5.18 SPURIOUS EMISSIONS 33 5.19 FRAME PERIOD 41 5.20 FREQUENCY STABILITY 42 5.21 CONDUCTED EMISSION MEASUREMENT 44 5.22 RADIATED SPURIOUS EMISSION 48 Page 4 of 67 Report No.: STS2403171W02 Revision History Rev. Issue Date Report No. Effect Page Contents 00 16 May 2024 STS2403171W02 ALL Initial Issue Page 5 of 67 Report No.: STS2403171W02 SUMMARY OF TEST RESULTS Test procedures according to the technical standards: The following tests were conducted on a sample of the equipment for the purpose of demonstrating com- pliance with Part 15 Subpart D. Requirement FCC Part Test Procedure Result Emission Bandwidth 15.323 (a) 6.1.3 Compliant Labeling Requirements 15.19(a)(3) -- Compliant Conducted Emissions 15.315 & 15.207 ANSI C63.4 Compliant Antenna Requirements 15.317 & 15.203 Declaration Compliant Use digital modulation 15.319 (b) 6.1.4 Compliant Peak transmit power 15.319 (c) 6.1.2 Compliant Power spectral density 15.319 (d) 6.1.5 Compliant Power adjustment for an- tenna gain 15.319 (e) 4.3.1 Compliant Automatically dis- continue transmis- sion 15.319 (f) -- Compliant Spurious emissions conducted 15.323 (d) (1) & 15.323 (d) (2) 6.1.6 Compliant RF Exposure 15.319 (i) & 1.1307(b), 2.1091 and 2.1093 ANSI/IEEE C95.1 Compliant (The test data please refer to RF exposure report) Monitoring time 15.323 (c)(1) 7.3.4 Compliant Monitoring thresh- old 15.323 (c)(2) 7.3 Compliant Duration of transmission 15.323 (c)(3) 8.2.2 Compliant System acknowledgment test 15.323(c)(4) 8.2.1 Compliant Channel confirmation, Power accuracy, Segment occupancy 15.323 (c)(5) 7.3.3 & 7.3.4 Compliant Random waiting 15.323 (c)(6) 8.1.3 Not Applicable Monitoring bandwidth 15.323 (c)(7) 7.4 Compliant Page 6 of 67 Report No.: STS2403171W02 Monitoring reaction time 15.323 (c)(1 ) 7.5 Compliant Monitoring antenna 15.323 (c)(8) 4 Compliant Monitoring thresh- old relaxation 15.323 (c)(9) 4 Compliant Duplex connections 15.323 (c)(10) 8.3 Not Applicable Alternate monitoring interval 15.323 (c)(11) 8.4 Not Applicable Fair access 15.323 (c)(12) Declaration Not Applicable Frame period 15.323 (e) 6.2.2 & 6.2.3 Compliant Frequency stability 15.323 (f) 6.2.1 Compliant Radiated Out of Band Emissions 15.319 (g), 15.309 (b) & FCC Part 15 Subpart B, 15.109 and 15.209 -- Compliant Page 7 of 67 Report No.: STS2403171W02 1 INTRODUCTION 1.1 TEST FACTORY SHENZHEN STS TEST SERVICES CO., LTD Add. : 101, Building B, Zhuoke Science Park, No.190 Chongqing Road, ZhanChengShequ, Fuhai Sub-District, Bao’an District, Shenzhen, Guang Dong, China FCC test Firm Registration Number: 625569 IC test Firm Registration Number: 12108A…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jalen Zhang(Manager)
[email protected]86-13550858379Fax: 86-28-84334099

Test Firm

SHENZHEN STS TEST SERVICES CO.,LTD.Bovey Yang
[email protected]+86 755-36886288

Technical Specifications

#Rule PartsFrequency RangePower Output
115D1.92 GHz - 1.93 GHz71.78 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. The antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Highest reported SAR for Head-worn is 0.06 W/kg respectively.

Other Applications from Chengdu Accsoon Technology Co., LTD.

2AOH401MIC03

ACCSOON CoMo SE

Sep 25, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AOH408WITFR

CineView 2 SDI

Jun 26, 2024

Equipment Class

DTS - Digital Transmission System
2AOH404WIT0M

Accsoon CineView Nano

Jan 22, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Wireless Video Transmitter - FCC ID 2AOH402WITFR - Chengdu Accsoon Technology Co., LTD.
2AOH402WITFR

Wireless Video Transmitter

Aug 13, 2020

Equipment Class

DTS - Digital Transmission System