FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ugreen Group Limited/
  3. 2AQI5-PB567A

2AQI5-PB567AMagnetic Wireless Power Bank

Ugreen Group Limited

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Aug 17, 2026
Application Purpose
Original Equipment
Equipment Note
Magnetic Wireless Power Bank
Frequency Range
0.11100000 - 0.14850000
Company
Ugreen Group Limited
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Ugreen Group Limited Date:01-06-2026 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(5)(i) and Part 2.911(d)(5)(ii) Filing Re. KDB 986446 D01 FCC ID: 2AQI5-PB567A Dear Sir or Madam, [Ugreen Group Limited] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, [Ugreen Group Limited] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. If you have any questions, please contact us. Sincerely, Contact name: Chi Yang Company name: Ugreen Group Limited Address: Ugreen Building, Longcheng Industrial Park Longguanxi Road, Longhua 518000 ShenZhen, PEOPLE`S REPUBLIC OF CHINA E-mail: [email protected] Tel: Manager

Attestation Statements

Ugreen Group Limited Rev 1/26/2023 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 01-13-2026 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2AQI5-PB567A [Ugreen Group Limited] (“the applicant”) certifies that, as of the date of the filing of the application, (America Ugreen Limited) is our designated U.S. agent for service of process for the above referenced FCC ID. [Ugreen Group Limited] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. (America Ugreen Limited) accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: America Ugreen Limited Address: 3828 Kennett Pike, Suite212, Greenville, DE 19807-2331, United States FRN: 0033426180 Contact Person: Morgan Gordon Tel.: +13022062630 Email: [email protected] Sincerely, Company name: Ugreen Group LimitedCompany name: America Ugreen Limited FRN: 0027672971FRN: 0033426180 Contact Name: Chi yangContact Name: Morgan Gordon Title: ManagerTitle: Authorized Officer SignatureSignature

Cover Letter(s)

Ugreen Group Limited Date (01/06/2026) TUV SUD BABT UNLIMITED TCB Octagon House, Segensworth North, Fareham, Hampshire, PO15 5RL, United Kingdom Confidentiality Request FCC ID: 2AQI5-PB567A Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, (Ugreen Group Limited) hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation] (Ugreen Group Limited) also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of 180 days: Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Chi Yang Telephone Number: 0755-28198930 Email: [email protected]

Cover Letter(s)

Ugreen Group Limited Date: 01-06-2026 To: Federal Communications Commission 7435 Oakland Mills Road Columbia MD FCC ID: 2AQI5-PB567A To Whom It May Concern: This letter is to ascertain that Ugreen Group Limited Product name: Wireless Bluetooth headphones, Model: E66 has been the units used for conducting FCC compliance testing, the SDoC part will be tested by FCC recognized test lab. If you have any question or concerns, please contact us. Sincerely, Contact name: Chi Yang Company name: Ugreen Group Limited Address: Ugreen Building, Longcheng Industrial Park Longguanxi Road, Longhua 518000 ShenZhen, PEOPLE`S REPUBLIC OF CHINA E-mail: [email protected] Tel: Manager

ID Label/Location Info

水平翻转 面盖丝印方向参考 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, in- cluding interference that may cause undesired operation. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. A A A A

RF Exposure Info

- Page 1 of 14 - Report No.: HB20250919052E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com RF EXPOSURE Test Report Product: Magnetic Wireless Power Bank Trade Mark: Model Number: PB567 FCC ID: 2AQI5-PB567A Prepared for Ugreen Group Limited Ugreen Building, Longcheng Industrial Park, Longguanxi Road, Longhua, 518000 Shenzhen, PEOPLE'S REPUBLIC OF CHINA. Prepared by Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen, China Tel.: +86-755-2998 9321 Fax.: +86-755-2998 5110 Website: http://www.sz-hongbiao.com - Page 2 of 14 - Report No.: HB20250919052E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Table of Contents 1 GENERAL DESCRIPTION ..................................................................................................................................... 5 1.1 DESCRIPTION OF EUT.......................................................................................................................................... 5 1.2 TEST MODE ...................................................................................................................................................... 5 1.3 TEST SETUP ...................................................................................................................................................... 6 1.4 ANCILLARY EQUIPMENT ....................................................................................................................................... 6 2 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 7 2.1 TEST LABORATORY .............................................................................................................................................. 7 2.2 ENVIRONMENTAL CONDITIONS .............................................................................................................................. 7 2.3 MEASUREMENT UNCERTAINTY ............................................................................................................................... 7 2.4 TEST SOFTWARE................................................................................................................................................. 7 3 LIST OF TEST EQUIPMENT .................................................................................................................................. 8 4 RF EXPOSURE..................................................................................................................................................... 9 4.1 MAXIMUM PERMISSIBLE EXPOSURE ........................................................................................................................ 9 4.1.1. Limit ..................................................................................................................................................... 9 4.1.2. Test Procedures ..................................................................................................................................... 9 4.1.3. Test Setup ............................................................................................................................................10 4.1.4. Test Result ...........................................................................................................................................10 - Page 3 of 14 - Report No.: HB20250919052E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com TEST RESULT CERTIFICATION Applicant’s Name ................. : Ugreen Group Limited Address ................................. : Ugreen Building, Longcheng Industrial Park, Longguanxi Road, Longhua, 518000 Shenzhen, PEOPLE'S REPUBLIC OF CHINA. Manufacturer's Name .......... : Ugreen Group Limited Address ................................. : Ugreen Building, Longcheng Industrial Park, Longguanxi Road, Longhua, 518000 Shenzhen, PEOPLE'S REPUBLIC OF CHINA. Product description Product name ........................ : Magnetic Wireless Power Bank Model Number ....................... : PB567 Standards ............................. : FCC CFR 47 PART 1 , 1.1310 Test procedure ....................... : KDB 680106 D01 Wireless Power Transfer v04 This device described above has been tested by Shenzhen HongBiao Certification& Testing Co., Ltd and the test results show that the equipment under test (EUT) is in compliance with the EMC requirements. And it is applicable only to the tested sample identified in the report. Date of Test.......................................... : Date (s) of performance of tests ............. : Sept. 19, 2025~Sept. 28, 2025 Test Result ............................................ : Pass Testing Engineer : ( Z o e Su) Technical Manager : (Ha n s M o u) Authorized Signatory : (L e o S u) - Page 4 of 14 - Report No.: HB20250919052E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Revision History Revised No. Date of Issue Description 01 Sept. 28, 2025 Original - Page 5 of 14 - Report No.: HB20250919052E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fa…

Text truncated - open the document above for the full version.

Test Report

Report Number: 6895025176101 EMC_SZ_FR_23.03 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 27 FCC - TEST REPORT Report Number : 6895025176101 Date of Issue: 2026-06-30 Model : PB567 Product Type : Magnetic Wireless Power Bank Applicant : Ugreen Group Limited Address : Ugreen Building, Longcheng Industrial Park Longguanxi Road, Longhua 518000 ShenZhen, PEOPLE`S REPUBLIC OF CHINA Manufacturer : Ugreen Group Limited Address : Ugreen Building, Longcheng Industrial Park Longguanxi Road, Longhua 518000 ShenZhen, PEOPLE`S REPUBLIC OF CHINA Factory : Shenzhen Firstar Battery Co., Limited Address : Building 3 and Building 5, Jinxiu Industrial Park, Xitian Community, Gongming Sub-district, Guangming District, 518106 Shenzhen City, PEOPLE'S REPUBLIC OF CHINA. Test Result : ◼ Positive  Negative Total pages including Appendices : 27 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 6895025176101 EMC_SZ_FR_23.03 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 27 1 Table of Contents 1 Table of Contents ............................................................................................................................................................... 2 2 Details about the Test Laboratory .................................................................................................................................... 3 3 Description of the Equipment Under Test ....................................................................................................................... 4 4 Summary of Test Standards ............................................................................................................................................. 5 5 Summary of Test Results .................................................................................................................................................. 6 6 General Remarks ............................................................................................................................................................... 7 7 Test Setups ......................................................................................................................................................................... 8 8 Systems test configuration ................................................................................................................................................ 9 9 Technical Requirement .................................................................................................................................................... 10 9.1 Conducted Emission Test .......................................................................................................................................... 10 9.2 20 dB Bandwidth .......................................................................................................................................................... 15 9.3 Radiated Emission Test .............................................................................................................................................. 17 10 Test Equipment List ......................................................................................................................................................... 26 11 System Measurement Uncertainty ................................................................................................................................. 27 Report Number: 6895025176101 EMC_SZ_FR_23.03 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 27 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: Company Address: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu,Nantou, Nanshan District, Shenzhen, Guangdong, China Telephone: +86 755 8828 6998 Fax: +86 755 8828 5299 FCC Registration No.: 174744 FCC Designation Number: CN5009 Report Number: 6895025176101 EMC_SZ_FR_23.03 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 27 3 Description of the Equipment Under Test Product: Magnetic Wireless Power Bank Model no.: PB567 P/N Code: 55450, 55450P, 55450X, 55450A, 55450B, 55450C, 55450U, 55450JP, 55450ZD FCC ID: 2AQI5-PB567A Rating: USB-C(IN1) / USB-C Cable(IN2) Input: 5.0V⎓3.0A, 9.0V⎓3.0A, 12.0V⎓2.5A, 15.0V⎓2.0A; USB-C(OUT1) / USB-C Cable(OUT2) Output: 10.0V⎓2.25A, 5.0V⎓2.4A, 5.0V⎓3.0A, 9.0V⎓3.0A, 12.0V⎓2.5A, 15.0V⎓2.0A; USB-A(OUT3) Output: 10.0V⎓2.25A, 5.0V⎓2.4A, 5.0V⎓3.0A, 9.0V⎓2.0A, 12.0V⎓ 1.5A; Wireless Charging Output: 15.0W Max; Total Output: 5.0V⎓1.5A+5.0W; Total Cell Capacity: 20000mAh; Battery Capacity: 10000mAh(Two Cells in Series); Rated Capacity: 11300mAh(TYP 5V2.4A); Polymer Lithium-ion Battery Rated Energy: 72.0Wh, 7.2V RF Tr…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Chi Yang(Manager)
[email protected]Fax: +86-755-2818 8194

Test Firm

TUV SUD Certification and Testing (China) Co., LtdHarry Zhou
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.111 MHz - 0.1485 MHz-
215C0.36 MHz - 0.36 MHz-
Confidentiality
Long Term

Other Applications from Ugreen Group Limited

2AQI5-WM701

Wireless Car Charger

Aug 01, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2AQI5-W723

Magnetic Wireless Charger

Jul 20, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
UGREEN FineTrack MagCards - FCC ID 2AQI5-FT505 - Ugreen Group Limited
2AQI5-FT505

UGREEN FineTrack MagCards

Jun 25, 2026

Equipment Class

DTS - Digital Transmission System
2AQI5-PB775B

Magnetic Wireless Power Bank

Jun 22, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2AQI5-W777

3-in-1 Wireless Charger

Jun 18, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz