FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Globe Electric Company Inc./
  3. 2AQUQGE50348

2AQUQGE50348Smart Blind Controller

Globe Electric Company Inc.
Smart Blind Controller - FCC ID 2AQUQGE50348 - Globe Electric Company Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 05, 2021
Application Purpose
Original Equipment
Date of Application
Apr 29, 2021
Equipment Note
Smart Blind Controller
Frequency Range
2402.00000000 - 2480.00000000
Company
Globe Electric Company Inc.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

IC STATEMENT This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. The distance between user and products should be no less than 20cm Cet appareil contient des émetteurs / récepteurs exemptés de licence conformes aux RSS (RSS)d'Innovation, Sciences et Développement économique Canada. Le fonctionnement est soumis aux deux conditions suivantes : (1) Cet appareil ne doit pas causer d'interférences. (2) Cet appareil doit accepter toutes les interférences, y compris celles susceptibles de provoquer un fonctionnement indésirable de l'appareil. La distance entre l'utilisateur et de produits ne devrait pas être inférieure à 20cm

Cover Letter(s)

DATE 2021/4/19 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AQUQGE50348 Product Name: Smart Blind Controller Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...) Schematics Block diagram  Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature> Name CelineZhu Title Seniorprojectmanager Company GlobeElectricCompanyInc.

External Photos

Model No.: 50348

Internal Photos

Model No.: 50348

RF Exposure Info

Page 1 of 2 Product Name: Smart Blind Controller Model No.:50348 FCC ID:2AQUQGE50348 RF Exposure Evaluation 1.1 RF Exposure Compliance Requirement 1.1.1 Limits According to FCC Part1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in part1.1307(b) F= Frequency in MHz Friis Formula Friis transmission formula: Pd = (Pout*G)/(4* Pi * R 2) Where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. 1.1.2 Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. 1.1.3 EUT RF Exposure Evaluation Antenna Gain:2.5dBi BLE: Channel Frequency (MHz) Max Conducted Peak Output Power (dBm) Output Power to Antenna (mW) Power Density at R = 20 cm (mW/cm 2 ) Limit Result lowest 2402 5.74 3.74973 0.00133 1.0 PASS 2.4G WIFI: 802.11b Channel Frequency (MHz) Max Conducted Peak Output Power (dBm) Output Power to Antenna (mW) Power Density at R = 20 cm (mW/cm 2 ) Limit Result lowest 2462 16.68 46.55861 0.01647 1.0 PASS Note: Refer to report No. BLA-EMC-202103-A11001/03 for EUT test Max Conducted Peak Output Power value. The distance (4th column) calculated from the Fries transmission formula is far greater than 20 cm separation Requirement Page 2 of 2

Test Report

Report No.: BLA-EMC-202103-A11001 Page 63 of68 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com APPENDIX A: PHOTOGRAPHS OF TEST SETUP Radiated Emissions which fall in the restricted bands Conducted Emissions at AC Power Line (150kHz-30MHz) Report No.: BLA-EMC-202103-A11001 Page 64 of68 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Radiated Spurious Emissions Report No.: BLA-EMC-202103-A11001 Page 65 of68 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com APPENDIX B: PHOTOGRAPHS OF EUT Report No.: BLA-EMC-202103-A11001 Page 66 of68 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Report No.: BLA-EMC-202103-A11001 Page 67 of68 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Report No.: BLA-EMC-202103-A11001 Page 68 of68 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com ----END OF REPORT---- The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of BlueAsia, this report can’t be reproduced except in full.

Test Report

Report No.: BLA-EMC-202103-A11003 Page 101 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com APPENDIX A: PHOTOGRAPHS OF TEST SETUP Conducted Emissions at AC Power Line (150kHz-30MHz) Report No.: BLA-EMC-202103-A11003 Page 102 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Radiated Spurious Emissions Report No.: BLA-EMC-202103-A11003 Page 103 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com APPENDIX B: PHOTOGRAPHS OF EUT Report No.: BLA-EMC-202103-A11003 Page 104 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Report No.: BLA-EMC-202103-A11003 Page 105 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Report No.: BLA-EMC-202103-A11003 Page 106 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Report No.: BLA-EMC-202103-A11003 Page 107 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Report No.: BLA-EMC-202103-A11003 Page 108 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com ----END OF REPORT---- The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of BlueAsia, this report can’t be reproduced except in full.

Test Report

Report No.: BLA-EMC-202103-A11003 Page 65 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 10 APPENDIX Appendix1 10.1 APPENDIXA: DTS BANDWIDTH Test Result TestMode Antenna Channel DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11B Ant1 2412 9.080 2407.400 2416.480 >=0.5 PASS 2437 8.560 2432.960 2441.520 >=0.5 PASS 2462 9.160 2457.400 2466.560 >=0.5 PASS 11G Ant1 2412 16.440 2403.760 2420.200 >=0.5 PASS 2437 16.440 2428.760 2445.200 >=0.5 PASS 2462 16.440 2453.760 2470.200 >=0.5 PASS 11N20SISO Ant1 2412 17.640 2403.160 2420.800 >=0.5 PASS 2437 17.640 2428.160 2445.800 >=0.5 PASS 2462 17.640 2453.160 2470.800 >=0.5 PASS Report No.: BLA-EMC-202103-A11003 Page 66 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Report No.: BLA-EMC-202103-A11003 Page 67 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11G_Ant1_2412 11G_Ant1_2437 Report No.: BLA-EMC-202103-A11003 Page 68 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 Report No.: BLA-EMC-202103-A11003 Page 69 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11N20SISO_Ant1_2462 Report No.: BLA-EMC-202103-A11003 Page 70 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 10.2 APPENDIXB: OCCUPIED CHANNEL BANDWIDTH Test Result TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11B Ant1 2412 14.040 2404.946 2418.986 --- PASS 2437 14.049 2429.927 2443.976 --- PASS 2462 14.033 2454.947 2468.980 --- PASS 11G Ant1 2412 17.260 2403.342 2420.602 --- PASS 2437 17.227 2428.332 2445.559 --- PASS 2462 17.221 2453.336 2470.557 --- PASS 11N20SISO Ant1 2412 18.303 2402.844 2421.147 --- PASS 2437 18.093 2427.945 2446.038 --- PASS 2462 18.247 2452.895 2471.142 --- PASS Report No.: BLA-EMC-202103-A11003 Page 71 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Report No.: BLA-EMC-202103-A11003 Page 72 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11G_Ant1_2412 11G_Ant1_2437 Report No.: BLA-EMC-202103-A11003 Page 73 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 Report No.: BLA-EMC-202103-A11003 Page 74 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11N20SISO_Ant1_2462 Report No.: BLA-EMC-202103-A11003 Page 75 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 10.3 APPENDIXC: MAXIMUM CONDUCTED OUTPUT POWER Test Result TestMode Antenna Channel Result[dBm] Limit[dBm] Verdict 11B Ant1 2412 16.59 <=30 PASS 2437 16.52 <=30 PASS 2462 16.68 <=30 PASS 11G Ant1 2412 12.79 <=30 PASS 2437 13.03 <=30 PASS 2462 13.32 <=30 PASS 11N20SISO Ant1 2412 13.00 <=30 PASS 2437 12.99 <=30 PASS 2462 13.22 <=30 PASS Report No.: BLA-EMC-202103-A11003 Page 76 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Report No.: BLA-EMC-202103-A11003 Page 77 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11G_Ant1_2412 11G_Ant1_2437 Report No.: BLA-EMC-202103-A11003 Page 78 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 Report No.: BLA-EMC-202103-A11003 Page 79 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11N20SISO_Ant1_2462 Report No.: BLA-EMC-202103-A11003 Page 80 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 10.4 APPENDIXD: MAXIMUM POWER SPECTRAL DENSITY Test Result TestMode Antenna Channel Result[dBm/3-100kHz] Limit[dBm/3kHz] Verdict 11B Ant1 2412 -9.34 <=8 PASS 2437 -9.82 <=8 PASS 2462 -9.84 <=8 PASS 11G Ant1 2412 -15.49 <=8 PASS 2437 -15.28 <=8 PASS 2462 -14.15 <=8 PASS 11N20SISO Ant1 2412 -14.87 <=8 PASS 2437 -15.34 <=8 PASS 2462 -15.19 <=8 PASS Report No.: BLA-EMC-202103-A11003 Page 81 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Report No.: BLA-EMC-202103-A11003 Page 82 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11G_Ant1_2412 11G_Ant1_2437 Report No.: BLA-EMC-202103-A11003 Page 83 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 Report No.: BLA-EMC-202103-A11003 Page 84 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11N20SISO_Ant1_2462 Report No.: BLA-EMC-202103-A11003 Page 85 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 10.5 APPENDIXE:BAND EDGE MEASUREMENTS Test Result TestMode Antenna ChName Ch…

Text truncated - open the document above for the full version.

Test Report

Report No.: BLA-EMC-202103-A11003 Page 41 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202103-A11003 Page 42 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202103-A11003 Page 43 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202103-A11003 Page 44 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202103-A11003 Page 45 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com RADIATED EMISSIONS WHICH FALL IN THE RESTRICTED BANDS Test Standard 47 CFR Part 15, Subpart C 15.247 Test Method ANSI C63.10 (2013) Section 6.10.5 Test Mode (Pre-Scan) TX Low channel;TX high channel Test Mode (Final Test) TX Low channel;TX high channel Tester Jozu Temperature 25°C Humidity 60% LIMITS Frequency(MHz) Field strength(microvolts/meter) Measurement distance(meters) 0.009-0.490 2400/F(kHz) 300 0.490-1.705 24000/F(kHz) 30 1.705-30.0 30 30 30-88 100 3 88-216 150 3 216-960 200 3 Above 960 500 3 Remark: The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9-90kHz, 110-490kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector, the peak field strength of any emission shall not exceed the maximum permitted average limits specified above by more than 20 dB under any condition of modulation. Report No.: BLA-EMC-202103-A11003 Page 46 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com BLOCK DIAGRAM OF TEST SETUP PROCEDURE a. For below 1GHz, the EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 or 10 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position of the highest radiation. b. For above 1GHz, the EUT was placed on the top of a rotating table 1.5 meters above the ground at a 3 meter fully-anechoic chamber. The table was rotated 360 degrees to determine the position of the highest radiation. c. The EUT was set 3 or 10 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. d. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. e. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters (for the test frequency of below 30MHz, the antenna was tuned to heights 1 meter) and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading. f. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. g. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet. Report No.: BLA-EMC-202103-A11003 Page 47 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com h. Test the EUT in the lowest channel, the middle channel, the Highest channel. i. The radiation measurements are performed in X, Y, Z axis positioning for Transmitting mode, and found the X axis positioning which it is the worst case. j. Repeat above procedures until all frequencies measured was complete. Remark 1: Level= Read Level+ Cable Loss+ Antenna Factor- Preamp Factor Remark 2: For frequencies above 1GHz, the field strength limits are based on average limits. However, the peak field strength of any emission shall not exceed the maximum permitted average limits specified above by more than 20 dB under any condition of modulation. For the emissions whose peak level is lower than the average limit, only the peak measurement is shown in the report. Report No.: BLA-EMC-202103-A11003 Page 48 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com TEST DATA [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202103-A11003 Page 49 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202103-A11003 Page 50 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202103-A11003 Page 51 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202103-A11003 Page 52 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202103-A11003 Page 53 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202103-A11003 Page…

Text truncated - open the document above for the full version.

Test Report

Page 1 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Add: Building C, No. 107, Shihuan Road, Shiyan Sub-District, Baoan District, Shenzhen, Guangdong Province, China Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com TEST REPORT Product Name : Smart Blind Controller Brand Mark : Globe Model No. : 50348 Report Number : BLA-EMC-202103-A11003 Date of Sample Receipt : 2021/3/25 Date of Test : 2021/4/22 to 2021/4/25 Date of Issue : 2021/4/25 FCC ID : 2AQUQGE50348 Test Standard : 47 CFR Part 15, Subpart C 15.247 Test Result : Pass Prepared for: Globe Electric Company Inc 150, Oneida, Montreal, Quebec, Canada, H9R 1A8 Prepared by: BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Building C, No. 107, Shihuan Road, Shiyan Sub-District, Baoan District, Shenzhen, Guangdong Province, China TEL: +86-755-23059481 Compiled by: Review by: Approved by: Date: 2021/4/25 Report No.: BLA-EMC-202103-A11003 Page 2 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com REPORT REVISE RECORD Version No. Date Description 00 2021/4/25 Original Report No.: BLA-EMC-202103-A11003 Page 3 of108 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com TABLE OF CONTENTS 1 TEST SUMMARY ........................................................................................................................................6 2 GENERAL INFORMATION .........................................................................................................................7 3 GENERAL DESCRIPTION OF E.U.T. .........................................................................................................7 4 TEST ENVIRONMENT ................................................................................................................................8 5 TEST MODE ................................................................................................................................................8 6 MEASUREMENT UNCERTAINTY ..............................................................................................................8 7 DESCRIPTION OF SUPPORT UNIT...........................................................................................................9 8 LABORATORY LOCATION .........................................................................................................................9 9 TEST INSTRUMENTS LIST ..................................................................................................................... 10 CONDUCTED PEAK OUTPUT POWER .......................................................................................................... 14 LIMITS ............................................................................................................................................................................. 14 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 14 TEST DATA ........................................................................................................................................................................ 15 CONDUCTED EMISSIONS AT AC POWER LINE (150KHZ-30MHZ) ............................................................. 16 LIMITS ............................................................................................................................................................................. 16 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 16 PROCEDURE ................................................................................................................................................................... 16 TEST DATA ........................................................................................................................................................................ 18 ANTENNA REQUIREMENT .............................................................................................................................. 20 CONCLUSION ...................................................................................................................................................................... 20 POWER SPECTRUM DENSITY ....................................................................................................................... 21 LIMITS ............................................................................................................................................................................. 21 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 21 TEST DATA ........................................................................................................................................................................ 21 RADIATED SPURIOUS EMISSIONS ............................................................................................................... 22 LIMITS ............................................................................................................................................................................. 22 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 23 PROCEDURE ................................................................................................................................................................... 23 TEST DATA ........................................................................................................................................................................ 25 Report No.: BLA-E…

Text truncated - open the document above for the full version.

Test Report

Page 1 of68 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Add: Building C, No. 107, Shihuan Road, Shiyan Sub-District, Baoan District, Shenzhen, Guangdong Province, China Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com TEST REPORT Product Name : Smart Blind Controller Brand Mark : Globe Model No. : 50348 Report Number : BLA-EMC-202103-A11001 Date of Sample Receipt : 2021/3/25 Date of Test : 2021/4/22 to 2021/4/25 Date of Issue : 2021/4/25 FCC ID : 2AQUQGE50348 Test Standard : 47 CFR Part 15, Subpart C 15.247 Test Result : Pass Prepared for: Globe Electric Company Inc. 150, Oneida, Montreal, Quebec, Canada, H9R 1A8 Prepared by: BlueAsia of Technical Services(Shenzhen) Co.,Ltd. Building C, No. 107, Shihuan Road, Shiyan Sub-District, Baoan District, Shenzhen, Guangdong Province, China TEL: +86-755-23059481 Compiled by: Review by: Approved by: Date: 2021/4/25 Report No.: BLA-EMC-202103-A11001 Page 2 of68 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com REPORT REVISE RECORD Version No. Date Description 00 2021/4/25 Original Report No.: BLA-EMC-202103-A11001 Page 3 of68 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com TABLE OF CONTENTS 1 TEST SUMMARY ........................................................................................................................................6 2 GENERAL INFORMATION .........................................................................................................................7 3 GENERAL DESCRIPTION OF E.U.T. .........................................................................................................7 4 TEST ENVIRONMENT ................................................................................................................................8 5 TEST MODE ................................................................................................................................................8 6 MEASUREMENT UNCERTAINTY ..............................................................................................................8 7 DESCRIPTION OF SUPPORT UNIT...........................................................................................................9 8 LABORATORY LOCATION .........................................................................................................................9 9 TEST INSTRUMENTS LIST ..................................................................................................................... 10 RADIATED EMISSIONS WHICH FALL IN THE RESTRICTED BANDS ......................................................... 13 LIMITS ............................................................................................................................................................................. 13 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 14 PROCEDURE ................................................................................................................................................................... 14 TEST DATA ........................................................................................................................................................................ 16 CONDUCTED EMISSIONS AT AC POWER LINE (150KHZ-30MHZ) ............................................................. 20 LIMITS ............................................................................................................................................................................. 20 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 20 PROCEDURE ................................................................................................................................................................... 20 TEST DATA ........................................................................................................................................................................ 22 CONDUCTED BAND EDGES MEASUREMENT ............................................................................................. 24 LIMITS ............................................................................................................................................................................. 24 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 24 TEST DATA ........................................................................................................................................................................ 25 RADIATED SPURIOUS EMISSIONS ............................................................................................................... 26 LIMITS ............................................................................................................................................................................. 26 BLOCK DIAGRAM OF TEST SET…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Celine Zhu(Senior Project Manager)
[email protected]+86-755-25192522Fax: 755 8225 7770

Test Firm

BlueAsia of Technical Services (Shenzhen)Blue Zheng
[email protected]+86 755-23059481-815

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.40 GHz - 2.48 GHz3.75 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Globe Electric Company Inc.

2AQUQGB34204A

A19 LED bulb

Dec 02, 2024

Equipment Class

DTS - Digital Transmission System
2AQUQGE30495

SMART PLUG

Sep 26, 2024

Equipment Class

DTS - Digital Transmission System
2AQUQGE50867

Smart Plug

Sep 08, 2024

Equipment Class

DTS - Digital Transmission System
2AQUQGB50589

A19 LED bulb

Aug 20, 2024

Equipment Class

DTS - Digital Transmission System
2AQUQGE370623

Ceiling fan

Jun 27, 2024

Equipment Class

DTS - Digital Transmission System