FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SWORD Health S.A./
  3. 2AQ4A-MB1

2AQ4A-MB1Smart Band

SWORD Health S.A.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 23, 2026
Application Purpose
Original Equipment
Equipment Note
Smart Band
Frequency Range
2402.00000000 - 2480.00000000
Company
SWORD Health S.A.
Country
Portugal

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Attestation Letter December 11, 2025 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID: 2AQ4A-MB1 Sword Health S.A (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Márcio Colunas Chief Scientific Officer +351917931684 [email protected] Sword Health S.A. Avenida Sidónio Pais, 153, Edifício A, Piso 5, 4100-467 Porto, Portugal CFR 47 §2.911(d)(5)(i) Attestation Letter Doc ID: 03e2f3e7a60e08ee41f1c18fe0c2dd205ae9ff68

Attestation Statements

Attestation Letter December 11, 2025 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID: 2AQ4A-MB1 Sword Health S.A (“the applicant”) certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment, the product does not use Kapersky software information Sincerely, Márcio Colunas Chief Scientific Officer +351917931684 [email protected] Sword Health S.A. Avenida Sidónio Pais, 153, Edifício A, Piso 5, 4100-467 Porto, Portugal CFR 47 §2.911 (d)(5)(ii) Attestation Letter Doc ID: 03e2f3e7a60e08ee41f1c18fe0c2dd205ae9ff68

Attestation Statements

CFR 47 §2.911(d)(7) U.S Agent CFR 47 §2.911(d)(7) Agent Designation Attestation December 12, 2025 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2AQ4A-MB1 Sword Health S.A (“the applicant”) as required by section 2.911(d)(7), designates the following agent, located in the United States, for purposes of acting as the applicant’s agent for service of process. The applicant acknowledges the applicant’s acceptance to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- related proceeding involving the equipment. U.S. Agent Information: Corporation Service Company 1090 Vermont Avenue N.W., Washington, DC 20005 Email: [email protected] Sincerely yours, Márcio Colunas CSO +351917931684 [email protected] Sword Health S.A. Avenida Sidonio Pais 153 Edificio A, Piso 5 4100-467 Porto, Portugal Corporation Service Company accepts appointment as U.S. agent to receive service of process for Sword Health S.A. By: _________________________ Authorized Representative Doc ID: 3f3a2b5df8bbc1cc4f1feea60bc44907e9253467

Cover Letter(s)

FCC Authorization December 11, 2025 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We Sword Health S.A, the undersigned, hereby authorizes Bay Area Compliance Laboratories Corp. to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Márcio Colunas Chief Scientific Officer +351917931684 [email protected] Sword Health S.A. Avenida Sidónio Pais, 153, Edifício A, Piso 5, 4100-467 Porto, Portugal QA-FR-170-B 7/29/2014 Doc ID: 03e2f3e7a60e08ee41f1c18fe0c2dd205ae9ff68

Cover Letter(s)

QA-FR-172-A FCC Confidential Authorization December 11, 2025 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AQ4A-MB1 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, SWORD Health S.A, hereby requests long-term confidential treatment of information accompanying this application as outlined below:  Block Diagram  Schematics  Operation Description As well as 180-day short-term confidential treatment of information accompanying this application as outlined below:  Internal Photos  User’s Manual  External Photos  Test Set-up Photos The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Márcio Colunas Chief Scientific Officer +351917931684 [email protected] Sword Health S.A. Avenida Sidónio Pais, 153, Edifício A, Piso 5, 4100-467 Porto, Portugal

Cover Letter(s)

SwordHealthSA AvenidaSidónioPais153 EdifícioA,Piso5 4100-467Porto,Portugal June4,2024 Re:AuthorizationofMárcioColunasasSignatoryforSwordHealthSA ToWhomItMayConcern: IherebyauthorizeMárcioColunasasanauthorizedsignatoryforallreports, applications,andsupportingdocumentationsubmittedonbehalfofSwordHealthSA toBayAreaComplianceLaboratoryandtheFederalCommunicationsCommission (FCC)oftheUnitedStatesofAmerica.Márcioisaco-founderandcorporateofficerof SwordHealth. Sincerely, ElenaCavallini SrDirector,QARA SwordHealthSA 1 DocuSign Envelope ID: B2CF347C-7505-4E93-9CE2-379D2D57FC80

ID Label/Location Info

●M-Band will be sold under two different SKUs, with the only difference being the packaging artwork and an the additional colored strap. ●The SKUs will be MB1-US-A01 for our Move business unit, and MB1-US-B01 for our Mind business unit. ●The label design and following slide on location applies to both SKUs. Label Design Sword Health 2AQ4A-MB1: Label & Label Location Label Location ●Label will be located on the bottom side of the packaging ●Rendering is only for reference; content is to match the previous slide. Bottom box dieline artwork Sword Health 2AQ4A-MB1: Label & Label Location ●“SAMPLE” will be removed from the artwork. Device Marking Top surface of M-Band deviceDevice marking content Sword Health 2AQ4A-MB1: Label & Label Location FCC ID: SN: IP68 2AQ4A-MB1 W2512A1B1 Device Marking Placement ●Information to be laser engraved on the top surface of the device, underneath the fabric strap.

RF Exposure Info

Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 17 of 59 FCC 15.247 Test Report 5 FCC §2.1093, FCC §15.247(i) – RF Exposure 5.1 Applicable Standards According to FCC §15.247(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to FCC KDB 447498 D01 General RF Exposure Guidance v06 Section 4.3.1, Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions. The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc. 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following, and as illustrated in Appendix B: a) [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at 100 MHz to 1500 MHz b) [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6 GHz 3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion, and as illustrated in Appendix C: Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 18 of 59 FCC 15.247 Test Report a) The power threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm b) The power threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test separation distances ≤ 50 mm c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to be acceptable. Test exclusion is applied to the required test channels on a channel by channel basis. When SAR evaluation is required by the hotspot mode or UMPC mini-tablet procedures, that is, where an antenna is ≤ 2.5 cm from a surface or edge, the test separation distance from the phantom to the antenna or device enclosure, as appropriate, should be applied to determine further SAR test exclusion according to the criteria in this document. Do not use the antenna to device surface or edge distance. This is equivalent to the formula written as: [(max. power of channel, including tune-up tolerance, mW)/(60 √ f(GHz) mW)]·[20 mm/(min. test separation distance, mm)] ≤ 1.0 for 1-g SAR; also see Appendix A for approximate exclusion threshold numerical values at selected frequencies and distances. Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 19 of 59 FCC 15.247 Test Report 5.2 MPE Results for FCC Maximum output power at antenna input terminal (dBm): 6.36 Maximum output power including tune-up tolerance (dBm): Maximum output power including tune-up tolerance (mW): 7.36 5.44 Transmit frequency (GHz): 2.480 Minimum test separation distance (mm): 5 Calculated SAR test exclusion threshold: 1.71 SAR test exclusion threshold limit: ≤ 3 The device is compliant with the SAR test exclusion threshold limit. The maximum SAR test exclusion threshold calculated is 1.71. Limit is ≤3.

Test Report

Note: This test report was prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This test report shall not be used by the customer to claim product certification, approval, or endorsement by A2LA or any agency of the United States Government or any foreign government. * This test report may contain data and test methods that are not covered by BACL’s scope of accreditation as of the test report date shown above. These items are marked within the test report text with an asterisk “*” FCC PART 15, SUBPART C TEST REPORT For Sword Health S.A. Av. de Sidónio Pais 153 Edifício A, Piso 5 4100-467 Porto Portugal, VAT #: 510675565 FCC ID: 2AQ4A-MB1 R e p o r t T y p e : O r i g i n a l R e p o r t P r o d u c t T y p e : S m a r t B a n d Prepared By: Rachana Khanduri RF Project Engineer Report Number: R2511194-247 Report Date: 2025-12-29 Reviewed By: Christian McCaig RF Lead Engineer Bay Area Compliance Laboratories Corp. 1274 Anvilwood Avenue, Sunnyvale, CA 94089, USA Tel: (408) 732-9162 Fax: (408) 732-9164 Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 2 of 59 FCC 15.247 Test Report TABLE OF CONTENTS 1 GENERAL DESCRIPTION ...................................................................................................................................... 5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ............................................................................ 5 1.2 MECHANICAL DESCRIPTION OF EUT ................................................................................................................... 5 1.3 OBJECTIVE ........................................................................................................................................................... 5 1.4 RELATED SUBMITTAL(S)/GRANT(S) ..................................................................................................................... 5 1.5 TEST METHODOLOGY .......................................................................................................................................... 6 1.6 MEASUREMENT UNCERTAINTY ............................................................................................................................ 6 1.7 TEST FACILITY REGISTRATIONS ........................................................................................................................... 6 1.8 TEST FACILITY ACCREDITATIONS ........................................................................................................................ 7 2 SYSTEM TEST CONFIGURATION ..................................................................................................................... 11 2.1 JUSTIFICATION ................................................................................................................................................... 11 2.2 EUT EXERCISE SOFTWARE ................................................................................................................................ 11 2.3 DUTY CYCLE CORRECTION FACTOR .................................................................................................................. 12 2.4 LOCAL SUPPORT EQUIPMENT ............................................................................................................................. 14 2.5 REMOTE SUPPORT EQUIPMENT .......................................................................................................................... 14 2.6 POWER SUPPLY AND LINE FILTERS .................................................................................................................... 14 2.7 INTERFACE PORTS AND CABLING ....................................................................................................................... 14 3 SUMMARY OF TEST RESULTS ........................................................................................................................... 15 4 FCC §15.203 – ANTENNA REQUIREMENTS ..................................................................................................... 16 4.1 APPLICABLE STANDARDS .................................................................................................................................. 16 4.2 ANTENNA DESCRIPTION ..................................................................................................................................... 16 5 FCC §2.1093, FCC §15.247(I) – RF EXPOSURE .................................................................................................. 17 5.1 APPLICABLE STANDARDS .................................................................................................................................. 17 5.2 MPE RESULTS FOR FCC .................................................................................................................................... 19 6 FCC §15 207 - AC LINE CONDUCTED EMISSIONS ......................................................................................... 20 6.1 APPLICABLE STANDARDS .................................................................................................................................. 20 6.2 TEST SETUP........................................................................................................................................................ 20 6.3 TEST PROCEDURE .............................................................................................................................................. 20 6.4 CORRECTED AMPLITUDE AND MARGIN CALCULATION ..................................................................................... 21 6.5 TEST SETUP BLOCK DIAGRAM ........................................................................................................................... 22 6.6 TEST EQUIPMENT LIST AND DETAILS ........................................…

Text truncated - open the document above for the full version.

Test Report

Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 1 of 3 FCC 15.247 Test Report ANNEX A - Emission Bandwidth Naming Convention Channel (Low, Mid, High)_Frequency (MHz)_Rate (1MBit, 2MBit)_Measurement (Occupied bandwidth) _Type (99percent, -6dB) Low Ch_2402MHz_1MBit_Occupied Bandwidth_- 6dB Low Ch_2402MHz_1MBit_Occupied Bandwidth_99 percent Mid Ch_2440MHz_1MBit_Occupied Bandwidth_- 6dB Mid Ch_2440MHz_1MBit_Occupied Bandwidth_99 percent Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 2 of 3 FCC 15.247 Test Report High Ch_2480MHz_1MBit_Occupied Bandwidth_- 6dB High Ch_2480MHz_1MBit_Occupied Bandwidth_99 percent Low Ch_2402MHz_2MBit_Occupied Bandwidth_- 6dB Low Ch_2402MHz_2MBit_Occupied Bandwidth_99 percent Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 3 of 3 FCC 15.247 Test Report Mid Ch_2440MHz_2MBit_Occupied Bandwidth_- 6dB Mid Ch_2440MHz_2MBit_Occupied Bandwidth_99 percent High Ch_2480MHz_2MBit_Occupied Bandwidth_- 6dB High Ch_2480MHz_2MBit_Occupied Bandwidth_99 percent

Test Report

Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 1 of 2 FCC 15.247 Test Report Annex B - Maximum Output Power Naming Convention Radio (BLE)_Channel (Low Ch, Mid Ch, High Ch)_Frequency (MHz)_Rate/Mode (MBit)_Measurement (Output Power) BLE_Low Ch_2402MHz_1MBit_Output Power BLE_Low Ch_2402MHz_2MBit_Output Power BLE_Mid Ch_2440MHz_1MBit_Output Power BLE_Mid Ch_2440MHz_2MBit_Output Power Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 2 of 2 FCC 15.247 Test Report BLE_High Ch_2480MHz_1MBit_Output Power BLE_High Ch_2480MHz_2MBit_Output Power

Test Report

Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 1 of 2 FCC 15.247 Test Report Annex C – Power Spectral Density Naming Convention Radio (BLE)_Channel (Low Ch, Mid Ch. High Ch)_Frequency (MHz)_Rate/Mode (MBit)_Measurement (Spectral Density) BLE_Low Ch_2402MHz_1MBit_Spectral Density BLE_Low Ch_2402MHz_2MBit_Spectral Density BLE_Mid Ch_2440MHz_1MBit_Spectral Density BLE_Mid Ch_2440MHz_2MBit_Spectral Density Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 2 of 2 FCC 15.247 Test Report BLE_High Ch_2480MHz_1MBit_Spectral Density BLE_High Ch_2480MHz_2MBit_Spectral Density

Test Report

Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 1 of 3 FCC 15.247 Test Report Annex D – Spurious Emissions at Antenna Terminal and 100 kHz Band Edges Naming Convention Radio (BLE)_Channel (Low Ch, Mid Ch. High Ch)_Frequency (MHz)_Rate/Mode(Mbit)_Measurement (20dBc)_Range (MHz, Lower Band Edge, Upper Band Edge) BLE_Low Ch_2402MHz_1MBit_-20dBc_Lower Band Edge BLE_Low Ch_2402MHz_1MBit_-20dBc_30MHz- 10GHz BLE_Low Ch_2402MHz_1MBit_-20dBc_10-26GHz BLE_Mid Ch_2440MHz_1MBit_-20dBc_30MHz- 10GHz Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 2 of 3 FCC 15.247 Test Report BLE_Mid Ch_2440MHz_1MBit_-20dBc_10-26GHz BLE_High Ch_2480MHz_1MBit_-20dBc_Upper Band Edge BLE_High Ch_2480MHz_1MBit_-20dBc_30MHz- 10GHz BLE_High Ch_2480MHz_1MBit_-20dBc_10-26GHz BLE_Low Ch_2402MHz_2MBit_-20dBc_Lower Band Edge BLE_Low Ch_2402MHz_2MBit_-20dBc_30MHz- 10GHz Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 3 of 3 FCC 15.247 Test Report BLE_Low Ch_2402MHz_2MBit_-20dBc_10-26GHz BLE_Mid Ch_2440MHz_2MBit_-20dBc_30MHz- 10GHz BLE_Mid Ch_2440MHz_2MBit_-20dBc_10-26GHz BLE_High Ch_2480MHz_2MBit_-20dBc_Upper Band Edge BLE_High Ch_2480MHz_2MBit_-20dBc_30MHz- 10GHz BLE_High Ch_2480MHz_2MBit_-20dBc_10-26GHz

Test Report

Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 1 of 3 FCC 15.247 Test Report Annex E – Spurious Emissions 15.209 Note: below measurements are in units of dBuV/m at 3meters. These measurements are performed conducted in lieu of radiated as permitted by ANSI C63.10-2020. The following formula was used in making such conversions: Above 1GHz: E[dBμV/m] = EIRP[dBm] - 20 log (d[m]) + 104.77, where E is field strength and d is distance at which the field strength limit is specified in the applicable requirements. E[dBμV/m] = EIRP[dBm] + 95.2, for d = 3 m. Straight conversion between E[dBuV] and EIRP[dBm] = 107. Thus offset for dBuV/m at 3meters is 95.2-107+antenna gain. Note 1: Additional factors added to offset to consider attenuator + cable loss. Note 2: Declared antenna gain is 1dBi but 2dBi is used as per ANSIC 63.10 section 11.12.2.6. Naming Convention Radio (BLE)_Channel (Low Ch, Mid Ch. High Ch)_Frequency (MHz)_Rate/Mode(Mbit)_Measurement (15.209)_Range (MHz, Lower Band Edge, Upper Band Edge, Peak, Avg) BLE_Low Ch_2402MHz_1MBit_15.209_Lower Band Edge Avg BLE_Low Ch_2402MHz_1MBit_15.209_Lower Band Edge Peak Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 2 of 3 FCC 15.247 Test Report BLE_Low Ch_2402MHz_2MBit_15.209_Lower Band Edge Avg BLE_Low Ch_2402MHz_2MBit_15.209_Lower Band Edge Peak BLE_High Ch_2480MHz_1MBit_15.209_Upper Band Edge Avg BLE_High Ch_2480MHz_1MBit_15.209_Upper Band Edge Peak BLE_High Ch_2480MHz_2MBit_15.209_Upper Band Edge Avg BLE_High Ch_2480MHz_2MBit_15.209_Upper Band Edge Peak Sword Health S.A. FCC ID: 2AQ4A-MB1 Report Number: R2511194-247 Page 3 of 3 FCC 15.247 Test Report The below table applies an additional Duty Cycle Correction Factor (DCCF) to the above Average Band Edge measurements in order to accurately compare to the appropriate limit. Radio Frequency (MHz) Configuration BE (dBuV/m @3m) BE Final (dBuV/m @3m) Limit (dBuV/m @3m) Margin (dB) 2.4 GHz BLE 2402 1 Mbps 45.480 47.548 54 -6.452 2480 45.296 47.364 54 -6.636 2402 2 Mbps 47.030 52.030 54 -1.970 2480 48.577 53.577 54 -0.423 Note: BE = Corrected Band Edge average measurement prior to applying DCCF. Note: BE Final [dBuV/m@3m] = BE + DCCF

Test Report

Ultra-Miniature 2.4GHz Chip antenna 0.37mm max Thickness P/N 2450AT07A0100 Detail Specification:Page 1 of 5 Evaluation Board No. L±± 1 W±± 2 T 3 a 4 b c Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. https://www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 2020 Johanson Technology, Inc. All Rights Reserved P/N Suffix Packing Style "High Frequency Ceramic Solutions" 2W max. (CW) 50 Ω 10/12/2020 Average Gain (dBi typ.) Peak Gain (dBi typ.) Part Number2450AT07A0100 2400 - 2500 1.0 (XZ-Total) Frequency (MHz) 6.5 dB min. 0.014 max -1.5 (XZ-Total) Function Feed Return Loss -40 to +125°C Terminal Configuration Recommended Storage Conditions of unused product on T&R +5 ~ +35 °C Humidity 45~75%RH 18 months max. 0.004 0.004 mmIn 0.50 Mechanical Dimensions Input Power GND GND +0.1/-0.05 Feed+0.1/-0.05 +0.1/-0.05 0.10 0.37 max 0.25 0.08 0.15 Ver 3.1 Operating Temperature General Specifications 1.000.100.039 Impedance 0.003 0.010 +.004/-.006 +.004/-.006 +.004/-.0060.006 0.020 Part Number Explanation 2450AT07A0100-EB1SMA Bulk (loose) Suffix = Se.g. 2450AT07A0100S TraySuffix = Te.g. 2450AT07A0100T 1 2 34 L W a b c T Ultra-Miniature 2.4GHz Chip antenna 0.37mm max Thickness P/N 2450AT07A0100 Detail Specification:Page 2 of 5 Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. https://www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 2020 Johanson Technology, Inc. All Rights Reserved Ver 3.1 "High Frequency Ceramic Solutions" 10/12/2020 Mounting Considerations Test Board-Top View (Units in mm) Land Solder 0.9 4.0 0.4 0.3 0.3 0.7 1.2 0.25 1.5 5.0 3 .0 Feed line Matching circuit No Ground (Yellow area) GND Plane * 0.1 1 23 4 It is recommended that the designer leave available slots for a "pi" (shunt-series-shunt) network. The antenna matching network values above are used when antenna is mounted on Johanson's evaluation board. Matching components will vary depending on PCB design. Let us help you tune our antenna on your new layout, contact our RF Applications Eng. Team at: https://www.johansontechnology.com/ask-a-question *Line width should be designed to maintain 50Ω impedance matching characteristics. Units: mm Ultra-Miniature 2.4GHz Chip antenna 0.37mm max Thickness P/N 2450AT07A0100 Detail Specification:Page 3 of 5 Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. https://www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 2020 Johanson Technology, Inc. All Rights Reserved "High Frequency Ceramic Solutions" 10/12/2020 Ver 3.1 Layout Guidelines and EVB Specifications No ground (Yellow area) Ground Pi matching network recommended Feed 3 5 20 40 Test Board-Top View (Units in mm) 40 20 Ground clearance (Yellow area) 3 5 Test Board-Bottom View (Units in mm) To order a pre-tuned evaluation board with SMA connector click here: https://www.johansontechnology.com/request-a-sample Reference p/n: 2450AT07A0100-EB1SMA To request the layout files go to: https://www.johansontechnology.com/ask-a-question Ground Ultra-Miniature 2.4GHz Chip antenna 0.37mm max Thickness P/N 2450AT07A0100 Detail Specification:Page 4 of 5 Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. https://www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 2020 Johanson Technology, Inc. All Rights Reserved "High Frequency Ceramic Solutions" 10/12/2020 Ver 3.1 Typical Radiation Patterns @25C YZ‐plane XZ‐plane XY‐plane θ +Z (θ= 0°) +Y (θ= 90°) -Y -Z θ +Z (θ= 0°) +X (θ= 90°) -X -Z φ +X (φ= 0°) -X +Y (φ= 90°) -Y +Z +Z +Y +Y +X +X -Y -X -X -Z -Z -Y Ultra-Miniature 2.4GHz Chip antenna 0.37mm max Thickness P/N 2450AT07A0100 Detail Specification:Page 5 of 5 Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. https://www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 2020 Johanson Technology, Inc. All Rights Reserved https://www.johansontechnology.com/tape-reel-packaging https://www.johansontechnology.com/ipcsoldering-profile https://www.johansontechnology.com/rohs-compliance Ver 3.1 "High Frequency Ceramic Solutions" 10/12/2020 Typical Electrical Performance (T=25°C) Packaging information Soldering Information Antenna layout and tuning techniques (How to obtain the new antenna matching values) https://www.johansontechnology.com/tuning Antenna layout review, tuning, and characterization services https://www.johansontechnology.com/ipc-antenna-services RoHS Compliance https://www.johansontechnology.com/msl-rating MSL Info Return Loss / Without Matching Circuits 2.12.22.32.42.52.62.72.82.92.03.0 -20 -15 -10 -5 -25 0 freq, GHz dB(S(1,1)) m1 m2 m3 m1 freq= dB(S(1,1))=-5.100 2.370GHz m2 freq= dB(S(1,1))=-20.709 2.450GHz m3 freq= dB(S(1,1))=-5.437 2.530GHz To download antenna s-parameters, please go to: https://www.johansontechnology.com/antennas

Contact Information

Applicant

Elena Cavllini
[email protected]Fax: +351223248286

Technical Contact

Corporation Service CompanySylvia Buxbaum
[email protected]

1090 Vermont Avenue N.W. · Washington, Dist of Columbia, 20005 · United States

Test Firm

Bay Area Compliance Laboratories Corp.Lisa Tang
[email protected]Fax: 408 732 9164

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.30 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.