FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Anker Innovations Limited/
  3. 2AOKB-D2421X

2AOKB-D2421XNebula Capsule II

Anker Innovations Limited
Nebula Capsule II - FCC ID 2AOKB-D2421X - Anker Innovations Limited
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Aug 14, 2022
Application Purpose
Original Equipment
Date of Application
Aug 11, 2022
Equipment Note
Nebula Capsule II
Frequency Range
5745.00000000 - 5825.00000000
Company
Anker Innovations Limited
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Anker Innovations Limited Date:2022/07/04 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 Re: Request of Confidentiality forFCC ID: 2AOKB-D2421X To Whom it may concern: Pursuant to sections 0.457 and 0.459 of Commission’s Rules(CFR 47), and Section 552(b)(4) of the Freedom of Information Act, Anker Innovations Limited hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA04-1705. This provision will giveAnker Innovations Limited temporary confidentiality of commercially sensitive information prior to product release. The requested Permanent and Short-Term Confidential exhibits are listed as follows: The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. Signatory : PERMANENTANDSHORT-TERMCONFIDENTIALLIST ExhibitDescription PERMANENT 1BlockDiagram 2OperationalDescription 3Schematics 4BOM 5Tuneupprocedure SHORT-TERM 6ExternalPhotos 7InternalPhotos 8Test-SetupPhotos 9User Manual Contact name: Louis Qi Tel: +86-13652441319 Email: [email protected] Company name : Anker Innovations Limited

Cover Letter(s)

Anker Innovations Limited Date: 2022/7/4 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 To Whom It May Concern: The Anker Innovations Limited the undersigned, hereby authorizesMrs. Wendy Zhan from Shenzhen Morlab Communications Technology Co., Ltd., to act on the behalf of the Anker Innovations Limited solely in matters relating to the application for an FCC equipment authorization for FCC ID: 2AOKB-D2421X including the signing of documents in connection with this Application. Necessary acts carried outShenzhen Morlab Communications Technology Co., Ltd.on our behalf of theAnker Innovations Limited in connection with theApplication shall have the same effect as acts of the Anker Innovations Limited also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Thank you for your attention to this matter. Yours Sincerely, Signatory: Contact name: Louis Qi Tel: +86-13652441319 Email: [email protected] Company name : Anker Innovations Limited

Cover Letter(s)

Anker Innovations Limited UNII Declaration Letter We have declared below featured for FCC equipment authorization, device FCC ID: 2AOKB-D2421X (1) DFS Device -- Master, Client with Radar detection capability , Client without radar detection capability, N/A (2) Active / Passive Scanning , adhoc mode access point capability Frequency Band (MHz) Active Scanning (the device can transmit a probe (beacon)) passive scanning (where the device is can listen only with no probes) Ad Hoc Mode capability Access point capability 2412 – 2462 MHz Yes, No Yes, No Yes, No Yes, No 2422 – 2452 MHz Yes, No Yes, No Yes, No Yes, No 5745 – 5825 MHz Yes, No Yes, No Yes, No Yes, No 5755 – 5795 MHz Yes, No Yes, No Yes, No Yes, No 5180 – 5240 MHz Yes, No Yes, No Yes, No Yes, No 5190 – 5230 MHz Yes, No Yes, No Yes, No Yes, No 5260 – 5320 MHz Yes, No Yes, No Yes, No Yes, No 5270 – 5310 MHz Yes, No Yes, No Yes, No Yes, No 5500 – 5700 MHz Yes, No Yes, No Yes, No Yes, No 5510 – 5670 MHz Yes, No Yes, No Yes, No Yes, No (3) Country code selection ability - Yes , No If no, pls explain how was implemented : Country is selected as US by default and user can not change the country code. (4) Meet 15.202 requirement - Yes , No , pls check below : A master device is defined as a device operating in a mode in which it has the capability to transmit without receiving an enabling signal. In this mode it is able to select a channel and initiate a network by sending enabling signals to other devices A client device is defined as a device operating in a mode in which the transmissions of the device are under control of the master. A device in client mode is not able to initiate a network. N/A (5) For client devices that have software configuration control to operate in different modes (active scanning in some and passive scanning in others) in different bands (devices with multiple equipment classes or those that operate on non-DFS frequencies) or modular devices which configure the modes of operations through software, the application must provide software and operations description on how the software and / or hardware is implemented to ensure that proper operations modes can not be modified by end user or an installer. Apply , No Apply , (If apply , pls help to provide explanation on how it was implement (By hardware or software , and how software was controlled) The device configuration can not be modified by user as program is not exposed to user by any means. Hardware does not allow USB connection for user which is must to change the configuration. If you have any questions, please feel free to contact me at the address shown below. Yours sincerely, Signatory Contact name: Louis Qi Tel: +86-13652441319 Email: [email protected] Company name : Anker Innovations Limited

External Photos

FCC ID: 2AOKB-D2421X MODEL NAME: D2421 External Photos 1. EUT front view 2. EUT rear view 3. EUT left side view 4. EUT right side view 5. EUT top view 6. EUT bottom view 7. Accessories

ID Label/Location Info

1. Label 2. Label location

Internal Photos

FCC ID: 2AOKB-D2421X MODEL NAME: D2421 Internal Photos 1. EUT uncover view 2. Antenna view CGBT030 Bluetooth Antenna DM8260 Bluetooth /2.4G Wifi Antenna

RF Exposure Info

MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.:SZ21040408S01 Annex E SATIMO&DASY Calibration Certificate Ref : ACR.189.1.16.SATU.A SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY CO., LTD FL3, BUILDING A, FEIYANG SCIENCE PARK, NO.8 LONGCHANG ROAD, BLOCK 67, BAOAN DISTRICT, SHENZHEN, GUANGDONG PROVINCE, P.R. CHINA MVG COMOSAR DOSIMETRIC E-FIELD PROBE SERIAL NO.: SN 37/08 EP80 Calibrated at MVG US 2105 Barrett Park Dr. - Kennesaw, GA 30144 Calibration Date: 10/05/2018 Summary: This document presents the method and results from an accredited COMOSAR Dosimetric E-Field Probe calibration performed in MVG USA using the CALISAR / CALIBAIR test bench, for use with a COMOSAR system only. All calibration results are traceable to national metrology institutions. COMOSAR E-Field Probe Calibration Report COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.189.1.16.SATU.A Page: 2/9 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Name Function Date Signature Prepared by : Jérôme LUC Product Manager 17/5/2018 Checked by : Jérôme LUC Product Manager 17/5/2018 Approved by : Kim RUTKOWSKI Quality Manager 17/5/2018 Customer Name Distribution : Shenzhen Morlab Communications Technology Co., Ltd Issue Date Modifications A 17/5/2018 Initial release COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.189.1.16.SATU.A Page: 3/9 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. TABLE OF CONTENTS 1 Device Under Test ..................................................................................................... 4 2 Product Description ................................................................................................... 4 2.1 General Information _______________________________________________________ 4 3 Measurement Method ................................................................................................ 4 3.1 Linearity ________________________________________________________________ 4 3.2 Sensitivity _______________________________________________________________ 5 3.3 Lower Detection Limit _____________________________________________________ 5 3.4 Isotropy _________________________________________________________________ 5 3.5 Boundary Effect __________________________________________________________ 5 4 Measurement Uncertainty .......................................................................................... 5 5 Calibration Measurement Results .............................................................................. 6 5.1 Sensitivity in air __________________________________________________________ 6 5.2 Linearity ________________________________________________________________ 7 5.3 Sensitivity in liquid ________________________________________________________ 7 5.4 Isotropy _________________________________________________________________ 8 6 List of Equipment ...................................................................................................... 9 COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.189.1.16.SATU.A Page: 4/9 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 1 DEVICE UNDER TEST Device Under Test Device Type COMOSAR DOSIMETRIC E FIELD PROBE Manufacturer MVG Model SSE5 Serial Number SN 37/08 EP80 Product Condition (new / used) Used Frequency Range of Probe 0.7 GHz-3GHz Resistance of Three Dipoles at Connector Dipole 1: R1=1.445 M Dipole 2: R2=1.467 M Dipole 3: R3=1.477 M A yearly calibration interval is recommended. 2 PRODUCT DESCRIPTION 2.1 GENERAL INFORMATION MVG’s COMOSAR E field Probes are built in accordance to the IEEE 1528, OET 65 Bulletin C and CEI/IEC 62209 standards. Figure 1 – MVG COMOSAR Dosimetric E field Dipole Probe Length 330 mm Length of Individual Dipoles 4.5 mm Maximum external diameter 8 mm Probe Tip External Diameter 5 mm Distance between dipoles / probe extremity 2.7 mm 3 MEASUREMENT METHOD The IEEE 1528, OET 65 Bulletin C, CENELEC EN50361 and CEI/IEC 62209 standards provide recommended practices for the probe calibrations, including the performance characteristics of interest and methods by which to assess their affect. All calibrations / measurements performed meet the fore mentioned standards. 3.1 LINEARITY The evaluation of the linearity was done in free space using the waveguide, performing a power sweep to cover the SAR range 0.01W/kg to 100W/kg. COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.189.1.16.SATU.A Page: 5/9 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 3.2 SENSITIVITY The sensitivity factors of the three dipoles were determined using a two step calibration method (air and tissue simulating liquid) using waveguides as outlined in the standards. 3.3 LOWER DETECTION LIMIT The lower detection limit was assessed using the same measurement set up as used for the linearity measurement. The required lower detection limit is 10 mW/kg. 3.4 ISOTROPY The axial isotropy was evaluated by exposing the…

Text truncated - open the document above for the full version.

RF Exposure Info

MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORTNo.:SZ21040408S01 Annex C Plots of System Performance Check System Performance Check Data(2450MHz Body) Type: Phone measurement (Complete) Area scan resolution: dx=12mm,dy=12mm Zoom scan resolution: dx=5mm, dy=5mm, dz=4mm Date of measurement: 2019.03.18 Measurement duration: 14 minutes 31 seconds A. Experimental conditions. Phantom File surf_sam_plan.txt Phantom Flat Device Position Band 2450MHz Channels Signal CW B. SAR Measurement Results Frequency (MHz) 2450.000000 Relative permittivity (real part) 52.874446 Conductivity (S/m) 1.965143 Power Drift (%) 1.030000 Ambient Temperature: 22.7°C Liquid Temperature: 22.2°C ConvF: 4.96 Crest factor: 1:1 SURFACE SAR VOLUME SAR MORLA Z S (W AB Shenzh FL1-3, B Block67 S SA (mm) 0 SAR W/Kg) 0. 3 hen Morlab Commun Building A, FeiYang S 7, BaoAn District, Sh M AR 10g (W AR 1g (W 0.00 4 0000 12 3D sceen s ications Technology C Science Park, No.8 L enZhen , GuangDon Maximum l W/Kg) W/Kg) 4.00 9 .9615 6.2 shot Co., Ltd. LongChang Road, ng Province, P. R. Ch location: X Z Axis Sca 9.00 14 2096 3.8 ina Te l : 8 Http: R X=6.00, Y=1 an 4.00 19 8187 2.4 Ho 86-755-36698555 //www.morlab.cn REPORTN .00 2.37825 0 5.083174 9.00 24 4504 1.5 ot spot pos Fax: 86-755-3669 E-mail: service@ No.:SZ21 0 4 4.00 29 5036 1.0 sition 98525 @morlab.cn 1040408S0 9.00 0219 01 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORTNo.:SZ21040408S01 System Performance Check Data(5200MHz Body) Type: Phone measurement (Complete) Area scan resolution: dx=10mm,dy=10mm Zoom scan resolution: dx=4mm, dy=4mm, dz=2mm Date of measurement: 2019.03.18 Measurement duration: 23 minutes 29 seconds A. Experimental conditions. Phantom File surf_sam_plan.txt Phantom Validation plane Device Position Band 5200MHz Channels Signal CW B. SAR Measurement Results Band SAR Frequency (MHz) 5200.000000 Relative permittivity (real part) 48.993014 Conductivity (S/m) 5.543260 Power Drift (%) 2.310000 Ambient Temperature: 21.1°C Liquid Temperature: 22.8°C ConvF: 22.11 Crest factor: 1:1 SURFACE SAR VOLUME SAR MORLA AB Shenzh FL1-3, B Block67 S SA hen Morlab Commun Building A, FeiYang S 7, BaoAn District, Sh M AR 10g (W AR 1g (W ications Technology C Science Park, No.8 L enZhen , GuangDon Maximum l W/Kg) W/Kg) Co., Ltd. LongChang Road, ng Province, P. R. Ch location: X Z Axis Sca ina Te l : 8 Http: R X=1.00, Y=3 an 86-755-36698555 //www.morlab.cn REPORTN .00 5.63235 5 16.28542 Fax: 86-755-3669 E-mail: service@ No.:SZ21 5 2 98525 @morlab.cn 1040408S0 01 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORTNo.:SZ21040408S01 System Performance Check Data(5800MHz Body) Type: Phone measurement (Complete) Area scan resolution: dx=10mm,dy=10mm Zoom scan resolution: dx=4mm, dy=4mm, dz=2mm Date of measurement: 2019.03.18 Measurement duration: 23 minutes30 seconds A. Experimental conditions. Phantom File surf_sam_plan.txt Phantom Validation plane Device Position Band 5800MHz Channels Signal CW B. SAR Measurement Results Band SAR Frequency (MHz) 5800.000000 Relative permittivity (real part) 48.093428 Conductivity (S/m) 5.942716 Power Drift (%) 1.260000 21.3°C 21.3°C 22.1°C 22.8°C ConvF: 23.02 Crest factor: 1:1 SURFACE SAR VOLUME SAR MORLA AB Shenzh FL1-3, B Block67 S SA hen Morlab Commun Building A, FeiYang S 7, BaoAn District, Sh M AR 10g (W AR 1g (W ications Technology C Science Park, No.8 L enZhen , GuangDon Maximum lo W/Kg) W/Kg) Co., Ltd. LongChang Road, ng Province, P. R. Ch ocation: X= Z Axis Sca ina Te l : 8 Http: R =-6.00, Y=-1 an 86-755-36698555 //www.morlab.cn REPORTN 1.00 5.97263 4 17.685290 Fax: 86-755-3669 E-mail: service@ No.:SZ21 4 0 98525 @morlab.cn 1040408S0 01 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2022.6.29 System Check_5750MHz_Head Communication System: UID 0, CW (0); Frequency: 5750 MHz;Duty Cycle: 1:1 Medium: HSL_5750 Medium parameters used: f = 5750 MHz; σ = 5.011 S/m; ε r = 36.158; ρ = 1000 kg/m 3 Ambient Temperature:23.2 °C; Liquid Temperature:22.1 °C DASY5 Configuration: - Probe: EX3DV4 - SN3753; ConvF(4.65, 4.65, 4.65) @ 5750 MHz; Calibrated: 2021.07.26 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1643; Calibrated: 2021.12.30 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) CW5750/Area Scan (101x101x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm Maximum value of SAR (interpolated) = 18.9 W/kg CW5750/Zoom Scan (7x7x13)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 42.02 V/m; Power Drift = -0.16 dB Peak SAR (extrapolated) = 38.6 W/kg SAR(1 g) = 8.24 W/kg; SAR(10 g) = 2.31 W/kg Maximum value of SAR (measured) = 19.0 W/kg 0 dB = 19.0 W/kg

