Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
which support Bluetooth BDR(GFSK) , EDR(π/4‐DQPSK), EDR(8DPSK), BLE, 802.11b, 802.11g, 802.11n20, GSM, WCDMA, HSPA, HSPA+, GPRS, EDGE. For use in the US marketing this chip will not support/enable the BDR, EDR, BLE, GSM, WCDMA, HSPA, HSPA+, GPRS, EDGE. BDR, EDR, BLE, GSM, WCDMA, HSPA, HSPA+, GPRS, EDGE function has been shielded by the manufacturer by using the software. Sincerely, Signature Zhibao Deng Title: Product Director Shenzhen VanTop Technology & Innovation Co., Ltd. 502, 5th Flr. BLDG 4, MinQi Technology Park, No. 65 Lishan Road, Taoyuan Street, Nanshan District, Shenzhen, China Tel: +86-755-84652162 E-mail: [email protected] Attestation Letter Date: 2019/12/17 Dear Sir or Madam: We, Shenzhen VanTop Technology & Innovation Co., Ltd., hereby declare that The Main chip, FCC ID: 2AQ3A-S7, SC7731 , installed in our product named as Tablet, Model No: S7, model:
Shenzhen VanTop Technology & Innovation Co., Ltd. 502, 5th Flr. BLDG 4, MinQi Technology Park, No. 65 Lishan Road, Taoyuan Street, Nanshan District, Shenzhen, China Tel: +86-755-84652162 E-mail: [email protected] Date: 2019-12-17 Tablet Similarity Declaration Dear Sir or Madam, We, Shenzhen VanTop Technology & Innovation Co., Ltd. hereby declare that we have a product named as Tablet (Model number: S7, FCC ID: 2AQ3A-S7) was tested by BACL. Meanwhile, for our marketing purpose, we would like to list a series models (S8/ S8 Pro/ S10/ S20/ S21/ S30/ P31/ E7/ E8/ E10/ E11/ Z1/ Z4/ Z4 Pro/ Z10/ S7 Kids/ S8 Kids/ Z1 Kids/ SZ1 Kids/ SS7 Kids/ SS8 Kids) on reports and certificate. those models listed in below items: 1. The screen of S7/ S8 Pro/ S10/ S20/ S21/ S30/ P31/ E7/ E8/ E10/ E11/ Z1/ Z4/ Z4 Pro/ Z10/ S7 Kids/ S8 Kids/ Z1 Kids/ SZ1 Kids/ SS7 Kids/ SS8 Kids are identical, but S8 is different from them. 2. The difference of the battery in S7/ S8 Pro/ S10/ S20/ S21/ S30/ P31/ E7/ E8/ E10/ E11/ Z1/ Z4/ Z4 Pro/ Z10/ S7 Kids/ S8 Kids/ Z1 Kids/ SZ1 Kids/ SS7 Kids/ SS8 Kids (Model: M713E, Capacity: 2900mAh) and the battery in S8 (Model: M813E, Capacity: 4000mAh) are only the model name and the capacity. 3. The board below is use to drive the screen. The board is on the S8, but the S7/ S8 Pro/ S10/ S20/ S21/ S30/ P31/ E7/ E8/ E10/ E11/ Z1/ Z4/ Z4 Pro/ Z10/ S7 Kids/ S8 Kids/ Z1 Kids/ SZ1 Kids/ SS7 Kids/ SS8 Kids don’t have it. The difference among 4. The main board below on the left is on the S7/ S8 Pro/ S10/ S20/ S21/ S30/ P31/ E7/ E8/ E10/ E11/ Z1/ Z4/ Z4 Pro/ Z10/ S7 Kids/ S8 Kids/ Z1 Kids/ SZ1 Kids/ SS7 Kids/ SS8 Kids, and the main board on the right is on the S8. The difference between these two boards will just use to adjust the matching parameter for different screens. We confirm that all information above is true, and we’ll be responsible for all the consequences. Please contact me if you have any question. Signature: Printed Name: Zhibao Deng Title: Product Director
EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS Model S7: Model S8:
EXHIBIT A - FCC ID LABEL AND LOCATION Model S7: FCC ID Label (Label 1) (Label 2) FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925) Label 1 here Label 2 here Model S8: FCC ID Label (Label 1) (Label 2) FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925) Label 2 here Label 1 here
EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Model S7: Wi-Fi Antenna Model S8: Wi-Fi Antenna
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”. SAR EVALUATION REPORT For Shenzhen VanTop Technology & Innovation Co., Ltd. 502, 5th Flr. BLDG 4, MinQi Technology Park, No. 65 Lishan Road, Taoyuan Street, Nanshan District, Shenzhen, China FCC ID: 2AQ3A-S7 Report Type: Original Report Product Type: Tablet Report Number: RSZ191125811-20A Report Date: 2019-12-03 Reviewed By: Rocky Xiao RF Engineer Prepared By: Bay Area Compliance Laboratories Corp. (Dongguan) No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RSZ191125811-20A SAR Evaluation Report 2 of 36 Attestation of Test Results EUT Information EUT Description Tablet Tested Model S7 Multiple Models S8, S8 Pro, S10, S20, S21, S30, P31, E7, E8, E10, E11, Z1, Z4, Z4 Pro, Z10, S7 Kids, S8 Kids, Z1 Kids, SZ1 Kids, SS7 Kids, SS8 Kids FCC ID 2AQ3A-S7 Serial Number RSZ191125811-SA-S1 Test Date 2019-11-26 MODE Max. SAR Level(s) Reported(W/kg) Limit (W/kg) Body Mode WLAN 2.4G 1g Body SAR 0.99 1.6 Applicable Standards FCC 47 CFR part 2.1093 Radiofrequency radiation exposure evaluation: portable devices IEEE1528:2013 IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques IEC 62209-2:2010 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices-Human models, instrumentation, and procedures-Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximit y to the human body (frequencyrange of 30 MHz to 6 GHz) KDB procedures KDB 447498 D01 General RF Exposure Guidance v06 KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz v01r04 KDB 865664 D02 RF Exposure Reporting v01r02 KDB 616217 D04 SAR for laptop and tablets v01r02 KDB 248227 D01 802 11 Wi-Fi SAR v02r02 Note: This wireless device has been shown to be capable of compliance for localized specific absorption rate (SAR) for General Population/Uncontrolled Exposure limits specified in FCC 47 CFR part 2.1093 and has been tested in accordance with the measurement procedures specified in IEEE 1528-2013 and RF exposure KDB procedures. The results and statements contained in this report pertain only to the device(s) evaluated. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RSZ191125811-20A SAR Evaluation Report 3 of 36 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 4 EUT DESCRIPTION .................................................................................................................................................... 5 TECHNICAL SPECIFICATION ......................................................................................................................................... 5 REFERENCE, STANDARDS, AND GUIDELINES .................................................................................................. 6 SAR LIMITS ................................................................................................................................................................. 7 FACILITIES .................................................................................................................................................................. 8 DESCRIPTION OF TEST SYSTEM .......................................................................................................................... 9 EQUIPMENT LIST AND CALIBRATION ............................................................................................................. 14 EQUIPMENTS LIST & CALIBRATION INFORMATION .................................................................................................... 14 SAR MEASUREMENT SYSTEM VERIFICATION .............................................................................................. 15 LIQUID VERIFICATION ............................................................................................................................................... 15 SYSTEM ACCURACY VERIFICATION ........................................................................................................................... 16 SAR SYSTEM VALIDATION DATA ..................................................................................................................... 17 EUT TEST STRATEGY AND METHODOLOGY ................................................................................................. 18 TEST POSITIONS FOR DEVICE OPERATING NEXT TO A PERSON’S EAR........................................................................ 18 CHEEK/TOUCH POSITION ........................................................................................................................................... 19 EAR/TILT POSITION ................................................................................................................................................... 19 TEST POSITIONS FOR BODY-WORN AND OTHER CONFIGURATIONS .............................................................................. 20 TEST DISTANCE FOR SAR EVALUATION .................................................................................................................... 20 SAR EVALUATION PROCEDURE .........................................................................…
Text truncated - open the document above for the full version.
