FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Anker Innovations Limited/
  3. 2AOKB-A2583

2AOKB-A2583Wireless Charger

Anker Innovations Limited
Wireless Charger - FCC ID 2AOKB-A2583 - Anker Innovations Limited
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
May 24, 2021
Application Purpose
Original Equipment
Date of Application
May 23, 2021
Equipment Note
Wireless Charger
Frequency Range
0.11500000 - 0.20500000
Company
Anker Innovations Limited
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

A2583-SafetySheet-EN-20210512 ChargingBase Charging Base FrontLEDIndicatorsStatus LeftLED Indicator RightLEDIndicator Solidwhitefor3 seconds, thenturnsoff Solidwhitefor3 seconds, thenturnsoff Connectedtopower SolidwhiteChargingyourmobilephone SolidwhiteChargingyourAirPods FlashingorangeIncompatibleACadapterconnected, indicatingthatyoushouldswitchto thesuppliedwallchargeroraUSB-C wallcharger(45Worabove)that supportsPowerDelivery FlashingwhiteMetalobjectdetected RearLEDIndicatorStatus Solidwhitefor10seconds, thenturnsoff Workingnormally FlashingorangeIncompatibleACadapterconnected, indicatingthatyoushouldswitchto thesuppliedwallchargeroraUSB-C wallcharger(45Worabove)that supportsPowerDelivery IncompatibleACadapterconnected,indicatingthatyoushouldswitchtothesupplied wallchargeroraUSB-Cwallcharger(45Worabove)thatsupportsPowerDelivery Tochargealow-powerdevicewithacurrentcapacityof80mAorless,pressand hold(ordouble-press)thebuttonontheportablechargerfor2secondstoactivate thelow-currentchargingmode. Usewiththesuppliedwallchargeronly.Donotconnecttoacomputer'sUSBport asitmayaffectthewirelesschargingfunction. Usinganultra-thickprotectivephonecaseoracasewithamagnetic/metalplateis notrecommendedasitmayaffectthewirelesschargingfunction. Donotplaceanyforeignobjectsbetweenyoursmartphoneandthewireless charger’ssurface,includingmetalpadsonacarmount,creditcards,keys,coins, NFCcardsorothermetalobjects,asitmaycauseoverheating. ImportantSafetyInstructions Pleaserefertotheelectricalandsafetyinformationbeforeinstallingoroperating theproduct. Avoiddropping. Donotdisassemble. Donotexposetoliquids. Forthesafestandfastestcharge,useoriginalorcertifiedcables. Thisproductissuitableformoderateclimatesonly. Themaximumambienttemperatureduringuseofthisproductmustnotexceed40°C. Openflamesources,suchascandles,mustnotbeplacedonthisproduct. Onlyuseadryclothorbrushtocleanthisproduct. Thesocket-outletshallbeinstalledneartheproductandshallbeeasilyaccessible. DisconnectionfromlinevoltageshouldbemadeviatheACplug. Whenusingthisproduct,basicprecautionsshouldalwaysbefollowed,including thefollowing: 1)Storetheproductinacoolanddryplace. 2)Donotstoretheproductinahotorhumidenvironment. 3)Useofapowersupplyorchargernotrecommendedorsoldbytheproduct manufacturermayresultinariskoffireorinjurytopersons. 4)Donotdisassembletheproduct.Takeittoaqualifiedservicepersonwhenserviceor repairisrequired.Incorrectreassemblymayresultinariskoffireorinjurytopersons. 5)Iftheproductisnotusedforlongperiodsoftime,youshouldchargeanddischarge onceeverythreemonths. 6)Whenchargingadevice,theproductmayfeelwarm.Thisisanormaloperating conditionandshouldnotbeacauseforconcern. 7)Donotdisposeoftheproductinheatorfire. 8) Do not clean the product with harmful chemicals or detergents. 9) Misuse, dropping, or excessive force may cause product damage. 10) When disposing of secondary cells or batteries, keep cells or batteries of different electrochemical systems separate from each other. FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC RF exposure statement: The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected. Product Name: Wireless Charger Model: A2583 The following importer is the responsible party (for FCC matters only). CompanyName:FantasiaTradingLLC Address:5350OntarioMillsPkwy,Suite100,Ontario,CA91764 Telephone:+18009887973 ICStatement ThisdevicecomplieswithRSS ‐ 216ofIndustryCanada.Operationissubjecttothe conditionthatthisdevicedoesnotcauseharmfulinterference. -English: Thisdevicecontainslicence-exempttransmitter(s)/receiver(s)thatcomplywith Innovation,ScienceandEconomicDevelopmentCanada’slicence-exemptRSS(s). Operationissubjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseinterference. (2)Thisdevicemustacceptanyinterference,includinginterferencethatmaycause undesiredoperationofthedevice. Anychangesormodificationsnotexpresslyapprovedbythepartyresponsiblefor compliancecouldvoidtheuser'sauthoritytooperatetheequipment. RFexposurestatement: TheequipmentcomplieswithICRadiationexposurelimitsetforthforuncontrolled environment.Thisequipmentshouldbeinstalledandoperatedwithminimumdistance 20cmbetweentheradiatorandyourbody. -French: Cetappareilcontientdesémetteurs/récepteursexemptésdelicenceconformesaux RSS(RSS)d'Innovation,SciencesetDéveloppementéconomiqueCanada.Le fonctionnementestsoumisauxdeuxconditionssuivantes: (1)Cetappareilnedoitpascauserd'interfé…

Text truncated - open the document above for the full version.

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Anker Innovations Limited Company: Anker Innovations Limited Address: Room 1318-19, Hollywood Plaza, 610 Nathan Road, Mongkok, Kowloon, Hongkong Product Name: Wireless Charger Model Number: A2583 FCC Identifier: 2AOKB-A2583 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: louis Qi Date: 5/10/2021 Title: Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 Anker Innovations Limited Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 5/10/2021 Subject: Request for Confidentiality FCC ID: 2AOKB-A2583 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☒ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☒ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of __180____ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: louis Qi Title:

External Photos

1 - Page 1 of 10 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] APPENDIX 1- EUT PHOTO Photo 1 (For model A2583) Photo 2 1 - Page 2 of 10 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 3 Photo 4 1 - Page 3 of 10 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 5

Internal Photos

1 - Page 4 of 10 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 6 1 - Page 5 of 10 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 7 Photo 8 1 - Page 6 of 10 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 9 Photo 10 1 - Page 7 of 10 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 11 Photo 12 Wireless charge ANT 1 - Page 8 of 10 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 13 Photo 14 1 - Page 9 of 10 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 15 Photo 16 1 - Page 10 of 10 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 17 (HOLTEK Chip) Photo 18 (CHIPSEA Chip) ----END OF REPORT----

RF Exposure Info

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] RF EXPOSURE Test Report Report No.: MTi210416004-05E2 Date of issue: May 08, 2021 Applicant: Anker Innovations Limited Product name: Wireless Charger Model(s): A2583 FCC ID: 2AOKB-A2583 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 11 - Report No.: MTi210416004-05E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Instructions 1. The report shall not be partially reproduced without the written consent of the laboratory; 2. The test results of this report are only responsible for the samples submitted; 3. This report is invalid without the seal and signature of the laboratory; 4. This report is invalid if transferred, altered or tampered with in any form without authorization; 5. Any objection to this report shall be submitted to the laboratory within 15 days from the date of receipt of the report. - Page 3 of 11 - Report No.: MTi210416004-05E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] TEST RESULT CERTIFICATION Applicant’s name .................... : Anker Innovations Limited Address .................................. : Room 1318-19, Hollywood Plaza, 610 Nathan Road, Mongkok, Kowloon, Hongkong Manufacturer's Name ............. : Anker Innovations Limited Address .................................. : Room 1318-19, Hollywood Plaza, 610 Nathan Road, Mongkok, Kowloon, Hongkong Factory 1's Name ................... : HU NAN GIANTSUN POWER ELECTRONICS CO., LTD Address .................................. : Building1, 15, 16 , 17, Taiwan Industrial Zone, Nonferrous Metals Industrial park, Chenzhou, Hunan, China Factory 2's Name ................... : GIANTSUN POWER ELECTRONICS (VIETNAM) CO., LTD. Address .................................. : Factory No. 6, Lot CN8, Thach That - Quoc Oai Industrial Park, Phung Xa Commune, Thach That District, Hanoi City, Vietnam Product description Product name ........................... : Wireless Charger Trademark ............................. : ANKER Model Name .......................... : A2583 Serial Model ............................ N/A Standards ............................... : FCC CFR 47 PART 1 , 1.1310 Test procedure ....................... : KDB 680106 D01 RF Exposure Wireless Charging Apps v03r01 Date of Test Date (s) of performance of tests ............ : Apr. 02, 2021 ~ Apr. 30, 2021 Test Result ............................................. : Pass This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Testing Engineer : (Danny Xu) Technical Manager : (Leo Su) Authorized Signatory : (Tom Xue) - Page 4 of 11 - Report No.: MTi210416004-05E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Table of Contents 1 GENERAL INFORMATION .......................................................................................................................................... 5 1.1 DESCRIPTION OF EUT ................................................................................................................................................... 5 1.2 ANCILLARY EQUIPMENT LIST ........................................................................................................................................... 5 1.3 MEASUREMENT UNCERTAINTY ........................................................................................................................................ 5 2 TESTING SITE ............................................................................................................................................................ 7 3 LIST OF TEST EQUIPMENT ......................................................................................................................................... 8 4 TEST RESULTS ........................................................................................................................................................... 9 4.4 MAXIMUM PERMISSIBLE EXPOSURE.................................................................................................................................. 9 4.4.1 Limit .................................................................................................................................................................... 9 4.4.2 Test Procedures ................................................................................................................................................... 9 4.4.3 Test Setup.......................................................................................................................................................... 10 4.4.4 Test Result ......................................................................................................................................................... 10 4.4.5 MPE Setup photo .................................................................................................................错误!未定义书签。 - Page 5 of 11 - Report No.: MTi210416004-05E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 …

Text truncated - open the document above for the full version.

Test Report

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Test Report Report No.: MTi210416004-05E1 Date of issue: May 08, 2021 Applicant: Anker Innovations Limited Product name: Wireless Charger Model(s): A2583 FCC ID: 2AOKB-A2583 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 27 - Report No.: MTi210416004-05E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Instructions 1. The report shall not be partially reproduced without the written consent of the laboratory; 2. The test results of this report are only responsible for the samples submitted; 3. This report is invalid without the seal and signature of the laboratory; 4. This report is invalid if transferred, altered or tampered with in any form without authorization; 5. Any objection to this report shall be submitted to the laboratory within 15 days from the date of receipt of the report. - Page 3 of 27 - Report No.: MTi210416004-05E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Table of Contents 1 GENERAL INFORMATION ................................................................................................................................... 5 1.1 FEATURE OF EQUIPMENT UNDER TEST (EUT) ................................................................................................................... 5 1.2 TEST MODE .............................................................................................................................................................. 5 1.3 EUT TEST SETUP........................................................................................................................................................ 5 1.4 ANCILLARY EQUIPMENT .............................................................................................................................................. 5 2 SUMMARY OF TEST RESULT ............................................................................................................................... 6 2.1 OPERATION CHANNEL LIST ........................................................................................................................................... 6 2.2 TEST CHANNEL .......................................................................................................................................................... 6 3 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 7 3.1 TEST LABORATORY ..................................................................................................................................................... 7 3.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 7 3.3 MEASUREMENT UNCERTAINTY ...................................................................................................................................... 7 4 LIST OF TEST EQUIPMENT .................................................................................................................................. 8 5 TEST RESULTS ..................................................................................................................................................... 9 5.1 ANTENNA REQUIREMENT ............................................................................................................................................ 9 5.1.1 Standard requirement ................................................................................................................................. 9 5.1.2 EUT Antenna ............................................................................................................................................... 9 5.2 CONDUCTED EMISSION ............................................................................................................................................. 10 5.2.1 Limits ......................................................................................................................................................... 10 5.2.2 Test Procedures ......................................................................................................................................... 10 5.2.3 Test Setup .................................................................................................................................................. 10 5.2.4 Test Result ................................................................................................................................................. 10 5.3 RADIATED EMISSION ................................................................................................................................................. 19 5.3.1 Limits ......................................................................................................................................................... 19 5.3.2 Test Procedures ......................................................................................................................................... 20 5.3.3 Test Setup .................................................................................................................................................. 21 5.3.4 Test Result .................................................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Model: A2583 Radiated emission Conducted emission MPE Setup photo

Contact Information

Applicant

Louis Qi
[email protected]+86-755-86544807Fax: N/A

Technical Contact

Shenzhen Microtest Co., LtdLeo Su
[email protected]86-755 88850135

Shenzhen · China

Test Firm

Shenzhen Microtest Co., Ltd.Selby Liao
[email protected]0755-88850135-1193

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.115 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Anker Innovations Limited

2AOKB-AS510

Anker SOLIX S5000 Portable Power Station

Sep 15, 2026

Equipment Class

DTS - Digital Transmission System
2AOKB-A1664B

Anker MagGo Power Bank (10K,Slim)

Aug 26, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2AOKB-A1665A

Anker Nano Power Bank (5K, MagGo, Slim)

Aug 26, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2AOKB-D1105R

ANKER AeroClip 2

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
2AOKB-D1105L

ANKER AeroClip 2

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System