FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Vaultek Safe, Inc./
  3. 2AONI-DS5I-8762C460

2AONI-DS5I-8762C460Smart Station

Vaultek Safe, Inc.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 04, 2024
Application Purpose
Original Equipment
Date of Application
Jul 04, 2024
Equipment Note
Smart Station
Frequency Range
2402.00000000 - 2480.00000000
Company
Vaultek Safe, Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

โ†—
โ†—

Cover Letter(s)

โ†—
โ†—
โ†—
โ†—

ID Label/Location Info

โ†—

RF Exposure Info

Test Report

โ†—
โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

ID Label/Location Info

1ใ€ Label 2ใ€ Label location(at the bottom) Model name:DS5i-BK, DS5i-TG, DS5i-WT, DS5i-SA, DS5i-SB, DS5i-SD, DS5i-SR, DS5i-CN, DS5i-DG FCC ID:2AONI-DS5I-8762C460

Test Report

NOTE:ThisdocumentisissuedbyShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,thetestreportshallnotbereproducedexceptin fullwithoutpriorwrittenpermissionofthecompany.Thetestresultsapplyonlytotheparticularsample(s)testedandtothespecifictestscarried outwhichisavailableonrequestforvalidationandinformationconfirmedatourwebsite. MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page1of 10 REPORTNo.๏ผšSZ24050279E10 TESTREPORT APPLICANT:VaultekSafe,Inc. PRODUCTNAME:SmartStation MODELNAME: DS5i-BK,DS5i-TG,DS5i-WT,DS5i-SA,DS5i-SB, DS5i-SD,DS5i-SR,DS5i-CN,DS5i-DG TRADENAME:Vaultek BRANDNAME:Vaultek STANDARD(S):IEEEStd149-2021 RECEIPTDATE:2024-06-03 TESTDATE:2024-06-05 ISSUEDATE:2024-07-02 Editedby: MaoRujie(Rapporteur) Approvedby: ChiShide(Supervisor) MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page2of10 REPORTNo.๏ผšSZ24050279E10 DIRECTORY 1.TechnicalInformation ........................................................................................................3 1.1.ApplicantandManufacturerInformation ....................................................................3 1.2.EquipmentUnderTest(EUT)Description...................................................................3 2.TestResults........................................................................................................................4 2.1.AppliedReferenceDocuments.....................................................................................4 2.2.TestConditions...............................................................................................................4 2.3.MeasurementUncertainty.............................................................................................4 2.4.TestResultslists.............................................................................................................5 AnnexATestSetupPhotos..................................................................................................6 AnnexBFigures .....................................................................................................................7 1.2DRadiationPattern .........................................................................................................7 2.3DRadiationPattern .........................................................................................................8 AnnexCGeneralInformation .............................................................................................10 1.1IdentificationoftheResponsibleTestingLaboratory ..............................................10 1.2IdentificationoftheResponsibleTestingLocation..................................................10 1.3TestEquipmentsUtilized..............................................................................................10 1.4TestSoftwareUtilized....................................................................................................10 AnnexDEUTPhotos ChangeHistory VersionDateReasonforchange 1.02024-07-02Firstedition MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page3of10 REPORTNo.๏ผšSZ24050279E10 1.TechnicalInformation Note:Providebyapplicant. 1.1.ApplicantandManufacturerInformation Applicant: VaultekSafe,Inc. ApplicantAddress: 624DouglasAve.,Suite1412,AltamonteSprings,FL32714 Manufacturer:JeritechElectronics,Ltd. ManufacturerAddress: GuannanyongIndustrialEstate,ShiqiTown,Panyu,GuangZhou, China 1.2.EquipmentUnderTest(EUT)Description WirelessTypeBluetooth Frequency2400MHz-2500MHz ProductHWVersion1.2.0 ProductSWVersion1.0.0 IMEIN/A SampleNo.5# Note: Hereby,we,VaulteksafeInc.,declarethatformodelnumber: DS5i-BK,DS5i-TG,DS5i-WT,DS5i-SA,DS5i-SB,DS5i-SD,DS5i-SR,DS5i-CN,DS5i-DG havethesamehardwareandsoftware,onlydifferentformodelnumberandcolors,allRF parametersremainthesame.ThemainmeasuringmodelisDS5i-BK. MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page4of10 REPORTNo.๏ผšSZ24050279E10 Dimensions: 2. TestResults 2.1.AppliedReferenceDocuments Leadingreferencedocumentsfortesting: No.IdentityDocumentTitle 1IEEEStd149-2021 IEEERecommendedPracticeforAntenna Measurements 2.2.TestConditions TestEnvironmentConditions๏ผš RelativeHumidity(%):25-75 Temperature(ยฐC):10-30 2.3.MeasurementUncertainty Theuncertaintyiscalculatedusingthemethodssuggestedintheโ€œGuidetotheExpressionof UncertaintyinMeasurementโ€(GUM)publishedbyISO.Whenthetestresultisacriticalvalue,we willusethemeasurementuncertaintygivethejudgmentresultbasedonthe95%Confidence intervals. MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page5of10 REPORTNo.๏ผšSZ24050279E10 2.4.TestResultslists 2.4.1.Gain Frequency (MHz) Gain(dBi) 24001.84 24101.84 24201.85 24301.94 24402.03 24502.04 24601.82 24701.50 24801.37 24901.21 25001.22 MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page6of10 REPORTNo.๏ผšSZ24050279E10 AnnexATestSetupPhotos MORLAB ShenzhenMorlabโ€ฆ

Text truncated - open the document above for the full version.

Test Report

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 73 REPORT No.๏ผšSZ24050279W01 TEST REPORT APPLICANT : Vaultek Safe, Inc. PRODUCT NAME : Smart Station MODEL NAME : DS5i-BK, DS5i-TG, DS5i-WT, DS5i-SA, DS5i-SB, DS5i-SD, DS5i-SR, DS5i-CN, DS5i-DG BRAND NAME : Vaultek FCC ID :2AONI-DS5I-8762C460 STANDARD(S) :47 CFR Part 15 Subpart C RECEIPT DATE : 2024-05-30 TEST DATE : 2024-06-07 to 2024-06-19 ISSUE DATE : 2024-07-04 Edited by: Peng Mi (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 73 REPORT No.๏ผšSZ24050279W01 DIRECTORY 1. Summary of Test Result ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 1.1. Testing Applied Standards ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 1.2. Test Equipment List ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 1.3. Measurement Uncertainty ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 1.4. Testing Laboratory ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 2. General Description ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 2.1. Information of Applicant and Manufacturer ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 2.2. Information of EUT ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 2.3. Channel List of EUT ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 11 2.4. Test Configuration of EUT ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 12 2.5. Test Conditions ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 12 2.6. Test Setup Layout Diagram ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 12 3. Test Results ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 15 3.1. Antenna Requirement ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 15 3.2. Duty Cycle of Test Signal ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 16 3.3. Maximum Peak Conducted Output Power ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 17 3.4. Maximum Average Conducted Output Power ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 18 3.5. 6 dB Bandwidth ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 19 3.6. Conducted Spurious Emissions and Band Edge ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 20 3.7. Power Spectral Density ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 21 3.8. Conducted Emission ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 22 3.9. Restricted Frequency Bands ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 23 3.10. Radiated Emission ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 24 Annex A Test Data and Result ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 26 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 73 REPORT No.๏ผšSZ24050279W01 Change History Version Date Reason for change 1.0 2024-07-04 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 73 REPORT No.๏ผšSZ24050279W01 1. Summary of Test Result No. Section Description Test Date Test Engineer Result Method Determination /Remark 1 15.203 Antenna Requirement N/A N/A PASS No deviation 2 N/A Duty Cycle of Test Signal Jun. 17, 2024 Su Xiaoxian PASS No deviation 3 15.247(b) Maximum Peak Conducted Output Power Jun. 17, 2024 Su Xiaoxian PASS No deviation 4 15.247(b) Maximum Average Conducted Output Power Jun. 17, 2024 Su Xiaoxian PASS No deviation 5 15.247(a) Bandwidth Jun. 17, 2024 Su Xiaoxian PASS No deviation 6 15.247(d) Conducted Spurious Emission and Band Edge Jun. 17, 2024 Su Xiaoxian PASS No deviation 7 15.247(e) Power Spectral Density Jun. 17, 2024 Su Xiaoxian PASS No deviation 8 15.207 Conducted Emission Jun. 07, 2024 Wang Deyong PASS No deviation 9 15.247(d) Restricted Frequency Bands Jun. 09, 2024 Su Zhan PASS No deviation 10 15.209, 15.247(d) Radiated Emission Jun. 09, 2024 Su Zhan PASS No deviation Note 1: The tests were performed according to the method of measurements prescribed in ANSI C63.10-2013 and KDB 558074 D01 v05r02. Note 2: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 3: When the test result is a critical value, we will use the measurement uncโ€ฆ

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jervis Zhan
[email protected]020-39183187Fax: 020-84508113

Test Firm

Shenzhen Morlab Communications Technology Co. Ltd.Mr. Su Feng
[email protected]+86 755 36698566

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz5.38 mW
Confidentiality
Long Term
Grant Notes
Output power is maximum peak conducted.

Other Applications from Vaultek Safe, Inc.

Smart Key with BT - FCC ID 2AONI-VSKN20-8752C - Vaultek Safe, Inc.
2AONI-VSKN20-8752C

Smart Key with BT

Jul 29, 2021

Equipment Class

DTS - Digital Transmission System
Lifepod Humidor (Portable lockbox with Bluetooth) - FCC ID 2AONI-VLH-8762C5616 - Vaultek Safe, Inc.
2AONI-VLH-8762C5616

Lifepod Humidor (Portable lockbox with Bluetooth)

Jun 18, 2020

Equipment Class

DTS - Digital Transmission System
Nano Touch ( Fingerprint Switch ) - FCC ID 2AONI-VSK-NT5063501 - Vaultek Safe, Inc.
2AONI-VSK-NT5063501

Nano Touch ( Fingerprint Switch )

Mar 15, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter