Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Anker Innovations Limited Add: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong Tel: +86-75586544807 Email: [email protected] Attestation Letter Date: 2026-07-10 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir or Madam: Our product eufyCam C33,eufyCam C32, model: T8119,FCC ID:2AOKB-T8119, for marketing purpose, this product only supports 2.4G Wi-Fi(2412-2462MHz, 802.11b/g/n20 modes).The other functions, bands and modes was disabled to use by manufacturer in the software, the end user has no capability to activate it. Sincerely, Printed Name: Justin Zhou Title: Testing and Compliance Director
Anker Innovations Limited Add: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong Tel: +86-75586544807 Email: [email protected] CFR 47 §2.911(d)(5)(i)(ii) Attestation Letter Attestation Letter Date: 2026-07-10 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i)(ii) Filing FCC ID:2AOKB-T8119 Anker Innovations Limited (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Anker Innovations Limited (“the applicant”) certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Anker Innovations Limited certifies that the equipment does not use Kaspersky's software information. Sincerely, Signature Printed Name: Justin Zhou Title: Testing and Compliance Director
2.911(d)(7)USAAgentv1.2 Section2.911(d)(7)USAAgentforServiceofProcess Companyname:AnkerInnovationsLimited Address:Unit56,8thFloor,Tower2,AdmiraltyCentre,18HarcourtRoad,HongKong FRN:0027073105 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[[AnkerInnovationsLimited](“theapplicant”)designate[[FantasiaTradingLLC] NOTE1 forthepurposeofacceptingserviceofprocessonbehalfoftheapplicant. Applicantconsent:WeAcknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminated allmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolving theequipment,whicheverislater. Agentobligation:WeAcknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,ortheconclusionofanyCommission-relatedadministrativeorjudicial proceedinginvolvingtheequipment,whicheverislater. USAAgent Companyname:FantasiaTradingLLC Address:5350OntarioMillsPkwy,STE100, Ontario,CA91764,UnitedStates FRN:0033423005 ContactName:ConnorZhai TelephoneNo:(800)988-7973 Email:[email protected] Applicant Companyname:AnkerInnovations Limited Address:Unit56,8thFloor,Tower2, AdmiraltyCentre,18HarcourtRoad, HongKong FRN:0027073105 ContactName:JustinZhou TelephoneNo:+86-755-86544807 Email:[email protected] Signature: Title:GeneralManager Signature: Title:ComplianceManager Date:2026/01/27Date:2026/01/27 2.911(d)(7)USAAgentv1.2 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the
QA-FR-170-B Anker Innovations Limited Add: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong Tel: +86-75586544807 Email: [email protected] FCC Authorization Date: 2026-07-10 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We , Anker Innovations Limited, Hereby authorizes Bay Area Compliance Laboratories Corporation(Shenzhen) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corporation(Shenzhen) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Client’s signature Printed Name: Justin Zhou Title: Testing and Compliance Director
QA-FR-172-A Anker Innovations Limited Add: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong Tel: +86-75586544807 Email: [email protected] FCC Confidential Authorization Date: 2026-07-10 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID:2AOKB-T8119 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Anker Innovations Limited hereby requests long-term confidential treatment of information accompanying this application as outlined below: • Block Diagram • Schematics • Operation Description As well as short-term (secrecy cycle: 180 days) confidential treatment of information accompanying this application as outlined below: • Internal Photos • User’s Manual • External Photos • Test Set-up Photos The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature Printed Name: Justin Zhou Title: Testing and Compliance Director
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601U64266E-RFB TR-EM-RF012 Page 28 of 97 Version 4.2 RF EXPOSURE EVALUATION MPE-Based Exemption Applicable Standard According to subpart 2.1091 systems operating under the provisions of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in excess of the communication guidelines. According to KDB 447498 D04 v01 Interim General RF Exposure Guidance MPE-Based Exemption: General frequency and separation-distance dependent MPE-based effective radiated power(ERP) thresholds are in Table B.1 [Table 1 of § 1.1307(b)(3)(i)(C)] to support an exemption from further evaluation from 300 kHz through 100 GHz. R is the minimum separation distance in meters f = frequency in MHz Result Antenna Gain # ERP Mode Frequency (MHz) Tune up conducted power # (dBm) (dBi)(dBd)(dBm)(mW) Evaluation Distance (m) ERP Limit (mW) 2.4G Wi-Fi 2412-246223.02.740.59 23.59 228.56 0.2768 Note: The tune up conducted power and antenna gain was declared by the applicant. To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm from nearby persons. Result: Compliant
DongguanYoubiElectronicsCo.,LTD DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 1 /11 Sampleacceptancecertificate Documentversionnumber:A2 client Contract manufacturing Materialsupplier Nameofpartner:Anker/Youbi projectname: C33/C33 Materialnumber: UB01NF1D1701A Material description: 2.4GFPCBuilt-inAntenna Dateof acknowledgement: 2026-06-08 Versionoftheletter acknowledged: V1 Signatureexplanation:1.Thisletterofrecognitionshallbeinatleast5copies,onecopyforanchor R&DandSQErespectively,onecopyformaterialmanufacturerandOEM Keeptwocopiesinthefactory; 2.AnkerEachownersignatureshallbesignedwiththefullEnglishnameofthecompany. 3.First,sendtheelectronicfiletoAnker'scorrespondingR&DandSQEforconfirmation. AfterOK,sendthepaperfileforsignatureandapproval. Supplierconfirmation researchanddevelopmentcharacter Ankerapproval Smartresearchanddevelopment ZhiXinMD/HW/ID/certification ZhiXinSQE DongguanYoubiElectronicsCo.,LTD DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 2 /11 Declaration APPROVALSHEET CUSTOMERNAME:Anker Productname 2.4GFPCBuilt-inAntenna CUSTOMERP/N: YoubiP/N:UB01NF1D1701AREV:A MANUFACTURER SIGNATURE CUSTOMER SIGNATURE CHECKEDBY: Lina APPROVEDBY:Yuefei.zhu DATE:2026/06/08 DongguanYoubiElectronicsCo.,LTD DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 3 /11 catalogue ( CONTENTS ) 1.Revisionhistory 2.Product2Ddrawings 3.Testequipment 4.AntennaS11 5.Antennaefficiencyandgain 6.Antenna2D/3Dradiationpattern 7.Fullsizetestreport DongguanYoubiElectronicsCo.,LTD DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 4 /11 1.Revisionhistory VersionContentRevisionIssuedbyDate AOriginalversionlina2026-06-08 DongguanYoubiElectronicsCo.,LTD DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 5 /11 2.Product2Ddrawings DongguanYoubiElectronicsCo.,LTD DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 6 /11 DongguanYoubiElectronicsCo.,LTD DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 7 /11 3.Testequipment TestitemsTestequipment SParameter 1.ReturnLoss 2.VSWR Networkanalyzer (AgilentE5071B) Thewholemachineof Passiveparameters 1.Frequency 2.Gain 3.RadiationPattern 1.3Dmicrowavedarkroom (5m*5m*5m) 2.Networkanalyzer (AgilentE5071B) Thewholemachineof Activeparameters 1.TRP 2.TIS 1.3Dmicrowavedarkroom (5m*5m*5m) 2.Comprehensivetestinstrument (CMW500) DongguanYoubiElectronicsCo.,LTD DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 8 /11 4.AntennaS11 *VoltageStandingWaveRatio(VSWR) ReturnLoss(RL) RL=20*log10[(VSWR+1)/(VSWR-1) Frequency(MHz)VSWR ReturnLoss(dB) 24001.16-22.13 25001.33-16.90 DongguanYoubiElectronicsCo.,LTD DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 9 /11 5.Antennaefficiencyandgain Frequency/MhzEfficiency/dBEfficiency/%MaxGain/dBi 2400-1.7267.32.3 2410-1.8765.012.52 2420-1.6967.762.74 2430-1.8765.012.67 2440-1.866.072.71 2450-1.6468.552.49 2460-1.9164.422.49 2470-1.7766.532.41 2480-1.8265.772.41 2490-2.0562.372.29 2500-1.8165.922.27 DongguanYoubiElectronicsCo.,LTD DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 10 /11 6.Antenna2D/3Dradiationpattern Phi02DPhi902D Theta902D 2450MHZ DongguanYoubiElectronicsCo.,LTD DongguanYoubiEl…
Text truncated - open the document above for the full version.
Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF012 Page 1 of 97 Version 4.2 TEST REPORT Applicant Name:Anker Innovations Limited Address:Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong Report Number:2601U64266E-RFB FCC ID:2AOKB-T8119 IC:23451-T8119 Test Standard (s) FCC PART 15.247; RSS-GEN ISSUE 5, FEBRUARY 2021 AMENDMENT 2; RSS-247, ISSUE 4, JULY 2025 Sample Description Product Type:eufyCam C33, eufyCam C32 Model No.:T8119 Multiple Model(s) No.:N/A Trade Mark:eufy Date Received:2026-06-15 Issue Date:2026-07-20 Test Result:Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By:Approved By: Wills YuNancy Wang RF EngineerRF Supervisor Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601U64266E-RFB TR-EM-RF012 Page 2 of 97 Version 4.2 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ..........................................................................................................................3 GENERAL INFORMATION ........................................................................................................................................4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)......................................................................................4 OBJECTIVE ....................................................................................................................................................................4 TEST METHODOLOGY....................................................................................................................................................4 MEASUREMENT UNCERTAINTY .....................................................................................................................................5 TEST FACILITY ..............................................................................................................................................................5 SYSTEM TEST CONFIGURATION ...........................................................................................................................6 SUMMARY OF TEST RESULTS ................................................................................................................................9 TEST EQUIPMENT LIST ..........................................................................................................................................10 REQUIREMENTS AND TEST PROCEDURES ......................................................................................................12 AC LINE CONDUCTED EMISSIONS...............................................................................................................................12 SPURIOUS EMISSIONS ..................................................................................................................................................15 99% OCCUPIED BANDWIDTH & 6 DB EMISSION BANDWIDTH ....................................................................................18 MAXIMUM CONDUCTED OUTPUT POWER ...................................................................................................................21 POWER SPECTRAL DENSITY ........................................................................................................................................22 100 KHZ BANDWIDTH OF FREQUENCY BAND EDGE....................................................................................................23 CONDUCTED SPURIOUS EMISSION...............................................................................................................................25 DUTY CYCLE ...............................................................................................................................................................27 RF EXPOSURE EVALUATION ................................................................................................................................28 ANTENNA REQUIREMENT .....................................................................................................................................30 TEST DATA AND RESULTS .....................................................................................................................................32 AC LINE CONDUCTED EMISSIONS...............................................................................................................................32 SPURIOUS EMISSIONS ..................................................................................................................................................35 99% OCCUPIED BANDWIDTH ......................................................................................................................................75 6DB EMISSION BANDWIDTH........................................................................................................................................79 MAX…
Text truncated - open the document above for the full version.
5350 Ontario Mills Pkwy, STE 100 · Ontario, California, 91764 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 173.00 mW |
Anker SOLIX S5000 Portable Power Station
Equipment Class
DTS - Digital Transmission SystemAnker MagGo Power Bank (10K,Slim)
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzAnker Nano Power Bank (5K, MagGo, Slim)
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzANKER AeroClip 2
Equipment Class
DTS - Digital Transmission SystemANKER AeroClip 2
Equipment Class
DTS - Digital Transmission System