FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Anker Innovations Limited/
  3. 2AOKB-A31A3

2AOKB-A31A3Wireless speaker

Anker Innovations Limited

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 29, 2024
Application Purpose
Original Equipment
Date of Application
Aug 29, 2024
Equipment Note
Wireless speaker
Frequency Range
2402.00000000 - 2480.00000000
Company
Anker Innovations Limited
Country
Hong Kong

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Anker Innovations Limited Section 2.911(d)(7) USA Agent for Service of Process Company name: Anker Innovations Limited Address: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong FRN: 0027073105 FCC ID: 2AOKB-A31A3 2.911(d)(7) USA Designated Agent for Service of Process We, [Anker Innovations Limited] (“the applicant”) designate [Fantasia Trading LLC] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent:We Acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation:We Acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Company name: Fantasia Trading LLC Address: 5350 Ontario Mills Pkwy, STE 100, Ontario, CA 91764, United States FRN: 0033423005 Contact Name: Louis Qi Telephone No: +1 (800)988 7973 Email: [email protected] Applicant Company name: Anker Innovations Limited Address: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong Grantee Code: 2AOKB Contact Name: Louis.qi Telephone No: +86-755-86544807 Email:[email protected] Signature: Signature: Title:Compliance Manager Date:Aug. 21, 2024 Title: Compliance Manager Date: Aug. 21, 2024 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process. Reference; Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-th e-communications-supply-chain-through-the

Attestation Statements

AnkerInnovationsLimited Unit56,8thFloor,Tower2,AdmiraltyCentre,18HarcourtRoad,HongKong FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:Aug.21,2024 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2AOKB-A31A3 FRN:0027073105 [AnkerInnovationsLimited](“theapplicant”)certifiesthattheequipmentforwhichauthorizationis soughtisnot“covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules. Sincerely, (Applicantsignature) (LouisQi)

Attestation Statements

AnkerInnovationsLimited Unit56,8thFloor,Tower2,AdmiraltyCentre,18HarcourtRoad,HongKong FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:Aug.21,2024 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2AOKB-A31A3 FRN:0027073105 [AnkerInnovationsLimited](“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication, theapplicantisnotidentifiedontheCoveredListasanentityproducing“covered”equipment. Sincerely, (Applicantsignature) (LouisQi)

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Company: Anker Innovations Limited Address: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong Product Name: Wireless speaker Model Number: A31A3 FCC Identifier: 2AOKB-A31A3 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Louis Qi Date: Aug. 21, 2024 Title: General Manager Signature of applicant:

Cover Letter(s)

AnkerInnovationsLimited Unit56,8thFloor,Tower2,AdmiraltyCentre,18HarcourtRoad,HongKong Long/Short-termConfidentialityRequest FederalCommunicationsCommissionDate:Aug.21,2024 44512 th StreetSW Washington,DC20554 FCCID:2AOKB-A31A3 ToWhomitmayconcerns, Pursuanttosections0.457(d)and0.459ofCFR47andtoavoidprematurereleaseof sensitiveinformationpriortomarketingorreleaseoftheproducttothepublic,wehereby requestslong-termconfidentialtreatmentofinformationaccompanyingthisapplicationas outlinedbelow: SchematicsPartsList BlockDiagramTune-UpInfo OperationalDescription Inadditionweherebyrequestthefollowingexhibitscontainedinthisapplicationtobe temporarily(short-termconfidentilality)withheldfromthepublicdisclosure foraninitialperiodof180daysuntil:notapplicable ExternalPhotosTestSetupPhotos InternalPhotosUsersManual Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarily releasedtothepublic.Thepublicdisclosureofthesemattersmightbeharmfultothe applicantandprovideunjustifiedbenefitstoitscompetitors. Theapplicantunderstandsthatpursuanttorule0.457(d),disclosureofthisapplicationand allaccompanyingdocumentationwillnotbemadebeforethedateoftheGRANTforthis application. Ifyouhaveanyquestions,pleasefeelfreetocontactme. Yourssincerely, Signatory Contactperson:LouisQi Title:GeneralManager

ID Label/Location Info

44.89 95.3 44.89 95.3 Label Location

RF Exposure Info

Page 1 of 10 RF Exposure Report Report No.: AGC01110240642FH01 FCC ID : 2AOKB-A31A3 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Wireless speaker BRAND NAME : soundcore MODEL NAME : A31A3 APPLICANT : Anker Innovations Limited DATE OF ISSUE : Aug. 21, 2024 STANDARD(S) : FCC Part 2 Subpart J §2.1091 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC01110240642FH01 Page 2 of 10 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Aug. 21, 2024 Valid Initial Release Report No.: AGC01110240642FH01 Page 3 of 10 Table of Contents 1. General Information ........................................................................................................................................ 4 2. Product Information ........................................................................................................................................ 5 2.1 Product Technical Description ................................................................................................................... 5 3. Test Environment ............................................................................................................................................ 6 3.1 Address Of The Test Laboratory ............................................................................................................... 6 3.2 Test Facility ................................................................................................................................................ 6 3.3 Environmental Conditions ......................................................................................................................... 7 4. Portable Device Evaluation Method and Limit ............................................................................................. 8 5. Mobile Device Evaluation Method and Limit ................................................................................................ 9 6. Measurement Results ................................................................................................................................... 10 7. Measurement Evaluation .............................................................................................................................. 10 Report No.: AGC01110240642FH01 Page 4 of 10 1. General Information Applicant Anker Innovations Limited Address Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong Manufacturer Anker Innovations Limited Address Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong Factory N/A Address N/A Product Designation Wireless speaker Brand Name soundcore Test Model A31A3 Series Model(s) N/A Difference Description N/A Date of receipt of test item Jul. 12, 2024 Date of Test Jul. 12, 2024 to Aug. 13, 2024 Deviation from Standard No any deviation from the test method Condition of Test Sample Normal Test Result Pass Test Report Form No AGCER-FCC-RF Exposure-V1 Note: The test results of this report relate only to the tested sample identified in this report. Prepared By Cici Li (Project Engineer) Aug. 21, 2024 Reviewed By Calvin Liu (Reviewer) Aug. 21, 2024 Approved By Max Zhang Authorized Officer Aug. 21, 2024 Report No.: AGC01110240642FH01 Page 5 of 10 2. Product Information 2.1 Product Technical Description Frequency Band (Operating) Bluetooth: 2.402GHz ~ 2.480GHz Hardware Version V1.1 Software Version V3.4.2 Modulation Type ANT1 (Chip: ATS2835P2): BR GFSK_1Mbps ; EDR π /4-DQPSK_2Mbps 8DPSK_3Mbps BLE GFSK 1Mbps GFSK 2Mbps ANT2 (Chip: AC7066M): BLE GFSK 1Mbps GFSK 2Mbps ANT3 (Chip: AC7066M): BLE GFSK 1Mbps GFSK 2Mbps Device Category Portable (<20cm separation) Mobile (>20cm separation) Others: Antenna Diversity Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Antenna Designation FPC Antenna Antenna Gain ANT1 (Chip: ATS2835P2): 4.80dBi ANT2 (Chip: AC7066M): 4.31dBi ANT3 (Chip: AC7066M): 4.40dBi Minimum Assessment Distance 20cm Evaluation Applied MPE Evaluation SAR Evaluation Report No.: AGC01110240642FH01 Page 6 of 10 3. Test Environment 3.1 Address Of The Test Laboratory Laboratory: Attestation of Global Compliance (Shenzhen) Co., Ltd. Address: 1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 3.2 Test Facility The test facility is recognized, certified, or accredited by the following organizations: CNAS-Lab Code: L5488 Attestation of Global Compliance (Shenzhen) Co., Ltd. has been assessed and proved to follow CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories.) A2LA-Lab Cert. No.: 5054.02 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been accredited by A2LA for technical competence in the field of electrical testing, and proved to follow ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing. FCC-Registration No.: 975832 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from the FCC is maintained in our files with Registration 975832. IC-Registration No.: 24842(CAB identifier: CN0063) Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the Certification and Engineering Bureau of Industry Canada. The acceptance letter from the IC is maintained in our files with Registration 24842. Report No.: AGC01110240642FH01 Page 7 of 10 3.3 Environmental Conditions Normal Conditions Temperature range (°C) 15 - 35 Relative humidity range 20 % - 75 % Pressure range (kPa) 86 - 10…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 69 FCC Test Report Report No.: AGC01110240642FR02 FCC ID : 2AOKB-A31A3 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Wireless speaker BRAND NAME : soundcore MODEL NAME : A31A3 APPLICANT : Anker Innovations Limited DATE OF ISSUE : Aug. 21, 2024 STANDARD(S) : FCC Part 15 Subpart C §15.247 REPORT VERSION : V1.0 Attestation Of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC01110240642FR02 Page 2 of 69 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Aug. 21, 2024 Valid Initial Release Report No.: AGC01110240642FR02 Page 3 of 69 Table of Contents 1. General Information ........................................................................................................................................ 5 2. Product Information ........................................................................................................................................ 6 2.1 Product Technical Description ..................................................................................................................... 6 2.2 Test Frequency List ..................................................................................................................................... 6 2.3 Related Submittal(S) / Grant (S) ................................................................................................................. 7 2.4 Test Methodology......................................................................................................................................... 7 2.5 Special Accessories ..................................................................................................................................... 7 2.6 Equipment Modifications ............................................................................................................................. 7 2.7 Antenna Requirement .................................................................................................................................. 7 3. Test Environment ............................................................................................................................................ 8 3.1 Address of the Test Laboratory .................................................................................................................... 8 3.2 Test Facility .................................................................................................................................................. 8 3.3 Environmental Conditions ........................................................................................................................... 9 3.4 Measurement Uncertainty ........................................................................................................................... 9 3.5 List of Equipment Use ............................................................................................................................... 10 4. System Test Configuration ........................................................................................................................... 12 4.1 EUT Configuration ..................................................................................................................................... 12 4.2 EUT Exercise ............................................................................................................................................. 12 4.3 Configuration of Tested System ................................................................................................................ 12 4.4 Equipment Used In Tested System ........................................................................................................... 12 4.5 Summary of Test Results ........................................................................................................................... 13 5. Description of Test Modes ........................................................................................................................... 14 6. Duty Cycle Measurement ............................................................................................................................. 15 7. RF Output Power Measurement .................................................................................................................. 16 7.1 Provisions Applicable ................................................................................................................................. 16 7.2 Measurement Procedure ........................................................................................................................... 16 7.3 Measurement Setup (Block Diagram of Configuration) ............................................................................ 16 7.4 Measurement Result ................................................................................................................................. 16 8. 6dB Bandwidth Measurement ...................................................................................................................... 20 8.1 Provisions Applicable ................................................................................................................................. 20 8.2 Measurement Procedure ........................................................................................................................... 20 8.3 Measurement Setup (Block Diagram of Configuration) ............................................................................ 20 8.4 Measurement Results ................................................................................................................................ 21 9. Power Spectral Density Measurement ........................................................................................................ 28 9.1 Provisions Applicable ........................................................................................…

Text truncated - open the document above for the full version.

Test Report

Report No.: AGC01110240642FR02 Page 64 of 69 Band Edge Emission Test Results for Restricted Bands EUT Name Wireless speaker Model Name A31A3 Temperature 25.7°C Relative Humidity 50.0% Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 6 Antenna Polarity Vertical Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Note: The factor had been edited in the “Input Correction” of the Spectrum Analyzer. Report No.: AGC01110240642FR02 Page 65 of 69 12. AC Power Line Conducted Emission Test 12.1 Measurement Limit Frequency Maximum RF Line Voltage Q.P. (dBμV) Average (dBμV) 150kHz~500kHz 66-56 56-46 500kHz~5MHz 56 46 5MHz~30MHz 60 50 Note: 1. The lower limit shall apply at the transition frequency. 2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz 12.2 Measurement Setup (Block Diagram of Configuration) Report No.: AGC01110240642FR02 Page 66 of 69 12.3 Preliminary Procedure of Line Conducted Emission Test 1. The equipment was set up as per the test configuration to simulate typical actual usage per the user’s manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is placed on the ground plane as per ANSI C63.10 (see Test Facility for the dimensions of the ground plane used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the ground plane. 2. Support equipment, if needed, was placed as per ANSI C63.10. 3. All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10. 4. All support equipment received AC120V/60Hz power from a LISN, if any. 5. The EUT received DC 5V power from adapter which received AC120V/60Hz power from a LISN. 6. The test program was started. Emissions were measured on each current carrying line of the EUT using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1 connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1 connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver. 7. Analyzer / Receiver scanned from 150 kHz to 30MHz for emissions in each of the test modes. 8. During the above scans, the emissions were maximized by cable manipulation. 9. The test mode(s) were scanned during the preliminary test. Then, the EUT configuration and cable configuration of the above highest emission level were recorded for reference of final testing. 12.4 Final Procedure of Line Conducted Emission Test 1. EUT and support equipment was set up on the test bench as per step 2 of the preliminary test. 2. A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions. Emission frequency and amplitude were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit. If EUT emission level was less – 2dB to the A.V. limit in Peak mode, then the emission signal was re-checked using Q.P and Average detector. 3. The test data of the worst case condition(s) was reported on the Summary Data page. 12.5 Measurement Results Report No.: AGC01110240642FR02 Page 67 of 69 AC Power Line Conducted Emission Test Test Mode Mode 1 LISN Line Hot Side RESULT: PASS Report No.: AGC01110240642FR02 Page 68 of 69 AC Power Line Conducted Emission Test Test Mode Mode 1 LISN Line Neutral Side RESULT: PASS Report No.: AGC01110240642FR02 Page 69 of 69 Appendix I: Photographs of Test Setup Refer to the Report No.: AGC01110240642AP01 Appendix II: Photographs of Test EUT Refer to the Report No.: AGC01110240642AP02 -----End of Report----- Conditions of Issuance of Test Reports 1. All samples and goods are accepted by the Attestation of Global Compliance (Shenzhen) Co., Ltd (the “Company”) solely for testing and reporting in accordance with the following terms and conditions. The company provides its services on the basis that such terms and conditions constitute express agreement between the company and any person, firm or company requesting its services (the “Clients”). 2. Any report issued by Company as a result of this application for testing services (the “Report”) shall be issued in confidence to the Clients and the Report will be strictly treated as such by the Company. It may not be reproduced either in its entirety or in part and it may not be used for advertising or other unauthorized purposes without the written consent of the Company. The Clients to whom the Report is issued may, however, show or send it, or a certified copy thereof prepared by the Company to its customer, supplier or other persons directly concerned. The Company will not, without the consent of the Clients, enter into any discussion or correspondence with any third party concerning the contents of the Report, unless required by the relevant governmental authorities, laws or court orders. 3.The Company shall not be called or be liable to be called to give evidence or testimony on the Report in a court of law without its prior written consent, unless required by the relevant governmental authorities, laws or court orders. 4. In the event of the improper use of the report as determined by the Company, the Company reserves the right to withdraw it, and to adopt any other additional remedies which may be appropriate. 5. Samples submitted for testing are accepted on the understanding that the Report issued cannot form the basis of, or be the instrument for, any legal action against the Company. 6. The Company will not be liable for or accept responsibility for any loss or damage however arising from the use of information contained in any of its Reports or in any communication whatsoever about its said tests or investigations. 7.Clients wishing to use the Report in court proceedings or arbitration shall in…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 69 FCC Test Report Report No.: AGC01110240642FR03 FCC ID : 2AOKB-A31A3 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Wireless speaker BRAND NAME : soundcore MODEL NAME : A31A3 APPLICANT : Anker Innovations Limited DATE OF ISSUE : Aug. 21, 2024 STANDARD(S) : FCC Part 15 Subpart C §15.247 REPORT VERSION : V1.0 Attestation Of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC01110240642FR03 Page 2 of 69 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Aug. 21, 2024 Valid Initial Release Report No.: AGC01110240642FR03 Page 3 of 69 Table of Contents 1. General Information ........................................................................................................................................ 5 2. Product Information ........................................................................................................................................ 6 2.1 Product Technical Description ..................................................................................................................... 6 2.2 Test Frequency List ..................................................................................................................................... 6 2.3 Related Submittal(S) / Grant (S) ................................................................................................................. 7 2.4 Test Methodology......................................................................................................................................... 7 2.5 Special Accessories ..................................................................................................................................... 7 2.6 Equipment Modifications ............................................................................................................................. 7 2.7 Antenna Requirement .................................................................................................................................. 7 3. Test Environment ............................................................................................................................................ 8 3.1 Address of the Test Laboratory .................................................................................................................... 8 3.2 Test Facility .................................................................................................................................................. 8 3.3 Environmental Conditions ........................................................................................................................... 9 3.4 Measurement Uncertainty ........................................................................................................................... 9 3.5 List of Equipment Use ............................................................................................................................... 10 4. System Test Configuration ........................................................................................................................... 12 4.1 EUT Configuration ..................................................................................................................................... 12 4.2 EUT Exercise ............................................................................................................................................. 12 4.3 Configuration of Tested System ................................................................................................................ 12 4.4 Equipment Used In Tested System ........................................................................................................... 12 4.5 Summary of Test Results ........................................................................................................................... 13 5. Description of Test Modes ........................................................................................................................... 14 6. Duty Cycle Measurement ............................................................................................................................. 15 7. RF Output Power Measurement .................................................................................................................. 16 7.1 Provisions Applicable ................................................................................................................................. 16 7.2 Measurement Procedure ........................................................................................................................... 16 7.3 Measurement Setup (Block Diagram of Configuration) ............................................................................ 16 7.4 Measurement Result ................................................................................................................................. 16 8. 6dB Bandwidth Measurement ...................................................................................................................... 20 8.1 Provisions Applicable ................................................................................................................................. 20 8.2 Measurement Procedure ........................................................................................................................... 20 8.3 Measurement Setup (Block Diagram of Configuration) ............................................................................ 20 8.4 Measurement Results ................................................................................................................................ 21 9. Power Spectral Density Measurement ........................................................................................................ 28 9.1 Provisions Applicable ........................................................................................…

Text truncated - open the document above for the full version.

Test Report

Report No.: AGC01110240642FR03 Page 64 of 69 Band Edge Emission Test Results for Restricted Bands EUT Name Wireless speaker Mode…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Louis Qi
[email protected]+86-755-86544807Fax: N/A

Technical Contact

Attestation of Global Compliance (Shenzhen) Co., LDoris Li
[email protected]+86-755-25234088

Shenzhen, Guangdong · China

Non-Technical Contact

Attestation of Global Compliance (Shenzhen) Co., LDoris Li
[email protected]+86-755-25234088

Test Firm

Attestation of Global Compliance (Shenzhen) Co., LDoris Li
[email protected]+86-755-25234088

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.70 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Anker Innovations Limited

2AOKB-A1664B

Anker MagGo Power Bank (10K,Slim)

Aug 26, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2AOKB-A1665A

Anker Nano Power Bank (5K, MagGo, Slim)

Aug 26, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2AOKB-D1105R

ANKER AeroClip 2

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
2AOKB-D1105L

ANKER AeroClip 2

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
Anker MagGo Power Bank 2 Pro - FCC ID 2AOKB-A110R - Anker Innovations Limited
2AOKB-A110R

Anker MagGo Power Bank 2 Pro

Aug 19, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz