Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
For FAQs and more information, please visit: https://www.anker.com/support 51005001613 V02 A2573 0201 EN LED IndicatorStatus Solid blue for 3 seconds, then offConnected to power Solid blueCharging mobile device Flashing blueMetal or abnormal objects detected Flashing green Overvoltage protection, indicating you need to switch to a 12V 3A DC adapter T • You cannot charge your device wirelessly in these scenarios: O using a case with a magnetic/iron plate; O using a case with a pop socket; O using an ultra-thick (> 5 mm) protective phone case. • Do not place any foreign objects between your device and the wireless charger’s surface, including metal pads on a car mount, credit cards, door keys, coins, metal, or NFC cards, which will make wireless charging fail or cause overheating. • Wireless chargers make charging more convenient than wired chargers, but confined by current wireless technology, their charging speed is slower than that of wired chargers. • High temperatures will reduce charging speed and restrict power, which is a phenomenon common to all wireless chargers. It is recommended that you charge your device in environments with temperatures below 25°C / 77°F. • Both the protective phone case and the position of your device on the wireless charger will affect the charging speed. The farther it is placed from the center of the wireless charger, the slower the charging speed will be. Important Safety Instructions • Avoid dropping. • Do not disassemble. • Do not expose to liquids. • For the safest and fastest charge, use original or certified cables. • This product is suitable for moderate climates only. • The maximum ambient temperature during use of this product must not exceed 40°C. • Open flame sources, such as candles, must not be placed on this product. • Only use a dry cloth or brush to clean this product. FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or relocate the receiving antenna. (2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (4) Consult the dealer or an experienced radio / TV technician for help. Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator & your body. Product Name: PowerWave 10 Stand with 2 USB-A Ports Model: A2573 Anker Innovations Limited Room 1318-19, Hollywood Plaza, 610 Nathan Road, Mongkok, Kowloon, Hong Kong This device complies with RSS-216 of Industry Canada. Operation is subject to the condition that this device does not cause harmful interference. RSS-Gen Issue 5 March 2019 "&" RSS-Gen numéro 5 mars 2019 This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: 0403 (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. RF exposure statement: The equipment complies with IC Radiation exposure limit set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. The following importer is the responsible party (for FCC matters only). Company Name: Fantasia Trading LLC Address: 9155 Archibald Avenue, Suite 202, Rancho Cucamonga, CA, 91730, US Telephone: +1 (909) 484 1530 IC Statement This device complies with RSS-216 of Industry Canada. Operation is subject to the condition that this device does not cause harmful interference. Specifications Input 12V 3A Wireless Output 5W / 7.5W / 10W / 15W USB Output 5V 2.4A (Max) Size 204.6 x 92.0 x 14.8 mm / 8.1 x 3.6 x 0.6 in Weight 185 g / 6.5 oz Declaration of Conformity Hereby, Anker Innovations Limited declares that the product type A2573 is in compliance with Directives 2014/53/EU & 2011/65/EU. The full text of the EU declaration of conformity is available at the following internet address: https://www.anker.com/ Anker Innovations Limited Room 1318-19, Hollywood Plaza, 610 Nathan Road, Mongkok, Kowloon, Hong Kong DE LED-AnzeigeStatus Leuchtet 3 Sekunden lang blau, dann aus An Stromversorgung angeschlossen Leuchtet blauGerät lädt Blinkt blauMetall- oder abnormale Gegenstände erkannt Blinkt grün Überspannungsschutz, zeigt an, dass Sie auf einen 12 V 3 A Gleichstromadapter wechseln müssen T • Sie können Ihr Gerät in den Folgenden Situationen …
Text truncated - open the document above for the full version.
C5266091_X8_Ed.1 1/1 Letter of Authorization Anker Innovations Limited Company: Anker Innovations Limited Address: Room 1318-19, Hollywood Plaza 610 Nathan Road, Mongkok, Kowloon, Hong Kong Product Name: PowerWave 10 Stand with 2 USB-A Ports Model Number: A2573 FCC Identifier: 2AOKBA2573 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: louis Qi Date: 5/8/2020 Title: Manager Signature of applicant:
C5266091_X10_Ed.1 1/1 Anker Innovations Limited Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 5/8/2020 Subject: Request for Confidentiality FCC ID: 2AOKBA2573 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality ID Label/Location No No Attestation Statement No No External Photos No Block Diagram Schematics Test Report No No Test Setup Photos No User’s Manual Internal Photos Parts List / Tune Up RF Exposure Info Operational Description Cover Letter(s) No No SDR Software / Security Info No Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: louis Qi Date: 5/8/2020 Title: Manager
1 - Page 1 of 4 - Report No.: MTi20032509-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China APPENDIX 1: EUT PHOTO Photo 1 (For model A2573) Photo 2 1 - Page 2 of 4 - Report No.: MTi20032509-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 3 Photo 4 1 - Page 3 of 4 - Report No.: MTi20032509-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 5 Photo 6 1 - Page 4 of 4 - Report No.: MTi20032509-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 7 ----END OF REPORT----
Size: 40*30mm
1 - Page 1 of 4 - Report No.: MTi20032509-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China APPENDIX 1: EUT PHOTO Photo 1 (For model A2573) Photo 2 1 - Page 2 of 4 - Report No.: MTi20032509-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 3 Photo 4 1 - Page 3 of 4 - Report No.: MTi20032509-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 5 Photo 6 Wireless charging antenna 1 - Page 4 of 4 - Report No.: MTi20032509-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 7 ----END OF REPORT----
This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China EXPOSURE REPORT FCC ID: 2AOKBA2573 Date of issue: Apr. 29, 2020 Report Number: MTi20032509-4E2 Sample Description: PowerWave 10 Stand with 2 USB-A Ports Mo d e l( s ) : A2573 Applicant: Anker Innovations Limited Address: Room 1318-19, Hollywood Plaza 610 Nathan Road, Mongkok, Kowloon, Hong Kong Date of Test: Apr. 16, 2020 – Apr. 24, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 9 - Report No.: MTi20032509-4E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Test Result Certification Applicant’s name: Anker Innovations Limited Address: Room 1318-19, Hollywood Plaza 610 Nathan Road, Mongkok, Kowloon, Hong Kong Manufacture's name: Anker Innovations Limited Address: Room 1318-19, Hollywood Plaza 610 Nathan Road, Mongkok, Kowloon, Hong Kong Factory's name: SuiChuan CE Link Limited Address: SuiChuan County Industrial Park East Zone, Ji'an City, Jiangxi Province, China Factory's name: CE Link Viet Nam Co Ltd Address: Lo FJ - 25, Song Khe-Noi Hoang Industrial Zone, Noi Hoang Village, Yen Dung Town, Bac Giang Province, Viet Nam, 237510 Product name: PowerWave 10 Stand with 2 USB-A Ports Trademark: ANKER Model name: A2573 Standard: FCC CFR 47 PART 1 , 1.1310 RF Exposure Procedures: KDB 680106 D01 RF Exposure Wireless Charging App v03 This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that the equipment under test (EUT) compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by: Demi Mu Apr. 24, 2020 Reviewed by: Leo Su Apr. 29, 2020 Approved by: Tom Xue Apr. 29, 2020 - Page 3 of 9 - Report No.: MTi20032509-4E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 1 General Information 1.1 Description of EUT Product name: PowerWave 10 Stand with 2 USB-A Ports Brand name: ANKER Model name: A2573 Series model: N/A Deference in serial model: N/A Operation frequency: 115–205 kHz Operational mode: Wireless charging Modulation type: ASK Antenna type: Coil Antenna Power source: DC 12V from adapter AC 120V/60Hz Battery: N/A Adapter information: Model: A2612 Input: 100-240V~ 50/60Hz 1.2A Output: 12.0V 3.0A 1.2 Ancillary equipment list Equipment Model S/N Manufacturer / / / / / / / / 1.3 Measurement uncertainty Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y) Radiated emission(150kHz~30MHz) ± 2.5 dB Radiated emission(30MHz~1GHz) ± 4.2 dB Radiated emission (above 1GHz) ± 4.3 dB Temperature ±1 degree Humidity ± 5 % - Page 4 of 9 - Report No.: MTi20032509-4E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 2 Testing site Test Site Shenzhen Microtest Co., Ltd Test Site Location No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China FCC Registration No.: 448573 - Page 5 of 9 - Report No.: MTi20032509-4E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 3 List of test equipment Equipment No. Equipment Name Manufacturer Model Serial No. Calibration date Due date MTI-E068 Broadband Field Meter Narda Safety Test Solutions GmbH NBM- 520 D-1699 2019/07/13 2020/07/12 MTI-E069 Probe E-Field Narda Safety Test Solutions EF0691 H-0571 2019/07/13 2020/07/12 - Page 6 of 9 - Report No.: MTi20032509-4E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 4 Test Results 4.4 Maximum permissible exposure 4.4.1 Limit Frequency range(MHz) Electric field strength(V/m) Magnetic field strength(A/m) Power density(mW/cm2) Averaging time(minutes) (A) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *100 6 3.0-30 1842/f 4.89/f *900/f 2 6 30-300 61.4 0.163 1.0 6 6 300-1500 f/300 6 1500-100000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *100 30 1.34-30 824/f 2.19/f *180/f 2 30 30-300 27.5 0.073 0.2 30 300-1500 f/1500 30 1500-100000 1 30 f = frequency in MHz * = Plane-wave equivalent power density 4.4.2 Test Procedures E and H-field measurements should be made with the center of the probe at a distance of 15 cm surrounding the device and 20 cm above the top surface of the primary/client pair. These measurements should be repeated for three different client battery levels, 1%, 50%, and 99%. Record the test results. KDB 680106 D01 RF Exposure Wireless Charging App v03: (1) Power transfer frequency is less than 1MHz. (2) Output power from each primary coil is less than or equal to 15 watts. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. (4) Client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not c…
Text truncated - open the document above for the full version.
This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Test Report FCC ID: 2AOKBA2573 Date of issue: Apr. 29, 2020 Report number: MTi20032509-4E1 Sample description: PowerWave 10 Stand with 2 USB-A Ports Mo d e l( s ) : A2573 Applicant: Anker Innovations Limited Address: Room 1318-19, Hollywood Plaza 610 Nathan Road, Mongkok, Kowloon, Hong Kong Date of test: Apr. 16, 2020 – Apr. 24, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 25 - Report No.: MTi20032509-4E1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Table of Contents 1 GENERAL INFORMATION ................................................................................................................................... 4 1.1 FEATURE OF EQUIPMENT UNDER TEST (EUT) ................................................................................................................... 4 1.2 TEST MODE .............................................................................................................................................................. 4 1.3 EUT TEST SETUP........................................................................................................................................................ 5 1.4 ANCILLARY EQUIPMENT .............................................................................................................................................. 5 2 SUMMARY OF TEST RESULT ............................................................................................................................... 6 2.1 OPERATION CHANNEL LIST ........................................................................................................................................... 6 2.2 TEST CHANNEL .......................................................................................................................................................... 6 3 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 7 3.1 TEST LABORATORY ..................................................................................................................................................... 7 3.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 7 3.3 MEASUREMENT UNCERTAINTY ...................................................................................................................................... 7 3.4 TEST SOFTWARE ........................................................................................................................................................ 7 4 LIST OF TEST EQUIPMENT .................................................................................................................................. 8 5 TEST RESULTS ..................................................................................................................................................... 9 5.1 ANTENNA REQUIREMENT ............................................................................................................................................ 9 5.1.1 Standard requirement ................................................................................................................................. 9 5.1.2 EUT Antenna ............................................................................................................................................... 9 5.2 CONDUCTED EMISSION ............................................................................................................................................. 10 5.2.1 Limits ......................................................................................................................................................... 10 5.2.2 Test Procedures ......................................................................................................................................... 10 5.2.3 Test Setup .................................................................................................................................................. 10 5.2.4 Test Result ................................................................................................................................................. 10 5.3 RADIATED EMISSION ................................................................................................................................................. 15 5.3.1 Limits ......................................................................................................................................................... 15 5.3.2 Test Procedures ......................................................................................................................................... 16 5.3.3 Test Setup .................................................................................................................................................. 17 5.3.4 Test Result ................................................................................................................................................. 17 5.4 OCCUPIED BANDWIDTH............................................................................................................................................. 22 5.4.1 Test method ......................................................................................................................…
Text truncated - open the document above for the full version.
Model: A2573 Radiated emission Conducted emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.115 MHz - 0.205 MHz | - |
Anker SOLIX S5000 Portable Power Station
Equipment Class
DTS - Digital Transmission SystemAnker MagGo Power Bank (10K,Slim)
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzAnker Nano Power Bank (5K, MagGo, Slim)
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzANKER AeroClip 2
Equipment Class
DTS - Digital Transmission SystemANKER AeroClip 2
Equipment Class
DTS - Digital Transmission System