RF Exposure Info

MORLA Anne Type: Ph Pa Pa Date of m Measure A. Expe B. SAR Re AB Shenzh FL1-3, B Block67 ex D P hone meas arameter ar arameter zo measurem ement dura rimental C Ph D Ch S Measurem C Frequ lative perm Condu Powe Ambient Liquid T C Dut SURF en Morlab Communi Building A, FeiYang S 7, BaoAn District, She Plots o surement ( rea scan=s oom scan= ment: 2019. ation: 16 m Conditions hantom Device Band hannels Signal ment Resu Channel uency (MH mittivity (r uctivity (S/ er drift (% t Temperat Temperatu ConvF: ty Cycle: FACE SAR Maximu ications Technology C Science Park, No.8 L enZhen , GuangDon of Max MEA Complete) step 12 mm =dx=5mm, 03.18 minutes 49 s. ults. Hz) real part) /m) %) ture: ure: R um locatio Co., Ltd. LongChang Road, g Province, P. R. Ch imum ASUREME ) m dy=5mm, seconds on: X=-1.0 ina Te l : 8 Http:/ RE SAR T ENT 1 dz=4mm IE 00000 Y=1 86-755-36698555 //www.morlab.cn EPORT No Test R Body Plane EEE 802.11 HIGH IEEE 80 11 2462.0 52.688 1.973 -1.42 22.7°C 22.2°C 4.96 1:1.0 VOLUME 12.000000 Fax: 86-755-3669 E-mail: service@ o.:SZ210 Results y e 1b ISM H 2.b 0 8 3 C C SAR 98525 @morlab.cn 040408S01 s 1 MORLA Z (mm) SAR (W/K g) AB Shenzh FL1-3, B Block67 SAR SAR 1 0.00 0.01031 7 3D sc hen Morlab Commun Building A, FeiYang S 7, BaoAn District, Sh 10g (W/Kg 1g (W/Kg 4.00 0.00392 3 creen sho ications Technology C Science Park, No.8 L enZhen , GuangDon SAR Pe g) g) 8.00 0.00091 4 ot Co., Ltd. LongChang Road, ng Province, P. R. Ch eak: 0.009 12.00 0.00102 5 ina Te l : 8 Http: RE 9823 W/kg 16.00 0.00102 2 H 86-755-36698555 //www.morlab.cn EPORT No 0.01597 0.03836 20.00 0.00101 8 Hot spot p Fax: 86-755-3669 E-mail: service@ o.:SZ210 71 65 24.00 0.00100 3 ositio 98525 @morlab.cn 040408S01 28.00 00.00101 5 1 1 MORLA Type: Ph Pa Pa Date of m Measure A. Expe B. SAR Re AB Shenzh FL1-3, B Block67 hone meas arameter ar arameter zo measurem ement dura rimental C Ph D Ch S Measurem C Frequ lative perm Condu Powe Ambient Liquid T C Dut SURF hen Morlab Commun Building A, FeiYang S 7, BaoAn District, Sh surement ( rea scan=s oom scan= ment: 2019. ation: 17 m Conditions hantom Device Band hannels Signal ment Resu Channel uency (MH mittivity (r uctivity (S/ er drift (% t Temperat Temperatu ConvF: ty Cycle: FACE SAR Maximu ications Technology C Science Park, No.8 L enZhen , GuangDon MEA Complete) step 10 mm =dx=4mm, 03.18 minutes 42 s. ults. Hz) real part) /m) %) ture: ure: R um locatio Co., Ltd. LongChang Road, ng Province, P. R. Ch ASUREME ) m dy=4mm, seconds on: X=19.0 ina Te l : 8 Http: RE ENT 2 dz=2mm IE 000000 Y=1 86-755-36698555 //www.morlab.cn EPORT No Body Plane EE 802.11 HIGH IEEE 80 48 5240.0 48.903 5.606 -2.67 21.1°C 22.8°C 22.11 1:1.0 VOLUME 19.000000 Fax: 86-755-3669 E-mail: service@ o.:SZ210 y e a U-NII H 2.a 0 3 6 C C SAR 0 98525 @morlab.cn 040408S01 1 MORLA Z (mm) SAR (W/K g) AB Shenzh FL1-3, B Block67 SAR SAR 1 0.00 0.07435 6 3D sc hen Morlab Commun Building A, FeiYang S 7, BaoAn District, Sh 10g (W/Kg 1g (W/Kg 4.00 0.03410 2 creen sho ications Technology C Science Park, No.8 L enZhen , GuangDon SAR Pe g) g) 6.00 0.02139 5 ot Co., Ltd. LongChang Road, ng Province, P. R. Ch eak: 0.068 8.00 0.01703 9 ina Te l : 8 Http: RE 8852 W/kg 10.00 0.01424 9 H 86-755-36698555 //www.morlab.cn EPORT No 0.02209 0.03578 12.00 0.01317 2 Hot spot p Fax: 86-755-3669 E-mail: service@ o.:SZ210 99 88 14.00 70.01181 4 ositio 98525 @morlab.cn 040408S01 16.00 0.01203 5 1 3 MORLA Type: Ph Pa Pa Date of m Measure A. Expe B. SAR Re AB Shenzh FL1-3, B Block67 hone meas arameter ar arameter zo measurem ement dura rimental C Ph D Ch S Measurem C Frequ lative perm Condu Powe Ambient Liquid T C Dut SURF hen Morlab Commun Building A, FeiYang S 7, BaoAn District, Sh surement ( rea scan=s oom scan= ment: 2019. ation: 18 m Conditions hantom Device Band hannels Signal ment Resu Channel uency (MH mittivity (r uctivity (S/ er drift (% t Temperat Temperatu ConvF: ty Cycle: FACE SAR Maximu ications Technology C Science Park, No.8 L enZhen , GuangDon MEA Complete) step 10 mm =dx=4mm, 03.18 minutes 4 s s. ults. Hz) real part) /m) %) ture: ure: R um locatio Co., Ltd. LongChang Road, ng Province, P. R. Ch ASUREME ) m dy=4mm, econds on: X=11.0 ina Te l : 8 Http: RE ENT 3 dz=2mm IE 000000 Y=1 86-755-36698555 //www.morlab.cn EPORT No Body Plane EE 802.11 HIGH IEEE 80 165 5825.0 47.999 6.001 0.87 21.3°C 22.8°C 23.02 1:1.0 VOLUME 18.000000 Fax: 86-755-3669 E-mail: service@ o.:SZ210 y e a U-NII H 2.a 0 9 C C 2 SAR 0 98525 @morlab.cn 040408S01 1 MORLA Z (mm) SAR (W/K g) AB Shenzh FL1-3, B Block67 SAR SAR 1 0.00 0.18112 5 3D sc hen Morlab Commun Building A, FeiYang S 7, BaoAn District, Sh 10g (W/Kg 1g (W/Kg 4.00 0.07130 0 creen sho ications Technology C Science Park, No.8 L enZhen , GuangDon SAR Pe g) g) 6.00 0.04010 1 ot Co., Ltd. LongChang Road, ng Province, P. R. Ch eak: 0.175 8.00 0.02609 7 ina Te l : 8 Http: RE 5955 W/kg 10.00 0.01829 5 H 86-755-36698555 //www.morlab.cn EPORT No 0.03741 0.07557 12.00 0.01682 3 Hot spot p Fax: 86-755-3669 E-mail: service@ o.:SZ210 19 75 14.00 0.01387 4 ositio 98525 @morlab.cn 040408S01 16.00 70.01351 7 1 1 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2022.06.29 WLAN 5.8GHz_802.11a 6Mbps_Top Side_0mm_Ch165 Communication System: UID 0, WLAN 5GHz (0); Frequency: 5825 MHz;Duty Cycle: 1:1 Medium: HSL_5750 Medium parameters used: f = 5825 MHz; σ = 5.388 S/m; ε r = 35.018; ρ = 1000 kg/m 3 Ambient Temperature:23.2 °C; Liquid Temperature:22.1 °C DASY5 Configuration: - Probe: EX3DV4 - SN3753; ConvF(4.65, 4.65, 4.65) @ 5825 MHz; Calibrated: 2021.07.26 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1643; Calibrated: 2021.12.30 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) Ch165/Area Scan (101x111x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm Maximum value of SAR (interpolated) = 0.179 W/kg Ch165/Zoom Scan (8x8x15)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 0 …

Text truncated - open the document above for the full version.

RF Exposure Info

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 50 REPORT No.:SZ21040408S01 TEST REPORT APPLICANT : Anker Innovations Limited PRODUCT NAME : Nebula Capsule II MODEL NAME : D2421 BRAND NAME : NEBULA FCC ID : 2AOKB-D2421X STANDARD(S) : FCC 47 CFR Part 2(2.1093) RECEIPT DATE : 2018-12-06 TEST DATE : 2019-03-18 to 2022-06-29 ISSUE DATE : 2022-08-05 Edited by: Xie Yiyun (Rapporteur) Approved by: Shen Junsheng (Supervisor) REPORT No.:SZ21040408S01 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555Fax: 86-755-36698525 Http://www.morlab.cnE-mail: [email protected] Page 2 of 50 DIRECTORY 1 SAR Results Summary .............................................................................................................................. 4 2 Technical Information ................................................................................................................................ 5 2.1 Applicant and Manufacturer Information ................................................................................................................. 5 2.2 Equipment under Test (EUT) Description ................................................................................................................ 5 2.3 Accessories Information ............................................................................................................................................. 6 2.4 Environment of Test Site ............................................................................................................................................. 7 3 Specific Absorption Rate (SAR) .............................................................................................................. 8 3.1 Introduction ................................................................................................................................................................... 8 3.2 SAR Definition............................................................................................................................................................... 8 4 RF Exposure Limits ................................................................................................................................... 9 4.1 Uncontrolled Environment .......................................................................................................................................... 9 4.2 Controlled Environment .............................................................................................................................................. 9 4.3 RF Exposure Limits ...................................................................................................................................................... 9 4.4 Applied Reference Documents ................................................................................................................................ 11 5 SAR Measurement System ..................................................................................................................... 12 5.1 SAR Measurement System for SATIMO .................................................................................................................. 12 5.2 SAR Measurement System for DASY 5 ................................................................................................................... 16 5.3 Test Equipment List ................................................................................................................................................... 23 6 Tissue Simulating Liquids ...................................................................................................................... 25 7 SAR System Verification ......................................................................................................................... 28 8 EUT Testing Position ............................................................................................................................... 32 8.1 SAR Evaluations near the Mouth/Jaw Regions of the SAM Phantom ............................................................... 32 8.2 Body Worn Accessory Configurations ................................................................................................................... 32 9 Measurement Procedures ........................................................................................................................ 33 9.1 Power Reference Measurement ............................................................................................................................... 33 9.2 Area Scan Procedures ............................................................................................................................................... 34 9.3 Zoom Scan Procedures ............................................................................................................................................. 34 9.4 SAR Averaged Methods ............................................................................................................................................ 34 10 SAR Test Procedure ..................................................................................................…

Text truncated - open the document above for the full version.

Test Report

AntennaSPEC Customer:WanlidaGroupCo.,Ltd . ProjectName:MPD-J011 WorkingBand:2400~2500MHz MainboardVersion:SA08407778 AdmissionVersion:A SunnywayBOM SPEC-TypeSunnyway Antenna BTAntennaFZ034IB75 SunnywayCountersignColumn R&D ME:林锋Audit:陈金林 QualityEngineer: 陈小平 Approval: 陈金林 RF:姜昊Audit:陈金林 CustomerCountersignColumn ElectronicEngineerProjectManagerStructuralEngineerQualityEngineer Tel:+86-021-64842326(Shanghai) +86-0755-82504258(Shenzhen) +86-0591-87862232(Fuzhou) Fax:+86-021-64842328 ShanghaiR&Dcenter:Room302,building65,No.421,HongCaoRoad,CaohejingDevelopmentZone,Shanghai. ShenzhenR&DCenter:Room405,4thFloor,JinkeBuilding,No.8QiongyuRoad,NanshanD…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Louis Qi
[email protected]+86-755-86544807Fax: N/A

Technical Contact

Shenzhen Morlab Communications Technology Co., LtdWendy Zhan
[email protected]86075536698541

FL.1, Building A, FeiYang Science Park, No.8 · GuangDong · China

Non-Technical Contact

Shenzhen Morlab Communications Technology Co., LtdWendy Zhan
[email protected]86075536698541

Test Firm

Shenzhen Morlab Communications Technology Co. Ltd.Mr. Su Feng
[email protected]+86 755 36698566

Technical Specifications

#Rule PartsFrequency RangePower Output
215E5.75 GHz - 5.83 GHz96.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 0mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for stand-alone transmission exposure conditions is 0.09 W/kg, respectively. This device supports 20 MHz, 40 MHz and 80 MHz bandwidth modes.

Other Applications from Anker Innovations Limited

2AOKB-D1105R

ANKER AeroClip 2

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
2AOKB-D1105L

ANKER AeroClip 2

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
Anker MagGo Power Bank 2 Pro - FCC ID 2AOKB-A110R - Anker Innovations Limited
2AOKB-A110R

Anker MagGo Power Bank 2 Pro

Aug 19, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2AOKB-D1206R

Anker soundcore Liberty Buds 2

Aug 05, 2026

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
2AOKB-D1206L

Anker soundcore Liberty Buds 2

Aug 05, 2026

Equipment Class

DTS - Digital Transmission System