APPENDIX C PROBE CALIBRATION CERTIFICATES DIPOLE CALIBRATION CERTIFICATES
Report No.: RSZ191125811-20A SAR Plots Plot 1# Test Plot 1#: WLAN 2.4G Mode B_Body Back_Low DUT: Tablet; Type: S7; Serial: RSZ191125811-SA-S1 Communication System: IEEE 802.11b WiFi 2.4 GHz; Frequency: 2412 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2412 MHz; σ = 1.774 S/m; ε r = 40.472; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN7329; ConvF(7.6, 7.6, 7.6) @ 2412 MHz; Calibrated: 2019/10/22 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn772; Calibrated: 2019/10/6 Phantom: Twin SAM; Type: Twin SAM V5.0; Serial: TP:1412 Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (91x91x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 0.566 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 0.7600 V/m; Power Drift = 0.12 dB Peak SAR (extrapolated) = 0.787 W/kg SAR(1 g) = 0.303 W/kg; SAR(10 g) = 0.122 W/kg Maximum value of SAR (measured) = 0.586 W/kg 0 dB = 0.586 W/kg = -2.32 dBW/kg Report No.: RSZ191125811-20A SAR Plots Plot 2# Test Plot 2#: WLAN 2.4G Mode B_Body Back_Mid DUT: Tablet; Type: S7; Serial: RSZ191125811-SA-S1 Communication System: IEEE 802.11b WiFi 2.4 GHz; Frequency: 2442 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2442 MHz; σ = 1.789 S/m; ε r = 40.362; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN7329; ConvF(7.6, 7.6, 7.6) @ 2442 MHz; Calibrated: 2019/10/22 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn772; Calibrated: 2019/10/6 Phantom: Twin SAM; Type: Twin SAM V5.0; Serial: TP:1412 Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (91x111x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 0.468 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 0.6560 V/m; Power Drift = 0.14 dB Peak SAR (extrapolated) = 0.759 W/kg SAR(1 g) = 0.298 W/kg; SAR(10 g) = 0.120 W/kg Maximum value of SAR (measured) = 0.570 W/kg 0 dB = 0.570 W/kg = -2.44 dBW/kg Report No.: RSZ191125811-20A SAR Plots Plot 3# Test Plot 3#: WLAN 2.4G Mode B_Body Back_High DUT: Tablet; Type: S7; Serial: RSZ191125811-SA-S1 Communication System: IEEE 802.11b WiFi 2.4 GHz; Frequency: 2472 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2472 MHz; σ = 1.87 S/m; ε r = 38.633; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN7329; ConvF(7.6, 7.6, 7.6) @ 2472 MHz; Calibrated: 2019/10/22 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn772; Calibrated: 2019/10/6 Phantom: Twin SAM; Type: Twin SAM V5.0; Serial: TP:1412 Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (91x101x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 0.431 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 0.9980 V/m; Power Drift = -0.15 dB Peak SAR (extrapolated) = 0.663 W/kg SAR(1 g) = 0.257 W/kg; SAR(10 g) = 0.104 W/kg Maximum value of SAR (measured) = 0.490 W/kg 0 dB = 0.490 W/kg = -3.10 dBW/kg Report No.: RSZ191125811-20A SAR Plots Plot 4# Test Plot 4#: WLAN 2.4G Mode B_Body Bottom_Mid DUT: Tablet; Type: S7; Serial: RSZ191125811-SA-S1 Communication System: IEEE 802.11b WiFi 2.4 GHz; Frequency: 2442 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2442 MHz; σ = 1.789 S/m; ε r = 40.362; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN7329; ConvF(7.6, 7.6, 7.6) @ 2442 MHz; Calibrated: 2019/10/22 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn772; Calibrated: 2019/10/6 Phantom: Twin SAM; Type: Twin SAM V5.0; Serial: TP:1412 Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (51x111x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 0.479 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 12.74 V/m; Power Drift = -0.10 dB Peak SAR (extrapolated) = 0.729 W/kg SAR(1 g) = 0.242 W/kg; SAR(10 g) = 0.085 W/kg Maximum value of SAR (measured) = 0.501 W/kg 0 dB = 0.501 W/kg = -3.00 dBW/kg Report No.: RSZ191125811-20A SAR Plots Plot 5# Test Plot 5#: WLAN 2.4G Mode G_Body Back_Low DUT: Tablet; Type: S7; Serial: RSZ191125811-SA-S1 Communication System: IEEE 802.11g WiFi 2.4 GHz; Frequency: 2412 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2412 MHz; σ = 1.774 S/m; ε r = 40.472; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN7329; ConvF(7.6, 7.6, 7.6) @ 2412 MHz; Calibrated: 2019/10/22 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn772; Calibrated: 2019/10/6 Phantom: Twin SAM; Type: Twin SAM V5.0; Serial: TP:1412 Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (91x101x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 1.48 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 0.7380 V/m; Power Drift = -0.10 dB Peak SAR (extrapolated) = 2.48 W/kg SAR(1 g) = 0.896 W/kg; SAR(10 g) = 0.345 W/kg Maximum value of SAR (measured) = 1.86 W/kg 0 dB = 1.86 W/kg = 2.70 dBW/kg Report No.: RSZ191125811-20A SAR Plots Plot 6# Test Plot 6#: WLAN 2.4G Mode G_Body Back_Mid DUT: Tablet; Type: S7; Serial: RSZ191125811-SA-S1 Communication System: IEEE 802.11g WiFi 2.4 GHz; Frequency: 2442 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2442 MHz; σ = 1.789 S/m; ε r = 40.362; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN7329; ConvF(7.6, 7.6, 7.6) @ 2442 MHz; Calibrated: 2019/10/22 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn772; Calibrated: 2019/10/6 Phantom: Twin SAM; Type: Twin SAM V5.0; Serial: TP:1412 Measuremen…
Text truncated - open the document above for the full version.
Report No.: RSZ191125811-20A Page 1 of 2 APPENDIX B EUT TEST POSITION PHOTOS Liquid depth ≥ 15cm Phantom Type: Twin SAM; Model: Twin SAM V5.0; S/N: 1412 Report No.: RSZ191125811-20A Page 2 of 2 Body Back Setup Photo (0mm) Body Bottom Setup Photo (0mm)
Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government. This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”. BACL is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 15.247 TEST REPORT For Shenzhen VanTop Technology & Innovation Co., Ltd. 502, 5th Flr. BLDG 4, MinQi Technology Park, No. 65 Lishan Road, Taoyuan Street, Nanshan District, Shenzhen, China FCC ID: 2AQ3A-S7 Report Type: Original Report Product Type: Tablet Re port Number: RSZ191023810-00 Re port Date: 2019-12-13 Reviewed B y: Nancy Wang RF En gineer Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone, Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 FCC Part 15.247 Page 2 of 33 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 4 TEST METHODOLOGY .................................................................................................................................................. 4 MEASUREMENT UNCERTAINTY .................................................................................................................................... 5 SYSTEM TEST CONFIGURATION .......................................................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 6 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 6 EUT EXERCISE SOFTWARE .......................................................................................................................................... 6 DUTY CYCLE ................................................................................................................................................................ 7 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 7 EXTERNAL I/O CABLE .................................................................................................................................................. 7 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 7 SUMMARY OF TEST RESULTS ............................................................................................................................... 8 TEST EQUIPMENT LIST ........................................................................................................................................... 9 FCC §1.1307(b) & §2.1093 - RF EXPOSURE INFORMATION ............................................................................ 11 APPLICABLE STANDARD ............................................................................................................................................ 11 TEST RESULT ............................................................................................................................................................. 11 FCC §15.203 - ANTENNA REQUIREMENT ........................................................................................................... 12 APPLICABLE STANDARD ............................................................................................................................................ 12 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 12 FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS ..................................................................................... 13 APPLICABLE STANDARD ............................................................................................................................................ 13 EUT SETUP ................................................................................................................................................................ 13 EMI TEST RECEIVER SETUP ....................................................................................................................................... 13 TEST PROCEDURE ...................................................................................................................................................... 13 CORRECTED FACTOR & MARGIN CALCULATION ..............................................................…
Text truncated - open the document above for the full version.
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 Page 1 of 14 Appendix A: DTS Bandwidth Test Result TestMode AntennaChannel DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11B Ant1 2412 9.840 2407.200 2417.0400.5 PASS 2442 9.840 2436.960 2446.8000.5 PASS 2472 9.680 2466.920 2476.6000.5 PASS 11G Ant1 2412 16.440 2403.800 2420.2400.5 PASS 2442 16.440 2433.800 2450.2400.5 PASS 2472 16.400 2463.800 2480.2000.5 PASS 11N20SISO Ant1 2412 17.640 2403.200 2420.8400.5 PASS 2442 17.680 2433.160 2450.8400.5 PASS 2472 17.400 2463.160 2480.5600.5 PASS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 Page 2 of 14 Test Graphs 11B_Ant1_2412 11B_Ant1_2442 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 Page 3 of 14 11B_Ant1_2472 11G_Ant1_2412 11G_Ant1_2442 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 Page 4 of 14 11G_Ant1_2472 11N20SISO_Ant1_2412 11N20SISO_Ant1_2442 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 Page 5 of 14 11N20SISO_Ant1_2472 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 Page 6 of 14 Appendix B: Maximum conducted output power Test Result TestMode Antenna Channel Result[dBm] Limit[dBm] Verdict 11B Ant1 2412 10.97 <=30 PASS 2442 10.12 <=30 PASS 2472 8.51 <=30 PASS 11G Ant1 2412 20.55 <=30 PASS 2442 19.40 <=30 PASS 2472 18.56 <=30 PASS 11N20SISO Ant1 2412 19.23 <=30 PASS 2442 18.26 <=30 PASS 2472 18.78 <=30 PASS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 Page 7 of 14 Appendix C: Maximum power spectral density Test Result TestMode Antenna Channel Result[dBm/3-100kHz] Limit[dBm/3kHz] Verdict 11B Ant1 2412 -3.1 <=8 PASS 2442 -4 <=8 PASS 2472 -5.61 <=8 PASS 11G Ant1 2412 -13.26 <=8 PASS 2442 -14.34 <=8 PASS 2472 -15.14 <=8 PASS 11N20SISO Ant1 2412 -14.36 <=8 PASS 2442 -15.46 <=8 PASS 2472 -15.46 <=8 PASS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 Page 8 of 14 Test Graphs 11B_Ant1_2412 11B_Ant1_2442 11B_Ant1_2472 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 Page 9 of 14 11G_Ant1_2412 11G_Ant1_2442 11G_Ant1_2472 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 Page 10 of 14 11N20SISO_Ant1_2412 11N20SISO_Ant1_2442 11N20SISO_Ant1_2472 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 Page 11 of 14 Appendix D: Band edge measurements Test Graphs 11B_Ant1_Low_2412 11B_Ant1_High_2472 11G_Ant1_Low_2412 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 Page 12 of 14 11G_Ant1_High_2472 11N20SISO_Ant1_Low_2412 11N20SISO_Ant1_High_2472 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 Page 13 of 14 Appendix E: DutyCycle Test Result TestMode AntennaChannel TransmissionDuration [ms] Transmission Period [ms] Duty Cycle [%] 11B Ant1 2442 8.36 8.48 98.58 11G Ant1 2442 1.38 1.42 97.18 11N20SISO Ant1 2442 1.29 1.34 96.27 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ191023810-00 Page 14 of 14 Test Graphs 11B_Ant1_2442 11G_Ant1_2442 11N20SISO_Ant1_2442
EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions - Front View Conducted Emissions - Side View Radiated Emissions View (Below 1 GHz) Radiated Emissions View (Above 1 GHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.47 GHz | 114.00 mW |
Projector
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Projector
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
R/C QUADCOPTER
Equipment Class
DTS - Digital Transmission System
REMOTE
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
R/C QUADCOPTER
Equipment Class
DTS - Digital Transmission System