Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1. Download the Arlo app and follow the setup instructions for an Arlo SmartHub. 2. Connect the power adapter and the Ethernet cable to your Arlo SmartHub. Set up your Arlo SmartHub To view tutorial videos, find troubleshooting tips, or get support, visit www.arlo.com/support. Have questions? © Arlo Technologies, Inc. Arlo, Arlo logo, and Every Angle Covered are trademarks of Arlo Technologies, Inc. Other trademarks are for reference purposes only. Si ce produit est vendu au Canada, vous pouvez accéder à ce document en français canadien à arlo.com/docs. (If this product is sold in Canada, you can access this document in Canadian French at arlo.com/docs.) For regulatory compliance information including the EU Declaration of Conformity, visit www.arlo.com/about/regulatory/. What’s in the box Arlo International, Ltd. Floor 3, Building 3 University Technology Center Curraheen Road, Cork, Ireland Arlo Technologies, Inc. 2200 Faraday Avenue, Suite 150 Carlsbad, CA 92008 USA October 2018 Arlo SmartHub Power adapter (varies by region) Ethernet cable Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 22cm between the radiator & your body. Industry Canada statement: This device complies with RSS-247 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Ce dispositif est conforme à la norme CNR-247d'Industrie Canada applicable aux appareils radio exempts de licence. Son fonctionnement est sujet aux deux conditions suivantes: (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Caution : (i) the device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems; (ii) high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices. Avertissement: les dispositifs fonctionnant dans la bande 5 150-5 250 MHz sont réservés uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux; (ii) De plus, les utilisateurs devraient aussi être avisés que les utilisateurs de radars de haute puissance sont désignés utilisateurs principaux (c.-à -d., qu’ils ont la priorité) pour les bandes 5 250-5 350 MHz et 5 650-5 850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL. Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. This device complies with ISED's licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d' ISED applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Caution : (i) the device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems; (ii) the maximum antenna gain per…
Text truncated - open the document above for the full version.
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 5.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526- 1188 Fax: 408-526- 1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (obsolete) 2.0 3.0 Jan-31-2012 Updated letter information (obsolete) 3.0 4.0 May-23-2014 Added FCC ID field (current) 4.0 5.0 Sept 16 2014 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 5.0 Arlo Technologies, Inc. 2200 Faraday Ave. Suite 150, Carlsbad, CA 92008, United States Tel: 408-890-3034/Fax: 925-337-3724 Date: 2019/05/24 To: BVCPS, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, _____ Arlo Technologies, Inc.______hereby authorize BVCPS,INC. to act as Certification Body for certifying for the following project(s): (Alro Gen5 Entry Hub, VMB5000) FCC ID: 2APLE18300403 IC: 23815-18300403 We affirm that between BVCPS,INC. and _____ Arlo Technologies, Inc.____, any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Mike Campi / R&D, Regulatory Compliance Engineer Tel: 408-890-3015 Fax: 408-907-8167 E-mail: [email protected]
SCS-F19: Confidentiality Request Letter Page 1 of 3 Rev 5.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (obsolete) 2.0 3.0 Jan-31-2012 Added IC confidentiality letter form (obsolete) 3.0 4.0 March-26-2015 Corrections to STC form. Added reference to KDB (current) 4.0 5.0 Nov 19 2015 SCS-F19: Confidentiality Request Letter Page 2 of 3 Rev 5.0 Arlo Technologies, Inc. 2200 Faraday Ave. Suite 150, Carlsbad, CA 92008, United States Tel: 408-890-3034/Fax: 925-337-3724 Date: 2020/06/10 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: 2APLE18300403 Pursuant to sections 0.457 and 0.459 of CFR 47, we respectfully request permanent confidential treatment of the following Exhibits accompanying this application as: e.g. Block Diagram e.g. Schematics e.g. Operational Description e.g. Software Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Mike Campi / R&D, Regulatory Compliance Engineer Tel: 408-890-3015 Fax: 408-907-8167 E-mail: [email protected] SCS-F19: Confidentiality Request Letter Page 3 of 3 Rev 5.0 Arlo Technologies, Inc. 2200 Faraday Ave. Suite 150, Carlsbad, CA 92008, United States Tel: 408-890-3034/Fax: 925-337-3724 Date: 2020/06/10 To: Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: Short Term Confidentiality Request for FCC ID: 2APLE18300403 To Whom It May Concern: Pursuant to sections 0.457 and 0.459 of CFR 47, and to avoid premature release of sensitive information prior to marketing or release of the product to the public, the applicant requests the following documents contained in this certification application be temporarily withheld from public disclosure for an initial period of 45 or 180 █ days; or for a specified date of / / not to exceed 180 days from the Grant Date. See KDB 726920.. - e.g. User Manual - e.g. Internal Photos /External Photos - e.g. Test Setup photos - etc. - etc. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Sincerely, Mike Campi / R&D, Regulatory Compliance Engineer Tel: 408-890-3015 Fax: 408-907-8167 E-mail: [email protected]
Arlo Technologies, Inc. 2200 Faraday Ave. Suite 150, Carlsbad, CA 92008, United States Tel: 408-890-3034/Fax: 925-337-3724 Declaration for DFS master devices Date: 2020-08-14 FCC ID: 2APLE18300403 We, Arlo Technologies, Inc., hereby declare that the device meets all the other requirements specified in Part 15E Section 15.407. If you should have any question(s) regarding this declaration, please don’t hesitate to contact us. Thank you! ----------------------------------- Mike Campi / R&D, Regulatory Compliance Engineer Tel: 408-890-3015 Fax: 408-907-8167 E-mail: [email protected]
Arlo Technologies, Inc. 2200 Faraday Ave. Suite 150, Carlsbad, CA 92008, United States Tel: 408-890-3034/Fax: 925-337-3724 Expedited Review Letter Date: 2020-08-24 To: Federal Communications Commission Equipment Authorization Division Subject: Expedited Review Approval FCC ID: 2APLE18300403 We, the undersigned, Arlo Technologies, Inc., declare that the FCC ID: 2APLE18300403 is identical to the same performance and function as previously certified DFS tested and approved FCC ID: 2APLE18300398. The differences are as the table below: FCC ID of previously granted device FCC ID: 2APLE18300398 FCC ID of new application FCC ID: 2APLE18300403 Technology: MU-MIMO 802.11a/b/g/n/ac RF chipset: IPQ4019 Same as previous Bandwidth information and differences: 20MHz,40MHz,80MHz Same as previous Differences in DFS functioning, circuitry, software: RF chipset Wi-Fi Chipset driver version Same RF Chipset Same Antenna gain Same Chipset driver version Same DFS functionality and behavior Same DFS circuit design Differences between the products: Modulation: OFDM,OFDMA, and DSSSS Antenna Type: Dipole antenna Antenna directional gain: 5.25 GHz- 5.35 GHz, 2 dBi 5.47 GHz- 5.720 GHz, 3.2 dBi Modulation: Same as the previous. Antenna Type: Same as the previous. Difference: Remove Zigbee and Zwave chips from the original board Name of test labs for the grants: Test Lab: Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch ______________________________ Mike Campi / R&D, Regulatory Compliance Engineer Tel: 408-890-3015 Fax: 408-907-8167 E-mail: [email protected]
Arlo Technologies, Inc. 2200 Faraday Ave. Suite 150, Carlsbad, CA 92008, United States Tel: 408-890-3034/Fax: 925-337-3724 POWER OF ATTORNEY Date: 2020/06/10 FCC ID: 2APLE18300403 To whom it may concern: We, the undersigned, hereby authorize Amanda Wu of Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (BV CPS Taoyuan) of Taiwan to act on our behalf in all manners relating to FCC application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Amanda Wu of BV CPS Taoyuan on our behalf shall have the same effect as acts of our own. If you have any questions regarding the authorization, please don’t hesitate to Contact us. Thank you! Sincerely yours, Mike Campi / R&D, Regulatory Compliance Engineer Tel: 408-890-3015 Fax: 408-907-8167 E-mail: [email protected]
Reference No.:200608E05-1 Page 1/16 CONSTRUCTION PHOTOS OF EUT Reference No.:200608E05-1 Page 2/16 Reference No.:200608E05-1 Page 3/16 Reference No.:200608E05-1 Page 4/16 Adapter 1 (Model: AD2076F10) Reference No.:200608E05-1 Page 5/16 Reference No.:200608E05-1 Page 6/16 Reference No.:200608E05-1 Page 7/16 Reference No.:200608E05-1 Page 8/16 Reference No.:200608E05-1 Page 9/16 Reference No.:200608E05-1 Page 10/16 Adapter 2 (Model: AD2067M20) Reference No.:200608E05-1 Page 11/16 Reference No.:200608E05-1 Page 12/16 Adapter 3 (Model: 2ABB018F 1) Reference No.:200608E05-1 Page 13/16 Reference No.:200608E05-1 Page 14/16 Adapter 4 (Model: P030WM1251) Reference No.:200608E05-1 Page 15/16 Reference No.:200608E05-1 Page 16/16
(Fig. 1) FCC ID: 2APLE18300403 IC: 23815-18300403 LABEL LOCATION The label will be permanently affixed at a conspicuous location on the device. EUT bottom Label
Reference No.:200608E05-2 Page 1/17 CONSTRUCTION PHOTOS OF EUT Reference No.:200608E05-2 Page 2/17 Reference No.:200608E05-2 Page 3/17 Reference No.:200608E05-2 Page 4/17 Reference No.:200608E05-2 Page 5/17 Reference No.:200608E05-2 Page 6/17 Reference No.:200608E05-2 Page 7/17 Reference No.:200608E05-2 Page 8/17 Reference No.:200608E05-2 Page 9/17 Reference No.:200608E05-2 Page 10/17 Reference No.:200608E05-2 Page 11/17 Reference No.:200608E05-2 Page 12/17 Reference No.:200608E05-2 Page 13/17 Reference No.:200608E05-2 Page 14/17 WLAN Ant. No.: 1 Reference No.:200608E05-2 Page 15/17 WLAN Ant. No.: 2 Reference No.:200608E05-2 Page 16/17 Reference No.:200608E05-2 Page 17/17 Sub-GHz Ant.
Report No.: SA180830E03I Page No. 1 / 7 Report Format Version: 6.1.1 Reference No.: 200608E05 RF Exposure Report (Spot Check) Report No.: SA180830E03I FCC ID: 2APLE18300403 Original FCC ID: 2APLE18300398 Test Model: VMB5000 Received Date: June 08, 2020 Test Date: July 24 to Aug. 04, 2020 Issued Date: Aug. 14, 2020 Applicant: Arlo Technologies, Inc. Address: 2200 Faraday Ave. Suite 150, Carlsbad, CA 92008, United States Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300, Ta i w a n Test Location: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300, Ta i w a n FCC Registration / Designation Number: 723255 / TW2022 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. Report No.: SA180830E03I Page No. 2 / 7 Report Format Version: 6.1.1 Reference No.: 200608E05 Table of Contents Release Control Record .................................................................................................................................. 3 1 Certificate of Conformity ...................................................................................................................... 4 2 RF Exposure .......................................................................................................................................... 5 2.1 Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5 2.2 MPE Calculation Formula ................................................................................................................... 5 2.3 Classification ....................................................................................................................................... 5 2.4 Antenna Gain ...................................................................................................................................... 6 2.5 Calculation Result ............................................................................................................................... 7 Report No.: SA180830E03I Page No. 3 / 7 Report Format Version: 6.1.1 Reference No.: 200608E05 Release Control Record Issue No. Description Date Issued SA180830E03I Original release. Aug. 14, 2020 Report No.: SA180830E03I Page No. 4 / 7 Report Format Version: 6.1.1 Reference No.: 200608E05 1 Certificate of Conformity Product: Arlo Gen5 Entry Hub Brand: Arlo Test Model: VMB5000 Sample Status: ENGINEERING SAMPLE Applicant: Arlo Technologies, Inc. Test Date: July 24 to Aug. 04, 2020 Standards: FCC Part 2 (Section 2.1091) IEEE C95.3 -2002 References Test Guidance: KDB 447498 D01 General RF Exposure Guidance v06 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. Prepared by : , Date:Aug. 14, 2020 Phoenix Huang / Specialist Approved by : , Date:Aug. 14, 2020 Clark Lin / Technical Manager Report No.: SA180830E03I Page No. 5 / 7 Report Format Version: 6.1.1 Reference No.: 200608E05 2 RF Exposure 2.1 Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (minutes) Limits For General Population / Uncontrolled Exposure 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f 2 )* 30 30-300 27.5 0.073 0.2 30 300-1500 ... ... f/1500 30 1500-100,000 ... ... 1.0 30 f = Frequency in MHz ; *Plane-wave equivalent power density 2.2 MPE Calculation Formula Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 2.3 Classification The antenna of this product, under normal use condition, is at least 22 cm away from the body of the user. So, this device is classified as Mobile Device. Report No.: SA180830E03I Page No. 6 / 7 Report Format Version: 6.1.1 Reference No.: 200608E05 2.4 Antenna Gain Sub-GHz Ant No. Brand Model Antenna Gain (dBi) Frequency rang (MHz) Antenna type Connector type 1 NA 902P00214N01.5 860~930 PIFA NA WLAN Ant No. Brand Model Antenna Net Gain (dBi) Frequency rang (GHz) Antenna type Connector type Cable Length (mm) 1 NA 9 07X01052X0 2.5 2.4~2.4835 Dipole i-pex 75 1.8 5.15~5.25 2 5.25~5.35 2.2 5.47~5.725 1.6 5.725~5.85 2 NA 9 07X00747X19 2.5 2.4~2.4835 Dipole i-pex 90 2.2 5.15~5.25 1.2 5.25~5.35 3.2…
Text truncated - open the document above for the full version.
Report No.: RF180830E03I-1 Page No. 1 / 47 Report Format Version:6.1.2 Reference No.: 200608E05 FCC Test Report (WLAN) (Spot Check) Report No.: RF180830E03I-1 FCC ID: 2APLE18300403 Original FCC ID: 2APLE18300398 Test Model: VMB5000 Received Date: June 08, 2020 Test Date: July 18 to Aug. 04, 2020 Issued Date: Aug. 14, 2020 Applicant: Arlo Technologies, Inc. Address: 2200 Faraday Ave. Suite 150, Carlsbad, CA 92008, United States Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300, Ta i w a n Test Location: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300, Ta i w a n FCC Registration / Designation Number: 723255 / TW2022 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. Report No.: RF180830E03I-1 Page No. 2 / 47 Report Format Version:6.1.2 Reference No.: 200608E05 Table of Contents Release Control Record .................................................................................................................................. 3 1 Certificate of Conformity ...................................................................................................................... 4 2 Summary of Test Results ..................................................................................................................... 5 2.1 Measurement Uncertainty ................................................................................................................... 5 2.2 Modification Record ............................................................................................................................ 5 3 General Information .............................................................................................................................. 6 3.1 General Description of EUT (WLAN) .................................................................................................. 6 3.2 Description of Test Modes ................................................................................................................... 9 3.2.1 Test Mode Applicability and Tested Channel Detail ............................................................................ 11 3.3 Duty Cycle of Test Signal .................................................................................................................. 13 3.4 Description of Support Units ............................................................................................................. 14 3.4.1 Configuration of System under Test .................................................................................................. 15 3.5 General Description of Applied Standard and References ............................................................... 16 4 Test Types and Results ...................................................................................................................... 17 4.1 Radiated Emission and Bandedge Measurement ............................................................................. 17 4.1.1 Limits of Radiated Emission and Bandedge Measurement .............................................................. 17 4.1.2 Test Instruments ................................................................................................................................ 18 4.1.3 Test Procedure .................................................................................................................................. 20 4.1.4 Deviation from Test Standard ............................................................................................................ 20 4.1.5 Test Setup .......................................................................................................................................... 21 4.1.6 EUT Operating Condition .................................................................................................................. 22 4.1.7 Test Results ....................................................................................................................................... 23 4.2 Conducted Emission Measurement .................................................................................................. 37 4.2.1 Limits of Conducted Emission Measurement .................................................................................... 37 4.2.2 Test Instruments ................................................................................................................................ 37 4.2.3 Test Procedure .................................................................................................................................. 38 4.2.4 Deviation from Test Standard ...........................…
Text truncated - open the document above for the full version.
Report No.: RF180830E03-1 Page No. 1 / 71 Report Format Version:6.1.2 Reference No.: 180830E03 FCC Test Report Report No.: RF180830E03-1 FCC ID: 2APLE18300394 Test Model: VMB5000 Received Date: Sep. 04, 2018 Test Date: Sep. 08 to Oct. 13, 2018 Issued Date: Nov. 01, 2018 Applicant: Arlo Technologies, Inc. Address: 2200 Faraday Ave. Suite 150, Carlsbad, CA 92008, United States Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300, Taiwan R.O.C. Test Location: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300, Taiwan R.O.C. FCC Registration / Designation Number: 723255 / TW2022 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF180830E03-1 Page No. 2 / 71 Report Format Version:6.1.2 Reference No.: 180830E03 Table of Contents Release Control Record .................................................................................................................................. 4 1 Certificate of Conformity ...................................................................................................................... 5 2 Summary of Test Results ...............................................................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 4 | 15E | 5.75 GHz - 5.83 GHz | 491.00 mW |
Wired Floodlight Camera
Equipment Class
DTS - Digital Transmission System
Pro 5 Wire-Free Spotlight Camera
Equipment Class
DTS - Digital Transmission System
Essential 2 Camera Family
Equipment Class
DTS - Digital Transmission System
Arlo Essential 2 Indoor Camera
Equipment Class
DTS - Digital Transmission System
Arlo Essential 2 Video Doorbell
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter