2AQ5C-158133-in-1 Wireless Foldable Charging Stand

Hypercel Corporation
3-in-1 Wireless Foldable Charging Stand - FCC ID 2AQ5C-15813 - Hypercel Corporation
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jul 17, 2023
Application Purpose
Original Equipment
Date of Application
Jul 17, 2023
Equipment Note
3-in-1 Wireless Foldable Charging Stand
Frequency Range
0.11010000 - 0.20500000
Company
Hypercel Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WARRANTY ONE YEAR LIMITED FCC STATEMENT : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Attestation Statements

- Hypercel Corporation - The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 7/9/2023 U.S. Agent Designation [Hypercel Corporation] acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: [2AQ5C-15813]): Name and company of U.S. agent: ARGENTO SC BY SICURA INC Physical U. S. address of agent: 420 Sth Avenue 15th Floor New York, New York 10018 United States FRN of U.S. agent: 0031164072 Email address of U.S. agent: [email protected] [ARGENTO SC BY SICURA INC] acknowledges their obligation to accept service of process on behalf of [Hypercel Corporation]. [Hypercel Corporation] with the FRN [0027824093] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanentl y terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm th e above and that we are aware of the application requirements listed under § 2.911(d)(7). Sincerely, Signature [Name] Olivastro Marlene [Title] Executive Assistant [Company] Hypercel Corporation Signature [Name of U.S. agent] Zara Zhou [Title of U.S. agent] Manager [Company of U.S. agent] ARGENTO SC BY SICURA INC 48_[mo del] US_Agent_2.911(d)(7) - U, V04

Attestation Statements

Hypercel Corporation The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 7/9/2023 To whom it may concern: We, [Hypercel Corporation], hereby certify that the equipment for which authorization is sought (FCC ID: [2AQ5C-15813]) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filin g of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist ) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). Sincerely, Signature [Name] Olivastro Marlene [Title] Executive Assistant [Company] Hypercel Corporation 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V02

External Photos

Report No.: AIT23052516FW1 FCC ID: 2AQ5C-15813 Dongguan Yaxu(AiT) Technology Limited 1 / 2 EUT EXTERNAL PHOTOS FRONT VIEW OF EUT REAR VIEW OF EUT Report No.: AIT23052516FW1 FCC ID: 2AQ5C-15813 Dongguan Yaxu(AiT) Technology Limited 2 / 2 LEFT VIEW OF EUT RIGHT VIEW OF EUT --BLANK BELOW--

ID Label/Location Info

Label Location On EUT Label Product Name: 3-in-1 Wireless Foldable Charging Stand Model Number: 15813 Trademark: HYPERGEAR FCC ID: 2AQ5C-15813

Internal Photos

Report No.: AIT23052516FW1 FCC ID: 2AQ5C-15813 Dongguan Yaxu(AiT) Technology Limited 1 / 2 EUT INTERNAL PHOTOS EUT UNCOVER VIEW 1 EUT UNCOVER VIEW2 Inductive loop coil Antenna Report No.: AIT23052516FW1 FCC ID: 2AQ5C-15813 Dongguan Yaxu(AiT) Technology Limited 2 / 2 MAIN BOARD TOP VIEW MAIN BOARD REAR VIEW --BLANK BELOW-- Inductive loop coil Antenna

RF Exposure Info

Page 1 of 13 Report No.: AIT23052516FH1 FCC TEST REPORT Client Information: Applicant: Hypercel Corporation Applicant add.: 28385 Constellation Rd., Valencia, CA 91355 USA. Manufacturer: Hypercel Corporation Manufacturer add.: 28385 Constellation Rd., Valencia, CA 91355 USA. Product Information: Product Name: 3-in -1 Wireless Foldable Charging Stand Model No.: 15813 Brand Name: HYPERGEAR FCC ID: 2AQ5C-15813 Applicable standards: FCC Rules and Regulations part 2.1091 KDB680106 D01v03 Prepared By: Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang,Dongguan, Guangdong, China Tel.: +86-769-8202 0499 Fax.: +86-769-8202 0495 Date of Receipt: May 15, 2023 Date of Test: May 15, 2023 – May 26, 2023 Date of Issue: Jul. 10, 2023 Test Result: Pass This device described above has been tested by Dongguan Yaxu (AiT) Technology Limited and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Note: This report shall not be reproduced except in full, without the written approval of Dongguan Yaxu (AiT) Technology Limited, this document may be altered or revised by Dongguan Yaxu (AiT) Technology Limited, personal only, and shall be noted in the revision of the document. This test report must not be used by the client to claim product endorsement. Reviewed by: Approved by: Simba Huang Seal.chen Page 2 of 13 Report No.: AIT23052516FH1 Contents 1 TEST FACILITY ...................................................................... 3 1.1 Deviation from standard 3 1.2 Abnormalities from standard conditions 3 1.3 Test Location 3 1.4 Environmental conditions 3 2 GENERAL INFORMATION ......................................................... 4 2.1 Product Description 4 2.2 Description of the test mode 5 2.3 Special Accessories 5 2.4 Summary of measurement results 6 2.5 Statement of the measurement uncertainty 6 2.6 Equipments Used during the Test 6 3 TEST CONDITIONS AND RE SULTS ............................................. 7 3.1 Applicable Standard 7 3.2 Limit 7 3.3 Test Setup 8 3.4 Measurement Procedure 8 3.5 Test Result of E and H field Strength 9 3.5.1 For portable exposure .................................................................................................... 9 3.6 Conclusion 10 4 TEST SETUP PHOTOS OF THE EUT .......................................... 11 Page 3 of 13 Report No.: AIT23052516FH1 1 Test Facility The test facility is recognized, certified or accredited by the following organizations: .CNAS- Registration No: L6177 Dongguan Yaxu (AiT) technology Limited is accredited to ISO/IEC 17025:2017 general Requirements for the competence of testing and calibration laboratories (CNAS-CL01 Accreditation Criteria for the competence of testing and calibration laboratories) on April 18, 2022 FCC-Registration No.: 703111 Designation Number: CN1313 Dongguan Yaxu (AiT) technology Limited has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. IC —Registration No.: 6819A CAB identifier: CN0122 The 3m Semi-anechoic chamber of Dongguan Yaxu (AiT) technology Limited has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 6819A A2LA-Lab Cert. No.: 6317.01 Dongguan Yaxu (AiT) technology Limited has been accredited by A2LA for technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing. 1.1 Deviation from standard None 1.2 Abnormalities from standard conditions None 1.3 Test Location Dongguan Yaxu (AiT) Technology Limited Address: No.22, Jinqianling 3rd Street, Jitigang, Huangjiang,Dongguan, Guangdong, China Tel.: +86-769-8202 0499 Fax.: +86-769-8202 0495 1.4 Environmental conditions During the measurement the environmental conditions were within the listed ranges: Temperature: 15-35 ° C Humidity: 30-60 % Atmospheric pressure: 950-1050mbar Page 4 of 13 Report No.: AIT23052516FH1 2 General Information 2.1 Product Description EUT Name: 3-in -1 Wireless Foldable Charging Stand Model No: 15813 Serial Model: N/A Test sample(s) ID: S01, S02 Sample(s) Status: Engineer sample Serial No.: N/A Operation frequency: 110.1-205KHz Modulation Technology: FSK Antenna Type: Inductive loop coil Antenna Antenna gain: 0dBi Hardware version.: N/A Software version.: N/A Power supply: Input: 5V 3A, 9V3A Max Output: 15W Charging Surface Output: 15W/10W/7.5W/5W Charging Pad Output: 5W USB Port Output: 5V 1A Battery: N/A Note: For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. Page 5 of 13 Report No.: AIT23052516FH1 2.2 Description of the test mode Equipment under test was operated during the measurement under the following conditions: Charging and communication mode Test Conditions Test Channel Description TM1 148.3kHz AC/DC Adapter + EUT + Mobile Phone Record TM2 148.3kHz AC/DC Adapter + EUT + AirPods Record TM3 148.3kHz AC/DC Adapter + EUT + Mobile Phone + AirPods + Full Load Record TM4 148.3kHz Test the EUT in idle mode. Pre-tested Note: (1) All test modes were pre-tested, but we only recorded the worst case in this report. (2) All the conditions have been tested. It is found that Wireless Output (20W) work simultaneously is the worst mode, and the data in the report only reflects the worst mode. 2.3 Special Accessories Follow auxiliary equipment(s) test with EUT that provided by the manufacturer or laboratory is listed as follow: Description Manufacturer Model Technical Parameters Certificate Provided by Adapter Salcom V2321 / FCC laboratory Mobile lphone HUAWEI P60 / FCC laboratory AirPods Apple A3953 / FCC laboratory Page …

Text truncated - open the document above for the full version.

Test Report

version01 Hypercel Corporation Declaration concerning Antenna Specification It i s hereby declared that the product Model No.: 15813, E-WL-20-62-XCT FCC ID: 2AQ5C-15813 fulfill s the requirement in FCC test relating to the antenna type. The device specified above confirms to the FCC recommendations for Inductive loop coil Antenna antenna type(s) described below: Model No. of antenna: YM-5838 & SG-A1144-6.6UH Type of antenna: Inductive loop coil Antenna Coil 1: Gain of the antenna: 0 dBi Frequency range: 110.1-205KHz Coil 2: Gain of the antenna: 0 dBi Frequency range: 110.1-205KHz The mounting of the antenna is fixed to the radio module and no other antenna should be used. Company name: Hypercel Corporation Address: 28385 Constellation Rd., City: Valencia ZI P / Postal code: Country: United States Place: Place: Date: 2023-07-10 Signature:

Test Report

客户/Client 名称/TYPE 发射线圈 44MM (环保状况:RoHS+HF ) 产品型号 Model NO SG-A1144-6.6UH 产品编号 SG-A11-030 Part nunbering systey 客户料号 Client p/NO 工程编号 Enginrer NO TQE 1800510003 日期/Date 2021-10-9 编制/Prepared 审核/Checked 认可/Approved DuanJiaWang XieLiang XieXiaoZai 客户认可回签/Authorixed Signaturure Company Chop 工程/ Enginrer 认可/QC APProved 认可日期/APProved 本公司工程部/For Enginer Departner Only 修改内容/Rrvised Content 认可日期/APProved Date 一、 线圈工艺/Winding Procese: NO 绕组 线规 匝数 绕线方向 备注 1 N1 2UEW-B-0. 08 *24P*2 10 TS CCW 2 二.电气性能/FEATURES: 1.测试条件(Test conditions):25°C,65%RH@100KHz/1V 1.1 电感量(Inductance) 1.11 L0A(单独线圈)=3.8uH±20% 1.12 L0A(线圈+磁片)=6.3uH±10% 1.2 Q值=70MIN 1.3 直流电阻(DCR):55mΩ MAX 1.4 工作温度(Operating Temperature):-25°C~85°C 2.测试仪器(Test instrument): L:创达1068+1310;DCR:502BC;SIZE:Callipers 3.材料清单 NO 项目 材料 1 WIRE ¢0.08*24p*2 2UEW-1.0mm 2 FERRITE 43.5*4.7*0.8 L双槽 铁氧体硬磁 3 GLUE 白胶 4 SOLDER XCD-907B 5 Adhesive 双面背胶 6 High temperature adhesive 8MM高温胶带 7 8 三.电路图/CIRCUIT DIAGRAM 单位: MM 四.外形图/OUTSIDE DIAGRA 注:线圈出线位置缠绕8MM(ref)高温胶纸 标准 A B C D E F I T STD 43.5± 1 20.5± 0.5 4.7± 0.5 30±2 2- 5 39±1.2 0.8± 0.2 1.6Max 单位: MM 五.包装/PACKAGE 5.3包装以现有包装盘为参照标准,以实际出货包装为准,如有特需要求可以定制。 The packaging shall be based on the exusting packing plate and the actual delivery package shall prevail .If there is any requirement,we can customize it. 1400 六、贮存和使用条件 Storage and Use condition 6.1 贮存条件 Storage condition 6.1.1 建议贮存条件:温度-25°C~ 85°C ,湿度70% (Max.) Recommended keeping conditions: -25°C ~85°C, 70%RH (Max.) 6.1.2 贮存期限:自生产之日起六个月内 Storage life : Within the limits of six months from being produced. 6.2 使用条件 Use condition 使用条件限制:温度=-25°C~ 85°C, 湿度≤ 90% Use condition limit: T=-25°C~85°C, RH≤ 90%.

Test Report

文檔編號 Document Number 品 名 name of product 產品尺寸 Product Size 粘結方式 Bonding method A19±1.0 B 39.0±1.0 C57±1.0 D37±1.0 E120±3 F4M AX G0.8±0.1 H2.2M AX 線 材 Wire 0.07*100shares 匝 數8 Ts 磁片尺寸 Magnet sheet size 58*Φ 38*0.8L6.5±10% 線圈尺寸 Coil Size Φ 57*37 測試頻率 Test Frequency 100KHZ 測試方式 Test Method 串聯測試 Tandem Test 客 戶 意 見 製錶: 審核 : 備 注 線圈為逆時針 方向 Coil is counterclock wise 丙酮絲包 Acetone kits 確認: 日期:20230517 深圳市永漫数码有限公司 規格書 無線充發射線圈模組 Wireless Charging Coil Module 58*38*H2.2 單位:MM 繞線方式 Winding Method 單線疊繞式 Single Wire Cascade YM-5838

Test Report

Page 1 of 25 Report No.: AIT23052516FW1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China. FCC TEST REPORT Client Information: Applicant: Hypercel Corporation Applicant add.: 28385 Constellation Rd., Valencia, CA 91355 USA. Manufacturer: Hypercel Corporation Manufacturer add.: 28385 Constellation Rd., Valencia, CA 91355 USA. Product Information: Product Name: 3-in -1 Wireless Foldable Charging Stand Model No.: 15813 Brand Name: HYPERGEAR FCC ID: 2AQ5C-15813 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Prepared By: Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang,Dongguan, Guangdong, China Tel.: +86-769-8202 0499 Fax.: +86-769-8202 0495 Date of Receipt: May 15, 2023 Date of Test: May 15, 2023 – May 26, 2023 Date of Issue: Jul. 10, 2023 Test Result: Pass This device described above has been tested by Dongguan Yaxu (AiT) Technology Limited and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Note: This report shall not be reproduced except in full, without the written approval of Dongguan Yaxu (AiT) Technology Limited, this document may be altered or revised by Dongguan Yaxu (AiT) Technology Limited, personal only, and shall be noted in the revision of the document. This test report must not be used by the client to claim product endorsement. Reviewed by: Approved by: Simba Huang Seal.chen Page 2 of 25 Report No.: AIT23052516FW1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China. 1 Contents Page COVER PAGE 1 CONTENTS ........................................................................................................................................................... 2 2 TEST SUMMARY .................................................................................................................................................. 5 2.1 STATEMENT OF THE MEASUREMENT UNCERTAINTY ............................................................................................. 5 2.2 MEASUREMENT UNCERTAINTY ............................................................................................................................ 5 3 TEST FACILITY ..................................................................................................................................................... 6 3.1 DEVIATION FROM STANDARD ............................................................................................................................... 6 3.2 ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................................... 6 3.3 TEST LOCATION ................................................................................................................................................. 6 4 GENERAL INFORMATION ................................................................................................................................... 7 4.1 EUT TEST MODE ............................................................................................................................................... 8 4.2 DESCRIPTION OF TEST SETUP............................................................................................................................. 8 4.3 PERIPHERAL LIST ............................................................................................................................................... 9 4.4 EUT PERIPHERAL LIST ....................................................................................................................................... 9 5 EQUIPMENTS LIST FOR ALL TEST ITEMS ..................................................................................................... 10 6 CONDUCTED EMISSION TEST ......................................................................................................................... 11 6.1 CONDUCTED EMISSION MEASUREMENT ................................................................................................ 11 6.2 POWER LINE CONDUCTED EMISSION LIMITS ........................................................................................... 11 6.3 TEST PROCEDURE ...................................................................................................................................... 11 6.4 DEVIATION FROM TEST STANDARD ......................................................................................................... 11 6.5 TEST SETUP ................................................................................................................................................. 12 6.6 EUT OPERATING CONDITIONS .................................................................................................................. 12 6.7 TEST RESULT .................................................................................................................................................. 13 7 RADIATED EMISSION MEASUREMENT .......................................................................................................... 15 7.1 RADIATED EMISSION LIMITS .............................................................................................................................. 15 7.2 ANECHOIC CHAMBER TEST SETUP DIAGRAM ..................................................................................................... 16 7.3 TEST PROCEDURE ........................................................................................................................................... 16 7.4 DEVIATION FROM TEST STANDARD ......................................................................................................... 16 7.5 TEST RESULT ............................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: AIT23052516FW1 FCC ID: 2AQ5C-15813 Dongguan Yaxu(AiT) Technology Limited 1 / 2 TEST SETUP PHOTOS 1 Radiated Emission Report No.: AIT23052516FW1 FCC ID: 2AQ5C-15813 Dongguan Yaxu(AiT) Technology Limited 2 / 2 2 Conducted Emission --BLANK BELOW--

Contact Information

Applicant

Olivastro Marlene(Executive Assistant)
[email protected]13538218145Fax: 13538218145

Test Firm

Dongguan Yaxu (AiT) Technology LimitedCoin Tang
[email protected]+86 0769-82020499-21

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1101 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Hypercel Corporation

2AQ5C-CTX30KSOL

30000mAh Solar Powerbank

May 15, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2AQ5C-16462

WIRELESS FAST CHARGING MOUNT KIT

Jan 30, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2AQ5C-MGSFWCHRGE

3-IN-1 MAGNETIC WIRELESS CHARGER WITH DUAL USB-C PD OUTPUT

Jan 13, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2AQ5C-16472

WIRELESS FAST CHARGING MOUNT KIT

Dec 23, 2025

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
SoundTower Wireless LED Speaker - FCC ID 2AQ5C-AMZ01 - Hypercel Corporation
2AQ5C-AMZ01

SoundTower Wireless LED Speaker

Jan 01, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter