FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SHENZHEN TUGAO INTELLIGENT CO.,LTD/
  3. 2AOKUTABLET

2AOKUTABLETTABLET

SHENZHEN TUGAO INTELLIGENT CO.,LTD
TABLET - FCC ID 2AOKUTABLET - SHENZHEN TUGAO INTELLIGENT CO.,LTD
Click to zoom

Application Details

Equipment Class
JBC - Part 15 Class B Computing Device/Personal Computer
Date of Grant
Nov 29, 2022
Application Purpose
Original Equipment
Date of Application
Nov 29, 2022
Equipment Note
TABLET
Company
SHENZHEN TUGAO INTELLIGENT CO.,LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

SHENZHEN TUGAO INTELLIGENT CO., LTD. Family models difference declaration Tablet Model: GQ3100, P2201T, P2202T, TAB R6 Pro Max, TAB R6 Max, TAB R6 Plus, TAB R5 Pro, TAB R5 Pro Max, TAB R5 Max, TAB R5 Plus, Strong Tablet P15000 PRO Trade mark: HOTWAV, iHunt Difference declaration: All models are the same circuit and RF module, except the model name. Regards, Signature Lea Yee / Manager Date/City: 2022-11-16/Shenzhen Phone: 075527318965 Fax: 0755 27318965 E-mail: [email protected]

Cover Letter(s)

SHENZHEN TUGAO INTELLIGENT CO.,LTD Long Term Confidentiality Request Letter (2022-11-15) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR Product: TABLET Model No.: TAB R6 Pro, P2201T, P2202T, TAB R6 Pro Max, TAB R6 Max, TAB R6 Plus, TAB R5 Pro, TAB R5 Pro Max, TAB R5 Max, TAB R5 Plus, Strong Tablet P15000 PRO FCC ID: 2AOKUTABLET To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the  Schematic Diagram  Block Diagram  Part List / BOM List / PCB Layout  Operational Description  Tune-up Procedure  FCC Software Security Requirements for UNII devices Required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Please contact me if there is any information you may need. Sincerely, Lea Yee / Manager Date/City: 2022-11-15/Shenzhen Phone: 075527318965 Fax: 0755 27318965 E-mail: [email protected]

Cover Letter(s)

SHENZHEN TUGAO INTELLIGENT CO.,LTD Short Term Confidentiality Request Letter (2022-11-15) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Short Term Confidentiality Request For Product: TABLET Model No.: TAB R6 Pro, P2201T, P2202T, TAB R6 Pro Max, TAB R6 Max, TAB R6 Plus, TAB R5 Pro, TAB R5 Pro Max, TAB R5 Max, TAB R5 Plus, Strong Tablet P15000 PRO FCC ID: 2AOKUTABLET To Whom It May Concern: In accordance with sections 0.457 and 0.459 of CFR 47, < SHENZHEN TUGAO INTELLIGENT CO.,LTD >. requests short-term Confidentiality of following sections of this application for a period of 180 days after grant is issued. Test setup photos External photos Internal photos User’s manual These documents contain detailed system and equipment descriptions and related information about the product, which < SHENZHEN TUGAO INTELLIGENT CO.,LTD > considers to be proprietary, confidential, and a custom design and otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, < SHENZHEN TUGAO INTELLIGENT CO.,LTD > feels that this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Lea Yee / Manager Date/City: 2022-11-15/Shenzhen Phone: 075527318965 Fax: 0755 27318965 E-mail: [email protected]

Cover Letter(s)

SHENZHEN TUGAO INTELLIGENT CO.,LTD Agent Authorization Letter (2022-11-16) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park Sanwei, Xixiang, Bao'an District, Shenzhen, Guangdong, China Alex.li [email protected] to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Lea Yee / Manager Date/City: 2022-11-16/Shenzhen Phone: 075527318965 Fax: 0755 27318965 E-mail: [email protected]

External Photos

Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6 Photo 7 Photo 8 Photo 9 Photo 10

Internal Photos

Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6 Photo 7 Photo 8 Photo 9 Photo 10 Photo 11 Photo 12 Photo 13 Photo 14 BT/WIFI/GPS ANT GSM/WCDMA/LTE ANT Photo 15 Photo 16 LTE Div NFC ANT Photo 17

Test Report

Report No.: STR220907003007E Version.1.2 Page 1 of 19 FCC Test Report FCC ID: 2AOKUTABLET Product: TABLET Trade Mark: HOTWAV, iHunt Model Number: TAB R6 Pro Family Model: P2201T, P2202T, TAB R6 Pro Max, TAB R6 Max, TAB R6 Plus, TAB R5 Pro, TAB R5 Pro Max, TAB R5 Max, TAB R5 Plus, Strong Tablet P15000 PRO Report No.: STR220907003007E Prepared for SHENZHEN TUGAO INTELLIGENT CO.,LTD 8th Floor, Bldg A, Jinggang Science&Technology Park, Fuyong, Bao'an District, Shenzhen, China Prepared by Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street Bao’an District, Shenzhen P.R. China Tel. 400-800-6106, 0755-2320 0050, 0755-2320 0090 Website:http://www.ntek.org.cn Report No.: STR220907003007E Version.1.2 Page 2 of 19 TEST RESULT CERTIFICATION Applicant’s name.................. : SHENZHEN TUGAO INTELLIGENT CO.,LTD Address .................................. : 8th Floor, Bldg A, Jinggang Science&Technology Park, Fuyong, Bao'an District, Shenzhen, China Manufacturer's Name ........... : SHENZHEN TUGAO INTELLIGENT CO.,LTD Address .................................. : 8th Floor, Bldg A, Jinggang Science&Technology Park, Fuyong, Bao'an District, Shenzhen, China Product description Product name ......................... : TABLET Model and/or type reference . : TAB R6 Pro Family Model .......................... : P2201T, P2202T, TAB R6 Pro Max, TAB R6 Max, TAB R6 Plus, TAB R5 Pro, TAB R5 Pro Max, TAB R5 Max, TAB R5 Plus, Strong Tablet P15000 PRO Standards ............................. : FCC Part15B ANSI C63.4:2014 This device described above has been tested by NTEK, and the test results show that the equipment under test (EUT) is in compliance with Part 15 of FCC Rules. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of NTEK, this document may be altered or revised by NTEK, personnel only, and shall be noted in the revision of the document. Test Sample Number................: T220907001R001 Date of Test ........................................... : Date (s) of performance of tests ............. : Sep 09, 2022 ~ Oct 31, 2022 Date of Issue .......................................... : Oct 31, 2022 Test Result .............................................. : Pass Testing Engineer : (Mary Hu) Authorized Signatory : (Alex Li) Report No.: STR220907003007E Version.1.2 Page 3 of 19 Table of Contents Page 1 . TEST SUMMARY 4 1.1 TEST FACILITY 5 1.2 MEASUREMENT UNCERTAINTY 5 2 . GENERAL INFORMATION 6 2.1 GENERAL DESCRIPTION OF EUT 6 2.2 DESCRIPTION OF TEST SETUP 8 2.3 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL 9 2.4 MEASUREMENT INSTRUMENTS LIST 10 3 . EMC EMISSION TEST 11 3.1 CONDUCTED EMISSION MEASUREMENT 11 3.1.1 POWER LINE CONDUCTED EMISSION 11 3.1.2 TEST PROCEDURE 12 3.1.3 TEST SETUP 12 3.1.4 EUT OPERATING CONDITIONS 12 3.1.5 TEST RESULTS 13 3.2 RADIATED EMISSION MEASUREMENT 15 3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT 15 3.2.2 TEST PROCEDURE 15 3.2.3 TEST SETUP 16 3.2.4 TEST RESULTS 17 3.2.5 TEST RESULTS(1000~18000MHz) 19 Report No.: STR220907003007E Version.1.2 Page 4 of 19 1. TEST SUMMARY Test procedures according to the technical standards: EMC Emission Standard Test Item Limit Judgment Remark FCC Part15B ANSI C63.4: 2014 Conducted Emission Class B PASS Radiated Emission Class B PASS NOTE: (1) ’N/A’ denotes test is not applicable in this Test Report (2) For client’s request and manual description, the test will not be executed. Report No.: STR220907003007E Version.1.2 Page 5 of 19 1.1 TEST FACILITY Shenzhen NTEK Testing Technology Co., Ltd Add. : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District, Shenzhen 518126 P.R. China. IC-Registration The Certificate Registration Number is 9270A. CAB identifier:CN0074 FCC- Accredited Test Firm Registration Number: 463705. Designation Number: CN1184 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. A. Conducted Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE NTEKC01 ANSI 150 KHz ~ 30MHz ±2.80dB B. Radiated Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE NTEKA01 ANSI 30MHz~1000MHz ±2.64dB 1GHz~6GHz ±2.40dB 6GHz~26.5GHz ±2.52dB Report No.: STR220907003007E Version.1.2 Page 6 of 19 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Equipment TABLET Trade Mark HOTWAV, iHunt Model Name TAB R6 Pro Family Model P2201T, P2202T, TAB R6 Pro Max, TAB R6 Max, TAB R6 Plus, TAB R5 Pro, TAB R5 Pro Max, TAB R5 Max, TAB R5 Plus, Strong Tablet P15000 PRO Model Difference All models are the same circuit and RF module, except the model name. Product Description Connecting I/O port: Micro USB, Earphone Operation Frequency: 5.825GHz Based on the application, features, or specification exhibited in User's Manual, the EUT is considered as an ITE/Computing Device. More details of EUT technical specification, please refer to the User's Manual. Adapter Model: QA-0200CA03 Input: 100-240V~50/60Hz 0.5A Output: USB-C:5.0V3.0A or 9.0V2.22A or 12.0V1.67A (20.0W) Battery DC 3.85V, 15600mAh, 60.06Wh Power supply DC 3.85V from battery or DC 5V from Adapter. HW Version TP718_MAIN_PCB_V1.1 SW Version HOTWAV_TAB R6 Pro_V3.0_20221026 Report No.: STR220907003007E Version.1.2 Page 7 of 19 2.1.1 DESCRIPTION OF TEST MODES To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Pretest Mode Description Model 1 USB Data Transmission Model 2 TF card Playing Model 3 REC Model 4 FM Model 5 …

Text truncated - open the document above for the full version.

Test Report

Test Report issued under the responsibility of: TEST REPORT EN 62133-2: 2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications – Part 2: Lithium systems Report Number. ................................ : RSZBHST220916850 Date of issue ..................................... : 2022-09-26 Total number of pages .................... : 25 Pages Name of Testing Laboratory preparing the Report ....................... : Shenzhen Beihang Testing Co., Ltd. Room 202, 2/F, Building F, HaoWei Industrial Park, QingSong West Road, PingShan District, Shenzhen, Guangdong, China Applicant’s name ............................. : Shenzhen Tugao Intelligent Co., Ltd. Address ............................................. : NO.801,802,1001,1002,BldgA,Jingang Science&Technology Park, Fuhai Street, Qiaotou Coummunity, Baoan District, Shenzhen, China 518103 Manufacturer .................................... : Shenzhenshi jiuliyuan electronic technology co., LTD 201, Jiuli Yuan Factory, Building A, No. 470, Pingshan Jinbi Road, Biling Community, Biling Street, Pingshan District, Shenzhen Address ............................................. : Factory ............................................. : Address ............................................. : Shenzhenshi jiuliyuan electronic technology co., LTD 201, Jiuli Yuan Factory, Building A, No. 470, Pingshan Jinbi Road, Biling Community, Biling Street, Pingshan District, Shenzhen Test item description ....................... : Rechargeable Li-ion polymer Battery Model/Type reference ...................... : P2202T Trade Mark ........................................ : N/A Ratings .............................................. : 3.85Vd.c, 15600mAh Standard ........................................... : EN 62133-2: 2017 Test procedure ................................. : Test Report Non-standard test method .............. : N/A General disclaimer: The test results presented in this report relate only to the object tested. Page 2 of 25 Report No. RSZBHST220916850 TRF No. IEC62133_2A Project No: ST220916850 Rev.: 4.0 Page: 2 of 25 Phone : +86 755 8650 3482 Fax : +86 755 8650 3182 Website: http://www.hc-stc.net Check: [email protected] Shenzhen Beihang Testing Co., Ltd. Room 202, 2/F, Building F, HaoWei Industrial Park, QingSong West Road, PingShan District, Shenzhen, Guangdong, China . Responsible Testing Laboratory (as applicable), testing procedure and testing location(s): Testing Laboratory: Shenzhen Beihang Testing Co., Ltd. Testing location/ address ............................. : Room 202, 2/F, Building F, HaoWei Industrial Park, QingSong West Road, PingShan District, Shenzhen, Guangdong, China Tested by (name, function, signature) ........ : Romy. Luo Approved by (name, function, signature) ... : Arvin. Shang Summary of testing: The sample(s) tested complies with the requirements of EN 62133-2:2017 When determining the test conclusion, the Measurement Uncertainty of test has been considered. Tests performed (name of test and test clause): 5.2 Insulation resistance 7.2.1 Continuous charging at constant voltage (cells) 7.2.2 Case stress at high ambient temperature (battery) 7.3.1 External short circuit (cell) 7.3.2 External short circuit (battery) 7.3.3 Free fall 7.3.4 Thermal abuse (cells) 7.3.5 Crush (cells) 7.3.6 Over-charging of battery 7.3.7 Forced discharge (cells) 7.3.8 Mechanical tests (batteries) 7.3.9 Design evaluation – Forced internal short- circuit (cells) Testing location: Shenzhen Beihang Testing Co., Ltd. Room 202, 2/F, Building F, HaoWei Industrial Park, QingSong West Road, PingShan District, Shenzhen, Guangdong, China Summary of compliance with National Differences (List of countries addressed): Group differences for CENELEC countries are considered. The product fulfils the requirements of IEC 62133-2: 2017(Edition1.0) and EN 62133-2:2017. Page 3 of 25 Report No. RSZBHST220916850 TRF No. IEC62133_2A Project No: ST220916850 Rev.: 4.0 Page: 3 of 25 Phone : +86 755 8650 3482 Fax : +86 755 8650 3182 Website: http://www.hc-stc.net Check: [email protected] Shenzhen Beihang Testing Co., Ltd. Room 202, 2/F, Building F, HaoWei Industrial Park, QingSong West Road, PingShan District, Shenzhen, Guangdong, China . Copy of marking plate: The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks. Remark: ―YYYYMMDD‖ represents the date of manufacture, ―YYYY‖ represents year of manufacture, ―MM‖ represents the month of manufacture, ―DD‖ represents the date of manufacture. Rechargeable Li-ion polymer Battery + Model:P2202T 1ICP5/63/91-3 3.85V 15600mAh - YYYYMMDD Shenzhenshi jiuliyuan electronic technology co., LTD Page 4 of 25 Report No. RSZBHST220916850 TRF No. IEC62133_2A Project No: ST220916850 Rev.: 4.0 Page: 4 of 25 Phone : +86 755 8650 3482 Fax : +86 755 8650 3182 Website: http://www.hc-stc.net Check: [email protected] Shenzhen Beihang Testing Co., Ltd. Room 202, 2/F, Building F, HaoWei Industrial Park, QingSong West Road, PingShan District, Shenzhen, Guangdong, China . Test item particulars................................................... : -- Classification of installation and use ....................... : Battery for special end products Recommend charging method declared by the manufacturer ............................................................... : Charging the battery with1040mA constant current until 4.4V, then constant voltage until charge current reduces to 104mA at ambient 20°C±5°C Discharge current (0,2 It A) ....................................... : 1040mA Specified final voltage ................................................ : 3.0V Upper limit charging voltage per cell ....................... : 4.4V Maximum charging current ....................................... : 10920mA Charging temperature upper limit ........…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Measurement Photos AC Conducted Measurement Photos

Contact Information

Applicant

Lea Yee
[email protected]075527318965Fax: 075527318965

Technical Contact

Shenzhen NTEK Testing Technology Co., Ltd.Alex Li
[email protected]+86-755-6115-9384

1/F, Building E, Fenda Science Park Sanwei, · Shenzhen, Guangdong · China

Test Firm

Shenzhen NTEK Testing Technology Co., Ltd.Alex Li
[email protected]+86-755-6115-9384

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from SHENZHEN TUGAO INTELLIGENT CO.,LTD

2AOKU-A-PROMAX

Smartphone

Jan 27, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AOKUHYPER7PRO

Smartphone

Jul 08, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AOKUW11

Smartphone

Apr 14, 2024

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
2AOKUT7

Smartphone

Mar 20, 2024

Equipment Class

DTS - Digital Transmission System
2AOKUTABLETR7

Tablet

Mar 18, 2024

Equipment Class

DTS - Digital Transmission System