FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. CHEP/
  3. 2APRD-GEN4WIDE

2APRD-GEN4WIDEAsset Tracker

CHEP

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Jan 05, 2026
Application Purpose
Original Equipment
Equipment Note
Asset Tracker
Frequency Range
663.10000000 - 697.90000000
Company
CHEP
Country
United States

Documents & Files

Select a file to view

Attestation Statements

β†—
β†—

Cover Letter(s)

β†—
β†—
β†—
β†—
β†—

ID Label/Location Info

β†—
β†—
β†—

RF Exposure Info

β†—

Test Report

β†—
β†—
β†—
β†—
β†—
β†—
β†—
β†—
β†—
β†—
β†—
β†—
β†—
β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Test Report

Sporton International Inc. (ShenZhen) Page Number : 1 of 27 TEL : +86-755-8637-9589 Report Issued Date : Dec. 22, 2025 FAX : +86-755-8637-9595 Report Version : Rev. 01 FCC ID : 2APRD-GEN4WIDE Report Template No.: BU5-FGLTE Version 2.0 FCC RF Test Report Report No. : FG5O2210B FCC RF Test Report APPLICANT : CHEP EQUIPMENT : Asset Tracker BRAND NAME : CHEP MODEL NAME : Gen 4 Ultra Wide, Gen 4 Ultra Wide QP FCC ID : 2APRD-GEN4WIDE STANDARD : 47 CFR Part 22(H), 24(E), 27(L), 27(H), 27(F), 27(N) CLASSIFICATION : PCS Licensed Transmitter (PCB) TEST DATE(S) : Nov. 20, 2025 ~ Dec. 18, 2025 This product installed a RF module (Brand Name: Quectel, Model Name: BG95-M3, FCC ID: XMR201910BG95M3) during the test, only Conducted Power, ERP/EIRP and RSE test items are tested in this report, all the other test results are leveraged from module RF report. We, Sporton International Inc. (ShenZhen), would like to declare that the tested sample has been evaluated in accordance with the procedures given in ANSI C63.26-2015 and shown compliance with the applicable technical standards. The test results in this report apply exclusively to the tested model / sample. Without written approval of Sporton International Inc. (ShenZhen), the test report shall not be reproduced except in full. Approved by: Fly Liang Sporton International Inc. (ShenZhen) 1/F, 2/F, Bldg 5, Shiling Industrial Zone, Xinwei Village, Xili, Nanshan, Shenzhen, 518055 People’s Republic of China Sporton International Inc. (ShenZhen) Page Number : 2 of 27 TEL : +86-755-8637-9589 Report Issued Date : Dec. 22, 2025 FAX : +86-755-8637-9595 Report Version : Rev. 01 FCC ID : 2APRD-GEN4WIDE Report Template No.: BU5-FGLTE Version 2.0 FCC RF Test Report Report No. : FG5O2210B TABLE OF CONTENTS REVISION HISTORY .......................................................................................................................................... 3 SUMMARY OF TEST RESULT ......................................................................................................................... 4 1 GENERAL DESCRIPTION .......................................................................................................................... 5 1.1 Applicant ............................................................................................................................................ 5 1.2 Manufacturer ...................................................................................................................................... 5 1.3 Product Feature of Equipment Under Test ........................................................................................ 5 1.4 Product Specification of Equipment Under Test ................................................................................ 5 1.5 Modification of EUT ........................................................................................................................... 7 1.6 Maximum ERP/EIRP ......................................................................................................................... 7 1.7 Testing Location .............................................................................................................................. 10 1.8 Test Software ................................................................................................................................... 10 1.9 Applicable Standards ....................................................................................................................... 11 2 TEST CONFIGURATION OF EQUIPMENT UNDER TEST ...................................................................... 12 2.1 Test Mode ........................................................................................................................................ 12 2.2 Connection Diagram of Test System ............................................................................................... 14 2.3 Support Unit used in test configuration and system ........................................................................ 14 2.4 Frequency List of Low/Middle/High Channels ................................................................................. 15 3 CONDUCTED TEST ITEMS ...................................................................................................................... 21 3.1 Measuring Instruments .................................................................................................................... 21 3.2 Test Setup ....................................................................................................................................... 21 3.3 Test Result of Conducted Test ........................................................................................................ 21 3.4 Conducted Output Power and ERP/EIRP ....................................................................................... 22 4 RADIATED TEST ITEMS .......................................................................................................................... 23 4.1 Measuring Instruments .................................................................................................................... 23 4.2 Test Setup ....................................................................................................................................... 23 4.3 Test Result of Radiated Test ........................................................................................................... 24 4.4 Radiated Spurious Emission ........................................................................................................... 25 5 LIST OF MEASURING EQUIPMENT ........................................................................................................ 26 6 MEASUREMENT UNCERTAINTY ............................................................................................................ 27 APPENDIX A. TEST RESULTS OF CONDUCTED TEST APPENDIX B. TEST RESUL…

Text truncated - open the document above for the full version.

Test Report

RF TEST REPORT Applicant Quectel Wireless Solutions Co., Ltd FCC ID XMR201910BG95M3 Product LTE Cat M1 & Cat NB2 & EGPRS Module Brand Quectel Model BG95-M3 Report No. R1907A0446-R9 Issue Date September 12, 2019 TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC CFR47 Part 2 (2018)/ FCC CFR 47 Part 22H (2018). The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Performed by: Peng Tao Approved by: Kai Xu TA Technology (Shanghai) Co., Ltd. No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China TEL: +86‐021‐50791141/2/3 FAX: +86‐021‐50791141/2/3‐8000 RF Test Report Report No.: R1907A0446-R9 TA Technology (Shanghai) Co., Ltd. TA-MB-05-001R Page 2 of 35 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENT 1. Test Laboratory ...................................................................................................................................... 4 1.1. Notes of the Test Report ............................................................................................................... 4 1.2. Test facility ..................................................................................................................................... 4 1.3. Testing Location ............................................................................................................................ 5 2. General Description of Equipment under Test ....................................................................................... 6 3. Applied Standards .................................................................................................................................. 7 4. Test Configuration .................................................................................................................................. 8 5. Test Case Results .................................................................................................................................. 9 5.1. RF Power Output ........................................................................................................................... 9 5.2. Effective Radiated Power ............................................................................................................ 11 5.3. Occupied Bandwidth ................................................................................................................... 14 5.4. Band Edge Compliance ............................................................................................................... 19 5.5. Peak-to-Average Power Ratio (PAPR) ....................................................................................... 22 5.6. Frequency Stability ...................................................................................................................... 24 5.7. Spurious Emissions at Antenna Terminals ................................................................................. 28 5.8. Radiates Spurious Emission ....................................................................................................... 30 6. Main Test Instruments ......................................................................................................................... 35 RF Test Report Report No.: R1907A0446-R9 TA Technology (Shanghai) Co., Ltd. TA-MB-05-001R Page 3 of 35 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Summary of measurement results No. Test Case Clause in FCC rules Verdict 1 RF power output 2.1046 PASS 2 Effective Radiated Power 22.913(a)(5) PASS 3 Occupied Bandwidth 2.1049 PASS 4 Band Edge Compliance 2.1051 / 22.917(a) PASS 5 Peak-to-Average Power Ratio 22.913(d)/ KDB 971168 D01(5.7) PASS 6 Frequency Stability 2.1055 / 22.355 PASS 7 Spurious Emissions at Antenna Terminals 2.1051 / 22.917(a) PASS 8 Radiates Spurious Emission 2.1053 / 22.917 (a) PASS Note: PASS: The EUT complies with the essential requirements in the standard. FAIL: The EUT does not comply with the essential requirements in the standard. Date of Testing: August 20, 2019 ~ September 11, 2019 RF Test Report Report No.: R1907A0446-R9 TA Technology (Shanghai) Co., Ltd. TA-MB-05-001R Page 4 of 35 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1. Test Laboratory 1.1. Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA technology (shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein .Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2. Test facility FCC (Designation number: CN1179, Test Firm Registration Number: 446626) TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. IC (recognition number is 8510A) TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic emission measurement. VCCI (recognition number is C-4595, T-2154, R-4113, G-10766) TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic emission measurement. A2LA (Certificate Number: 3857.01) TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory Accreditation to perform electromagnetic emission measurement. RF Test Report Report No.: R1907A0446-R9 TA Technology (Shanghai) Co., Ltd. TA-MB-05-001R Page 5 of 35 This report shall not be reproduced except in full, without the …

Text truncated - open the document above for the full version.

Test Report

RF TEST REPORT Applicant Quectel Wireless Solutions Co., Ltd FCC ID XMR201910BG95M3 Product LTE Cat M1 & Cat NB2 & EGPRS Module Brand Quectel Model BG95-M3 Report No. R1907A0446-R8 Issue Date September 12, 2019 TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC CFR47 Part 2 (2018)/ FCC CFR 47 Part 90S (2018). The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Performed by: Peng Tao Approved by: Kai Xu TA Technology (Shanghai) Co., Ltd. No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China TEL: +86‐021‐50791141/2/3 FAX: +86‐021‐50791141/2/3‐8000 RF Test Report Report No.: R1907A0446-R8 TA Technology (Shanghai) Co., Ltd. TA-MB-04-010R Page 2 of 37 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENT 1. Test Laboratory ...................................................................................................................................... 4 1.1. Notes of the Test Report ............................................................................................................... 4 1.2. Test facility ..................................................................................................................................... 4 1.3. Testing Location ............................................................................................................................ 5 2. General Description of Equipment under Test ....................................................................................... 6 3. Applied Standards .................................................................................................................................. 7 4. Test Configuration .................................................................................................................................. 8 5. Test Case Results .................................................................................................................................. 9 5.1. RF Power Output ........................................................................................................................... 9 5.2. Effective Radiated Power ............................................................................................................ 11 5.3. Occupied Bandwidth ................................................................................................................... 14 5.4. Emission Mask ............................................................................................................................ 18 5.5. Peak-to-Average Power Ratio (PAPR) ....................................................................................... 22 5.6. Frequency Stability ...................................................................................................................... 24 5.7. Spurious Emissions at Antenna Terminals ................................................................................. 27 5.8. Radiates Spurious Emission ....................................................................................................... 32 6. Main Test Instruments ......................................................................................................................... 37 RF Test Report Report No.: R1907A0446-R8 TA Technology (Shanghai) Co., Ltd. TA-MB-04-010R Page 3 of 37 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Summary of measurement results No. Test Case Clause in FCC rules Verdict 1 RF power output 2.1046/90.635(b) PASS 2 Effective Radiated Power 90.635(b) PASS 3 Occupied Bandwidth 2.1049/ 90.209 PASS 4 Emission Masks 2.1051 / 90.691 PASS 5 Peak-to-Average Power Ratio KDB 971168 D01(5.7) PASS 6 Frequency Stability 2.1055 / 90.213 PASS 7 Spurious Emissions at Antenna Terminals 2.1051 / 90.691 PASS 8 Radiates Spurious Emission 2.1053 /90.691 PASS Note: PASS: The EUT complies with the essential requirements in the standard. FAIL: The EUT does not comply with the essential requirements in the standard. Date of Testing: August 20, 2019 ~ September 11, 2019 RF Test Report Report No.: R1907A0446-R8 TA Technology (Shanghai) Co., Ltd. TA-MB-04-010R Page 4 of 37 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1. Test Laboratory 1.1. Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA technology (shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein .Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2. Test facility FCC (Designation number: CN1179, Test Firm Registration Number: 446626) TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. IC (recognition number is 8510A) TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic emission measurement. VCCI (recognition number is C-4595, T-2154, R-4113, G-10766) TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic emission measurement. A2LA (Certificate Number: 3857.01) TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory Accreditation to perform electromagnetic emission measurement. RF Test Report Report No.: R1907A0446-R8 TA Technology (Shanghai) Co., Ltd. TA-MB-04-010R Page 5 of 37 This report shall not be reproduced except in full, without the written…

Text truncated - open the document above for the full version.

Test Report

RF TEST REPORT Applicant Quectel Wireless Solutions Co., Ltd FCC ID XMR201910BG95M3 Product LTE Cat M1 & Cat NB2 & EGPRS Module Brand Quectel Model BG95-M3 Report No. R1907A0446-R7 Issue Date September 12, 2019 TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC CFR47 Part 2 (2018)/ FCC CFR 47 Part 22H (2018). The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Performed by: Peng Tao Approved by: Kai Xu TA Technology (Shanghai) Co., Ltd. No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China TEL: +86‐021‐50791141/2/3 FAX: +86‐021‐50791141/2/3‐8000 RF Test Report Report No.: R1907A0446-R7 TA Technology (Shanghai) Co., Ltd. TA-MB-05-001R Page 2 of 42 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENT 1. Test Laboratory ...................................................................................................................................... 4 1.1. Notes of the Test Report ............................................................................................................... 4 1.2. Test facility ..................................................................................................................................... 4 1.3. Testing Location ............................................................................................................................ 5 2. General Description of Equipment under Test ....................................................................................... 6 3. Applied Standards .................................................................................................................................. 7 4. Test Configuration .................................................................................................................................. 8 5. Test Case Results .................................................................................................................................. 9 5.1. RF Power Output ........................................................................................................................... 9 5.2. Effective Radiated Power ............................................................................................................ 11 5.3. Occupied Bandwidth ................................................................................................................... 14 5.4. Band Edge Compliance ............................................................................................................... 18 5.5. Peak-to-Average Power Ratio (PAPR) ....................................................................................... 26 5.6. Frequency Stability ...................................................................................................................... 28 5.7. Spurious Emissions at Antenna Terminals ................................................................................. 31 5.8. Radiates Spurious Emission ....................................................................................................... 37 6. Main Test Instruments ......................................................................................................................... 42 RF Test Report Report No.: R1907A0446-R7 TA Technology (Shanghai) Co., Ltd. TA-MB-05-001R Page 3 of 42 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Summary of measurement results No. Test Case Clause in FCC rules Verdict 1 RF power output 2.1046 PASS 2 Effective Radiated Power 22.913(a)(5) PASS 3 Occupied Bandwidth 2.1049 PASS 4 Band Edge Compliance 2.1051 / 22.917(a) PASS 5 Peak-to-Average Power Ratio 22.913(d)/ KDB 971168 D01(5.7) PASS 6 Frequency Stability 2.1055 / 22.355 PASS 7 Spurious Emissions at Antenna Terminals 2.1051 / 22.917(a) PASS 8 Radiates Spurious Emission 2.1053 / 22.917 (a) PASS Note: PASS: The EUT complies with the essential requirements in the standard. FAIL: The EUT does not comply with the essential requirements in the standard. Date of Testing: August 20, 2019 ~ September 11, 2019 RF Test Report Report No.: R1907A0446-R7 TA Technology (Shanghai) Co., Ltd. TA-MB-05-001R Page 4 of 42 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1. Test Laboratory 1.1. Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA technology (shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein .Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2. Test facility FCC (Designation number: CN1179, Test Firm Registration Number: 446626) TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. IC (recognition number is 8510A) TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic emission measurement. VCCI (recognition number is C-4595, T-2154, R-4113, G-10766) TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic emission measurement. A2LA (Certificate Number: 3857.01) TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory Accreditation to perform electromagnetic emission measurement. RF Test Report Report No.: R1907A0446-R7 TA Technology (Shanghai) Co., Ltd. TA-MB-05-001R Page 5 of 42 This report shall not be reproduced except in full, without the …

Text truncated - open the document above for the full version.

Test Report

RF Test Report Report No.: R1907A0446-R6V2 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 42 of 85 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. NB-IOT Band 13 BPSK 3.75kHz 1@0 CH-Low NB-IOT Band 13 BPSK 3.75kHz 1@47 CH-High NB-IOT Band 13 BPSK 15kHz 1@0 CH-Low NB-IOT Band 13 BPSK 15kHz 1@11 CH-High NB-IOT Band 13 QPSK 3.75kHz 1@0 CH-Low NB-IOT Band 13 QPSK 3.75kHz 1@47 CH-High RF Test Report Report No.: R1907A0446-R6V2 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 43 of 85 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. NB-IOT Band 13 QPSK 15kHz 1@0 CH-Low NB-IOT Band 13 QPSK 15kHz 1@11 CH-High NB-IOT Band 13 QPSK 15kHz 12@0 CH-LowNB-IOT Band 13 QPSK 15kHz 12@0 CH-High RF Test Report Report No.: R1907A0446-R6V2 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 44 of 85 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. NB-IOT Band 13 BPSK 3.75kHz (763MHz ~775MHz) NB-IOT Band 13 BPSK 3.75kHz (793MHz ~805MHz) NB-IOT Band 13 QPSK 3.75kHz (763MHz ~775MHz) NB-IOT Band 13 QPSK 3.75kHz (793MHz ~805MHz) RF Test Report Report No.: R1907A0446-R6V2 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 45 of 85 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. NB-IOT Band 13 BPSK 15kHz (763MHz ~775MHz) NB-IOT Band 13 BPSK 15kHz (793MHz ~805MHz) NB-IOT Band 13 QPSK 15kHz (763MHz ~775MHz) NB-IOT Band 13 QPSK 15kHz (793MHz ~805MHz) NB-IOT Band 13 QPSK 15kHz 12@0 (763MHz ~775MHz) NB-IOT Band 13 QPSK 15kHz 12@0 (793MHz ~805MHz) RF Test Report Report No.: R1907A0446-R6V2 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 46 of 85 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. NB-IOT Band 66 BPSK 3.75kHz 1@0 CH-Low NB-IOT Band 66 BPSK 3.75kHz 1@47 CH-High NB-IOT Band 66 BPSK 15kHz 1@0 CH-Low NB-IOT Band 66 BPSK 15kHz 1@11 CH-High NB-IOT Band 66 QPSK 3.75kHz 1@0 CH-Low NB-IOT Band 66 QPSK 3.75kHz 1@47 CH-High RF Test Report Report No.: R1907A0446-R6V2 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 47 of 85 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. NB-IOT Band 66 QPSK 15kHz 1@0 CH-Low NB-IOT Band 66 QPSK 15kHz 1@11 CH-High NB-IOT Band 66 QPSK 15kHz 12@0 CH-LowNB-IOT Band 66 QPSK 15kHz 12@0 CH-High RF Test Report Report No.: R1907A0446-R6V2 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 48 of 85 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. NB-IOT Band 71 BPSK 3.75kHz 1@0 CH-Low NB-IOT Band 71 BPSK 3.75kHz 1@47 CH-High NB-IOT Band 71 BPSK 15kHz 1@0 CH-Low NB-IOT Band 71 BPSK 15kHz 1@11 CH-High NB-IOT Band 71 QPSK 3.75kHz 1@0 CH-Low NB-IOT Band 71 QPSK 3.75kHz 1@47 CH-High RF Test Report Report No.: R1907A0446-R6V2 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 49 of 85 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. NB-IOT Band 71 QPSK 15kHz 1@0 CH-Low NB-IOT Band 71 QPSK 15kHz 1@11 CH-High NB-IOT Band 71 QPSK 15kHz 12@0 CH-LowNB-IOT Band 71 QPSK 15kHz 12@0 CH-High RF Test Report Report No.: R1907A0446-R6V2 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 50 of 85 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. NB-IOT Band 85 BPSK 3.75kHz 1@0 CH-Low NB-IOT Band 85 BPSK 3.75kHz 1@47 CH-High NB-IOT Band 85 BPSK 15kHz 1@0 CH-Low NB-IOT Band 85 BPSK 15kHz 1@11 CH-High NB-IOT Band 85 QPSK 3.75kHz 1@0 CH-Low NB-IOT Band 85 QPSK 3.75kHz 1@47 CH-High RF Test Report Report No.: R1907A0446-R6V2 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 51 of 85 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. NB-IOT Band 85 QPSK 15kHz 1@0 CH-Low NB-IOT Band 85 QPSK 15kHz 1@11 CH-High NB-IOT Band 85 QPSK 15kHz 12@0 CH-LowNB-IOT Band 85 QPSK 15kHz 12@0 CH-High RF Test Report Report No.: R1907A0446-R6V2 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 52 of 85 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 5.5 Peak-to-Average Power Ratio (PAPR) Ambient condition Temperature Relative humidity Pressure 23Β°C ~25Β°C 45%~50% 101.5kPa Methods of Measurement Measure the total peak power and record as PPk. And measure the total average power and record as PAvg. Both the peak and average power levels must be expressed in the same logarithmic units (e.g., dBm). Determine the PAPR from: PAPR (dB) = PPk (dBm) - PAvg (dBm). Test Setup Limits Rule Part 27.50(d)(5) Equipment employed must be authorized in accordance with the provisions of 24.51. Power measurements for transmissions by stations authorized under this section may be made either in accordance with a Commission-approved average power technique or in compliance with paragraph (d)(6) of this section. In measuring transmissions in this band using an average power technique, the peak-to-average ratio (PAR) of the transmission may not exceed 13 dB. Measurement Uncertainty The assessed measurement uncertainty to ensure 95% confidence level for thenormal distribution is with the coverage factor k = 2, U= 0.4 dB. RF Test Report Report No.: R1907A0446-R6V2 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 53 of 85 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Test Results Mode Modulation Sub-carrier spacing (KHz) Channel/ Frequency (MHz) Peak-to-Average Power Ratio (PAPR) Limit (dB) Conclusion Peak(dBm)Avg(dBm)PAPR(dB) Band 4 Standalone BPSK 3.75 20175/1732.521.82 18.00 3.82 ≀13 PASS QPSK …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Craig Constantino
[email protected]Fax: 4082036612

Technical Contact

CHEPCraig Constantino
[email protected]

2901 Tasman Drive Suite 107 Β· Santa Clara, 95054 Β· United States

Test Firm

Sporton International Inc. (Shenzhen)Johnny Chen
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
122H824.2 MHz - 848.8 MHz1.4158 W247KGXW2.5ppm
222H824.2 MHz - 848.8 MHz338.10 mW248KG7W2.5ppm
324E1.85 GHz - 1.91 GHz1.9275 W247KGXW2.5ppm
424E1.85 GHz - 1.91 GHz729.50 mW249KG7W2.5ppm
524E1.86 GHz - 1.90 GHz220.80 mW1M13G7D2.5ppm
624E1.86 GHz - 1.90 GHz204.60 mW965KW7D2.5ppm
724E1.85 GHz - 1.91 GHz220.80 mW927KW7D2.5ppm
824E1.85 GHz - 1.91 GHz243.20 mW184KG7D2.5ppm
924E1.86 GHz - 1.91 GHz133.70 mW1M12G7D2.5ppm
124E1.86 GHz - 1.91 GHz134.30 mW965KW7D2.5ppm
1124E1.85 GHz - 1.91 GHz160.70 mW185KG7D2.5ppm
12271.72 GHz - 1.75 GHz217.80 mW1M12G7D2.5ppm
13271.72 GHz - 1.75 GHz208.00 mW953KW7D2.5ppm
14271.72 GHz - 1.75 GHz218.30 mW1M12G7D2.5ppm
15271.71 GHz - 1.75 GHz217.30 mW951KW7D2.5ppm
16271.71 GHz - 1.75 GHz223.90 mW185KG7D2.5ppm
1722H829 MHz - 844 MHz92.00 mW1M12G7D2.5ppm
1822H829 MHz - 844 MHz94.40 mW963KW7D2.5ppm
1922H824.1 MHz - 848.9 MHz96.60 mW184KG7D2.5ppm
227704 MHz - 711 MHz73.50 mW1M12G7D2.5ppm
2127704 MHz - 711 MHz74.10 mW998KW7D2.5ppm
2227699.1 MHz - 715.9 MHz71.80 mW184KG7D2.5ppm
2327782 MHz - 782 MHz70.60 mW1M12G7D2.5ppm
2427782 MHz - 782 MHz71.60 mW963KW7D2.5ppm
2527777.1 MHz - 786.9 MHz75.50 mW185KG7D2.5ppm
2622H831.5 MHz - 841.5 MHz93.30 mW1M13G7D2.5ppm
2722H831.5 MHz - 841.5 MHz94.60 mW964KW7D2.5ppm
28271.72 GHz - 1.77 GHz222.80 mW1M13G7D2.5ppm
29271.72 GHz - 1.77 GHz213.80 mW968KW7D2.5ppm
3271.72 GHz - 1.77 GHz219.80 mW971KW7D2.5ppm
31271.71 GHz - 1.78 GHz209.90 mW185KG7D2.5ppm
3227663.1 MHz - 697.9 MHz74.80 mW184KG7D2.5ppm
3327703 MHz - 711 MHz61.40 mW1M12G7D2.5ppm
3427703 MHz - 711 MHz64.60 mW992KW7D2.5ppm
3527698.1 MHz - 715.9 MHz74.10 mW184KG7D2.5ppm
369819 MHz - 819 MHz91.20 mW1M13G7D2.5ppm
379819 MHz - 819 MHz93.30 mW965KW7D2.5ppm
Confidentiality
Long Term
Grant Notes
Output Power is EIRP and ERP for above and below 1 GHz, respectively, except for Part 90 operations, which are conducted. <br> The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. <br> This device supports LTE of 1.4, 3, 5, 10, 15 and 20 MHz bandwidth modes for LTE Bands 2, 4, 25, and 66; LTE of 1.4, 3, 5 and 10 MHz bandwidth modes for LTE Band 5 and 12; LTE of 5 and 10 MHz bandwidth modes for LTE Band 13 and 85; LTE of 1.4, 3, 5 10 and 15 MHz bandwidth modes for LTE Band 26. <br> This device contains functions that are not operational in the U.S. Territories. This filing is only applicable for U.S. operations.

Other Applications from CHEP

2APRD-ULTRAPULSE1

Asset Tracker

Jan 12, 2026

Equipment Class

DTS - Digital Transmission System
2APRD-GEN4SHORT

Asset Tracker

Sep 05, 2024

Equipment Class