FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Sonoff Technologies Co., Ltd./
  3. 2APN5ZBMINI

2APN5ZBMINIZigBee Smart Switch

Shenzhen Sonoff Technologies Co., Ltd.
ZigBee Smart Switch - FCC ID 2APN5ZBMINI - Shenzhen Sonoff Technologies Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 03, 2020
Application Purpose
Original Equipment
Date of Application
Aug 03, 2020
Equipment Note
ZigBee Smart Switch
Frequency Range
2405.00000000 - 2480.00000000
Company
Shenzhen Sonoff Technologies Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ZigBee Smart Switch User manual V1.0 ·中 文 ------------1 - 4 ·English ------- 5-8 · Español -----13-16 · Français --------17-20 · Deutsch ---------9-12 · Italiano------21-24 ·Русский язык-- 25-28 N In LOut S2 L In S1 N In ·Português---29-32 ZBMINI ·FCC Warning------- 33 使用说明 设备安装、故障维修请由专业资质电工操作,以免发生触电危险!设备在正常使用的情 况下不可触碰到。 1.断电 本设备需连接SONOFF ZigBee网关进行智能操作。 设备支持其他无线协议为ZigBee 3.0的网关,具体以实际产品为准。 2.接线 N In LOut S2 L In S1 N In L In N In 100-240V AC 确保零火线接入无误。 S1/S2接或不接机械开关两端(不支持自动回弹的机械开关),设备都可以正常使用。 为确保安全,请勿接入零火线等强电。 ON OFF ONOFF ONOFF Shenzhen Sonoff Technologies Co.,Ltd. 中 文 eWeLink 3. 下载“易微联”APP 1 N In LOut S2 L In S1 N In 通电后,设备首次使用,默认进入配对状态,信号指示灯呈“闪烁”状态。 4.上电 如长时间未进行下一步操作,设备可能退出配对模式,如需再次进入,长按手动开关5秒 直到信号指示灯“闪烁”即可。 L In N In 5.添加子设备 ZBBridge 已添加设备:0 暂无子设备,请添加 添加 打开eWeLink APP,选择要连接的网关,点击 "添加" 子设备,等待搜索添加设备。 如添加失败,请将设备移近网关后再重新添加。 添加子设备前,请先连接网关。 添加设备 正在连接 请让设备尽量靠近网关 25s 找到设备 1个设备 已找到 > SONOFF ZigBee网关支持同时连接多个子设备 添加设备 正在连接 请让设备尽量靠近网关 15s 找到设备 3个设备 已找到 > 先将网关通电,设置让所需配对的子设备进入配对状态,然后打开eWeLink APP网关页面, 点击“添加”,等待搜索添加设备。 ZBBridge 已添加设备:0 暂无子设备,请添加 添加 Shenzhen Sonoff Technologies Co.,Ltd. 中 文 2 本设备除支持SONOFF ZigBee网关外,还支持以下网关: Echo Studio Echo Plus (型号: ZE39KL) 2nd Gen Echo Show (型号: DW84JL) 2nd Gen Echo Plus (型号: L9D29R) Samsung SmartThings hub 更多APP应用平台及网关推荐 1. 参照网关使用说明书下载相应APP和连接网关。 2. 将设备设置到配对模式. 3. 根据网关对应的APP提示添加设备,添加过程中选择 eWeLink 或 SONOFF 品牌。 如添加失败,请将设备移近网关后再重新添加。 添加说明: 产品参数 产品型号 输入 输出 ZigBee 工作温度 外壳材料 产品规格 ZBMINI 100-240V AC 50/60Hz 10A Max IEEE 802.15.4 2.4GHz -10~40°C PC 42.6x42.6x20mm 100-240V AC 50/60Hz 10A Max 最大负载 10A/2200W 支持平台 Android & iOS Shenzhen Sonoff Technologies Co.,Ltd. 中 文 Amazon Alexa SmartThings 3 N In LOut S2 L In S1 N In ZigBee信号指示灯 电源指示灯 配置按钮/手动开关 产品介绍 设备重量<1Kg,建议安装高度<2米。 产品特点 SONOFF智能开关 (ZigBee版) 基于ZigBee无线通讯协议,通过连接ZigBee网关实现远程 控制、设置定时开/关、设备智能场景联动等功能。 远程控制 智能定时/延时 语音控制 智能场景控制 以上功能特点取决于ZigBee网关的功能。 恢复出厂设置 长按配置按钮5秒直到信号指示灯呈“闪烁”状态,再松开,此时设备重置成功,默认进入 配对状态。 设备重新与网关进行配对时,需要将设备恢复为出厂状态。 N In LOut S2 L In S1 N In Shenzhen Sonoff Technologies Co.,Ltd. 中 文 分享功能 4 1. Power off 2. Wiring instruction The device can be operated intelligently via working with the SONOFF ZigBee Bridge. The device can work with other gateways supporting ZigBee 3.0 wireless protocol. Detailed information is in accordance with the final product. Operation instruction To avoid electric shocks, please consult the dealer or a qualified professional for help when installing and repairing! Please do not touch the switch during use. Make sure the neutral wire and live wire connection is correct. S1/S2 can connect with the rocker light switch (the self-return rocker light switch is not supported) or doesn't connect. To ensure safety, do not connect the neutral wire and live wire to it. Shenzhen Sonoff Technologies Co.,Ltd. ON OFF ONOFF ONOFF N In LOut S2 L In S1 N In L In N In 100-240V AC 3. Download APP eWeLink eWeLink 5 4. Power on After powering on, the device will enter the pairing mode during the first use and the LED signal indicator flashes. The device will exit the pairing mode if no next operation for a long time. If enter again, please long press the manual switch for 5s until the LED signal indicator flashes and release. N In LOut S2 L In S1 N In L In N In 5. Add sub-devices Connect the Bridge before adding the sub-device. Access eWeLink APP, select the Bridge that you want to connect, and tap “Add” to add a sub-device, and be patient until pairing completes. If the addition failed, move the sub-device closer to the Bridge and try again. > Connecting Keep the device close enough to the hub. 35s Add Device Looking for device 1 devices Found ZBBridge Added:0 No child device,please add. Add SONOFF ZigBee Bridge supports connecting multiple sub-devices at the same time. Connecting Keep the device close enough to the hub. 25s Add Device Looking for device 3 devices Found > ZBBridge Added:0 No child device,please add. Add Power the Bridge on, set the sub-device to the pairing mode. Then access the Bridge page in the eWeLink APP to tap “Add”, and be patient until the pairing completes. Shenzhen Sonoff Technologies Co.,Ltd. 6 This device supports the following gateways besides SONOFF ZigBee: Echo Studio Echo Plus (model: ZE39KL) 2nd Gen Echo Show (model: DW84JL) 2nd Gen Echo Plus (model: L9D29R) Samsung SmartThings hub More APP application platforms and gateway recommendations Gateway adding instruction: 1. Refer to the gateway user manual to download the matched APP and get it paired. 2. Set ZBMINI to the pairing mode. 3. Add ZBMINI according to the prompt of APP. You should select eWeLink or SONOFF when adding. If the addition failed, move the sub-device closer to the Bridge and try again. Specifications ZigBee ZBMINI 100-240V AC 50/60Hz 10A Max IEEE 802.15.4 2.4GHz -10~40°C PC 42.6x42.6x20mm 100-240V AC 50/60Hz 10A Max Model Input Output Material Dimension Working temperature Operating systems Android & iOS Shenzhen Sonoff Technologies Co.,Ltd. Amazon Alexa SmartThings 7 N In LOut S2 L In S1 N In Product Introduction Pairing button/Manual switch LED signal indicator(Green) On/Off LED indicator(red) The device weight is less than 1 kg. The installation height of less than 2 m is recommended. SONOFF ZigBee smart devices based on ZigBee wireless communication protocol allow you to remotely turn on/off, schedule on/off connected devices, and set smart scenes, etc. Features Above functions are determined by ZigBee Hub. Remote Control Single/Countdown Timing Voice Control Smart Scene Share Control Factory Reset Long press the configuration button for 5s until the LED signal indicator flashes and release, then the reset is successful. The device enters pairing mode. If pair the device with hub again, please reset the device to factory default. N In LOut S2 L In S1 N In Shenzhen Sonoff Technologies Co.,Ltd. 8 1. Ausschalten 2. Verkabelungsanleitung Das Gerät kann intelligent betrieben werden, indem man mit dem SONOFF ZigBee Gateway arbeitet. Das Gerät kann mit anderen Gateways zusammenarbeiten, die das drahtlose ZigBee 3…

Text truncated - open the document above for the full version.

Cover Letter(s)

QA-FR- 170-B Shenzh en Sonoff Technologies Co.,Ltd. ADD: 1001, BLDG8, Lianhua Industrial Park, shenzhen, GD, China TEL: 0755-27955416 FAX: 0755-27955416 E-mail: [email protected] FCC Authorization Date: 2020-07-15 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We , Shenzhen Sonoff Technologies Co.,Ltd., Hereby authorizes Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratory Corporation on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Client’s signature Printed Name: Jerry Shi Title: Manager

Cover Letter(s)

QA-FR-171-A Shenzhen Sonoff Technologies Co.,Ltd. Add: 1001, BLDG8, Lianhua Industrial Park, shenzhen, GD, China Tel: 0755-27955416 Fax: 0755-27955416 Email: [email protected] FCC Confidential Authorization Date:2020-07-15 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2APN5ZBMINI In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Shenzhen Sonoff Technologies Co.,Ltd. hereby requests long-term confidential treatment of information accompanying this application as outlined below: •Block Diagram •Schematics •Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature: Jerry Shi Manager

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Antenna

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG200604020-00A Page 10 of 33 FCC §15.247 (i) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) Applicable Standard According to subpart 15.247(i)and subpart §1.1310, systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f²) 30 30–300 27.5 0.073 0.2 30 300–1500 / / f/1500 30 1500–100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to §1.1310 and §2.1091 RF exposure is calculated. Calculation formula: Prediction of power density at the distance of the applicable MPE limit S = PG/4πR² = power density (in appropriate units, e.g. mW/cm 2 ); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); Calculated Data: Frequency (MHz) Antenna Gain Conducted output power including Tune- up Tolerance Evaluation Distance (cm) Power Density (mW/cm 2 ) MPE Limit (mW/cm 2 ) (dBi) (numeric) (dBm)(mW) 2405-2480 21.58 86.31 20.00 0.002 1.0 Result: The device meet FCC MPE at 20 cm distance

Test Report

FCC PART 15.247 TEST REPORT For Shenzhen Sonoff Technologies Co.,Ltd. 1001, BLDG8, Lianhua Industrial Park, shenzhen, GD, China Report Type: Original Report Product Type: ZigBee Smart Switch Report Number: RDG200604020-00A Report Date: 2020-07-02 Reviewed By: Ivan Cao Assistant Manager Test Laboratory: Bay Area Compliance Laboratories Corp. (Dongguan) No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn FCC ID:2APN5ZBMINI Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG200604020-00A Page 2 of 33 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 4 TEST METHODOLOGY .................................................................................................................................................. 4 MEASUREMENT UNCERTAINTY .................................................................................................................................... 5 TEST FACILITY ............................................................................................................................................................. 5 DECLARATIONS ............................................................................................................................................................ 5 SYSTEM TEST CONFIGURATION .......................................................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 6 EUT EXERCISE SOFTWARE .......................................................................................................................................... 6 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 7 LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................ 7 SUPPORT CABLE LIST AND DETAILS ............................................................................................................................ 7 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 8 SUMMARY OF TEST RESULTS ............................................................................................................................... 9 FCC §15.247 (i) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) ....................................... 10 APPLICABLE STANDARD ............................................................................................................................................ 10 FCC §15.203 - ANTENNA REQUIREMENT ........................................................................................................... 11 APPLICABLE STANDARD ............................................................................................................................................ 11 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 11 FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS ..................................................................................... 12 APPLICABLE STANDARD ............................................................................................................................................ 12 EUT SETUP ................................................................................................................................................................ 12 EMI TEST RECEIVER SETUP ....................................................................................................................................... 12 TEST PROCEDURE ...................................................................................................................................................... 13 CORRECTED AMPLITUDE & MARGIN CALCULATION ................................................................................................. 13 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 13 TEST DATA ................................................................................................................................................................ 14 FCC §15.209, §15.205 & §15.247(d) - SPURIOUS EMISSIONS ............................................................................. 16 APPLICABLE STANDARD ............................................................................................................................................ 16 EUT SETUP ................................................................................................................................................................ 16 EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP .............................................................................................. 17 TEST PROCEDURE ...................................................................................................................................................... 17 CORRECTED AMPLITUDE & M…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions Front View Conducted Emissions Side View Radiated Emission Below 1GHz View Radiated Emission Above 1GHz View

Contact Information

Applicant

Freddie Duan(Manager)
[email protected]0755-29610458Fax: 0755-27955416

Test Firm

Bay Area Compliance Laboratories Corp.(Dongguan)David Zhang
[email protected]0086 0769 86858888

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz5.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted. The antenna(s) must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating and installation instructions to ensure RF exposure compliance.

Other Applications from Shenzhen Sonoff Technologies Co., Ltd.

Zigbee Temperature Humidity Sensor - FCC ID 2APN5-SNZB02UL - Shenzhen Sonoff Technologies Co., Ltd.
2APN5-SNZB02UL

Zigbee Temperature Humidity Sensor

Aug 12, 2026

Equipment Class

DTS - Digital Transmission System
Matter Over WiFi Smart Switch - FCC ID 2APN5-MINI1GSP - Shenzhen Sonoff Technologies Co., Ltd.
2APN5-MINI1GSP

Matter Over WiFi Smart Switch

Jul 15, 2026

Equipment Class

DTS - Digital Transmission System
Zigbee/Thread USB Dongle - FCC ID 2APN5-DONGLEPP10 - Shenzhen Sonoff Technologies Co., Ltd.
2APN5-DONGLEPP10

Zigbee/Thread USB Dongle

Jul 13, 2026

Equipment Class

DTS - Digital Transmission System
Matter Over WiFi Smart Plug - FCC ID 2APN5-S61STPB - Shenzhen Sonoff Technologies Co., Ltd.
2APN5-S61STPB

Matter Over WiFi Smart Plug

Jul 10, 2026

Equipment Class

DTS - Digital Transmission System
Zigbee Siren - FCC ID 2APN5-SNZB09P - Shenzhen Sonoff Technologies Co., Ltd.
2APN5-SNZB09P

Zigbee Siren

Jul 08, 2026

Equipment Class

DTS - Digital Transmission System