Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Guangdong Welland Technology Co., Ltd. 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – EquipmentType Company name: Guangdong Welland Technology Co., Ltd. Address: No. 7 Minke East Road, Shiqi Sub-district, Zhongshan, China Product Name: Smart Scale FCC ID: 2AP3Q- FG2415WB Model(s): FG2415WB 2.911(d)(5)(i) EquipmentType We, [Guangdong Welland Technology Co., Ltd.] (“the applicant”) certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: Hillary Chan Date: 7/10/2026 Title and Company name: Manager / Guangdong Welland Technology Co., Ltd. NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
Guangdong Welland Technology Co., Ltd. 2.911 (d)(5)(ii) Applicant Attestation v1.3 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: Guangdong Welland Technology Co., Ltd. Address: No. 7 Minke East Road, Shiqi Sub-district, Zhongshan, China Product Name: Smart Scale FCC ID: 2AP3Q- FG2415WB Model(s): FG2415WB 2.911(d)(5)(ii) Applicant filing We, [Guangdong Welland Technology Co., Ltd.] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 ,established pursuant to §1.50002 of this chapter,as an entity producing coveredcommunications equipment. Yours sincerely, Name: Hillary Chan Date: 7/10/2026 Title and Company name: Manager / Guangdong Welland Technology Co., Ltd. NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
No. 7 Minke East Road, Shiqi Sub-district Zhongshan China Date: 2026-07-16 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AP3Q- FG2415WB FRN: 0027591197 US Agent – Attestation Statement / Part 2.911(d)(7) Guangdong Welland Technology Co., Ltd. certifies, that as of 2026-07-16, we have designated FCC US Agent, LLC to accept service of process on our behalf for FCC ID: 2AP3Q- FG2415WB Guangdong Welland Technology Co., Ltd. accepts to maintain an agent of service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. FCC US Agent, LLC, accepts as of the date of the filing of this application, the obligation of being the designated agent for the purpose of accepting service of process on behalf of Guangdong Welland Technology Co., Ltd. for FCC ID: 2AP3Q- FG2415WB Designated Agent Information: Company Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected] Sincerely, Company: Guangdong Welland Technology Co., Ltd. Designated Agent: FCC US Agent, LLC Company Representative: Hillary Chan Designated Agent Representative: Tim Payne Signature: Signature:
Guangdong Welland Technology Co., Ltd. Letter of Authorization Company: Guangdong Welland Technology Co., Ltd. Address: No. 7 Minke East Road, Shiqi Sub-district, Zhongshan, China Product Name: Smart Scale Model Number(s): FG2415WB Product Description: Smart Scale We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2026/7/10 Name: Hillary Chan Title: Manager Company: Guangdong Welland Technology Co., Ltd.
Guangdong Welland Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 7/10/2026 Subject; Request for Confidentiality FCC ID: 2AP3Q- FG2415WB To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram BOM List Block Diagram Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Hillary Chan Title: Manager
FG2415WB 标签尺寸:70X58mm 银底黑色 拉丝银 横向拉丝 Smart Scale Fitdays Model:FG2415WB Rating : 6V65mA FCC ID:2AP3Q-FG2415WB Min:5kg/11.02lb/0.787st Max:180kg/400lb/28st Division:0.05kg/0.1lb Power:4×1.5V AAA Batteries Number:FG2415WB Manufacturer: Guangdong Welland Technology Co., Ltd Addaress:No. 85 Minke East Road, Minying Science & Technology Park, Shiqi District, Zhongshan, Guangdong, China Made in China Label location
FCC ID: 2AP3Q- FG2415WB Portable device According to 47 CFR, Part2.1093 and 47 CFR, Part1.1307, systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to KDB447498 D01 General RF Exposure Guidance V06 The 1-g SAR and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHZ)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f(GHZ) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. BLE: Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculation 1g SAR Exclusion threshold SAR test exclusion 2.402 2.89 1.95 3±1 4 2.51 <5 0.77860 3.00 YES 2.440 2.63 1.83 3±1 4 2.51 <5 0.78474 3.00 YES 2.480 2.4 1.74 2±1 3 2.00 <5 0.62843 3.00 YES 2.402 2.7 1.86 2±1 3 2.00 <5 0.61847 3.00 YES 2.440 3.31 2.14 3±1 4 2.51 <5 0.78474 3.00 YES 2.480 2.94 1.97 3±1 4 2.51 <5 0.79114 3.00 YES BLE 1M BLE 2M Conclusion: For the max result :0.8 ≤3.0 for 1-g SAR, SAR is not required. Signature: Date: 2026-06-22 NAME AND TITLE (Please print or type): Alex Li/Manager COMPANY (Please print or type): Shenzhen NTEK Testing Technology Co., Ltd./ No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China
Customer Name: Guangdong Welland Technology Co.,Ltd Product Name: FG2211WB&FI2211LB Reference Standard:GB/T9410-2008;ANSI/IEEE Std 149-1979 Issue Date: 2023.7.17 Engineer: 邱波 Date 2023.7.17 Auditor: 姚常青 Date2023.7.17 Approve 黄俊杰 Date 2023.7.17 1. General Information 1.1 General information of testing institutions 1.2 Test equipment 1.3 Test environment 1.4 Statement 2. Sample Information 2.1 Client information 2.2 Description of EUT(S) 2.3 EUT appearance 2.4 DUT setup photo of free space OTA testing 2.5 Matching circuit 3. Test Result 3.1 Test standard 3.2 Test uncertainty 3.3 Test data 3.3.1 S1l parameters 3.3.2 VSWR 3.3.3 Max Gain 3.3.4 Typical free space efficiency and gain 3.3.5 Typical free space radiation patter 4. Product specifications 5. Environmental regulations and packaging 1. General Information 1. 1 General information oftesting institutions Name Shenzhen DBT Communication Device Co., Ltd Address Rm505, 8th building, Yungu 2nd period, pingshan No.1 Road, Xili Town,Nanshan District, ShenZhen , China Tel 0755-83763273 E-mail [email protected] Equipment 1. ETS 2. Keysight E5071C 1.2 Test equipment ETSE5071C Model No. Manufacturer Calibration date Next calibration date ETS RFI-LAB-RF-A00 2022.11. 132023.11. 13 E5071C Agilent 2022.09. 202023.09. 20 1.3 Test environment Temperature 25. 0*C Humidity 59%RH Pressure 100.12kPa 1.4 Statement (1) The test results in the report are only applicable to the tested samples and the tested samples work under the environment described in the report (2) Any objection to this report shall be raised 30 days after formal confirmation ofthe report. (3) The report is invalid without the signature ofthe auditor and approver. 2.Sample Information 2.1 Client information Name Guangdong Welland Technology Co.,Ltd Address Room222, Building 4 TOP Business Park, No.9 Boai Three Road, Zhongshan,Guangdong,China Contacts Tel E-mail 2.2 Description of EUT(S) Product NameFG2211WB&FI2211LB Antenna Size 14.5*3mm Antenna Type PIFA / PCB Antenna Test Item VSWR; Gain; Efficiency; Radiation pattern Frequency Range2400-2500MHZ Received Date2023.7.15 Test Date2023.7.17 Remark i 2.3 EUT appearance 2.4 DUT setup photo of free space OTA testing 2.5 Matching circuit 3.Test Results 3.1 Test standard NameParameter MethodStandard no. Mobile Communication antenna VSWR Generic specification for antennas used in the mobile communications GB/T 9410-2008 Antenna gain Radiation pattern Antenna Radiation efficiency IEEE Standard Test Procedures for Antennas ANSI/IEEE Std 149-1979 3.2 Test uncertainty The uncertainty was calculated on the basis ofthe GUM published by ISO.using theinclusion factor ofK=2 and the 95% confidence level to express the extended uncertainty. Item Uncertainty VSWR±0.3 Antenna gain + ldB Radiation efficiency ±10% 3.3 Test data 3.3.1 S1l parameters 3.3.2 VSWR Frequency/MHz 24002500 VSWR1.761.6 3.3.3 Max Gain Antenna Gain 2400-2500MHZ 1.85dbi 3.3.4 Typical free space efficiency and gain Freq (MHz) Effi (%) Gain (dBi) 240026.32-1.61 241025.65-1.43 242027.04-0.73 243026.57-0.54 244030.30.21 245029.880.08 246030.410.14 247031.340.25 248036.90.85 249036.471.06 250039.671.85 4.Product specifications 5.Environmental regulations and packaging Operating Temperature Range: -40。C ~ +85。C Storage Temperature Range: -40。C ~ +120。C Antenna be exposed in a 35°C, 5% salt fog chamber for 24 hours then check the appearance and performance against the specifications in normal temperature. The antenna is subjected to the following test: Temperatures: +70 °C and 90%--95%RH Test Duration: 24 Hours The antenna should not undergo any structural or functional change and remain within the electrical/mechanical specification. The antenna will be installed on the PCB.
Report No.: N26042410008E Version.1.3 Page 1 of 64 RADIO TEST REPORT FCC ID: 2AP3Q-FG2415WB Product: Smart Scale Trade Mark: N/A Model No.: FG2415WB Family Model: N/A Report No.: N26042410008E Issue Date: Jun. 22, 2026 Prepared for Guangdong Welland Technology Co., Ltd. No. 7 Minke East Road, Shiqi Sub-district, Zhongshan, China Prepared by Shenzhen NTEK Testing Technology Co., Ltd. No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China Tel. 0755-23200050 Website: http://www.ntek.org.cn Report No.: N26042410008E Version.1.3 Page 2 of 64 Table of Contents Page 1 TEST RESULT CERTIFICATION ...................................................................................................................... 3 2 SUMMARY OF TEST RESULT S ......................................................................................................................... 4 3 FACILITIES AND ACCREDITATIONS ............................................................................................................. 5 3.1 FACILITIES ..................................................................................................................................................... 5 3.2 LABORATORY ACCREDITATIONS AND LISTINGS ................................................................................. 5 3.3 MEASUREMENT UNCERTAINTY ............................................................................................................... 5 4 GENERAL DESCRIPTION OF EUT .................................................................................................................. 6 5 DESCRIPTION OF TEST MODES...................................................................................................................... 8 6 SETUP OF EQUIPMENT UNDER TEST ........................................................................................................... 9 6.1 BLOCK DIAGRAM CONFIGURATION OF TEST SYSTEM ....................................................................... 9 6.2 SUPPORT EQUIPMENT ............................................................................................................................... 10 6.3 EQUIPMENTS LIST FOR ALL TEST ITEMS .............................................................................................. 11 7 TEST REQUIREMENTS .................................................................................................................................... 13 7.1 CONDUCTED EMISSIONS TEST ............................................................................................................... 13 7.2 RADIATED SPURIOUS EMISSION ............................................................................................................ 15 7.3 6DB BANDWIDTH ....................................................................................................................................... 37 7.4 DUTY CYCLE ............................................................................................................................................... 38 7.5 PEAK OUTPUT POWER .............................................................................................................................. 40 7.6 POWER SPECTRAL DENSITY ................................................................................................................... 41 7.7 CONDUCTED BAND EDGE MEASUREMENT ......................................................................................... 43 7.8 SPURIOUS RF CONDUCTED EMISSIONS ................................................................................................ 44 7.9 ANTENNA APPLICATION .......................................................................................................................... 45 8 TEST RESULTS ................................................................................................................................................... 46 8.1 MAXIMUM CONDUCTED OUTPUT POWER ....................................................................................................... 46 8.2 -6DB BANDWIDTH .......................................................................................................................................... 49 8.3 OCCUPIED CHANNEL BANDWIDTH .................................................................................................................. 52 8.4 MAXIMUM POWER SPECTRAL DENSITY LEVEL ............................................................................................... 55 8.5 BAND EDGE .................................................................................................................................................... 58 8.6 CONDUCTED RF SPURIOUS EMISSION ............................................................................................................. 61 Report No.: N26042410008E Version.1.3 Page 3 of 64 1 TEST RESULT CERTIFICATION Applicant’s name ......................... : Guangdong Welland Technology Co., Ltd. Address ....................................... : No. 7 Minke East Road, Shiqi Sub-district, Zhongshan, China Manufacturer's Name .................. : Guangdong Welland Technology Co., Ltd. Address ....................................... : No. 7 Minke East Road, Shiqi Sub-district, Zhongshan, China Product description Product name .............................. : Smart Scale Trade Mark .................................. : N/A Model and/or type reference ...... : FG2415WB Family Model ............................... : N/A Test Sample number ................... : S2604280379-1# Date of Test ................................. : May. 08, 2026 ~ Jun. 22, 2026 Measurement Procedure Used: APPLICABLE STANDARDS APPLICABLE STANDARD/ TEST PROCEDURE TEST RESULT FCC 47 CFR Part 2, Subpart J FCC 47 CFR Part 15, Subpart C ANSI C63.10-2020+Cor 1-2023 KDB 558074 D01 15.247 Meas Guidance v05r02 Complied This device described above h…
Text truncated - open the document above for the full version.
3722 lllinois Avenue · Saint Charles, Illinois, 60174 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.95 mW |

Smart Body Fat Scale
Equipment Class
DTS - Digital Transmission System
Kitchen scale
Equipment Class
DTS - Digital Transmission System
Smart Body Fat Scale
Equipment Class
DTS - Digital Transmission System
Smart Body Fat Scale
Equipment Class
DTS - Digital Transmission System
Smart Body Fat Scale
Equipment Class
DTS - Digital Transmission System