Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
For tutorial videos, FAQs, manuals, and more information, please visit: Or scan the QR code below: https://support.anker.com SAFETY SHEET USER GUIDE UŽIVATELSKÁ PŘÍRUČKA | BRUGERVEJLEDNING | BENUTZERHANDBUCH ΟΔΗΓΟΣ ΧΡΗΣΤΗ | GUÍA DEL USUARIO | KÄYTTÖOPAS GUIDE DE L'UTILISATEUR | FELHASZNÁLÓI ÚTMUTATÓ | GUIDA PER L'UTENTE GEBRUIKERSGIDS | BRUKERHÅNDBOK | PRZEWODNIK UŻYTKOWNIKA GUIA DO USUÁRIO | РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ | GHIDUL UTILIZATORULUI POUŽÍVATEĽSKÁ PRÍRUČKA | NAVODILA ZA UPORABNIKA ANVÄNDARHANDLEDNING | KULLANICI KILAVUZU | 取扱説明書はこちら 사용자 가이드 | 用户指南 | 使用手冊 | دلیل المستخدم | מדריך למשתמש Anker MagGo Wireless Charging Station (3-in-1, Foldable Pad) Product Number: A25M8 51005004973 V1 EN 0201 EN EN Specifications Input12V 3A / 15V 2.66A / 9V 3A Output Phone: 15W Max Apple Watch: 5W Max TWS: 5W Max This wireless charger is not compatible with non-MagSafe phone cases, such as Otterbox Defender cases. Connect the wireless charger to a Quick Charge 2.0/3.0 or Power Delivery wall adapter. Do not connect to a 5V/1A wall charger or a USB port on a computer as it may affect the wireless charging function. Do not place any foreign objects between your device and the wireless charger’s surface, including metal pads on a car mount, magnetic cards, door keys, coins, NFC cards or other metal objects, as they could potentially demagnetize the wireless charger, affect the charging speed, or cause overheating. Wireless charging products make charging more convenient than wired chargers, but confined by current wireless technology, their charging speed is slower than that of wired chargers. High temperatures will reduce charging speed and restrict power. It is recommended that you charge your device in environments with temperatures below 40°C / 104°F. Important Safety Instructions Please refer to the electrical and safety information on the bottom before installing or operating the product. The maximum ambient temperature during use of this product must not exceed 40°C. FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC RF Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator & your body. The following importer is the responsible party (for FCC matters only). Company Name: Fantasia Trading LLC Address: 5350 Ontario Mills Pkwy, Suite 100, Ontario, CA 91764 Telephone: +1 800 988 7973 IC Statement This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: CS 0403 EN 1. L'appareil ne doit pas produire de brouillage; 2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. RF exposure statement: The equipment complies with IC Radiation exposure limits set forth for uncontrolled environments. This equipment should be installed and operated with a minimum distance of 10cm between the radiator and your body. Déclaration d'exposition RF: L'équipement est conforme à la limite d'exposition aux radiations de la IC établie pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 10 cm entre le radiateur et votre corps. EU Declaration of Conformity Hereby, Anker Innovations Limited declares that this product is in compliance with Directives 2014/53/EU & 2011/65/EU. The full text of the EU declaration of conformity is available at the following internet address: https://support.anker.com/s/articleRecommend?otherType=Anker_ EN_Extemal_Manual_and_Download&secondType=doc To comply with RF exposure requirements, a minimum separation distance of 20cm must be maintained between the user’s body and the product. TX/RX Frequency Range and Max R…
Text truncated - open the document above for the full version.
1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: Fantasia Trading LLC FRN: 0033423005 Contact Name: Louis Qi Address: 5350 Ontario Mills Pkwy, STE 100, Ontario, CA 91764 Telephone No: +1 (800)988 7973 Email: [email protected] Applicant: Company name: Anker Innovations Limited Product Description: Anker MagGo Wireless Charging Station (3-in-1, Foldable Pad) Grantee code: 2AOKB FCC ID: 2AOKB-A25M8 Contact Name: Louis Qi Address: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong Telephone No: +86-13652441319 Email: [email protected] [Anker Innovations Limited] certifies that, as of the date of this filing of the application with the TCB, [Fantasia Trading LLC] is our designated US agent for service of process for the above referenced FCC ID. [Anker Innovations Limited] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [Fantasia Trading LLC] accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 08/09/2024 Applicant’s Name: Louis Qi US Agent for Service of Process’s Name: Louis Qi Title: Manager Title: Compliance Manager 1/1 Signature Signature
C5266091_X24_Ed.2 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Anker Innovations Limited FRN: 0027073105 Grantee code: 2AOKB FCC ID: 2AOKB-A25M8 Contact Name: Louis Qi Address: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong Telephone No: +86-13652441319 Fax No: / Email: [email protected] i. [Anker Innovations Limited] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Anker Innovations Limited] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. Anker Innovations Limited certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Date: 08.09.2024 Applicant’s Name: Louis Qi Title: Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist
C5266091_X8_Ed.1 1/1 Letter of Authorization Company: Anker Innovations Limited Address: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong Product Name: Anker MagGo Wireless Charging Station (3-in-1, Foldable Pad) Model Number: A25M8 FCC Identifier: 2AOKB-A25M8 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Louis Qi Date: 8/20/2024 Title: Manager Signature of applicant:
C5266091_X10_Ed.2 1/1 Anker Innovations Limited Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 8/20/2024 Subject: Request for Confidentiality FCC ID: 2AOKB-A25M8 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Louis Qi Title: Manager
Page 1 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Photographs of the EUT Model: A25M8 External Page 2 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 3 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 4 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected]
双向居中对齐 双向居中对齐 20mm
Page 1 of 6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Photographs of the EUT Model: A25M8 Coil 3 Coil 2 Coil 1 Page 2 of 6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 3 of 6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 4 of 6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 5 of 6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 6 of 6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected]
Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Test Report Report No.: MTi240617015-01E2 Date of issue: 2024-07-22 Applicant: Anker Innovations Limited Product: Anker MagGo Wireless Charging Station (3-in-1, Foldable Pad) Model(s): A25M8 FCC ID: 2AOKB-A25M8 Shenzhen Microtest Co., Ltd. http:// Web: www.mtitest.cn Page 2 of 15 Report No.: MTi240617015-01E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Instructions 1. This test report shall not be partially reproduced without the written consent of the laboratory. 2. The test results in this test report are only responsible for the samples submitted 3. This test report is invalid without the seal and signature of the laboratory. 4. This test report is invalid if transferred, altered, or tampered with in any form without authorization. 5. Any objection to this test report shall be submitted to the laboratory within 15 days from the date of receipt of the report. Page 3 of 15 Report No.: MTi240617015-01E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Contents 1 General Description ........................................................................................................................ 5 1.1 Description of the EUT ....................................................................................................................................... 5 1.2 Description of test modes ................................................................................................................................... 5 1.3 Description of support units ................................................................................................................................ 7 2 Measurement uncertainty ............................................................................................................... 7 3 Test facilities and accreditations .................................................................................................... 8 3.1 Test laboratory .................................................................................................................................................... 8 4 List of test equipment ..................................................................................................................... 9 5 Test result ...................................................................................................................................... 10 5.2 Test setup ......................................................................................................................................................... 11 5.3 Test Procedures ................................................................................................................................................ 11 5.4 Information of test equipment ........................................................................................................................... 12 5.5 Test results ....................................................................................................................................................... 13 Photographs of the Test Setup ............................................................................................................ 15 Photographs of the EUT....................................................................................................................... 15 Page 4 of 15 Report No.: MTi240617015-01E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Test Result Certification Applicant: Anker Innovations Limited Address: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kon g Manufacturer: Anker Innovations Limited Address: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kon g Product description Product name: Anker MagGo Wireless Charging Station (3-in-1, Foldable Pad) Trademark: ANKER Model name: A25M8 Series Model: N/A Standards: 47 CFR PART 1, § 1.1310 Test method: KDB 680106 D01 Wireless Power Transfer v04 Date of Test Date of test: 2024-07-01 to 2024-07-19 Test result: Pass Test Engineer : (Yanice.Xie) Reviewed By : (David Lee) Approved By : (Leon Chen) Page 5 of 15 Report No.: MTi240617015-01E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] 1 General Description 1.1 Description of the EUT Product name: Anker MagGo Wireless Charging Station (3-in-1, Foldable Pad) Model name: A25M8 Series Model: N/A Model difference: N/A Electrical rating: Input:9⎓3A,12V⎓3A,15V⎓2.66A Output:15W Max/5W Max/5W Max (Phone:15W Max/TWS:5W Max/Watch:5W Max) Accessories: 1. Adapter(model:ASGaN83w-P40W20: Input:100-240V~50/60Hz 1.0A Output:5.0V⎓3.0A 15.0W / 9.0V⎓3.0A 27.0W / 12.0V⎓3.0A 36.0W / 15.0V⎓2.66A 39.9W / 20V⎓2A 40.0W Manufacturer: Anker Innovations Limited 2. Cable:Type-C to type-C 1.5m Hardware version: BPP: SN-A25M8-A-C4 MPP: SN-WB006-B-C4 V2.0.2 Software version: SN A25M8_ CPS8601_MTP_1E_04_/CPS8602_MTP_1E_03_ Test sample(s) number: MTi240617015-01S1001 RF specific…
Text truncated - open the document above for the full version.
The test report is only used for customer scientific research, teaching, internal quality control and other purposes, and is for internal reference only. Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] 1 Test Report Report No.: MTi240617015-01E1 Date of issue: 2024-07-22 Applicant: Anker Innovations Limited Product name: Anker MagGo Wireless Charging Station (3-in-1, Foldable Pad) Model(s): A25M8 FCC ID: 2AOKB-A25M8 Shenzhen Microtest Co., Ltd. http://www.mtitest.cn Page 2 of 31 Report No.: MTi240617015-01E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Instructions 1. This test report shall not be partially reproduced without the written consent of the laboratory. 2. The test results in this test report are only responsible for the samples submitted 3. This test report is invalid without the seal and signature of the laboratory. 4. This test report is invalid if transferred, altered, or tampered with in any form without authorization. 5. Any objection to this test report shall be submitted to the laboratory within 15 days from the date of receipt of the report. Page 3 of 31 Report No.: MTi240617015-01E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Table of contents 1 General Description ......................................................................................................................... 5 1.1 Description of the EUT ............................................................................................................................... 5 1.2 Description of test modes .......................................................................................................................... 5 1.3 Environmental Conditions .......................................................................................................................... 7 1.4 Description of support units ....................................................................................................................... 7 1.5 Measurement uncertainty .......................................................................................................................... 7 2 Summary of Test Result .................................................................................................................. 8 3 Test Facilities and accreditations ................................................................................................... 9 3.1 Test laboratory ........................................................................................................................................... 9 4 List of test equipment .................................................................................................................... 10 5 Evaluation Results (Evaluation) .................................................................................................... 11 5.1 Antenna requirement ............................................................................................................................... 11 6 Radio Spectrum Matter Test Results (RF) .................................................................................... 12 6.1 Conducted Emission at AC power line .................................................................................................... 12 6.2 20dB Occupied Bandwidth ...................................................................................................................... 15 6.3 Emissions in frequency bands (below 30MHz)........................................................................................ 22 6.4 Emissions in frequency bands (30MHz - 1GHz)...................................................................................... 27 Photographs of the test setup ............................................................................................................. 30 Photographs of the EUT....................................................................................................................... 31 Page 4 of 31 Report No.: MTi240617015-01E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Test Result Certification Applicant: Anker Innovations Limited Address: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong K ong Manufacturer: Anker Innovations Limited Address: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong K ong Product description Product name: Anker MagGo Wireless Charging Station (3-in-1, Foldable Pad) Trademark: ANKER Model name: A25M8 Series Model(s): N/A Standards: 47 CFR Part 15C Test Method: ANSI C63.10-2013 Date of Test Date of test: 2024-07-01 to 2024-07-19 Test result: Pass Test Engineer : (Yanice.Xie) Reviewed By : (David Lee) Approved By : (Leon Chen) Page 5 of 31 Report No.: MTi240617015-01E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] 2 General Description 2.1 Description of the EUT Product name: Anker MagGo Wireless Charging Station (3-in-1, Foldable Pad) Model name: A25M8 Series…
Text truncated - open the document above for the full version.
产品型号 版本 REV: 客户 T 客户料号 一、尺寸DIMENSION(MM) E F G H 线圈 隔磁片 磁铁 PET背胶 A 7.0±0.3 B 20.6± 0.5 C 9±0.5 D 19±0.5 E 0.7±0.1 F 1.5±0.5 G 3.8±0.5 H 0.1± 0.05 二、绕线参数Winding Specification: 线 材 Wire 圈 数 Turns 绕线方向 Winding Direction 尺寸 0.4*0.7 MM 9 TS 反绕 四、电气特性 ELECTRICAL CHARACTERISTICS: 温度 TEMPERATURE:25±10°C,湿度RELATIVE HUMIDITY :65±20% 项目 TIEM 标准 SPECIFICATION 测试条件 TEST FREQUENCY 测试仪器 TEST EQUIPMENTS IND 6.4UH±10% 100 KHZ/1.0V LCZ METER 1062B DCR 50mΩ Max LCZ METER 1062B 器件规格书 C962 Apple Inc.
Page 1 of 2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Photographs of the test setup Model: A25M8 Conducted Emission at AC power line Radiated Emissions (below 30MHz) Page 2 of 2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Radiated Emissions (30MHz - 1GHz) MPE
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 3 | 15C | 0.3265 MHz - 0.3265 MHz | - |
ANKER AeroClip 2
Equipment Class
DTS - Digital Transmission SystemANKER AeroClip 2
Equipment Class
DTS - Digital Transmission System
Anker MagGo Power Bank 2 Pro
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzAnker soundcore Liberty Buds 2
Equipment Class
JBP - Part 15 Class B Computing Device PeripheralAnker soundcore Liberty Buds 2
Equipment Class
DTS - Digital Transmission System