FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Globe Electric Company Inc./
  3. 2AQUQGB35798

2AQUQGB35798LED bulb

Globe Electric Company Inc.
LED bulb - FCC ID 2AQUQGB35798 - Globe Electric Company Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 02, 2022
Application Purpose
Original Equipment
Date of Application
Jul 01, 2022
Equipment Note
LED bulb
Frequency Range
2422.00000000 - 2452.00000000
Company
Globe Electric Company Inc.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

+86-1-382-525-3712 Cet appareil contient des émetteurs / récepteurs exemptés de licence conformes aux RSS (RSS)d'Innovation, Sciences et Développement économique Canada. Le fonctionnement est soumis aux deux conditions suivantes : (1) Cet appareil ne doit pas causer d'interférences. (2) Cet appareil doit accepter toutes les interférences, y compris celles susceptibles de provoquer un fonctionnement indésirable de l'appareil.

Cover Letter(s)

2022.6.30 FederalCommunicationsCommission Authorization&EvaluationDivision 7345OaklandMillsRoad Columbia,Maryland21046 AuthoritytoActasAgent Onourbehalf,Iappoint BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd./BuildingC,No.107, ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen,GuangdongProvince,China (NameofAgentcompanynameandaddress)toactasouragentinthepreparationofthis applicationforequipmentcertification.Icertifythatsubmitteddocumentsproperlydescribe thedeviceorsystemforwhichequipmentcertificationissought.Ialsocertifythateach unitmanufactured,importedormarketed,asdefinedintheFederalCommunications Commission’sregulationswillhaveaffixedtoitalabelidenticaltothatsubmittedfor approvalwiththisapplication. Forinstanceswhereourauthorizedagentsignstheapplicationforcertificationonour behalf,Iacknowledgethatallresponsibilityforcomplyingwiththetermsandconditions forcertification,stillresideswith GlobeElectricCompanyInc./150Oneida,Montreal,Quebec, Canada,H9R1A8(ApplicantNameandaddress) <Signature> Name:Celine Title:SeniorProjectManager Company:GlobeElectricCompanyInc.

Cover Letter(s)

2022.7.1 EquipmentAutorisationDivision FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 FCCID:2AQUQGB35798 ProductName:LEDbulb RequestforConfidentiality PursuanttoSections0.457and0.459ofthecommission’srules,weherebyrequestthat thefollowingdocumentsbeheldconfidential: (Listherethedocumentsforwhichyouareseekingconfidentiality–forexample...) Schematics Blockdiagram  Operationdescription Thesematerialscontaintradesecretsandproprietaryinformationandarenot customarilyreleasedtothepublic.Thepublicdisclosureofthisinformationmightbe harmfultothecompanyandprovideunjustifiedbenefitstoourcompetitors. Signature Name : Celine Title:TechnicalDirector Company:SeniorProjectManager

External Photos

ProductName: LEDbulb

ID Label/Location Info

Label location

Internal Photos

ProductName: LEDbulb

RF Exposure Info

Page 1 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Add:BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen,GuangdongProvince,China Tel:+86-755-23059481Email:[email protected] TESTREPORT ProductName: LEDbulb BrandMark: Globe ModelNo.: 35798 ReportNumber: BLA-EMC-202206-A6703 FCCID: 2AQUQGB35798 DateofSampleReceipt: 2022/6/16 DateofTest: 2022/6/20to2022/7/1 DateofIssue: 2022/7/1 TestStandard: 47CFRPart1.1307,Part1.1310 TestResult:Pass Preparedfor: GlobeElectricCompanyInc. 150Oneida,Montreal,Quebec,Canada,H9R1A8 Preparedby: BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict, Shenzhen,GuangdongProvince,China TEL:+86-755-23059481 Compiledby:Reviewby: Approvedby:Date:2022/7/1 ReportNo.:BLA-EMC-202206-A6703 Page 2 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] REPORTREVISERECORD VersionNo.DateDescription 002022/7/1Original ReportNo.:BLA-EMC-202206-A6703 Page 3 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] TABLEOFCONTENTS 1TESTSUMMARY........................................................................................................................................4 2GENERALINFORMATION.........................................................................................................................5 3GENERALDESCRIPTIONOFE.U.T..........................................................................................................5 4LABORATORYLOCATION.........................................................................................................................6 5RFEXPOSURECOMPLIANCEREQUIREMENT......................................................................................7 5.1LIMITS........................................................................................................................................................................7 5.2TESTPROCEDURE..........................................................................................................................................................7 5.3EUTRFEXPOSUREEVALUATION.....................................................................................................................................8 ReportNo.:BLA-EMC-202206-A6703 Page 4 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 1TESTSUMMARY TestitemTestRequirementTestMethodClass/SeverityResult RFExposure 47CFRPart 1.1307,Part 1.1310 CFR47Part 1.1310 CFR47Part1.1310PASS ReportNo.:BLA-EMC-202206-A6703 Page 5 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 2GENERALINFORMATION ApplicantGlobeElectricCompanyInc. Address150Oneida,Montreal,Quebec,Canada,H9R1A8 ManufacturerNingboYamaoOptoelectronicsCo.,Ltd Address #88EastZhongxingRoad,XikouTown,Ningbo,Zhejiang,China 315502 FactoryNingboYamaoOptoelectronicsCo.,Ltd Address #88EastZhongxingRoad,XikouTown,Ningbo,Zhejiang,China 315502 ProductNameLEDbulb TestModelNo.35798 3GENERALDESCRIPTIONOFE.U.T. HardwareVersionV1.0.1 SoftwareVersionV1.3.21 PowersupplyAC120V BLE OperationFrequency:2402MHz-2480MHz ModulationType:GFSK ChannelSpacing:2MHz NumberofChannels:40 AntennaType:InternalAntenna AntennaGain:1.2dBi(Providedbytheapplicant) 2.4GWIFI OperationFrequency: 802.11b/g/n(HT20):2412MHzto2462MHz 802.11n(HT40):2422MHzto2452MHz ModulationType: 802.11b:DSSS(CCK,DQPSK,DBPSK) 802.11g/n:OFDM(64QAM,16QAM,QPSK,BPSK) ChannelSpacing:5MHz NumberofChannels: 802.11b/g/n(HT20):11 802.11n(HT40):7 AntennaType:InternalAntenna AntennaGain:1.2dBi(Providedbytheapplicant) ReportNo.:BLA-EMC-202206-A6703 Page 6 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 4LABORATORYLOCATION Alltestswereperformedat: BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen,GuangdongProvince, China Telephone:TEL:+86-755-28682673FAX:+86-755-28682673 Notestsweresub-contracted. ReportNo.:BLA-EMC-202206-A6703 Page 7 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 5RFEXPOSURECOMPLIANCEREQUIREMENT 5.1LIMITS AccordingtoFCCPart1.1310:Thecriterialistedinthefollowingtableshallbeusedto evaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF)radiationas specifiedinpart1.1307(b) F=FrequencyinMHz FriisFormula Friistransmissionformula:Pd=(Pout*G)/(4*Pi*R2) Where Pd=powerdensityinmW/cm2 Pout=outputpowertoantennainmW G=gainofantennainlinearscale Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm2.Ifweknowthemaximumgainoftheantennaandthe totalpowerinputtotheantenna,throughthecalculation,wewillknowthedistancer wheretheMPElimitisreached. 5.2TESTPROCEDURE SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. ReportNo.:BLA-EMC-202206-A6703 Page 8 of 8 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 5.3EUTRFEXPOSUREEVALUATION AntennaGain:1.2dBi AntennaGain:ThemaximumGainmeasuredinfullyanechoicchamberis1.318inlinear scale. OutputPowerIntoAntenna&RFExposureEvaluationDistance: BLE: Channel Frequency (MHz) MaxConducted PeakOutput Power(dBm) OutputPower toAntenna (mW) PowerDensity atR=20cm (mW/cm 2 ) LimitResult middle2440-1.61 0.6900.0002 1.0PASS WIFI(802.11b): Channel Frequency (MHz) MaxConducted PeakOutput Power(dBm) OutputPower toAntenna (mW) PowerDensity atR=20cm (mW/cm 2 ) LimitResult lowest24127.272 5.3360.0014 1.0PASS Note:RefertoreportNo.BLA-EMC-202206-A6701/02forEUTtestMaxConductedPeakOutputPowervalue. Thedistancer(4thcolumn)calculatedfromtheFriestransmissionformulaisfargreaterthan 20cmseparationRequirement ----ENDOFREPORT---- T…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 66 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Add:BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen,GuangdongProvince,China Tel:+86-755-23059481Email:[email protected] TESTREPORT ProductName: LEDbulb BrandMark: Globe ModelNo.: 35798 ReportNumber: BLA-EMC-202206-A6701 FCCID: 2AQUQGB35798 DateofSampleReceipt: 2022/6/16 DateofTest: 2022/6/20to2022/7/1 DateofIssue: 2022/7/1 TestStandard: 47CFRPart15,SubpartC15.247 TestResult:Pass Preparedfor: GlobeElectricCompanyInc. 150Oneida,Montreal,Quebec,Canada,H9R1A8 Preparedby: BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict, Shenzhen,GuangdongProvince,China TEL:+86-755-23059481 Compiledby:Reviewby: Approvedby:Date:2022/7/1 ReportNo.:BLA-EMC-202206-A6701 Page 2 of 66 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] REPORTREVISERECORD VersionNo.DateDescription 002022/7/1Original ReportNo.:BLA-EMC-202206-A6701 Page 3 of 66 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] TABLEOFCONTENTS 1TESTSUMMARY........................................................................................................................................5 2GENERALINFORMATION.........................................................................................................................6 3GENERALDESCRIPTIONOFE.U.T..........................................................................................................6 4TESTENVIRONMENT................................................................................................................................7 5TESTMODE................................................................................................................................................7 6MEASUREMENTUNCERTAINTY..............................................................................................................7 7DESCRIPTIONOFSUPPORTUNIT..........................................................................................................8 8LABORATORYLOCATION.........................................................................................................................8 9TESTINSTRUMENTSLIST........................................................................................................................9 10CONDUCTEDEMISSIONSATACPOWERLINE(150KHZ-30MHZ).....................................................12 10.1LIMITS................................................................................................................................................................12 10.2BLOCKDIAGRAMOFTESTSETUP......................................................................................................................12 10.3PROCEDURE.......................................................................................................................................................12 10.4TESTDATA...........................................................................................................................................................14 11CONDUCTEDBANDEDGESMEASUREMENT.....................................................................................16 11.1LIMITS................................................................................................................................................................16 11.2BLOCKDIAGRAMOFTESTSETUP......................................................................................................................16 11.3TESTDATA...........................................................................................................................................................17 12RADIATEDSPURIOUSEMISSIONS........................................................................................................18 12.1LIMITS................................................................................................................................................................18 12.2BLOCKDIAGRAMOFTESTSETUP......................................................................................................................19 12.3PROCEDURE.......................................................................................................................................................19 12.4TESTDATA...........................................................................................................................................................21 13RADIATEDEMISSIONSWHICHFALLINTHERESTRICTEDBANDS.................................................29 13.1LIMITS................................................................................................................................................................29 13.2BLOCKDIAGRAMOFTESTSETUP......................................................................................................................30 13.3PROCEDURE.......................................................................................................................................................30 13.4TESTDATA...........................................................................................................................................................32 14CONDUCTEDSPURIOUSEMISSIONS...................................................................................................36 14.1LIMITS................................................................................................................................................................36 ReportNo.:BLA-EMC-202206-A6701 Page 4 of 66 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 14.2BLOCKDIAGRAMOFTESTSETUP......................................................................................................................36 14.3TESTDATA...…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 107 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Add:BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen,GuangdongProvince,China Tel:+86-755-23059481Email:[email protected] TESTREPORT ProductName: LEDbulb BrandMark: Globe ModelNo.: 35798 ReportNumber: BLA-EMC-202206-A6702 FCCID: 2AQUQGB35798 DateofSampleReceipt: 2022/6/16 DateofTest: 2022/6/20to2022/7/1 DateofIssue: 2022/7/1 TestStandard: 47CFRPart15,SubpartC15.247 TestResult:Pass Preparedfor: GlobeElectricCompanyInc. 150Oneida,Montreal,Quebec,Canada,H9R1A8 Preparedby: BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict, Shenzhen,GuangdongProvince,China TEL:+86-755-23059481 Compiledby:Reviewby: Approvedby:Date:2022/7/1 ReportNo.:BLA-EMC-202206-A6702 Page 2 of 107 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] REPORTREVISERECORD VersionNo.DateDescription 002022/7/1Original ReportNo.:BLA-EMC-202206-A6702 Page 3 of 107 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] TABLEOFCONTENTS 1TESTSUMMARY........................................................................................................................................5 2GENERALINFORMATION.........................................................................................................................6 3GENERALDESCRIPTIONOFE.U.T..........................................................................................................6 4TESTENVIRONMENT................................................................................................................................7 5TESTMODE................................................................................................................................................7 6MEASUREMENTUNCERTAINTY..............................................................................................................7 7DESCRIPTIONOFSUPPORTUNIT..........................................................................................................8 8LABORATORYLOCATION.........................................................................................................................8 9TESTINSTRUMENTSLIST........................................................................................................................9 10ANTENNAREQUIREMENT......................................................................................................................12 10.1CONCLUSION.........................................................................................................................................................12 11RADIATEDSPURIOUSEMISSIONS........................................................................................................13 11.1LIMITS................................................................................................................................................................13 11.2BLOCKDIAGRAMOFTESTSETUP......................................................................................................................14 11.3PROCEDURE.......................................................................................................................................................14 11.4TESTDATA...........................................................................................................................................................16 12RADIATEDEMISSIONSWHICHFALLINTHERESTRICTEDBANDS.................................................24 12.1LIMITS................................................................................................................................................................24 12.2BLOCKDIAGRAMOFTESTSETUP......................................................................................................................25 12.3PROCEDURE.......................................................................................................................................................25 12.4TESTDATA...........................................................................................................................................................27 13CONDUCTEDSPURIOUSEMISSIONS...................................................................................................43 13.1LIMITS................................................................................................................................................................43 13.2BLOCKDIAGRAMOFTESTSETUP......................................................................................................................43 13.3TESTDATA...........................................................................................................................................................44 14CONDUCTEDBANDEDGESMEASUREMENT.....................................................................................45 14.1LIMITS................................................................................................................................................................45 14.2BLOCKDIAGRAMOFTESTSETUP......................................................................................................................45 14.3TESTDATA...........................................................................................................................................................46 ReportNo.:BLA-EMC-202206-A6702 Page 4 of 107 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 15MINIMUM6DBBANDWIDTH...................................................................................................................47 15.1LIMITS..............................................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

ProductName: LEDbulb ConductedEmissionsatACPowerLine(150kHz-30MHz) RadiatedSpuriousEmissions

Contact Information

Applicant

Celine Zhu(Senior Project Manager)
[email protected]+86-755-25192522Fax: 755 8225 7770

Test Firm

BlueAsia of Technical Services (Shenzhen)Blue Zheng
[email protected]+86 755-23059481-815

Technical Specifications

#Rule PartsFrequency RangePower Output
315C2.42 GHz - 2.45 GHz2.86 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. This device has a 20 MHz and 40 MHz bandwidth mode.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Globe Electric Company Inc.

2AQUQGB34204A

A19 LED bulb

Dec 02, 2024

Equipment Class

DTS - Digital Transmission System
2AQUQGE30495

SMART PLUG

Sep 26, 2024

Equipment Class

DTS - Digital Transmission System
2AQUQGE50867

Smart Plug

Sep 08, 2024

Equipment Class

DTS - Digital Transmission System
2AQUQGB50589

A19 LED bulb

Aug 20, 2024

Equipment Class

DTS - Digital Transmission System
2AQUQGE370623

Ceiling fan

Jun 27, 2024

Equipment Class

DTS - Digital Transmission System