FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Cudy Technology Co., Ltd./
  3. 2APRGRT01

2APRGRT01AX1800 Gigabit Dual Band Wi-Fi 6 Router

Shenzhen Cudy Technology Co., Ltd.
AX1800 Gigabit Dual Band Wi-Fi 6 Router - FCC ID 2APRGRT01 - Shenzhen Cudy Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 24, 2021
Application Purpose
Original Equipment
Date of Application
Aug 24, 2021
Equipment Note
AX1800 Gigabit Dual Band Wi-Fi 6 Router
Frequency Range
2412.00000000 - 2472.00000000
Company
Shenzhen Cudy Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

If your internet connection is through an ethernet cable directly from the wall instead of through a DSL/Cable/Satellite modem, connect the ethernet cable to the router’s WAN port, and skip steps 1, 2 ,3. Internet Power Socket Apague el módem y retire la batería si tiene una. Éteignez le modem et retirez la batterie s'il en a une. Turn off the modem, and remove the battery if it has one. Spegni il modem e rimuovi la batteria se ne ha una. Schalten Sie das Modem aus und entfernen Sie den Akku, falls vorhanden. 1 Turn on the modem and then wait about 2 minutes for it to restart. 2 Encienda el módem y luego espere unos 2 minutos para que se reinicie. Allumez le modem et attendez environ 2 minutes pour qu'il redémarre. Accendi il modem e attendi circa 2 minuti per riavviarlo. Schalten Sie das Modem ein und warten Sie ca. 2 Minuten, bis es neu gestartet wird. 3 Connect router’s INTERNET Port to DSL/Cable Modem/Ethernet. 2 Conecte el puerto INTERNET del enrutador a DSL / Cable Modem / Ethernet. Connectez le port INTERNET du routeur à DSL / modem câble / Ethernet. Collega la porta INTERNET del router a DSL / modem via cavo / Ethernet. Verbinden Sie den INTERNET-Port des Routers mit DSL / Kabelmodem / Ethernet. Connect the power adapter to the router, and wait 1 minute until the system LED changes from flash- ing to solid onred or blue, which means that the system startup is completed. Conecte el adaptador de alimentación al enrutador y espere 1 minuto hasta que el LED del sistema cambie de parpadeante a encendido (rojo o azul), lo que significa que el inicio del sistema se ha completado. Connectez l'adaptateur secteur au routeur et attendez 1 minute jusqu'à ce que le voyant du système passe de clignotant à fixe (rouge ou bleu), ce qui signifie que le démarrage du système est terminé. Collegare l'alimentatore al router e attendere 1 minuto fino a quando il LED di sistema passa da lampeggiante a acceso fisso (rosso o blu), il che significa che l'avvio del sistema è completato. Schließen Sie das Netzteil an den Router an und warten Sie 1 Minute, bis die System-LED von blinkend auf dauerhaft leuchtet (rot oder blau). Dies bedeutet, dass der Systemstart abgeschlossen ist. 4 Q3: How to Reset to defaults? A: While the power is still on, keep pressing the reset button for 6 seconds, and wait for 1-2 minutes and it will restore to factory settings. Q4: Why can't my mobile phone enter the Setting Page of Router? A: Please make sure your mobile phone is connected to the Cudy Router Wi-Fi(default name is printed on the buttom of router), and make sure you enter the right site in the browser. (Please follow instructions FAQ -> Q1) Q5: Why can't I enter the setting page after restarting the Router? A: After restarting the Router, maybe your phone or computer connect automatically to other Wi-Fi, please make sure your phone or computer is connected to Cudy Router Wi-Fi. (default name is printed on the bottom of router) Q2: What should I do if i can not find Wi-Fi signal? A: Please make sure the router is connected, power and broad- band interface has no loose. If everything is normal but still no signal, please try to use computer to set, or restore the router to factory settings. If after restoring factory settings but still no signal, you can restart the router, if it still doesn’t work, maybe the router has fault. Q1: What can I do if the login window does not appear? A1: If the computer is set to a static IP address, change its settings to obtain an IP address and DNS server address automatically. A2: Verify that http://cudy.net/ or 192.168.10.1 is correctly entered in the web browser . A3: Use another web browser and try again. A4: Reboot your router and try again. A5: Disable and then enable the network adapter being used. Frequently Asked Questions (FAQ) Modem Quick Installation Guide EspañolItaliano EnglishDeutsch Français ルーターの下部に印刷されているSSID(ネットワーク名)とパスワ ードを使用して、デバイスをルーターのWi-Fiに接します。 コンピューターをルーターに接します(有線または無線) コンピューターのWLANをオフにし、イーサネットケーブルを使 用してルーターのLANポートに接します。 5 5 English Wired Wireless Connect your device to the router’s Wi-Fi using the SSID (network name) and Password printed on the bottom of the router. Connect your computer to the router (Wired or Wireless) Turn off the Wi-Fi on your computer and connect it to router’s LAN port via an ethernet cable. 6 Launch a web browser, and enter http://cudy.net/ or http://192.168.10.1/ in the address bar. Use admin for password to log in. Note: If the login window does not appear, please refer to FAQ > Q1. 6 Webブラウザーを起動し、アドレスバーにhttp://cudy.net/また はhttp://192.168.10.1/を入力します。 ログインするには、パ スワードにadminを使用します。 FAQ> Q1 Log In http://cudy.net/ English admin Log In http://cudy.net/ English admin 7 Then below popup will appear, please follow step by step instructions to set up the internet connections. Note: If the pop-up window does not appear, please click Quick Setup on the status page. [] 7 次に、以下のポップアップが表示されます。インターネット 接をセットアップするためのステップバイステップの指示 にってください。 インターネットをおしみください! Enjoy the internet! Quick Setup Mode Timezone WAN Wireless Summary Exit Next Wireless RouterOpertion Mode Access Point 4 5 3 2 1 Quick Setup Mode Timezone WAN Wireless Summary Exit Next Wireless RouterOpertion Mode Access Point 4 5 3 2 1 810600088 Support For technical support,the user guide and more information, please visit: http://www.cudy.com/support [email protected] テクニカルサポート、ユーザーガイド、および詳細については、 以下をごください: http://www.cudy.com/support [email protected] Q2: Wi-Fi信号が見つからない場合はどうすればよいですか? A: ルーターが接されていること、電源とブロードバンドのイン ターフェースが緩んでいないことを確認してください。 すべてが正 常でも信号がない場合は、コンピューターを使用して設定するか、 ルーターを工場出荷時の設定に復元してください。 工場出荷時の設 定を復元しても信号が表示されない場合、ルーターを再起動できま す。それでも動作しない場合は、ルーターに障害がある可能性があ ります。 Q1: A1: コンピューターが静的IPアドレスに設定されている場合、その 設定を更してIPアドレスとDNSサーバーアドレスを自動的に取得 します。 A2: http://cudy .net/または192.168.10.1がWebブラウザーに正し く入力されていることを確認します。 A3: 別のWebブラウザーを使用して再試行してください。 A4: ルーターを再起動して、もう一度試してください。 A5: 使用中のネットワークアダプターを無効にしてから有効にしま す。 FAQ Q3: A: 61 2 Q4: A:携電話が Cudy ルーター Wi-Fi に接されていることを確認 してください(デフォルト名はルーターのボタンに印刷されてい ます)。また…

Text truncated - open the document above for the full version.

Attestation Statements

Shenzhen Cudy Technology Co., Ltd. ADD: Room A606, Gaoxinqi Industrial Park,Liuxianyi Road, Baoan District Shenzhen, 518101 China Email: [email protected] Tel: +86 755 86008993 Attestation Letter 2021-08-20 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir or Madam, The Main chip, model: MT7621AT, installed in our product AX1800 Gigabit Dual B and Wi-Fi 6 Router, model: X6, FCC ID: 2APRGRT01, this chip supports 5G WIFI bands1/2/3/4, 2.4G WIFI, But for marketing purpose, this chip in this product only su pports 2.4G WIFI & 5G Wi-Fi (5150-5250 MHz, 5725-5850 MHz) band. The other 5G Wi-Fi bands was disabled to use by manufacture in the software, the end user has no capability to activate it. Another the 802.11n for this product do not support the MIMO mode. Sincerely, Signature: Attention: Qiaoyun Sun T itle: Director

External Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ4210425-13605E-RF Page 1 of 5 EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ4210425-13605E-RF Page 2 of 5 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ4210425-13605E-RF Page 3 of 5 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ4210425-13605E-RF Page 4 of 5 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ4210425-13605E-RF Page 5 of 5

ID Label/Location Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ4210425-13605E-RF EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)

Internal Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ4210425-13605E-RF Page 1 of 5 EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ4210425-13605E-RF Page 2 of 5 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ4210425-13605E-RF Page 3 of 5 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ4210425-13605E-RF Page 4 of 5 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ4210425-13605E-RF Page 5 of 5 ANT Chip

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 13 of 167 FCC §15.247 (i) & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) Applicable Standard According to subpart 15.247 (i) and subpart 2.1091 systems operating under the provisions of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in excess of the communication guidelines. Limits for General Population/Uncontrolled Exposure Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (Minutes) 0.3-1.34 614 1.63 *(100) 30 1.34-30 824/f 2.19/f *(180/f 2 ) 30 30-300 27.5 0.073 0.2 30 300-1500 / / f/1500 30 1500-100,000 / / 1.0 30 f = frequency in MHz * = Plane-wave equivalent power density Result Calculated Formulary: Predication of MPE limit at a given distance S = 2 4R PG π S = power density (in appropriate units, e.g. mW/cm2) P = power input to the antenna (in appropriate units, e.g., mW). G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain. R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 14 of 167 Mode Frequency (MHz) Antenna Gain Tune up conducted power Evaluation Distance (cm) Power Density (mW/cm 2 ) MPE Limit (mW/cm 2 ) (dBi) (numeric) (dBm) (mW) 2.4G Wi-Fi 2412-2472 3.0 2.00 28.0 630.96 20 0.25 1 5G Wi-Fi 5150-5250 6.0 3.98 24.0 251.19 20 0.20 1 5725-5850 6.0 3.98 27.0 501.19 20 0.40 1 Note: 1. the tune up conducted power was declared by the applicant 2. the 2.4G Wi-Fi can transmit at the same time with the 5G Wi-Fi. 3. for 5G Wi-Fi, 802.11 ac20/ac40/ac80/ax20/ax40/ax80 mode support Beamforming Directional Gain=G ANT +10log(N ANT /N SS ), For the worst case, N SS =1, so: Directional Gain=3dBi+10log(2/1) dB=6dBi Simultaneous transmitting consideration: The ratio=MPE 2.4G /limit + MPE 5G /limit=0.25/1+0.40/1=0.65<1.0 So simultaneous exposure comply with the limit. To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm from nearby persons. Result: Compliance

Test Report

Note: This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”. BACL is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 15.247 TEST REPORT For Shenzhen Cudy Technology Co., Ltd. Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan 67 District, Shenzhen, China, 518101 FCC ID: 2APRGRT01 Report Type: Original Report Product Type: AX1800 Gigabit Dual Band Wi- Fi 6 Router Re port Number: SZ4210425-13605E-00A Re port Date: 2021-08-10 Reviewed B y: Jacob Kong RF En gineer Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 2 of 167 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 TEST METHODOLOGY .................................................................................................................................................. 4 MEASUREMENT UNCERTAINTY .................................................................................................................................... 5 SYSTEM TEST CONFIGURATION .......................................................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 6 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 6 EUT EXERCISE SOFTWARE .......................................................................................................................................... 7 DUTY CYCLE ................................................................................................................................................................ 8 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 8 EXTERNAL I/O CABLE .................................................................................................................................................. 8 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 9 SUMMARY OF TEST RESULTS ............................................................................................................................. 10 TEST EQUIPMENT LIST ......................................................................................................................................... 11 FCC §15.247 (i) & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) ........................................................ 13 APPLICABLE STANDARD ............................................................................................................................................ 13 RESULT ...................................................................................................................................................................... 13 FCC §15.203 - ANTENNA REQUIREMENT ........................................................................................................... 15 APPLICABLE STANDARD ............................................................................................................................................ 15 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 15 FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS ..................................................................................... 16 APPLICABLE STANDARD ............................................................................................................................................ 16 EUT SETUP ................................................................................................................................................................ 16 EMI TEST RECEIVER SETUP ....................................................................................................................................... 16 TEST PROCEDURE ...................................................................................................................................................... 16 CORRECTED FACTOR & MARGIN CALCULATION ....................................................................................................... 17 TEST DATA ................................................................................................................................................................ 17 FCC §15.209, §15.205 & §15.247(d) - SPURIOUS EMISSIONS ...................................…

Text truncated - open the document above for the full version.

Test Report

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 57 of 167 11N40SISO_Ant1_2442 11N40SISO_Ant2_2442 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 58 of 167 11N40SISO_Ant1_2452 11N40SISO_Ant2_2452 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 59 of 167 11N40SISO_Ant1_2457 11N40SISO_Ant2_2457 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 60 of 167 11N40SISO_Ant1_2462 11N40SISO_Ant2_2462 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 61 of 167 11AX20MIMO_Ant1_2412 11AX20MIMO_Ant1_2417 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 62 of 167 11AX20MIMO_Ant1_2422 11AX20MIMO_Ant1_2442 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 63 of 167 11AX20MIMO_Ant1_2457 11AX20MIMO_Ant1_2462 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 64 of 167 11AX20MIMO_Ant1_2467 11AX20MIMO_Ant1_2472 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 65 of 167 11AX40MIMO_Ant1_2422 11AX40MIMO_Ant1_2427 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 66 of 167 11AX40MIMO_Ant1_2432 11AX40MIMO_Ant1_2442 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 67 of 167 11AX40MIMO_Ant1_2452 11AX40MIMO_Ant1_2457 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 68 of 167 11AX40MIMO_Ant1_2462 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 69 of 167 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Channel OCB [MHz] Limit[MHz] Verdict 11B Ant1 241212.627--- PASS Ant2 241212.468--- PASS Ant1 244212.667--- PASS Ant2 244212.507--- PASS Ant1 246212.627--- PASS Ant2 246212.507--- PASS Ant1 246712.827--- PASS Ant2 246712.787--- PASS Ant1 247212.787--- PASS Ant2 247212.787--- PASS 11G Ant1 241217.223--- PASS Ant2 241217.183--- PASS Ant1 244217.423--- PASS Ant2 244217.463--- PASS Ant1 246217.223--- PASS Ant2 246217.183--- PASS Ant1 246717.263--- PASS Ant2 246717.143--- PASS Ant1 247217.223--- PASS Ant2 247217.183--- PASS 11N20SISO Ant1 241218.062--- PASS Ant2 241218.102--- PASS Ant1 241718.102--- PASS Ant2 241718.102--- PASS Ant1 244218.262--- PASS Ant2 244218.302--- PASS Ant1 246218.022--- PASS Ant2 246218.062--- PASS Ant1 246718.062--- PASS Ant2 246718.102--- PASS Ant1 247218.102--- PASS Ant2 247218.102--- PASS 11N40SISO Ant1 242236.603--- PASS Ant2 242236.523--- PASS Ant1 244236.843--- PASS Ant2 244236.923--- PASS Ant1 245236.444--- PASS Ant2 245236.364--- PASS Ant1 245736.603--- PASS Ant2 245736.523--- PASS Ant1 246236.444--- PASS Ant2 246236.364--- PASS 11AX20MIMO Ant1 241218.821--- PASS 241718.861--- PASS 242219.500--- PASS 244219.421--- PASS 245719.500--- PASS 246219.540--- PASS 246718.861--- PASS 247218.861--- PASS 11AX40MIMO Ant1 242237.722--- PASS 242737.722--- PASS 243237.802--- PASS 244237.802--- PASS 245237.882--- PASS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 70 of 167 TestMode Antenna Channel OCB [MHz] Limit[MHz] Verdict 245737.722--- PASS 246237.802--- PASS Note: for AX20/AX40 mode, the worst case ANT 1 was test. Test Graphs 11B_Ant1_2412 11B_Ant2_2412 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 71 of 167 11B_Ant1_2442 11B_Ant2_2442 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 72 of 167 11B_Ant1_2462 11B_Ant2_2462 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 73 of 167 11B_Ant1_2467 11B_Ant2_2467 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 74 of 167 11B_Ant1_2472 11B_Ant2_2472 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 75 of 167 11G_Ant1_2412 11G_Ant2_2412 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 76 of 167 11G_Ant1_2442 11G_Ant2_2442 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 77 of 167 11G_Ant1_2462 11G_Ant2_2462 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 78 of 167 11G_Ant1_2467 11G_Ant2_2467 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 79 of 167 11G_Ant1_2472 11G_Ant2_2472 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 80 of 167 11N20SISO_Ant1_2412 11N20SISO_Ant2_2412 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 81 of 167 11N20SISO_Ant1_2417 11N20SISO_Ant2_2417 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 82 of 167 11N20SISO_Ant1_2442 11N20SISO_Ant2_2442 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 83 of 167 11N20SISO_Ant1_2462 11N20SISO_Ant2_2462 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 84 of 167 11N20SISO_Ant1_2467 11N20SISO_Ant2_2467

Test Report

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 85 of 167 11N20SISO_Ant1_2472 11N20SISO_Ant2_2472 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 86 of 167 11N40SISO_Ant1_2422 11N40SISO_Ant2_2422 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 87 of 167 11N40SISO_Ant1_2442 11N40SISO_Ant2_2442 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 88 of 167 11N40SISO_Ant1_2452 11N40SISO_Ant2_2452 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 89 of 167 11N40SISO_Ant1_2457 11N40SISO_Ant2_2457 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 90 of 167 11N40SISO_Ant1_2462 11N40SISO_Ant2_2462 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 91 of 167 11AX20MIMO_Ant1_2412 11AX20MIMO_Ant1_2417 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 92 of 167 11AX20MIMO_Ant1_2422 11AX20MIMO_Ant1_2442 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 93 of 167 11AX20MIMO_Ant1_2457 11AX20MIMO_Ant1_2462 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 94 of 167 11AX20MIMO_Ant1_2467 11AX20MIMO_Ant1_2472 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 95 of 167 11AX40MIMO_Ant1_2422 11AX40MIMO_Ant1_2427 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 96 of 167 11AX40MIMO_Ant1_2432 11AX40MIMO_Ant1_2442 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 97 of 167 11AX40MIMO_Ant1_2452 11AX40MIMO_Ant1_2457 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 98 of 167 11AX40MIMO_Ant1_2462 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 99 of 167 Appendix C: Maximum conducted Peak output power Test Result TestMode Antenna Channel Result[dBm] Limit[dBm] Verdict 11B Ant1 241222.09≤30 PASS Ant2 241222.39≤30 PASS Ant1 244221.83≤30 PASS Ant2 244222.33≤30 PASS Ant1 246221.64≤30 PASS Ant2 246222.15≤30 PASS Ant1 246717.68≤30 PASS Ant2 246718.27≤30 PASS Ant1 247213.52≤30 PASS Ant2 247213.98≤30 PASS 11G Ant1 241222.06≤30 PASS Ant2 241222.23≤30 PASS Ant1 244224.46≤30 PASS Ant2 244224.79≤30 PASS Ant1 246221.89≤30 PASS Ant2 246221.90≤30 PASS Ant1 246719.40≤30 PASS Ant2 246719.52≤30 PASS Ant1 247217.16≤30 PASS Ant2 247217.26≤30 PASS 11N20SISO Ant1 241220.91≤30 PASS Ant2 241221.20≤30 PASS Ant1 241721.74≤30 PASS Ant2 241722.19≤30 PASS Ant1 244224.31≤30 PASS Ant2 244224.41≤30 PASS Ant1 246222.35≤30 PASS Ant2 246221.91≤30 PASS Ant1 246720.69≤30 PASS Ant2 246721.69≤30 PASS Ant1 247216.68≤30 PASS Ant2 247216.65≤30 PASS 11N40SISO Ant1 242221.30≤30 PASS Ant2 242221.69≤30 PASS Ant1 244223.23≤30 PASS Ant2 244223.56≤30 PASS Ant1 245220.89≤30 PASS Ant2 245220.98≤30 PASS Ant1 245718.41≤30 PASS Ant2 245718.41≤30 PASS Ant1 246213.75≤30 PASS Ant2 246214.16≤30 PASS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 100 of 167 TestMode Antenna Channel Result[dBm] Limit[dBm] Verdict 11AX20MIMO Ant1 241220.46≤30 PASS Ant2 241220.90≤30 PASS total 241223.7≤30 PASS Ant1 241722.97≤30 PASS Ant2 241722.10≤30 PASS total 241725.6≤30 PASS Ant1 242222.20≤30 PASS Ant2 242222.26≤30 PASS total 242225.2≤30 PASS Ant1 244224.20≤30 PASS Ant2 244224.21≤30 PASS total 244227.2≤30 PASS Ant1 245721.54≤30 PASS Ant2 245722.20≤30 PASS total 245724.9≤30 PASS Ant1 246220.53≤30 PASS Ant2 246219.76≤30 PASS total 246223.2≤30 PASS Ant1 246717.24≤30 PASS Ant2 246717.79≤30 PASS total 246720.5≤30 PASS Ant1 247215.33≤30 PASS Ant2 247215.51≤30 PASS total 247218.4≤30 PASS 11AX40MIMO Ant1 242218.72≤30 PASS Ant2 242219.10≤30 PASS total 242221.9≤30 PASS Ant1 242720.25≤30 PASS Ant2 242720.37≤30 PASS total 242723.3≤30 PASS Ant1 243220.41≤30 PASS Ant2 243220.04≤30 PASS total 243223.2≤30 PASS Ant1 244222.63≤30 PASS Ant2 244223.60≤30 PASS total 244226.2≤30 PASS Ant1 245220.43≤30 PASS Ant2 245221.19≤30 PASS total 245223.8≤30 PASS Ant1 245718.43≤30 PASS Ant2 245719.10≤30 PASS total 245721.8≤30 PASS Ant1 246213.93≤30 PASS Ant2 246214.66≤30 PASS total 246217.3≤30 PASS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 101 of 167 Appendix D: Maximum power spectral density Test Result TestMode Antenna Channel Result[dBm/3kHz] Limit[dBm/3kHz] Verdict 11B Ant12412-1.84≤8 PASS Ant22412-2.75≤8 PASS Ant12442-2.62≤8 PASS Ant22442-3.16≤8 PASS Ant12462-1.74≤8 PASS Ant22462-1.86≤8 PASS Ant12467-6.48≤8 PASS Ant22467-5.97≤8 PASS Ant12472-11.15≤8 PASS Ant22472-10.51≤8 PASS 11G Ant12412-6.57≤8 PASS Ant22412-7.59≤8 PASS Ant12442-3.34≤8 PASS Ant22442-4.80≤8 PASS Ant12462-7.40≤8 PASS Ant22462-8.19≤8 PASS Ant12467-9.97≤8 PASS Ant22467-9.41≤8 PASS Ant12472-13.13≤8 PASS Ant22472-13.48≤8 PASS 11N20SISO Ant12412-7.49≤8 PASS Ant22412-8.13≤8 PASS Ant12417-7.66≤8 PASS Ant22417-7.81≤8 PASS Ant12442-5.20≤8 PASS Ant22442-3.82≤8 PASS Ant12462-7.73≤8 PASS Ant22462-8.24≤8 PASS Ant12467-9.25≤8 PASS Ant22467-9.32≤8 PASS Ant12472-12.38≤8 PASS Ant22472-13.85≤8 PASS 11N40SISO Ant12422-11.21≤8 PASS Ant22422-10.86≤8 PASS Ant12442-7.69≤8 PASS Ant22442-6.59≤8 PASS Ant12452-11.72≤8 PASS Ant22452-10.75≤8 PASS Ant12457-13.20≤8 PASS Ant22457-12.43≤8 PASS Ant12462-17.57≤8 PASS Ant22462-16.71≤8 PASS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 102 of 167 TestMode Antenna Channel Result[dBm/3kHz] Limit[dBm/3kHz] Verdict 11AX20MIMO Ant1 2412-9.52 ≤8 PASS Ant2 2412-9.78 ≤8 PASS…

Text truncated - open the document above for the full version.

Test Report

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 113 of 167 11N20SISO_Ant1_2412 11N20SISO_Ant2_2412 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 114 of 167 11N20SISO_Ant1_2417 11N20SISO_Ant2_2417 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 115 of 167 11N20SISO_Ant1_2442 11N20SISO_Ant2_2442 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 116 of 167 11N20SISO_Ant1_2462 11N20SISO_Ant2_2462 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 117 of 167 11N20SISO_Ant1_2467 11N20SISO_Ant2_2467 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 118 of 167 11N20SISO_Ant1_2472 11N20SISO_Ant2_2472 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 119 of 167 11N40SISO_Ant1_2422 11N40SISO_Ant2_2422 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 120 of 167 11N40SISO_Ant1_2442 11N40SISO_Ant2_2442 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 121 of 167 11N40SISO_Ant1_2452 11N40SISO_Ant2_2452 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 122 of 167 11N40SISO_Ant1_2457 11N40SISO_Ant2_2457 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ4210425-13605E-00A FCC Part 15.247 Page 123 of …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Zhihong Chen(Director)
[email protected]+8613168072961Fax: +8675586008993

Test Firm

Bay Area Compliance Laboratories Corp. (Shenzhen)Well Wang
[email protected]+86 (0) 755 33320018

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.47 GHz525.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes.

Other Applications from Shenzhen Cudy Technology Co., Ltd.

2APRGMS30

AX3000 Whole-Home Wi-Fi 6 Mesh System with 2.5G Port

Jun 30, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX