2AQQARXDOCKGDockmate Receiver

PPA-Electronics b.v.b.a
Dockmate Receiver - FCC ID 2AQQARXDOCKG - PPA-Electronics b.v.b.a
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jan 27, 2021
Application Purpose
Original Equipment
Date of Application
Jan 27, 2021
Equipment Note
Dockmate Receiver
Frequency Range
433.08100000 - 434.75700000
Company
PPA-Electronics b.v.b.a
Country
Belgium

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

4 V30 DOCKMATE, single-handed wireless remote control over your boat. Installation manual 2 Dockmate is a registered trademark from PPA-Electronics B.V. Leuvensesteenweg 177 – BE-3191 Boortmeerbeek – Belgium VAT BE 0891.773.260 – Tel. +32 (0)15 43 39 94 – Mob. +32 (0)475 45 37 35 [email protected] – www.dockmate.eu – [email protected] – www.ppa-electronics.com 3 Dockmate is a registered trademark from PPA-Electronics B.V. Leuvensesteenweg 177 – BE-3191 Boortmeerbeek – Belgium VAT BE 0891.773.260 – Tel. +32 (0)15 43 39 94 – Mob. +32 (0)475 45 37 35 [email protected] – www.dockmate.eu – [email protected] – www.ppa-electronics.com 1. Safety precautions Before installing the Dockmate, read all the manuals carefully. Before starting any work on the installation of the Dockmate, make sure the boat is very well moored on strong and tight ropes. The Dockmate should be installed by a trained and qualified engineer only. FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encoura ged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by the manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. 4 Dockmate is a registered trademark from PPA-Electronics B.V. Leuvensesteenweg 177 – BE-3191 Boortmeerbeek – Belgium VAT BE 0891.773.260 – Tel. +32 (0)15 43 39 94 – Mob. +32 (0)475 45 37 35 [email protected] – www.dockmate.eu – [email protected] – www.ppa-electronics.com 1.1. Preparing the transmitter 1.1.1. TWIN/SINGLE Transmitter Testing the battery: - Press and hold down the HORN button; the green LED will light up. - After about 2,5 seconds, the LED will turn off and you have to release the HORN button. - The green LED will start to flash and the buzzer will start to sound (providing that the Receiver is off), indicating that it is trying to communicate with the Receiver. o If the battery is still (sufficiently) charged, the red battery status LED (on the right) will remain off. o If the battery voltage is (critically) low, after 3 seconds the red battery status LED will start blinking for about 30s. => This means the battery has to be charged. o If the battery voltage is too low, then there will be no reaction on the transmitter at all (no LEDs or buzzer). => This means the battery has no charge left at all and needs to be charged. When the transmitter is switched off, only the HORN button will be able to switch it on. Pressing any other button will have no effect. To charge a TWIN or SINGLE transmitter place it on the charging pad. The red battery status LED should start blinking. The charger will also indicate that it is charging. Troubleshooting the charger: If after 1 minute on the charger the red battery status LED still isn’t blinking: - Check if the charger is on; if so continue to the next step - Check the battery status (see “test the batteries” procedure above) o If you’re able to turn on the transmitter but the red battery status LED remains off when testing the battery, then the battery is completely full. o If you’re able to turn on the transmitter and the red battery status LED blinks for 30s, then there might be something wrong with the charger o If you’re unable to turn on the transmitter and it won’t charge either, please contact your Dockmate dealer. 5 Dockmate is a registered trademark from PPA-Electronics B.V. Leuvensesteenweg 177 – BE-3191 Boortmeerbeek – Belgium VAT BE 0891.773.260 – Tel. +32 (0)15 43 39 94 – Mob. +32 (0)475 45 37 35 [email protected] – www.dockmate.eu – [email protected] – www.ppa-electronics.com 1.1.2. TWIST Transmitter Press the key for 1 second to turn on the transmitter. The transmitter will be automatically switched off after 30 minutes of non use. Alternatively the transmitter can be switched off by pressing 3 times the button or holding it down for 3 sec. After the transmitter is switched on, both LEDs will go white. Then the LINK light will go dark and the STATUS LED will show one of following: Battery fully charged More than 3.90V Battery OK Between 3.45V and 3.90V Battery Warning Between 3.30V and 3.45V Battery Failed Less than 3.30V Then it will go dark and the LINK light will show the communication status: Communication OK, actively transmitting data When moving the joystick or pressing a button Communication OK, standby mode When not moving the joystick or pressing any button for more than 15s Yellow / Green Blinking Receiver status warning. For example CAN bus interface not in command Purple / Green Blinking Receiver status error. For example CAN bus interface not powered …

Text truncated - open the document above for the full version.

Cover Letter(s)

<PPA-Electronics b.v.b.a> Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2020-12-31 Subject; Request for Confidentiality FCC ID: 2AQQARXDOCKG To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: DIRK L ILLEGEMS Title: CEO

Cover Letter(s)

PPA-Electronics b.v.b.a Letter of Authorization Company: PPA-Electronics b.v.b.a Address: FAID’HERBESTRAAT 3A, MECHELEN, 2800, Belgium Product Name: Dockmate Receiver Model Number: Receiver rev.G, Dockmate Receiver rev.G FCC Identifier: 2AQQARXDOCKG We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: DIRK L ILLEGEMS Date: 2020-12-31 Title: CEO Signature of applicant:

External Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG 1. EXTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Fig. 3 Fig. 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Fig. 5 Fig. 6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Fig. 7 Fig. 8 Antenna SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Fig. 9 Antenna Port

ID Label/Location Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 LABEL AND LOCATION Size: L5.5cm*W3.5cm

Internal Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG 1. INTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Fig. 3 Fig. 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Fig. 5 Fig. 6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Fig. 7 Fig. 8 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Fig. 9 Fig. 10 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Fig. 11 Fig. 12 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Fig. 13 Fig. 14

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Report No.: LCS201117013AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 29 FCC TEST REPORT For PPA-Electronics b.v.b.a Dockmate Receiver Test Model: Receiver rev.G Additional Model No.: Dockmate Receiver rev.G Prepared for : PPA-Electronics b.v.b.a Address : FAID’HERBESTRAAT 3A, MECHELEN, 2800, Belgium Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : November 17, 2020 Number of tested samples : 1 Serial number : Prototype Date of Test : November 17, 2020 ~ December 31, 2020 Date of Report : December 31, 2020 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Report No.: LCS201117013AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 29 FCC TEST REPORT FCC CFR 47 PART 15C(15.231) Report Reference No. ................. : LCS201117013AEA Date of Issue ................................... : December 31, 2020 Testing Laboratory Name ............. : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Bao’an District, Shenzhen, Guangdong, China Testing Location/ Procedure ........... : Full application of Harmonised standards â–  Partial application of Harmonised standards â–ˇ Other standard testing method â–ˇ Applicant’s Name .......................... : PPA-Electronics b.v.b.a Address ........................................... : FAID’HERBESTRAAT 3A, MECHELEN, 2800, Belgium Test Specification Standard .......................................... : FCC CFR 47 PART 15 Subpart C Test Report Form No. ..................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : Dockmate Receiver Trade Mark ...................................... : Dockmate Test Model ...................................... : Receiver rev.G Ratings ............................................ : DC 12V 1A Result ............................................ : Positive Compiled by: Supervised by: Approved by: Lh Li/ Administrators Jin Wang/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Report No.: LCS201117013AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 29 FCC TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS201117013AEA December 31, 2020 Date of issue Test Mode............................... : Receiver rev.G EUT........................................ : Dockmate Receiver Applicant............................... : PPA-Electronics b.v.b.a Address.................................. : FAID’HERBESTRAAT 3A, MECHELEN, 2800, Belgium Telephone.............................. : / Fax......................................... : / Manufacturer........................ : PPA-Electronics b.v.b.a Address.................................. : FAID’HERBESTRAAT 3A, MECHELEN, 2800, Belgium Telephone............................... : / Fax......................................... : / Factory.................................. : PPA-Electronics b.v.b.a Address................................... : FAID’HERBESTRAAT 3A, MECHELEN, 2800, Belgium Telephone.............................. : / Fax......................................... : / SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Report No.: LCS201117013AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 29 Revision History Revision Issue Date Revisions Revised By 000 December 31, 2020 Initial Issue Gavin Liang SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Report No.: LCS201117013AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 29 TABLE OF CONTENTS 1. GENERAL INFORMATION ................................................................................................................................... 6 1.1. DESCRIPTION OF DEVICE (EUT) ........................................................................................................................ 6 1.2. OBJECTIVE .......................................................................................................................................................... 6 1.3. ENVIRONMENTAL CONDITIONS ........................................................................................................................... 6 1.4. HOST SYSTEM CONFIGURATION LIST AND DETAILS .......................................................................................... 6 1.5. EXTERNAL I/O PORT ......…

Text truncated - open the document above for the full version.

Test Setup Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQQARXDOCKG Report No.: LCS201117013AEA _______________________________________________________________________________________________ 1. TEST SETUP PHOTOGRAPHS 1.1. Photo of Radiated Emissions Measurement Fig. 1 Fig. 2

Contact Information

Applicant

DIRK LOUIS ILLEGEMS(Mr.)
[email protected]+32475453735Fax: +32475453735

Technical Contact

PPA-Electronics b.v.b.a
[email protected]

Belgium

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.081 MHz - 434.757 MHz-
Confidentiality
Long Term

Other Applications from PPA-Electronics b.v.b.a

Dockmate TWIST (wireless remote control) - FCC ID 2AQQATXDOCKF - PPA-Electronics b.v.b.a
2AQQATXDOCKF

Dockmate TWIST (wireless remote control)

Jan 26, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter