FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Anker Innovations Limited/
  3. 2AOKB-T90G0

2AOKB-T90G0eufy Glass Break Sensor E10

Anker Innovations Limited

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jun 22, 2026
Application Purpose
Original Equipment
Equipment Note
eufy Glass Break Sensor E10
Frequency Range
920.00000000 - 920.80000000
Company
Anker Innovations Limited
Country
Hong Kong

Documents & Files

Select a file to view

Attestation Statements

β†—
β†—

Cover Letter(s)

β†—
β†—

ID Label/Location Info

β†—

RF Exposure Info

β†—

Test Report

β†—
β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

FantasiaTradingLLC To:FederalCommunicationsCommissionDate: 2026/04/017435OaklandMillsRoad Columbia,MD21046 USA Attestation CertificationdesignatingaU.S.AgentforServiceofProcess Section2.911(d)(7) (KDB986446D01CoveredEquipment) AnkerInnovationsLimitedasrequiredbysection2.911(d)(7),designatebelowcontact locatedintheUnitedStatesforpurposesofactingastheapplicant’sagentforserviceof process.Theapplicantalsoacceptancetomaintainanagentfornolessthanoneyear afterthegranteehasterminatedallmarketingandimportationortheconclusionofany Commission-relatedproceedinginvolvingtheequipment. TypeofEquipmentsubjecttoFCCCertification:eufyGlassBreakSensorE10 FCCID:2AOKB-T90G0 Sincerelyyours, Applicant/GranteeUSAgent (Signature) AnkerInnovationsLimited FRN:0027073105 JustinZhou Manager [email protected] Unit56,8thFloor,Tower2, AdmiraltyCentre,18HarcourtRoad, HongKong (Signature) FantasiaTradingLLC FRN:0033423005 ConnorZhai ComplianceManager [email protected] 5350OntarioMillsPkwy,STE100,Ontario, CA,USA

Attestation Statements

AnkerInnovationsLimited To:FederalCommunicationsCommissionDate:2026/04/01 7435OaklandMillsRoad Columbia,MD21046 USA Attestation Section2.911(d)(5)(i)andSection2.911(d)(5)(ii) (KDB986446D01CoveredEquipment) Section2.911(d)(5)(i) AnkerInnovationsLimitedcertifiesthattheequipmentforwhichauthorizationissoughtisnotβ€œcovered” equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903oftheFCC rules. Thesoftwaretobeloadedpriortomarketingoftheequipmentidentifiedbelowisnot"covered" softwaremanufacturedbyanyentityincludingpredecessors,successors,parents,subsidiaries,or affiliatesoranyentitywhichhasrebrandedorrelabeledthesoftwareproducedbytheentity(ies) identifiedonthe"CoveredList"DA24-886andKDB986446D01CoveredEquipmentGuidancesection B(2a). AnkerInnovationsLimitedfurthercertifiesthatnoCybersecurityoranti-virussoftwareproducedor providedbyKasperskyLab,Inc.oranyofitssuccessorsandassignees,includingequipmentwith integratedKasperskyLab,Inc.(oranyofitssuccessorsandassignees)cybersecurityoranti-virus softwareisinstalledintheequipmentbeingcertified. Section2.911(d)(5)(ii) AnkerInnovationsLimitedcertifiesthat,asofthedateofthefilingoftheapplication,the applicantisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofits subsidiariesoraffiliates)asanentityproducingβ€œcovered”equipment. TypeofEquipmentsubjecttoFCCCertification:eufyGlassBreakSensorE10 FCCID:2AOKB-T90G0 Ifyouhaveanyquestions,pleasefeelfreetocontactme ContactPerson:JustinZhou PositionintheCompany:ManagerDate ofSignature:2026-04-01 Signatory (signatureoftheapplicant)

Cover Letter(s)

AnkerInno vati ons Li mi ted Date:2026/ 04/ 01 To : Fed er al Co mmunicati ons Co mmi ssion, Autho rizati on & Evaluation Di vi sion, 7435OaklandMills Road , Co lumbia, MD 21046 ToWhomItMayConcern: TheAnkerInnovationsLimited,theundersigned,herebyauthorizesMrs.WendyZhan fromShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,toact on thebehalf oftheAnkerInnovationsLimitedsolelyinmattersrelatingtotheapplicationforan FCCequipmentauthorizationforFCCID:2AOKB-T90G0includingthesigning of documentsin connectionwiththisApplication.Necessaryactscarriedout ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.onourbehalfoftheAnker InnovationsLimitedinconnectionwiththeApplicationshallhavethesameeffectas actsof theAnkerInnovationsLimited.AnkerInnovationsLimitedalsohereby certifythatno partyto thisapplicationis subjectto a denialof benefits, includingFCCbenefits,pursuantto Section5301of theAnti-DrugAbuseActof 1988,21U.S.C.862. Thankyouforyourattentiontothismatter. YoursSincerely, Signatory: Co ntac t name:Jus ti n Zho u Tel:+86-755-86544807 Email: jus ti n. zho u1@anker-in. com Co mp anyname:AnkerInno vati ons Li mi ted

Cover Letter(s)

AnkerInnovationsLimited Date:2026/04/01 To:FederalCommunicationsCommission,Authorization&EvaluationDivision,7435Oakland MillsRoad,Columbia,MD21046 Re:RequestofConfidentialityforFCCID: 2AOKB-T9G0 ToWhomitmayconcern: Pursuanttosections0.457and0.459ofCommission’sRules(CFR47),andSection552(b)(4) oftheFreedomofInformationAct,AnkerInnovationsLimitedherebyrequestsconfidentialityand treatmentofcertaininformationaccompanyingthisapplication.Thematerialscontaintrade secretsandproprietaryinformationnotcustomarilyreleasedtothepublic.Thepublicdisclosure ofthesemattersmightbeharmfultotheApplicantandprovideunjustifiedbenefitstoits competitors. WearealsoherebyrequestShort-TermConfidentialityfor180daysfromgrantdateasoutlined inPublicNoticeDA04-1705.ThisprovisionwillgiveAnkerInnovationsLimitedtemporary confidentialityofcommerciallysensitiveinformationpriortoproductrelease. TherequestedPermanentandShort-TermConfidentialexhibitsarelistedasfollows: PERMANENTANDSHORT-TERMCONFIDENTIALLIST ExhibitDescription PERMANENT 1BlockDiagram 2OperationalDescription 3Schematics 4BOM SHORT-TERM 5ExternalPhotos 6InternalPhotos 7Test-SetupPhotos 8UserManual TheApplicantunderstandsthatpursuanttoRule0.457,disclosureofthisapplicationandall accompanyingdocumentations,whereapplicable,willnotbemadepublicbeforethedateofthe Grantforthisapplication. Signatory: Contactname:JustinZhou Tel:+86-755-86544807 Email:[email protected] Companyname:AnkerInnovationsLimited

ID Label/Location Info

Glass break NA 2025.04.22 SM V1.0 :   , ,T90G09202401000124 1120001T90G0Glass break NA 7mm 5mm 8*8mm SYNC  !"#$: : & '()*,  +: -.(3567  8.(; 8.( .(3567,<=>?@B。 DEFH8.( I8.(IJKL,MOOPQR。 .( S(>?οΌ‰: S'7=: SNGilroy,3.5ptOZO QR code16 1.15 1.21O I 1.310-F 16 1.410-9 A-Z O I 1.52201919 202020 1.621 01 2 02...... 52 52 1.74 40001β€”FFFF  、 : 、  : οΌ‰ 、  :, 、 : , ,( οΌ‰οΌŒ 、 :, , 、  :  ,   。 、, ,οΌ› SNSN οΌ‰ οΌ‰ οΌ‰ οΌ‰ οΌ‰ οΌ‰ T90G0 9 1 019 01 0001 !"#$%:0001β€”FFFF &:01 52β€” '&19 99β€” ()*+&:0, &:&,NA=1,, ./&:346./&79, -.:T90G0,7,Glass break 8%: eufy Glass Break Sensor E10 Model: T90G0 Input: 3V , CR123A IP20 FCC ID: 2AOKB-T90G0 IC: 23451-T90G0 CAN ICES (B)/NMB (B) Anker Innovations Limited Unit 56,8th Floor, Tower 2, Admiralty Centre,18 Harcourt Road,Hong Kong Made in China SN:XXXXXXXXXXXXXXXX 5mm LH6210003V1.0 5mm 6.7mm 5.6mm

RF Exposure Info

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 9 REPORT No.:SZ26030019S01 RF EXPOSURE EXEMPT REPORT APPLICANT :Anker Innovations Limited PRODUCT NAME :eufy Glass Break Sensor E10 MODEL NAME :T90G0 BRAND NAME :eufy FCC ID : 2AOKB-T90G0 STANDARD(S) : 47 CFR Part 2(2.1093) RECEIPT DATE : 2026-01-30 TEST DATE :2026-03-20 to 2026-03-25 ISSUE DATE :20265-06-08 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL..1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 9 REPORT No.:SZ26030019S01 DIRECTORY 1. Technical Information βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 3 1.1 Applicant and Manufacturer Information βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 3 1.2 Equipment Under Test (EUT) Description βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 3 1.3 Applied Reference Documents βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 4 2. Device Category and RF Exposure Limit βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 5 3. Maximum Average Power Summary βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 6 4. RF Exposure Evaluation βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 7 Annex A Testing Laboratory Information βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 8 Change History Version Date Reason for Change 1.0 2026-06-08 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL..1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 9 REPORT No.:SZ26030019S01 1. Technical Information Note: Provide by applicant. 1.1 Applicant and Manufacturer Information Applicant: Anker Innovations Limited Applicant Address: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong Manufacturer: Anker Innovations Limited Manufacturer Address: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong 1.2 Equipment Under Test (EUT) Description Product Name: eufy Glass Break Sensor E10 Sample No.: 1#, 3# Hardware Version: V2.0 Software Version: V2.2.0.5 Operating Frequency: 920.0MHz, 920.2MHz, 920.4MHz, 920.6MHz, 920.8MHz Channel Number: 5 Antenna Type: Metal Antenna Antenna Gain: -3.14dBi Note 1: The EUT description presented in the report are provided by applicant and/or manufacturer, and the test laboratory is not responsible for the accuracy of the information. For a more detailed description, please refer to Specification or User’s Manual supplied by the applicant and/or manufacturer. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL..1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 9 REPORT No.:SZ26030019S01 1.3 Applied Reference Documents Leading reference documents for testing: Identity Document Title Remark 47 CFR Part 2(2.1093) Radio Frequency Radiation Exposure Assessment: Portable devices / KDB 447498 D01v06 General RF Exposure Guidance / Note 1: Any additions, deviation, or exclusions from the method shall be noted in the β€œRemark". MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL..1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 5 of 9 REPORT No.:SZ26030019S01 2. Device Category and RF Exposure Limit Based on 47 CFR 2.1093, this device belongs to portable device category with General Population/Uncontrolled exposure. Portable Devices: 47 CFR 2.1093(b) For purposes of this section, a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. General Population/Uncontrolled Exposure: 47 CFR 2.1093(d) (2) Limits for General Population/Uncontrolled exposure: 0.08 W/kg as averaged over the whole-body and spatial peak SAR not exceeding 1.6 W/kg as averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the hands, wrists, feet and ankles where the spatial peak SAR shall not exceed 4 W/kg, as averaged over any 10 grams of tissue (defined as a tissue volume in the shape of a cube). General Population/Uncontrolled limits apply when the general public may be exposed, or when persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or do not exercise control over their exposure. Warning labels placed on consumer devices such as cellular telephones will not be sufficient reason to allow these devices to be evaluated subject to limits for occupational/controlled exposure i…

Text truncated - open the document above for the full version.

Test Report

www.leedarson.com ▏Better Life with Better IoT Innovation Rev. 1.0 Antenna Specification Antenna picture Antenna Type Metal Antenna Antenna Peak Gain -3.14dBi Operating Band 860~870 MHz / 915~925 MHz Test laboratory name and Address IoT Antenna Test Laboratory, 3 / A,LEEDARSON LIGHTING CO., LTD. Xingtai Industrial Park, Changtai Economic Development Zone, Zhangzhou, 363900, China Antenna Manufacturer LEEDARSON LIGHTING CO., LTD. Test Date 2025-11-28 Test Conductor Xiu weisong ANT Antenna Information www.leedarson.com ▏Better Life with Better IoT Innovation 1 OTA measurement Test System The SY-16 OTA system and RayZone2800 OTA system are anechoic chambers, which can measures antenna passive data such as antenna efficiency, antenna gain, and 2D&3D pattern. The systems are shown as follow: Figure 1 SY-16 OTA system Figure 2 RayZone2800 OTA system Antenna Information www.leedarson.com ▏Better Life with Better IoT Innovation 2 Equipment List Table 1 Equipment List Used Equipment Manufacturer Model No. Serial No. Last Cal. Due Date β˜’ Network Analyzer Keysight E5071C MY46527808 2025/1/9 2026/1/8 ☐ Network Analyzer Keysight E5071C MY46108051 2025/4/19 2026/4/18 β˜’ Anechoic Chamber Sunyield SY-16 SI1727 2025/4/28 2026/4/27 ☐ Anechoic Chamber General Test System RayZone2800 CT10121244 B5079 2025/5/10 2026/5/9 Test Method Table 2 Test Method Name Antenna Performance Parameter Radiation Efficiency Test Method IEEE Standard Test Procedures for Antennas Standard No. ANSI/IEEE Std 149-2021 Test Software PMS-V2.8.5 β˜’ MaxSign-V1.4.3 ☐ Test Result Efficiency and Gain Table 3 Antenna Efficiency and Gain Frequency (MHz) Gain (dBi) Efficiency (dB) Efficiency (%) 860 -3.81 -5.58 27.65 862 -3.74 -5.53 27.99 864 -3.73 -5.51 28.10 866 -3.67 -5.52 28.06 868 -3.48 -5.53 28.00 870 -3.24 -5.52 28.06 914 -3.35 -6.54 22.19 916 -3.27 -6.58 22.00 918 -3.17 -6.62 21.78 Antenna Information www.leedarson.com ▏Better Life with Better IoT Innovation 3 920 -3.14-6.6821.48 922 -3.21-6.7621.07 924 -3.43-6.8620.63 926 -3.75-6.9520.17 Radiation Pattern Table 4 Product coordinates Product Coordinates Antenna Information www.leedarson.com ▏Better Life with Better IoT Innovation 4 Table 5 3D radiation pattern 3D Radiation Pattern Table 6 Radiation pattern in XY Plane 2D Radiation Pattern ( ΞΈ = 90Β°, XY Plane) Antenna Information www.leedarson.com ▏Better Life with Better IoT Innovation 5 Table 7 Radiation pattern in XZ Plane 2D Radiation Pattern ( Ο† = 0Β°, XZ Plane) Table 8 Radiation pattern in YZ Plane 2D Radiation Pattern ( Ο† = 90Β°, YZ Plane)

Test Report

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 39 REPORT No.:SZ26030019W01 TEST REPORT APPLICANT :Anker Innovations Limited PRODUCT NAME :eufy Glass Break Sensor E10 MODEL NAME :T90G0 BRAND NAME :eufy FCC ID : 2AOKB-T90G0 STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2026-01-30 TEST DATE :2026-03-20 to 2026-03-25 ISSUE DATE :2026-06-08 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 39 REPORT No.:SZ26030019W01 DIRECTORY 1. Technical Information ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 3 1.1. Applicant and Manufacturer Information ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 3 1.2. Equipment Under Test (EUT) Description ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 3 1.3. The Channel Number and Frequency ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 4 1.4. Test Standards and Results ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 5 1.5. Environmental Conditions ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 5 2. 47 CFR Part 15C Requirements ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 6 2.1. Antenna Requirement ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 6 2.2. The Max Transmission Time ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 7 2.3. Bandwidth ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 9 2.4. Conducted Emission ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 12 2.5. Radiated Emission ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 14 Annex A Test Uncertainty ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 35 Annex B Testing Laboratory Information ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 36 Notes ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 39 Change History Version Date Reason for change 1.0 2026-06-08 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 39 REPORT No.:SZ26030019W01 1. Technical Information Note: Provide by applicant. 1.1. Applicant and Manufacturer Information Applicant: Anker Innovations Limited Applicant Address: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong Manufacturer: Anker Innovations Limited Manufacturer Address: Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong 1.2. Equipment Under Test (EUT) Description Product Name: eufy Glass Break Sensor E10 Sample No.: 1#, 3# Hardware Version: V2.0 Software Version: V2.2.0.5 Operating Frequency Range: 920.0MHz, 920.2MHz, 920.4MHz, 920.6MHz, 920.8MHz Channel Number: 5 Type of Transmitter: Activated Automatically Antenna Type: Metal Antenna Antenna Gain: -3.14dBi Accessory Information: Battery Brand Name: N/A Model No.: CR123AH Serial No.: N/A Capacity: 1500mAh Rated Voltage: 3.0V Charge Limit: N/A Manufacturer: EVE Energy Co., Ltd. Note 1: The EUT description presented in the report are provided by applicant and/or manufacturer, and the test laboratory is not responsible for the accuracy of the information. For a more detailed description, please refer to Specification or User’s Manual supplied by the applicant and/or manufacturer. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 39 REPORT No.:SZ26030019W01 1.3. The Channel Number and Frequency Channel Frequency (MHz) 1 920.0 2 920.2 3 920.4 4 920.6 5 920.8 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 5 of 39 REPORT No.:SZ26030019W01 1.4. Test Standards and Results The objective of the report is to perform testing according to 47 CFR Part 15 Subpart C for the EUT FCC ID Certification: No Identity Document Title 1 47 CFR Part 15 Radio Frequency Devices Test detailed items/section required by FCC rules and results are as below: No Section Description Test Date Test Engineer Result Remark 1 15.203 Antenna Requirement N/A N/A PASS / 2 15.231(a)(1) The Max Transmission Time Mar. 25, 2026 Lin Haoyang PASS / 3 15.231(c) 20dB Bandwidth Mar. 25, 2026 Lin Haoyang PASS / 4 15.207 Conducted Emission N/A N/A N/A Note1 / 5 15.231(b) 15.209(a) Radiated Emission Mar. 27, 2026 Zhong Xiangyun PASS / Note 1: Measurements to demonstrate compliance with the conduc…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Justin Zhou
[email protected]Fax: N/A

Technical Contact

Fantasia Trading LLCConnor Zhai
[email protected]

5350 Ontario Mills Pkwy, STE 100, Β· United States

Test Firm

Shenzhen Morlab Communications Technology Co. Ltd.Mr. Su Feng
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231920 MHz - 920.8 MHz-
Confidentiality
Long Term

Other Applications from Anker Innovations Limited

2AOKB-A1664B

Anker MagGo Power Bank (10K,Slim)

Aug 26, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2AOKB-A1665A

Anker Nano Power Bank (5K, MagGo, Slim)

Aug 26, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2AOKB-D1105R

ANKER AeroClip 2

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
2AOKB-D1105L

ANKER AeroClip 2

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
Anker MagGo Power Bank 2 Pro - FCC ID 2AOKB-A110R - Anker Innovations Limited
2AOKB-A110R

Anker MagGo Power Bank 2 Pro

Aug 19, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz