< SHENZHEN LANNENGSHITONG ELECTRONICS CO.,LTD > Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD21046 Date: 2020-04-26 Subject; Request for Long Term Confidentiality FCC ID: 2APNH-UVCX1001 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: jun xiong Title: R&d department supervisor
SHENZHEN LANNENGSHITONG ELECTRONICS CO.,LTD Letter of Authorization Company: SHENZHEN LANNENGSHITONG ELECTRONICS CO.,LTD Address: Floor3 No.40 xinhe road shangmugu village Pinghu neighborhood Longgang District, Shenzhen 518110, China Product Name: 3 in 1 UVC Box Sanitizer Model Number(s): UVCX1001 Product Description: 3 in 1 UVC Box Sanitizer We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2020-04-26 Name: jun xiong Title: R&d department supervisor Company: SHENZHEN LANNENGSHITONG ELECTRONICS CO.,LTD
Test Model No.: UVCX1001
1 8 . 0 6 m m 96.69 mm
Model No.:UVCX1001
FCC ID: 2APNH-UVCX1001 RF Exposure Evaluation 1 Requirements KDB 680106 D01 RF Exposure Wireless Charging Apps v03 YES Power transfer frequency is less than 1 MHz. YES Output power from each primary coil is less than or equal to 15 watts. YES The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. YES Client device is placed directly in contact with the transmitter. YES Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). YES The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. 2 Test Instruments list Test Equipment Manufacturer Model No. SN. Cal.Date (mm-dd-yy) Cal.Due date (mm-dd-yy) Exposure Level Tester Narda ELT-400 N-0231 June. 26 2019 June. 25 2020 Magnetic field probe 100cm 2 Narda ELT probe 100cm 2 M0675 June. 26 2019 June. 25 2020 3 Test Result Full load: E-Filed Strength 15cm 20cm Limits (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E 0.111-0.20654 0.29 0.24 0.38 0.15 0.34 614 H-Filed Strength 15cm 20cm Limits (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E 0.111-0.20654 0.11 0.34 0.18 0.23 0.17 1.63 Half load: E-Filed Strength 15cm 20cm Limits (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E 0.111-0.20654 0.13 0.21 0.33 0.08 0.26 614 H-Filed Strength 15cm 20cm Limits (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E 0.111-0.20654 0.12 0.23 0.11 0.12 0.09 1.63 Empty load: E-Filed Strength 15cm 20cm Limits (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E 0.111-0.20654 0.11 0.08 0.13 0.07 0.16 614 H-Filed Strength 15cm 20cm Limits (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E 0.111-0.20654 0.09 0.16 0.09 0.14 0.14 1.63 4 Test Set-up Photo
Global United Technology Services Co., Ltd. Report No.: GTS202004000105F01 Authorized Signature: Robinson Lo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 19 TEST REPORT Applicant: SHENZHEN LANNENGSHITONG ELECTRONICS CO.,LTD Address of Applicant: Floor3 No.40 xinhe road shangmugu village Pinghu neighborhood Longgang District, Shenzhen 518110, China Manufacturer/Factory: SHENZHEN LANNENGSHITONG ELECTRONICS CO.,LTD Address of Manufacturer/Factory: Floor3 No.40 xinhe road shangmugu village Pinghu neighborhood Longgang District, Shenzhen 518110, China Equipment Under Test (EUT) Product Name: 3 in 1 UVC Box Sanitizer Model No.: UVCX1001 FCC ID: 2APNH-UVCX1001 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Date of sample receipt: April 16, 2020 Date of Test: April 17-26, 2020 Date of report issued: April 26, 2020 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS202004000105F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 19 2 Version Version No. Date Description 00 April 26, 2020 Original Prepared By: Date: April 26, 2020 Project Engineer Check By: Date: April 26, 2020 Reviewer Report No.: GTS202004000105F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 19 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 4.1 MEASUREMENT UNCERTAINTY ............................................................................................................ 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 6 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 6 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 6 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 6 5.6 TEST FACILITY .................................................................................................................................... 6 5.7 TEST LOCATION ................................................................................................................................. 6 5.8 OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................... 6 6 TEST INSTRUMENTS LIST ..................................................................................................................... 7 7 TEST RESULTS AND MEASUREMENT DATA ...................................................................................... 9 7.1 ANTENNA REQUIREMENT: .................................................................................................................... 9 7.2 CONDUCTED EMISSIONS ................................................................................................................... 10 7.3 RADIATED EMISSION METHOD ........................................................................................................... 13 7.4 20DB OCCUPY BANDWIDTH .............................................................................................................. 18 8 TEST SETUP PHOTO ............................................................................................................................ 19 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 19 Report No.: GTS202004000105F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 19 4 Test Summary Test Item Section in CFR 47 Result Antenna requirement 15.203 Pass AC Power Line Conducted Emission 15.207 Pass Radiated Emission 15.209 Pass 20dB Bandwidth 15.215 Pass Pass: The EUT complies with the essential requirements in the standard. 4.1 Measurement Uncertainty Test Item Frequency Range Measurement Uncertainty Notes Radiated Emission 30MHz-200MHz 3.8039dB (1) Radiated Emission 200MHz-1GHz 3.9679dB (1) AC Power Line Conducted Emission 0.15MHz ~ 30MHz 3.44dB (1) Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%. Rep…
Text truncated - open the document above for the full version.
Test Model No.: UVCX1001 Radiated Emission Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.111 MHz - 0.20654 MHz | - |