FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Mercku Inc./
  3. 2APR4-M6P

2APR4-M6PM6a Plus Mesh Wi-Fi Router

Mercku Inc.
M6a Plus Mesh Wi-Fi Router - FCC ID 2APR4-M6P - Mercku Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 22, 2022
Application Purpose
Original Equipment
Date of Application
Dec 20, 2022
Equipment Note
M6a Plus Mesh Wi-Fi Router
Frequency Range
2412.00000000 - 2462.00000000
Company
Mercku Inc.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Mercku Inc. Company: Mercku Inc. Address: 3600 Steeles Avenue East, Suite C108B, Markham, Ontario, L3R 9Z7, Canada Product Name: M6a Plus Mesh Wi-Fi Router Model Number: M6a Plus FCC Identifier: 2APR4-M6P We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Shi Ge Date: 2022/11/30 Title: CEO Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.1 1/1 Mercku Inc. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2022/11/30 Subject: Request for Confidentiality FCC ID: 2APR4-M6P To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality ID Label/Location No No Attestation Statement No No External Photos No Block Diagram Schematics Test Report No No Test Setup Photos No User’s Manual Internal Photos Parts List / Tune Up RF Exposure Info Operational Description Cover Letter(s) No No SDR Software / Security Info No In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of _180_ days from the date of the Grant of Equipment Authorization and prior to marketing. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Shi Ge Title: CEO

Cover Letter(s)

Mercku Inc. 3600 Steeles Avenue East, Suite C108B, Markham, Ontario, L3R 9Z7, Canada DATE : 2022-11-30 Mercku Inc. 3600 Steeles Avenue East, Suite C108B, Markham, Ontario, L3R 9Z7, Canada Attn: Director of Certification Authority to Act as Agent On our behalf, I appoint below company and person: Name Damon Hu Position Manager Company Name Dongguan Dongdian Testing Service Co.,Ltd. Address 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City, Guangdong Province, China, 523808 Tel / Fax Tel: +86-0769-38826678-850 E-Mail [email protected] to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. Applicant name Mercku Inc. Address 3600 Steeles Avenue East, Suite C108B, Markham, Ontario, L3R 9Z7, Canada Yours sincerely, Signatory Name Shi Ge Position CEO Company Name Mercku Inc. Address 3600 Steeles Avenue East, Suite C108B, Markham, Ontario, L3R 9Z7, Canada Tel / Fax +86 15210895289 / E-Mail [email protected]

External Photos

Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R22100908-2E01 Page 165 of 173 14. Photos of the EUT Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R22100908-2E01 Page 166 of 173 Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R22100908-2E01 Page 167 of 173 Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R22100908-2E01 Page 168 of 173 Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R22100908-2E01 Page 169 of 173

ID Label/Location Info

采购印刷版 ��mm ��mm 工厂打印版 FCC ID: 2APR4-M6P IC: 23877-M6P http://mywifi.mercku.tech Power: 12V 1.5A M6a Plus Mesh Wi-Fi Router Model: M6a Plus M6a 产品底部标签 尺寸:18mm x 90mm 1、字体采用微软雅黑-Regular 5pt (可根据实际调整字体大小,保证印刷清晰可见即可) 2、打印内容居中打印区域即可

Internal Photos

Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R22100908-2E01 Page 169 of 173 Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R22100908-2E01 Page 170 of 173 Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R22100908-2E01 Page 171 of 173 2.4G/5G WIFI Antenna 1/2 Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R22100908-2E01 Page 172 of 173 Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R22100908-2E01 Page 173 of 173 END OF REPORT

RF Exposure Info

Dongguan Dongdian Testing Service Co., Ltd Report No.:DDT-R22100908-2E16 Page 1 of 9 RF EXPOSURE REPORT FOR Issued By: Dongguan Dongdian Testing Service Co., Ltd. Add.: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City, Guangdong Province, China, 523808 Tel.: +86-0769-38826678, E-mail: [email protected], http://www.dgddt.com Applicant : Mercku Inc. Address : 3600 Steeles Avenue East, Suite C108B, Markham, Ontario, L3R 9Z7, Canada Equipment under Test : M6a Plus Mesh Wi-Fi Router Model No. : M6a Plus Trade Mark : MERCKU FCC ID : 2APR4-M6P Manufacturer : Mercku Technology (China), Inc. Address : Block B1, Southern Software Park No.1 Software Road, Tangjia Zhuhai, Guangdong, China Report No.: DDT-R22100908-2E16 Issued Date: Nov. 22, 2022 Dongguan Dongdian Testing Service Co., Ltd Report No.:DDT-R22100908-2E16 Page 2 of 9 Table of Contents Test report declares.......................................................................................................3 1. General Information ....................................................................................................... 5 1.1. Description of equipment ............................................................................................... 5 1.2. Assess laboratory ........................................................................................................... 7 2. RF Exposure Evaluation ................................................................................................ 7 2.1. Requirement ................................................................................................................... 7 2.2. Calculation method ........................................................................................................ 8 2.3. Estimation result ............................................................................................................. 8 Dongguan Dongdian Testing Service Co., Ltd Report No.:DDT-R22100908-2E16 Page 3 of 9 Test Report Declare Standard Used: KDB447498 D01 General RF Exposure Guidance v06 We Declare: The equipment described above is assessed by Dongguan Dongdian Testing Service Co., Ltd and in the configuration assessed the equipment complied with the standards specified above. The assessed results are contained in this report and Dongguan Dongdian Testing Service Co., Ltd is assumed of full responsibility for the accuracy and completeness of these assess. After evaluation, our opinion is that the equipment In Accordance with above standard. Report No: DDT-R22100908-2E16 Date of Receipt: Oct. 13, 2022 Date of Test: Oct. 13, 2022 ~ Nov. 22, 2022 Prepared By: Approved By: ___________________ ______________________ Johnny Wang/Engineer Damon Hu/EMC Manager Note: This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Dongguan Dongdian Testing Service Co., Ltd. Applicant : Mercku Inc. Address : 3600 Steeles Avenue East, Suite C108B, Markham, Ontario, L3R 9Z7, Canada Equipment under Test : M6a Plus Mesh Wi-Fi Router Model No. : M6a Plus Trade mark : MERCKU Manufacturer : Mercku Technology (China), Inc. Address : Block B1, Southern Software Park No.1 Software Road, Tangjia Zhuhai, Guangdong, China E S T T I N N A I G D S G E N R O V D I C E N A C U O G . , G L N T O D D . Dongguan Dongdian Testing Service Co., Ltd Report No.:DDT-R22100908-2E16 Page 4 of 9 Revision History Rev. Revisions Issue Date Revised By --- Initial issue Nov. 22, 2022 Dongguan Dongdian Testing Service Co., Ltd Report No.:DDT-R22100908-2E16 Page 5 of 9 1. General Information 1.1. Description of equipment 2.4G WIFI: Antenna information Ant1 gain Ant2 gain MIMO IEEE 802.11b 3.9 3.9 / IEEE 802.11g 3.9 3.9 / IEEE 802.11n HT20 3.9 3.9 6.91 IEEE 802.11n HT40 3.9 3.9 6.91 IEEE 802.11ax HE20 3.9 3.9 6.91 IEEE 802.11ax HE40 3.9 3.9 6.91 EUT* Name : M6a Plus Mesh Wi-Fi Router Model Number : M6a Plus EUT function description : Please reference user manual of this device Power Supply : DC 12V 1.5A from external AC/DC Adapter Sample Type : Series production Sample Number : S22100908-01 Radio Technology : IEEE 802.11b/g/n/ax Operation frequency : IEEE 802.11b: 2412 MHz - 2462 MHz IEEE 802.11g: 2412 MHz - 2462 MHz IEEE 802.11n HT20: 2412 MHz - 2462 MHz IEEE 802.11n HT40: 2422 MHz - 2452 MHz IEEE 802.11ax HE20: 2412 MHz - 2462 MHz IEEE 802.11ax HE40: 2422 MHz - 2452 MHz Modulation : IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ax: OFDM, OFDMA (1024QAM, 256QAM, 64QAM, 16QAM, QPSK, BPSK) Transmitter rate : IEEE 802.11b: 1, 2, 5.5, 11 Mbps IEEE 802.11g: 6, 9, 12, 18, 24, 36, 48, 54 Mbps IEEE 802.11n HT20: up to 144.4 Mbps IEEE 802.11n HT40: up to 300 Mbps IEEE 802.11ax HE20: up to 286.8 Mbps IEEE 802.11ax HE40: up to 573.6 Mbps Antenna Gain : Ant1: 3.9 dBi Ant2: 3.9 dBi Dongguan Dongdian Testing Service Co., Ltd Report No.:DDT-R22100908-2E16 Page 6 of 9 5G WIFI: Antenna information Ant1 gain Ant2 gain MIMO IEEE 802.11a 7 7 / IEEE 802.11n HT20 7 7 10.01 IEEE 802.11n HT40 7 7 10.01 IEEE 802.11ac VHT20 7 7 10.01 IEEE 802.11ac VHT40 7 7 10.01 IEEE 802.11ac VHT80 7 7 10.01 IEEE 802.11ax HE20 7 7 10.01 IEEE 802.11ax HE40 7 7 10.01 IEEE 802.11ax HE80 7 7 10.01 Radio Technology : IEEE 802.11a/n/ac/ax Operation frequency : IEEE 802.11a: 5180MHz-5240MHz, 5260MHz-5320MHz, 5500MHz-5700MHz, 5745MHz-5825MHz IEEE 802.11n HT20: 5180MHz-5240MHz, 5260MHz-5320MHz, 5500MHz-5700MHz, 5745MHz-5825MHz IEEE 802.11n HT40: 5190MHz-5230MHz, 5270MHz-5310MHz, 5510MHz-5670MHz, 5755MHz-5755MHz IEEE 802.11ac HT20: 5180MHz-5240MHz, 5260MHz-5320MHz,5500MHz-5700MHz, 5745MHz-5825MHz IEEE 802.11ac HT40: 5190MHz-5230MHz, 5270MHz-5310MHz, 5510MHz-5670MHz, 5755MHz-5755MHz IEEE 802.11ac HT80: 5210MHz, 5290MHz, 5530MHz,5610MHz, 5775MHz IEEE 802.11ax HT20: 5180MHz-5240MHz, 5260MHz-5320MHz,5500MHz-5700MHz, 5745MHz-5825MHz IEEE 802.11ax HT40: 5190MHz-5230MHz, 5270MHz-5310MH…

Text truncated - open the document above for the full version.

Test Report

Antenna Name Mercku M6P Model M6P Manufacturer Mercku Technology (China), Inc. Address Block B1, Southern Software Park No.1 Software Road, Tangjia Zhuhai, Guangdong, China Frequency Band 2.4GHz-5.9GHz Antenna Type Dedicated antenna Unit: mm 42 48 72 19 6 10 1、 VSWR 2、 Gain 频率(GHz) 2.4 2.5 5.1 5.5 5.9 增益(dBi) 3.9 3.9 6.7 6.5 7.0 3、 Radiation pattern 3D patterns @2.4GHz 3D patterns @5.9GHz

Test Report

Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 1 of 173 FCC AND ISED CERTIFICATION TEST REPORT FOR Issued By: Dongguan Dongdian Testing Service Co., Ltd. Add.: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City, Guangdong Province, China, 523808 Tel.: +86-0769-38826678, E-mail: [email protected], http://www.dgddt.com Applicant : Mercku Inc. Address : 3600 Steeles Avenue East, Suite C108B, Markham, Ontario, L3R 9Z7, Canada Equipment under Test : M6a Plus Mesh Wi-Fi Router Model No. : M6a Plus Trade Mark : MERCKU FCC ID : 2APR4-M6P IC : 23877-M6P Manufacturer : Mercku Technology (China), Inc. Address : Block B1, Southern Software Park No.1 Software Road, Tangjia Zhuhai, Guangdong, China Report No.: DDT-R22100908-2E01 Issued Date: Nov. 22, 2022 Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 2 of 173 Table of Contents Test report declares.......................................................................................................4 1. Summary of Test Results ............................................................................................... 6 2. General Test Information ............................................................................................... 7 2.1. Description of EUT ......................................................................................................... 7 2.2. Accessories of EUT ........................................................................................................ 8 2.3. Assistant equipment used for test .................................................................................. 8 2.4. Block diagram of EUT configuration for test .................................................................. 8 2.5. Deviations of test standard............................................................................................. 9 2.6. Test environment conditions .......................................................................................... 9 2.7. Test laboratory ............................................................................................................... 9 2.8. Measurement uncertainty ............................................................................................. 10 3. Equipment Used During Test ....................................................................................... 11 4. 6 dB Bandwidth and 99% Bandwidth ........................................................................... 12 4.1. Block diagram of test setup .......................................................................................... 12 4.2. Limits ............................................................................................................................ 12 4.3. Test procedure ............................................................................................................. 12 4.4. Test result ..................................................................................................................... 13 4.5. Original test data .......................................................................................................... 15 5. Conducted Peak Output Power ................................................................................... 40 5.1. Block diagram of test setup .......................................................................................... 40 5.2. Limits ............................................................................................................................ 40 5.3. Test procedure ............................................................................................................. 40 5.4. Test result ..................................................................................................................... 41 6. Power Spectral Density ................................................................................................ 43 6.1. Block diagram of test setup .......................................................................................... 43 6.2. Limits ............................................................................................................................ 43 6.3. Test procedure ............................................................................................................. 43 6.4. Test result ..................................................................................................................... 44 6.5. Original test data .......................................................................................................... 45 7. Band Edge Compliance (Conducted Method) ............................................................. 58 7.1. Block diagram of test setup .......................................................................................... 58 7.2. Limits ............................................................................................................................ 58 7.3. Test procedure ............................................................................................................. 58 7.4. Test result ..................................................................................................................... 59 7.5. original test data ........................................................................................................... 59 8. Radiated Spurious Emissions ...................................................................................... 68 8.1. Block diagram of test setup .......................................................................................... 68 Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 3 of 173 8.2. Limit .............................................................................................................................. 69 8.3. Test procedure .....................................................…

Text truncated - open the document above for the full version.

Test Report

Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 37 of 173 11AX20MIMO_Ant2_2462 11AX40MIMO_Ant1_2422 11AX40MIMO_Ant2_2422 Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 38 of 173 11AX40MIMO_Ant1_2437 11AX40MIMO_Ant2_2437 11AX40MIMO_Ant1_2452 Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 39 of 173 11AX40MIMO_Ant2_2452 Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 40 of 173 5. Conducted Peak Output Power 5.1. Block diagram of test setup Same as section 4.1 5.2. Limits For systems using digital modulation in the 902 - 928 MHz, 2400 - 2483.5 MHz, and 5725 - 5850 MHz bands: 1 Watt. If transmitting antennas of directional gain greater than 6 dBi are used, the conducted output power from the intentional radiator shall be reduced below the stated values as appropriate, by the amount in dB that the directional gain of the antenna exceeds 6 dBi. 5.3. Test procedure Connect each EUT’s antenna output to power sensor by RF cable and attenuator Measure the PK output power of each antenna port by power sensor Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 41 of 173 5.4. Test result Test Mode Test Channel Ant Conducted Peak Output Power [dBm] Conducted Limit [dBm] EIRP [dBm] EIRP Limit [dBm] Verdict 11B 2412 ANT1 13.76 30 17.66 36 Pass 11B 2412 ANT2 13.42 30 17.32 36 Pass 11B 2437 ANT1 13.27 30 17.17 36 Pass 11B 2437 ANT2 13.92 30 17.82 36 Pass 11B 2462 ANT1 14.00 30 17.90 36 Pass 11B 2462 ANT2 13.76 30 17.66 36 Pass 11G 2412 ANT1 15.56 30 19.46 36 Pass 11G 2412 ANT2 14.85 30 18.75 36 Pass 11G 2437 ANT1 15.01 30 18.91 36 Pass 11G 2437 ANT2 15.29 30 19.19 36 Pass 11G 2462 ANT1 15.91 30 19.81 36 Pass 11G 2462 ANT2 15.23 30 19.13 36 Pass 11N20MIMO 2412 ANT1 11.49 30 15.39 36 Pass 11N20MIMO 2412 ANT2 10.57 30 14.47 36 Pass 11N20MIMO 2412 ANT1+2 14.06 29.09 20.97 36 Pass 11N20MIMO 2437 ANT1 10.98 30 14.88 36 Pass 11N20MIMO 2437 ANT2 11.10 30 15.00 36 Pass 11N20MIMO 2437 ANT1+2 14.05 29.09 20.96 36 Pass 11N20MIMO 2462 ANT1 11.84 30 15.74 36 Pass 11N20MIMO 2462 ANT2 11.14 30 15.04 36 Pass 11N20MIMO 2462 ANT1+2 14.51 29.09 21.42 36 Pass 11N40MIMO 2422 ANT1 11.50 30 15.40 36 Pass 11N40MIMO 2422 ANT2 10.67 30 14.57 36 Pass 11N40MIMO 2422 ANT1+2 14.12 29.09 21.03 36 Pass 11N40MIMO 2437 ANT1 10.90 30 14.80 36 Pass 11N40MIMO 2437 ANT2 11.13 30 15.03 36 Pass 11N40MIMO 2437 ANT1+2 14.03 29.09 20.94 36 Pass 11N40MIMO 2452 ANT1 10.86 30 14.76 36 Pass 11N40MIMO 2452 ANT2 11.09 30 14.99 36 Pass 11N40MIMO 2452 ANT1+2 13.99 29.09 20.90 36 Pass 11AX20MIMO 2412 ANT1 11.80 30 15.70 36 Pass 11AX20MIMO 2412 ANT2 10.89 30 14.79 36 Pass 11AX20MIMO 2412 ANT1+2 14.38 29.09 21.29 36 Pass 11AX20MIMO 2437 ANT1 11.22 30 15.12 36 Pass Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 42 of 173 11AX20MIMO 2437 ANT2 11.35 30 15.25 36 Pass 11AX20MIMO 2437 ANT1+2 14.30 29.09 21.21 36 Pass 11AX20MIMO 2462 ANT1 12.11 30 16.01 36 Pass 11AX20MIMO 2462 ANT2 11.36 30 15.26 36 Pass 11AX20MIMO 2462 ANT1+2 14.76 29.09 21.67 36 Pass 11AX40MIMO 2422 ANT1 10.68 30 14.58 36 Pass 11AX40MIMO 2422 ANT2 9.77 30 13.67 36 Pass 11AX40MIMO 2422 ANT1+2 13.26 29.09 20.17 36 Pass 11AX40MIMO 2437 ANT1 10.12 30 14.02 36 Pass 11AX40MIMO 2437 ANT2 10.28 30 14.18 36 Pass 11AX40MIMO 2437 ANT1+2 13.21 29.09 20.12 36 Pass 11AX40MIMO 2452 ANT1 10.09 30 13.99 36 Pass 11AX40MIMO 2452 ANT2 10.23 30 14.13 36 Pass 11AX40MIMO 2452 ANT1+2 13.17 29.09 20.08 36 Pass Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 43 of 173 6. Power Spectral Density 6.1. Block diagram of test setup Same as section 4.1 6.2. Limits For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous transmission. 6.3. Test procedure (1) Connect EUT’s antenna output to spectrum analyzer by RF cable. (2) Set the spectrum analyzer as follows: Center frequency DTS Channel center frequency RBW: 3 kHz ≤ RBW ≤ 100 kHz VBW: ≥ 3RBW Span 1.5 times the DTS bandwidth Detector Mode: Peak Sweep time: auto Trace mode Max hold (3) Allow the trace to stabilize, use the peak marker function to determine the maximum amplitude level within the RBW. (4) If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat. Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 44 of 173 6.4. Test result Test Mode Antenna Channel [MHz] Result [dBm/ 3 kHz] Limit [dBm/ 3 kHz] Verdict 11B ANT1 2412 -7.38 8 Pass 11B ANT2 2412 -7.66 8 Pass 11B ANT1 2437 -7.02 8 Pass 11B ANT2 2437 -7.55 8 Pass 11B ANT1 2462 -7.39 8 Pass 11B ANT2 2462 -6.81 8 Pass 11G ANT1 2412 -8.13 8 Pass 11G ANT2 2412 -9.12 8 Pass 11G ANT1 2437 -7.69 8 Pass 11G ANT2 2437 -8.51 8 Pass 11G ANT1 2462 -6.96 8 Pass 11G ANT2 2462 -7.95 8 Pass 11N20MIMO ANT1 2412 -12.49 8 Pass 11N20MIMO ANT2 2412 -13.1 8 Pass 11N20MIMO ANT1+2 2412 -9.77 7.09 Pass 11N20MIMO ANT1 2437 -13.19 8 Pass 11N20MIMO ANT2 2437 -13.11 8 Pass 11N20MIMO ANT1+2 2437 -10.14 7.09 Pass 11N20MIMO ANT1 2462 -12.42 8 Pass 11N20MIMO ANT2 2462 -12.82 8 Pass 11N20MIMO ANT1+2 2462 -9.61 7.09 Pass 11N40MIMO ANT1 2422 -14.4 8 Pass 11N40MIMO ANT2 2422 -15.9 8 Pass 11N40MIMO ANT1+2 2422 -12.08 7.09 Pass 11N40MIMO ANT1 2437 -16.96 8 Pass 11N40MIMO ANT2 2437 -16.09 8 Pass 11N40MIMO ANT1+2 2437 -13.49 7.09 Pass 11N40MIMO ANT1 2452 -16 8 Pass 11N40MIMO ANT2 2452 -15.16 8 Pass 11N40MIMO ANT1+2 2452 -12.55 7.09 Pass 11AX20MIMO ANT1 2412 -14.05 8 Pass 11AX20MIMO ANT2 2412 -14.89 8 Pass 11AX20MIMO ANT1+2 2412 -11.44 7.09 Pass 11AX20MIMO ANT1 2437 -13.68 8 Pass 11AX20MIMO ANT2 2437 -14.35 8 Pass 11AX20MIMO ANT1+2 2437 -10.99 7.09 Pass 11AX20MIMO ANT1 2462 -12.26 8 Pass 11AX20MIMO ANT2 2462 -12.41 8 Pass 11AX20MIMO ANT1+2 2462 -9.32 7.09 Pass 11AX40MIMO ANT1 2422 -17.77 8 Pass 11AX40MIMO ANT2 2422 -19.03 8 Pass 11AX40MIMO ANT1+2 2422 -15.34 7.09…

Text truncated - open the document above for the full version.

Test Report

Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 74 of 173 TR-4-E-009 Radiated Emission Test Result Test Date: 2022-10-25 Tested By: Bairong EUT: M6a Plus Mesh Wi-Fi Router Model Number: M6a Plus Test Mode: Tx Mode Power Supply: AC 120V/60Hz Condition: Temp:23.4°C;Humi:61.4%;Press:100.3kPa Test Site: DDT 3# Chamber File Path: d:\ts\2022 report data\Q22100908-2E M6a Plus\FCC BELOW 1G\20221025-084923_V Memo: 2.4GWIFI Final Data List NO. Freq. [MHz] Reading [dBμV/m] Factor [dB] Result [dBμV/m] Limit [dBμV/m] Margin [dB] Detector Polarity 1 37.74 40.92 -13.26 27.66 40.00 12.34 QP Vertical 2 54.82 42.87 -12.26 30.61 40.00 9.39 QP Vertical 3 112.45 36.86 -8.56 28.30 43.50 15.20 QP Vertical 4 153.08 37.46 -11.20 26.26 43.50 17.24 QP Vertical 5 374.81 36.02 -3.81 32.21 46.00 13.79 QP Vertical 6 873.77 28.16 6.23 34.39 46.00 11.61 QP Vertical Note: 1. Result Level = Read Level + Factor 2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit. 3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto. Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 75 of 173 Radiated Emission test (above 1 GHz) TR-4-E-009 Radiated Emission Test Result Test Date: 2022-10-30 Tested By: Bairong EUT: M6a Plus Mesh Wi-Fi Router Model Number: M6a Plus Test Mode: Tx Mode Power Supply: 120V/60Hz Condition: Temp:23.9°C;Humi:54.4%;Press:100.3kPa Test Site: DDT 3# Chamber File Path: d:\ts\2022 report data\Q22100908-2E M6A plus\FCC ABOVE 1G 2.4G\1 Memo: 11g 2412 Test Graph Suspected Data List NO. Freq. [MHz] Reading [dBμV] Factor [dB] Level [dBμV/m] Limit [dBμV/m] Margin [dB] Detector Polarity 1 1202.54 49.96 -10.93 39.03 74.00 34.97 PK Horizontal 2 1278.42 50.08 -10.97 39.11 74.00 34.89 PK Horizontal 3 1576.87 50.26 -11.48 38.78 74.00 35.22 PK Horizontal 4 1799.64 49.98 -11.58 38.40 74.00 35.60 PK Horizontal 5 2261.86 49.42 -9.91 39.51 74.00 34.49 PK Horizontal 6 2824.73 50.69 -8.54 42.15 74.00 31.85 PK Horizontal Note: 1. Level = Reading + Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 76 of 173 TR-4-E-009 Radiated Emission Test Result Test Date: 2022-10-30 Tested By: Bairong EUT: M6a Plus Mesh Wi-Fi Router Model Number: M6a Plus Test Mode: Tx Mode Power Supply: 120V/60Hz Condition: Temp:23.9°C;Humi:54.4%;Press:100.3kPa Test Site: DDT 3# Chamber File Path: d:\ts\2022 report data\Q22100908-2E M6A plus\FCC ABOVE 1G 2.4G\2 Memo: 11g 2412 Test Graph Suspected Data List NO. Freq. [MHz] Reading [dBμV] Factor [dB] Level [dBμV/m] Limit [dBμV/m] Margin [dB] Detector Polarity 1 1141.15 49.28 -10.90 38.38 74.00 35.62 PK Vertical 2 1248.99 49.52 -10.89 38.63 74.00 35.37 PK Vertical 3 1474.66 49.77 -11.23 38.54 74.00 35.46 PK Vertical 4 1782.92 49.30 -11.59 37.71 74.00 36.29 PK Vertical 5 2214.90 50.21 -9.99 40.22 74.00 33.78 PK Vertical 6 2688.79 51.17 -8.87 42.30 74.00 31.70 PK Vertical Note: 1. Level = Reading + Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 77 of 173 TR-4-E-009 Radiated Emission Test Result Test Date: 2022-10-30 Tested By: Bairong EUT: M6a Plus Mesh Wi-Fi Router Model Number: M6a Plus Test Mode: Tx Mode Power Supply: 120V/60Hz Condition: Temp:23.9°C;Humi:54.4%;Press:100.3kPa Test Site: DDT 3# Chamber File Path: d:\ts\2022 report data\Q22100908-2E M6A plus\FCC ABOVE 1G 2.4G\3 Memo: 11g 2412 Test Graph Suspected Data List NO. Freq. [MHz] Reading [dBμV] Factor [dB] Level [dBμV/m] Limit [dBμV/m] Margin [dB] Detector Polarity 1 4813.43 51.13 -5.43 45.70 74.00 28.30 PK Horizontal 2 7235.47 51.02 -0.70 50.32 74.00 23.68 PK Horizontal 3 8863.85 44.79 2.57 47.36 74.00 26.64 PK Horizontal 4 11989.62 44.25 4.95 49.20 74.00 24.80 PK Horizontal 5 13542.99 43.56 5.75 49.31 74.00 24.69 PK Horizontal 6 14554.36 42.61 6.09 48.70 74.00 25.30 PK Horizontal Note: 1. Level = Reading + Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 78 of 173 TR-4-E-009 Radiated Emission Test Result Test Date: 2022-10-30 Tested By: Bairong EUT: M6a Plus Mesh Wi-Fi Router Model Number: M6a Plus Test Mode: Tx Mode Power Supply: 120V/60Hz Condition: Temp:23.9°C;Humi:54.4%;Press:100.3kPa Test Site: DDT 3# Chamber File Path: d:\ts\2022 report data\Q22100908-2E M6A plus\FCC ABOVE 1G 2.4G\4 Memo: 11g 2412 Test Graph Suspected Data List NO. Freq. [MHz] Reading [dBμV] Factor [dB] Level [dBμV/m] Limit [dBμV/m] Margin [dB] Detector Polarity 1 3599.58 48.69 -8.26 40.43 74.00 33.57 PK Vertical 2 4821.20 55.54 -5.39 50.15 74.00 23.85 PK Vertical 3 7227.69 48.76 -0.70 48.06 74.00 25.94 PK Vertical 4 9651.19 45.25 2.39 47.64 74.00 26.36 PK Vertical 5 13087.40 44.10 5.20 49.30 74.00 24.70 PK Vertical 6 14339.53 42.62 6.20 48.82 74.00 25.18 PK Vertical Note: 1. Level = Reading + Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 79 of 173 TR-4-E-009 Radiated Emission Test Result Test Date: 2022-10-30 Tested By: Bairong EUT: M6a Plus Mesh Wi-Fi Router Model Number: M6a Plus Test Mode: Tx Mode Power Supply: 120V/60Hz Condition: Temp:23.9°C;Humi:54.4%;Press:100.3kPa Test Site: DDT 3# Chamber File Path: d:\ts\2022 report data\Q22100908-2E M6A plus\FCC ABOVE 1G 2.4G\5 Memo: 11g 2437 Test Graph Suspected Data List NO. Freq. [MHz] Reading [dBμV] Factor [dB] Level [dBμV/m] Limit [dBμV/m] Margin [dB] Detector Polarity 1 1158.71 49.58 -10.90 38.68 74.00 35.32 PK Horizontal 2…

Text truncated - open the document above for the full version.

Test Report

Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 108 of 173 11N40MIMO_Ant2_2422_1000~26500 11N40MIMO_Ant1_2437_0~Reference 11N40MIMO_Ant1_2437_30~1000 Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R22100908-2E01 Page 109 of 173 11N40MIMO_Ant1_2437_1000~26500 11N40MIMO_Ant2_2437_0~Reference 11N40MIMO_Ant2_2437_30~1000 Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R2210…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Shi Ge
[email protected]+86 15210895289Fax: /

Technical Contact

Dongguan Dongdian Testing Service Co., LtdDamon Hu
[email protected]86-0769- 38826678

Dongguan · China

Non-Technical Contact

Dongguan Dongdian Testing Service Co., LtdDamon Hu
[email protected]86-0769- 38826678

Test Firm

Guangdong Dongdian Testing Service Co., Ltd.Mr. Jamy Yu
[email protected]+86-0769-89201646

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz39.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. Device is a 802.11 b/g/n/ax device 2x2 MIMO configuration as described in this filing.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance. The device contains 20MHz and 40MHz.

Other Applications from Mercku Inc.

Mercku 5G CPE X6 - FCC ID 2APR4-X6 - Mercku Inc.
2APR4-X6

Mercku 5G CPE X6

Jul 31, 2023

Equipment Class

DTS - Digital Transmission System
M6 Mesh Wi-Fi Router - FCC ID 2APR4-M6 - Mercku Inc.
2APR4-M6

M6 Mesh Wi-Fi Router

Feb 07, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX