FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Lenodell Technology Co., Ltd./
  3. 2APEI-M8PRO

2APEI-M8PROPortable Outdoor Speaker

Shenzhen Lenodell Technology Co., Ltd.
Portable Outdoor Speaker - FCC ID 2APEI-M8PRO - Shenzhen Lenodell Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Feb 25, 2023
Application Purpose
Original Equipment
Date of Application
Feb 25, 2023
Equipment Note
Portable Outdoor Speaker
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Lenodell Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev 1/26/2023 ShenZhen Lenodell Technology Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date:02-15-2023 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2APEI-M8PRO ShenZhen Lenodell Technology Co.,Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Link Lin Rev 1/26/2023 ShenZhen Lenodell Technology Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 02-15-2023 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2APEI-M8PRO ShenZhen Lenodell Technology Co.,Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Link Lin

Attestation Statements

ShenZhen Lenodell Technology Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2APEI-M8PRO ShenZhen Lenodell Technology Co.,Ltd. (“the applicant”) certifies that, as of the da te of the filing of the application, TianHeng Consulting, LLC is our designated U.S. agent for service of process for the above referenced FCC ID. ShenZhen Lenodell Technology Co.,Ltd. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. TianHeng Consulting, LLC accepts, as of the date of the filing of t he application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Sincerely, Designated U.S. Agent Information: Name: TianHeng Consulting, LLC Contact Person: Hualing Dong Address: 392 Andover Street, Wilmington, MA 01887, United States Tel.: +1 617-997-4010 FRN:0033401258 Email: [email protected] U.S. Agent Signature: Applicant: Company Name: ShenZhen Lenodell Technology Co.,Ltd. Grantee Code: 2APEI Contact Name: Link Lin Address: 2F, 10th Block, Zhongyuntai Industtrial Park, Tangtou No.1 Road, Shiyan Street, Bao'an District, Shenzhen, China Tel.: +86-0755-86257210 Email: [email protected] Applicant Signature: Hualing Dong Link Lin

Cover Letter(s)

Rev 11/20/07 ShenZhen Lenodell Technology Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2APEI-M8PRO Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram “Block Diagram.pdf” Schematics “Schematic.pdf” Operational Description “Operation Description.pdf” The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, ------------------------------- Link Lin

Cover Letter(s)

ShenZhen Lenodell Technology Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2023/01/15 FCC ID: 2APEI-M8PRO SUBJECT: To Whom It May Concern: I, the undersigned, hereby states this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules, and will apply the Supplier's Declaration of Conformity procedure to the class B computer peripheral portion of this composite device. I understand the following FCC requirements: 1. Devices subject to the SDoC procedure are required to be tested to show compliance with the FCC technical regulations by a recognized accredited testing laboratory. The testing laboratory must be accredited by a Commission approved accreditation body or designated under the terms of a government-to-government Mutual Recognition Agreement (MRA). A listing of those accredited testing laboratories that have been recognized by the Commission is published on the FCC Webpage: https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm (Select the "accredited" option to search for FCC recognized accredited test firms.) 2. Pt 2.1077 contains the list of information that must be included in the Supplier's Declaration of Conformity, which must be supplied with each product sold. The SDoC compliance info shall be included in the User’s Manual or as a separate sheet. The info must contain the name, address, and phone number of the responsible party, which must be located within the United States. According to 2.909(b), the responsible party is either the Manufacturer or if the product is imported the Importer. Regards, ShenZhen Lenodell Technology Co.,Ltd. ------------------------------- Link Lin

Cover Letter(s)

G:\2021案件\已递交\1.9-A230104029-LCSA010623045E&047E&048E-陈开梅-蓝牙音箱-CERED&UKCA&FCCID\Report\FCC\Form\POA_Letter.docx ShenZhen Lenodell Technology Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2023/01/15 SUBJECT: FCC Application for (FCC ID: 2APEI-M8PRO) To Whom It May Concern: We, the undersigned, hereby authorize Gavin Liang at Shenzhen LCS Compliance Testing Laboratory Ltd. on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Shenzhen LCS Compliance Testing Laboratory Ltd.on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, ------------------------------- Link Lin

External Photos

Page 1 of 4 FCC ID: 2APEI-M8PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2APEI-M8PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2APEI-M8PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2APEI-M8PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8

ID Label/Location Info

Page 1 of 1 FCC ID: 2APEI-M8PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L: 10.0cm x W: 3.0cm) Label Location Portable Outdoor Speaker Model: M8 Pro FCC ID: 2APEI-M8PRO

Internal Photos

Page 1 of 3 FCC ID: 2APEI-M8PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 3 FCC ID: 2APEI-M8PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 3 FCC ID: 2APEI-M8PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Bluetooth Antenna

RF Exposure Info

Page 1 of 4 FCC ID: 2APEI-M8PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Maximum Permissible Exposure Report 1. Product Information FCC ID 2APEI-M8PRO Product name Portable Outdoor Speaker Model number M8 Pro Additional Model No. T416, BoomBox, Sounder2 Party, Sounder2 Plus, Sounder2 Pro Model Declaration PCB board, structure and internal of these model(s) are the same, So no additional models were tested Power supply Type-C input: 5V2A USB-A output:5V1A Battery :7.4Vdc, 4000mAh, 29.6Wh Modulation Type GFSK, π/4-DQPSK, 8-DPSK for Bluetooth V5.3(DSS) Antenna Type PCB Antenna Antenna Gain -2.41dBi(Max.) Hardware version V:07 Software version V4.0 FCC Operation frequency 2402MHz-2480MHz Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Portable Device 2. Evaluation Method According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation Page 2 of 4 FCC ID: 2APEI-M8PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices 4. Antenna Information EUT can only use antennas certificated as follows provided by manufacturer; Internal/External Identification Antenna type and antenna number Operate frequency band Maximum antenna gain Notes Antenna PCB Antenna 2400MHz~2500MHz -2.41dBi BT Antenna Page 3 of 4 FCC ID: 2APEI-M8PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 5. Conducted Powe…

Text truncated - open the document above for the full version.

Test Report

ShenZhenLenodellTechnologyCo.,Ltd Add: 5th Floor, BuildingB, WentaoIndustrialPark, YongxinStreet, YingrenshiCommunity,Shiyan Street, Baoan District,Shenzhen - 1 - 1,mechanicaldimension a,antennadimension b .antennafinalfigure ShenZhenLenodellTechnologyCo.,Ltd Add: 5th Floor, BuildingB, WentaoIndustrialPark, YongxinStreet, YingrenshiCommunity,Shiyan Street, Baoan District,Shenzhen - 2 - c, antennadirection d. antenna model:L-003-F2 ShenZhen Lenodell Technology Co.,Ltd Add: 5th Floor, Building B, Wentao Industrial Park, Yongxin Street, Yingrenshi Community, Shiyan Street, Baoan District, Shenzhen - 3 - 2,antenna specification Bluetooth mechanical specifiction 2400-2500MHZ Electrical specifications Frequency range(MHz)2400-2500 PolarizationLinear Gain(dBi) -2.41 Impedance (Ω)50 DirectivityOmni-directional VSWR≤2.0(Center frequency) Mechanical specifications Texture of material Immersion tin length Operation Temperature (°C)-30~60 Humidity (%)5~95 3.Gain FrequencyE Total. dB(dB)Efficiency( ) 2400MHz-3.8688616.23% 2410MHz-3.8046217.25% 2420MHz-3.5812417.64% 2430MHz-3.5062418.48% 2440MHz-3.4195517.65% 2450MHz-3.2633617.72% 2460MHz-2.975417.49% 2470MHz-2.6749917.49% 2480MHz-2.4125417.15% ShenZhenLenodellTechnologyCo.,Ltd Add: 5th Floor, BuildingB, WentaoIndustrialPark, YongxinStreet, YingrenshiCommunity,Shiyan Street, Baoan District,Shenzhen - 4 - 4.INSERTIONLOSS/RETURNLOSS/VSWR FrequencyInputimpedance(Ω)Returnloss(dB)VSWR 2400MHz38.886-6.354 2.512 2402MHz37.336-6.412 2.543 2440MHz22.254-6.753 2.501 2480MHz18.320-6.613 2.522 2500MHz18.715-6.702 2.518 ShenZhenLenodellTechnologyCo.,Ltd Add: 5th Floor, BuildingB, WentaoIndustrialPark, YongxinStreet, YingrenshiCommunity,Shiyan Street, Baoan District,Shenzhen - 5 - 5.3DPattern 2400MHZ 2440MHZ ShenZhenLenodellTechnologyCo.,Ltd Add: 5th Floor, BuildingB, WentaoIndustrialPark, YongxinStreet, YingrenshiCommunity,Shiyan Street, Baoan District,Shenzhen - 6 - 2480MHZ

Test Report

Page1of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity AppendixA RFTestDataforBT(ConductedMeasurement) ProductName:PortableOutdoorSpeaker TestModel:M8Pro EnvironmentalConditions Temperature: 23.8  C RelativeHumidity:52.1% ATMPressure:100.0kPa TestEngineer:NickPeng Supervisedby:LingZhu Page2of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.120dBEmissionBandwidth TestResult TestModeAntennaChannel 20db EBW[MHz] FL[MHz]FH[MHz]Verdict DH5Ant1 24020.9752401.5142402.489PASS 24411.0382440.4602441.498PASS 24801.0322479.4692480.501PASS 2DH5Ant1 24021.2962401.3552402.651PASS 24411.3292440.3282441.657PASS 24801.3502479.3192480.669PASS 3DH5Ant1 24021.2662401.3612402.627PASS 24411.2932440.3402441.633PASS 24801.2902479.3432480.633PASS Page3of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 Page4of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2DH5_Ant1_2402 2DH5_Ant1_2441 Page5of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2DH5_Ant1_2480 3DH5_Ant1_2402 Page6of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3DH5_Ant1_2441 3DH5_Ant1_2480 Page7of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page8of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.2Maximumconductedoutputpower TestResult TestModeAntennaChannelResult[dBm]Limit[dBm]Verdict DH5Ant1 24020.51≤20.97PASS 24410.44≤20.97PASS 24800.38≤20.97PASS 2DH5Ant1 24020.01≤20.97PASS 2441-0.08≤20.97PASS 2480-0.03≤20.97PASS 3DH5Ant1 24020.03≤20.97PASS 24410.28≤20.97PASS 24800.33≤20.97PASS Page9of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 Page10of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2DH5_Ant1_2402 2DH5_Ant1_2441 Page11of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2DH5_Ant1_2480 3DH5_Ant1_2402 Page12of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3DH5_Ant1_2441 3DH5_Ant1_2480 Page13of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page14of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.3Carrierfrequencyseparation TestResult TestModeAntennaChannelResult[MHz]Limit[MHz]Verdict DH5Ant1Hop1.012≥0.692PASS 2DH5Ant1Hop1.306≥0.900PASS 3DH5Ant1Hop0.992≥0.862PASS Page15of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs DH5_A…

Text truncated - open the document above for the full version.

Test Report

Page25of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity DH5_Ant1_High_Hop_2480 2DH5_Ant1_Low_2402 Page26of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2DH5_Ant1_High_2480 2DH5_Ant1_Low_Hop_2402 Page27of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2DH5_Ant1_High_Hop_2480 3DH5_Ant1_Low_2402 Page28of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3DH5_Ant1_High_2480 3DH5_Ant1_Low_Hop_2402 Page29of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3DH5_Ant1_High_Hop_2480 Page30of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.7ConductedSpuriousEmission TestResult TestModeAntennaChannel FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant1 2402 Reference-0.88-0.88---PASS 30~1000-0.88-61.23≤-20.88PASS 1000~26500-0.88-45.8≤-20.88PASS 2441 Reference-0.89-0.89---PASS 30~1000-0.89-60.88≤-20.89PASS 1000~26500-0.89-46.26≤-20.89PASS 2480 Reference-1.11-1.11---PASS 30~1000-1.11-60.83≤-21.11PASS 1000~26500-1.11-46.15≤-21.11PASS 2DH5Ant1 2402 Reference-4.91-4.91---PASS 30~1000-4.91-61.06≤-24.91PASS 1000~26500-4.91-45.18≤-24.91PASS 2441 Reference-5.06-5.06---PASS 30~1000-5.06-60.6≤-25.06PASS 1000~26500-5.06-45.97≤-25.06PASS 2480 Reference-5.48-5.48---PASS 30~1000-5.48-60.12≤-25.48PASS 1000~26500-5.48-46.65≤-25.48PASS 3DH5Ant1 2402 Reference-1.90-1.90---PASS 30~1000-1.90-60.75≤-21.9PASS 1000~26500-1.90-46.29≤-21.9PASS 2441 Reference-1.94-1.94---PASS 30~1000-1.94-61.14≤-21.94PASS 1000~26500-1.94-45.96≤-21.94PASS 2480 Reference-3.89-3.89---PASS 30~1000-3.89-60.62≤-23.89PASS 1000~26500-3.89-45.92≤-23.89PASS Page31of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs DH5_Ant1_2402_0~Reference DH5_Ant1_2402_30~1000 DH5_Ant1_2402_1000~26500 Page32of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity DH5_Ant1_2441_0~Reference DH5_Ant1_2441_30~1000 Page33of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity DH5_Ant1_2441_1000~26500 DH5_Ant1_2480_0~Reference Page34of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity DH5_Ant1_2480_30~1000 DH5_Ant1_2480_1000~26500 Page35of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2DH5_Ant1_2402_0~Reference 2DH5_Ant1_2402_30~1000 Page36of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2DH5_Ant1_2402_1000~26500 2DH5_Ant1_2441_0~Reference Page37of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2DH5_Ant1_2441_30~1000 2DH5_Ant1_2441_1000~26500 Page38of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2DH5_Ant1_2480_0~Reference 2DH5_Ant1_2480_30~1000 Page39of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA Shen…

Text truncated - open the document above for the full version.

Test Report

Page41of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3DH5_Ant1_2441_0~Reference 3DH5_Ant1_2441_30~1000 Page42of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3DH5_Ant1_2441_1000~26500 3DH5_Ant1_2480_0~Reference Page43of55FCCID:2APEI-M8PROReportNo.:LCSA010623048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,Baoa…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Link Lin
[email protected]+86-0755-86257210Fax: +86-0755-86257210

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is the maximum conducted output power.

Other Applications from Shenzhen Lenodell Technology Co., Ltd.

Portable Speaker - FCC ID 2APEI-SLAPSTIK - Shenzhen Lenodell Technology Co., Ltd.
2APEI-SLAPSTIK

Portable Speaker

Feb 02, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Portable Party Speaker - FCC ID 2APEI-T502PRO - Shenzhen Lenodell Technology Co., Ltd.
2APEI-T502PRO

Portable Party Speaker

Sep 03, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Cyberpunk Party Speaker - FCC ID 2APEI-R13 - Shenzhen Lenodell Technology Co., Ltd.
2APEI-R13

Cyberpunk Party Speaker

Sep 01, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Portable Speaker - FCC ID 2APEI-VIBE - Shenzhen Lenodell Technology Co., Ltd.
2APEI-VIBE

Portable Speaker

Jun 19, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Portable Wireless Speaker - FCC ID 2APEI-R12 - Shenzhen Lenodell Technology Co., Ltd.
2APEI-R12

Portable Wireless Speaker

Jul 17, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter