Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Shenzhen VanTop Technology & Innovation Co., Ltd. 502, 5th Flr. BLDG 4, MinQi Technology Park, No. 65 Lishan Road, Taoyuan Street, Nanshan District, Shenzhen, China Tel: +86-755-84652162 E-mail: [email protected] Date: 2020-11-24 Walkie Talkie Similarity Declaration Dear Sir or Madam, We, Shenzhen VanTop Technology & Innovation Co., Ltd. hereby declare that we have a product named as Walkie Talkie (Model number: VT10 FCC ID: 2AQ3A-VT10) was tested by BACL. Meanwhile, for our marketing purpose, we would like to list a series models (VT20, VT30,VT40,VT50,VT60,VT70,VT80,VT90) on reports and certificate. All of the models are electrically identical, but the difference among them is model name. We confirm that all information above is true, and we’ll be responsible for all the consequences. Please contact me if you have any question. Signature: Printed Name: Zhibao Deng Title: Product Director
Shenzhen VanTop Technology & Innovation Co., Ltd. 502, 5th Flr. BLDG 4, MinQi Technology Park, No. 65 Lishan Road, Taoyuan Street, Nanshan District, Shenzhen, China Tel: 86-0755-84652162 Email: [email protected] QA-FR-170-B 7/29/2014 FCC Authorization Date: 2020-12-01 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Shenzhen VanTop Technology & Innovation Co., Ltd., the undersigned, hereby authorizes Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corporation on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Zhibao Deng Title: Product Director
Shenzhen VanTop Technology & Innovation Co., Ltd. 502, 5th Flr. BLDG 4, MinQi Technology Park, No. 65 Lishan Road, Taoyuan Street, Nanshan District, Shenzhen, China Tel: 86-0755-84652162 Email: [email protected] FCC Confidential Authorization Date: 2020-12-01 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AQ3A-VT10, In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Shenzhen VanTop Technology & Innovation Co., Ltd. hereby requests long-term confidential treatment of information accompanying this application as outlined below: • Block Diagram • Schematics • Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Zhibao Deng Title: Product Director
Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ201013007-RF Page 1 of 4 EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ201013007-RF Page 2 of 4 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ201013007-RF Page 3 of 4 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ201013007-RF Page 4 of 4
Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ201013007-RF EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)
Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ201013007-RF Page 1 of 4 EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ201013007-RF Page 2 of 4 Antenna Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ201013007-RF Page 3 of 4 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ201013007-RF Page 4 of 4
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”. SAR EVALUATION REPORT For Shenzhen VanTop Technology & Innovation Co.,Ltd. 502, 5th Flr. BLDG 4, MinQi Technology Park, No. 65 Lishan Road, Taoyuan Street, Nanshan District, Shenzhen, China FCC ID: 2AQ3A-VT10 Report Type: Original Report Product Type: Walkie Talkie Report Number: RSZ201013007-20A Report Date: 2020-11-20 Reviewed By: Brave Lu SAR Engineer Prepared By: Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RSZ201013007-20A SAR Evaluation Report 2 of 36 Attestation of Test Results EUT Information EUT Description Walkie Talkie Tested Model VT10 Multiple Models VT20, VT30, VT40, VT50, VT60, VT70, VT80,VT90 FCC ID 2AQ3A-VT10 Serial Number RSZ201013007-SA-S1 Test Date 2020-09-22 MODE Max. SAR Level(s) Reported(W/kg) Limit (W/kg) PTT 1g Head SAR (Face Up) 0.36 1.6 1g Body SAR (Body Back) 0.59 Applicable Standards FCC 47 CFR part 2.1093 Radiofrequency radiation exposure evaluation: portable devices RF Exposure Procedures: TCB Workshop April 2019 IEEE1528:2013 IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques IEC 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices – Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz) KDB procedures KDB 447498 D01 General RF Exposure Guidance v06 KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz v01r04 KDB 865664 D02 RF Exposure Reporting v01r02 KDB 643646 D01 SAR Test for PTT Radios v01r03 Note: This wireless device has been shown to be capable of compliance for localized specific absorption rate (SAR) for General Population/Uncontrolled Exposure limits specified in FCC 47 CFR part 2.1093 and has been tested in accordance with the measurement procedures specified in IEEE 1528-2013 and RF exposure KDB procedures. The results and statements contained in this report pertain only to the device(s) evaluated. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RSZ201013007-20A SAR Evaluation Report 3 of 36 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 4 EUT DESCRIPTION .................................................................................................................................................... 5 TECHNICAL SPECIFICATION ......................................................................................................................................... 5 REFERENCE, STANDARDS, AND GUIDELINES .................................................................................................. 6 SAR LIMITS ................................................................................................................................................................. 7 FACILITIES .................................................................................................................................................................. 8 DESCRIPTION OF TEST SYSTEM .......................................................................................................................... 9 EQUIPMENT LIST AND CALIBRATION ............................................................................................................. 14 EQUIPMENTS LIST & CALIBRATION INFORMATION .................................................................................................... 14 SAR MEASUREMENT SYSTEM VERIFICATION .............................................................................................. 15 LIQUID VERIFICATION ............................................................................................................................................... 15 SYSTEM ACCURACY VERIFICATION ........................................................................................................................... 16 SAR SYSTEM VALIDATION DATA ..................................................................................................................... 17 EUT TEST STRATEGY AND METHODOLOGY ................................................................................................. 18 TEST POSITIONS FOR DEVICE OPERATING NEXT TO A PERSON’S EAR........................................................................ 18 CHEEK/TOUCH POSITION ........................................................................................................................................... 19 EAR/TILT POSITION ................................................................................................................................................... 19 TEST POSITIONS FOR BODY-WORN AND OTHER CONFIGURATIONS .............................................................................. 20 TEST DISTANCE FOR SAR EVALUATION .................................................................................................................... 20 SAR EVALUATION PROCEDURE ................................................................................................................................. 21 OUTPUT POWER MEASUREMENT.....................................…
Text truncated - open the document above for the full version.
Report No.: RSZ201013007-20A Page 1 of 2 APPENDIX B EUT TEST POSITION PHOTOS Liquid depth ≥ 15cm Report No.: RSZ201013007-20A Page 2 of 2 Face Up Setup Photo(25mm) Body Back Setup Photo(0mm) 35mm 15mm 25mm
Note: This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”. BACL is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 95 MEASUREMENT AND TEST REPORT For Shenzhen VanTop Technology & Innovation Co., Ltd. 502, 5th Flr. BLDG 4, MinQi Technology Park No. 65 Lishan Road, Taoyuan Street, Nanshan District, Shenzhen, China FCC ID: 2AQ3A-VT10 Report Type: Original Report Product Type: Walkie Talkie Report Number: RSZ201013007-00B Report Date: 2021-01-06 Reviewed By: Jimmy Xiao RF En gineer Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone, Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ201013007-00B FCC Part 95 Page 2 of 25 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .................................................................................... 3 OBJECTIVE ................................................................................................................................................................... 3 TEST METHODOLOGY .................................................................................................................................................. 3 MEASUREMENT UNCERTAINTY .................................................................................................................................... 4 TEST FACILITY ............................................................................................................................................................. 4 SYSTEM TEST CONFIGURATION .......................................................................................................................... 5 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 5 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 5 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 5 EXTERNAL I/O CABLE .................................................................................................................................................. 5 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 6 SUMMARY OF TEST RESULTS ............................................................................................................................... 7 TEST EQUIPMENT LIST ........................................................................................................................................... 8 §2.1093 - RF EXPOSURE INFORMATION .............................................................................................................. 9 APPLICABLE STANDARD .............................................................................................................................................. 9 TEST RESULT ............................................................................................................................................................... 9 FCC §95.587(b)(1)(2)(3) – ANTENNA REQUIREMENT ....................................................................................... 10 APPLICABLE STANDARD ............................................................................................................................................ 10 ANTENNA DESCRIPTION ............................................................................................................................................. 10 FCC §2.1046 & §95.567 - RF OUTPUT POWER ..................................................................................................... 11 APPLICABLE STANDARD ............................................................................................................................................ 11 TEST PROCEDURE ...................................................................................................................................................... 11 TEST DATA ................................................................................................................................................................ 11 FCC §2.1047 & §95.575 - MODULATION CHARACTERISTIC .......................................................................... 12 APPLICABLE STANDARD ............................................................................................................................................ 12 TEST PROCEDURE ...................................................................................................................................................... 12 TEST DATA ................................................................................................................................................................ 12 FCC §2.1049 & §95.573 & §95.579 - AUTHOURIZED BANDWID…
Text truncated - open the document above for the full version.
Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ201013007-RF Page 1 of 1 EXHIBIT D - TEST SETUP PHOTOGRAPHS Radiated Emissions View (Below 1 GHz) Radiated Emissions View (Above 1 GHz)
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 95B | 467.5625 MHz - 467.7125 MHz | 143.00 mW | 11K0F3E | 2.5 ppm |
Projector
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Projector
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
R/C QUADCOPTER
Equipment Class
DTS - Digital Transmission System
REMOTE
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
R/C QUADCOPTER
Equipment Class