Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: Globe Electric FRN: 0033436957 Contact Name: Celine Zhu Address: 2264 East 6th Street, San Bernardino, CA 92410, United States Telephone No: (514) 694-0444 Email: [email protected] Applicant: Company name: Globe Electric Company Inc. Product Description: RGB Beacon Smart Strip Light Grantee code: 2AQUQ FCC ID: 2AQUQGE50618A Contact Name: Celine Zhu Address: 150 Oneida, Montreal, Quebec, Canada, H9R 1A8 Telephone No: +86-755-25192522 Email: [email protected] [Globe Electric Company Inc.] certifies that, as of the date of this filing of the application with the TCB, [Globe Electric] is our designated US agent for service of process for the above referenced FCC ID. [Globe Electric Company Inc.] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [Globe Electric] accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 2023/08/18 Applicant’s Name:CelineZhuUS Agent ’s Name:CelineZhu Title: SeniorProjectManagerTitle: SeniorProjectManager Signature:Signature:
C5266091_X24_Ed.2 1/1 “AttestationStatements” TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 TheCommissionadoptedrulesthatprohibitequipmentauthorizationfor“covered” telecommunicationsequipmentandvideosurveillanceequipmentproducedbyentitiesidentified ontheCommission’sCoveredList 1 ,whichisperiodicallyupdated.SeetheCoveredListformore details.ThisAttestationStatementistoconfirmthatwefollowtheSection2.911(d)(5)(i)-(ii) Applicant Companyname:GlobeElectricCompanyInc. Granteecode:2AQUQ FCCID:2AQUQGE50618A ContactName:CelineZhu Address:150Oneida,Montreal,Quebec,Canada,H9R1A8 TelephoneNo:+86-755-25192522 FaxNo:75582257770 Email:[email protected] i.GlobeElectricCompanyInc.(“theapplicant”)certifiesthattheequipmentfor whichauthorizationissoughtisnot“covered”equipmentprohibitedfrom receivinganequipmentauthorizationpursuanttosection2.903oftheFCC rules.Theapplicantmustsignthiscertification. ii.GlobeElectricCompanyInc.(“theapplicant”)certifiesthat,asofthedateof thefilingoftheapplication,theapplicantisnot(asaspecificallynamed entityoranyofitssubsidiariesoraffiliates)identifiedontheCoveredListas anentityproducing“covered”equipment.Theapplicantmustsignthis certification. GlobeElectricCompanyInc.(“theapplicant”)certifiesthat,asofthedateofthe filingoftheapplication,theapplicantisnotidentifiedontheCoveredListasan entityproducing“covered”equipment. Date:2023/08/18 Applicant’sName:CelineZhu Title:SeniorProjectManager Signature 1 TheCommission’sCoveredListispublishedbythePublicSafetyandHomelandSecurityBureauandpostedonthe Commission’swebsite.ThisCoveredList,whichisperiodicallyupdated,identifiesparticularequipment,producedby particularentities,thatconstitutes“covered”equipment.https://www.fcc.gov/supplychain/coveredlist
C5266091_X8_Ed.1 1/1 LetterofAuthorization GlobeElectricCompanyInc. Company:GlobeElectricCompanyInc. Address:150Oneida,Montreal,Quebec,Canada,H9R1A8 ProductName:RGBBeaconSmartStripLight ModelNumber:50618* FCCIdentifier:2AQUQGE50618A WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:CelineZhuDate:2023/08/18 Title:SeniorProjectManager Signatureofapplicant:
C5266091_X10_Ed.1 1/1 GlobeElectricCompanyInc. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2 023/08/18 Subject:RequestforConfidentiality FCCID:2AQUQGE50618A ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo BlockDiagram Schematics TestReportNoNo TestSetupPhotosNo User’sManual InternalPhotos PartsList/TuneUp RFExposureInfo OperationalDescription CoverLetter(s)NoNo SDRSoftware/SecurityInfoNo Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselectedabove arewithheldfrompublicviewforaperiodof_180_daysfromthedateoftheGrantof EquipmentAuthorizationandpriortomarketing. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, Signature: Name:CelineZhu Title:SeniorProjectManager
GlobeElectricCompanyInc. 150Oneida,Montreal,Quebec,Canada,H9R1A8 DATE:08/18/2023 GlobeElectricCompanyInc. 150Oneida,Montreal,Quebec,Canada,H9R1A8 Attn:DirectorofCertification AuthoritytoActasAgent Onourbehalf,Iappointbelowcompanyandperson: NameDamonHu PositionManager CompanyNameDongguanDongdianTestingServiceCo.,Ltd. Address17,ZongbuRoad2,SongshanLakeSci&Tech,IndustryPark, DongguanCity,GuangdongProvince,China,523808 Tel/Fax Tel:+86-0769-38826678-850 [email protected] toactasouragentinthepreparationofthisapplicationforequipmentcertification.I certifythatsubmitteddocumentsproperlydescribethedeviceorsystemforwhich equipmentcertificationissought.Ialsocertifythateachunitmanufactured,importedor marketed,asdefinedintheFederalCommunicationsCommission’sregulationswill haveaffixedtoitalabelidenticaltothatsubmittedforapprovalwiththisapplication. ApplicantnameGlobeElectricCompanyInc. Address150Oneida,Montreal,Quebec,Canada,H9R1A8 Yourssincerely, NameCelineZhu PositionSeniorProjectManager CompanyNameGlobeElectricCompanyInc. Address150Oneida,Montreal,Quebec,Canada,H9R1A8 Tel/Fax+86-755-25192522/75582257770 [email protected]
Dongguan Dongdian Testing Service Co., Ltd. Case No.: DDT-Q23072835-2E Page 1 of 8 AppendixI: Photos of the EUT Product Name: RGB Beacon Smart Strip Light Model Number: 50618* Dongguan Dongdian Testing Service Co., Ltd. Case No.: DDT-Q23072835-2E Page 2 of 8 Dongguan Dongdian Testing Service Co., Ltd. Case No.: DDT-Q23072835-2E Page 3 of 8 Dongguan Dongdian Testing Service Co., Ltd. Case No.: DDT-Q23072835-2E Page 4 of 8 Dongguan Dongdian Testing Service Co., Ltd. Case No.: DDT-Q23072835-2E Page 5 of 8
EJB0823 50618* FCCID: 2AQUQGE50618A IC: 8290A-GE50618A 68mm 24.6 121313 9.2 7 4.5 14.3 14.3 20.5
Dongguan Dongdian Testing Service Co., Ltd. Case No.: DDT-Q23072835-2E Page 6 of 8 Dongguan Dongdian Testing Service Co., Ltd. Case No.: DDT-Q23072835-2E Page 7 of 8 Antenna Dongguan Dongdian Testing Service Co., Ltd. Case No.: DDT-Q23072835-2E Page 8 of 8 END
Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-RE23072835-2E02 Page 1 of 7 RF EXPOSURE REPORT FOR Issued By: Dongguan Dongdian Testing Service Co., Ltd. Add.: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City, Guangdong Province, China, 523808 Tel.: +86-0769-38826678, E-mail: [email protected], http://www.dgddt.com Applicant : Globe Electric Company Inc. Address : 150 Oneida, Montreal, Quebec, Canada, H9R 1A8 Equipment under Test : RGB Beacon Smart Strip Light Model No. : 50618* Trade Mark : Globe FCC ID : 2AQUQGE50618A Manufacturer : Globe Electric Company Inc. Address : 150 Oneida, Montreal, Quebec, Canada, H9R 1A8 Report No.: DDT-RE23072835-2E02 Issued Date: Aug. 16, 2023 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-RE23072835-2E02 Page 2 of 7 Table of Contents Test report declares.......................................................................................................3 1. General Information .................................................................................................................. 5 1.1. Description of equipment ......................................................................................................... 5 1.2. Assess laboratory ..................................................................................................................... 5 2. RF Exposure Evaluation .......................................................................................................... 6 2.1. Requirement .............................................................................................................................. 6 2.2. Calculation method ................................................................................................................... 6 2.3. Estimation result ....................................................................................................................... 7 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-RE23072835-2E02 Page 3 of 7 Test Report Declare Standard Used: KDB447498 D01 General RF Exposure Guidance v06 We Declare: The equipment described above is assessed by Dongguan Dongdian Testing Service Co., Ltd. and in the configuration assessed the equipment complied with the standards specified above. The assessed results are contained in this report and Dongguan Dongdian Testing Service Co., Ltd. is assumed of full responsibility for the accuracy and completeness of these assess. After evaluation, our opinion is that the equipment In Accordance with above standard. Report No: DDT-RE23072835-2E02 Date of Receipt: Aug. 03, 2023 Date of Test: Aug. 03, 2023 ~ Aug. 16, 2023 Prepared By: Approved By: ________________ ______________________ Tiger Mo/Engineer Damon Hu/EMC Manager Note: This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Dongguan Dongdian Testing Service Co., Ltd. Applicant : Globe Electric Company Inc. Address : 150 Oneida, Montreal, Quebec, Canada, H9R 1A8 Equipment under Test : RGB Beacon Smart Strip Light Model No. : 50618* Trade mark : Globe Manufacturer : Globe Electric Company Inc. Address : 150 Oneida, Montreal, Quebec, Canada, H9R 1A8 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-RE23072835-2E02 Page 4 of 7 Revision History Rev. Revisions Issue Date Revised By --- Initial issue Aug. 16, 2023 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-RE23072835-2E02 Page 5 of 7 1. General Information 1.1. Description of equipment 1.2. Assess laboratory Dongguan Dongdian Testing Service Co., Ltd. Add.: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City, Guangdong Province, China, 523808. Tel.: +86-0769-38826678, http://www.dgddt.com, Email: [email protected]. CNAS Accreditation No. L6451; A2LA Accreditation Number: 3870.01 FCC Designation Number: CN1182, Test Firm Registration Number: 540522 Innovation, Science and Economic Development Canada Site Registration Number: 10288A Conformity Assessment Body identifier: CN0048 VCCI facility registration number: C-20087, T-20088, R-20123, R-20155, G-20118 EUT* Name : RGB Beacon Smart Strip Light Model Number : 50618* EUT function description : Please reference user manual of this device Power Supply : DC 5V From external adapter Radio Specification : Bluetooth V5.0 Operation Frequency : 2402 MHz - 2480 MHz Modulation : GFSK Data Rate : 1 Mbps Antenna Gain : PCB antenna, Maximum PK gain: 0.89 dBi Serial Number : S23072835-02 for conductive S23072835-03 for radiation Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-RE23072835-2E02 Page 6 of 7 2. RF Exposure Evaluation 2.1. Requirement Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2 m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. Limits for General Population/Uncontrolled Exposure 2.2. Calculation method From the peak EUT RF output power, the minimum mobile separation distance, d= 0.2 m, as well as the gain of the used antenna, the RF power density can be obtained. Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-RE23072835-2E02 Page 7 of 7 2.3. Estimation result Mode PK Output power (dBm) Output power (mW) tune up power (dBm) Antenna Gain (dBi) Antenna Gain (linear) MPE Values (mW/cm 2 ) MPE Limit (mW/cm 2 ) BLE -2.65 0.54 -2.00 0.89 1.23 0.0001 1 Note: The estimation distance is 20 cm Conclusion: The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of mobile device. END OF REPORT
ANTENNA REPORT Manufacture:TUYA Product Name:PHY6252 Antenna Antenna Type:PCB Test Date: 2020.04.15 Tested by:Irene Approved by:Licco Content 1.GeneralDescription.................................................................................1 2.TestConfigurations...................................................................................2 2.1TestEnvironment............................................................................2 2.2TestEquipment...............................................................................2 2.3TestPrinciple...................................................................................2 3.TestResults..............................................................................................3 3.1GainandEfficiency..........................................................................3 3.2RadiationPattern............................................................................4 4.AntennaDimensions................................................................................5 5.EUTPhoto................................................................................................5 6.TestSetupPhoto......................................................................................6 1 1.General Description ManufacturerHangzhou Tuya Information Technology Co.,Ltd Address Room 701,Building 3,More Center,No.87 GuDun Road, Hangzhou, Zhejiang,China Test Location Room 106, Building 3, Letong Science Park, No. 500, Qiuyi Road, Binjiang District, Hangzhou Product NamePHY6252 Antenna Product model PHY6252 Antenna Type PCBAntenna Test Items Gain; Efficiency; Radiation Pattern Test Frequency 2400-2500MHz Test Standard ANSI/IEEE Std 149-1979 2 2.TestConfigurations 2.1TestEnvironment Temperature(°C)25 Humidity(%RH)60 AtmosphericPressure(kPa)100.5 2.2TestEquipment TestSystemTEM24Multi-probeMicrowaveChamber TestInstrumentAgilentE5071B 2.3TestPrinciple 3 3.TestResults 3.1GainandEfficiency Frequency(MHz)PeakGain(dBi)Efficiency(%) 2400 -0.1723.33 2410 0.0624.6 2420 0.3426.12 2430 0.5428.05 2440 0.8930.55 2450 0.8730.76 2460 0.7930.55 2470 0.7630.2 2480 0.7530.13 2490 0.7929.99 2500 0.5827.73 4 3.2RadiationPattern 2400MHz3D 2450MHz3D 2500MHz3D 5 4.Antenna Dimensions 5.EUT Photo 6 6.TestSetupPhoto
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-RE23072835-2E01 TRF No.: FCC Part 15C and RSS-247 BLE Ver.1.0 Page 1 of 57 FCC AND ISED CERTIFICATION TEST REPORT FOR Issued By: Dongguan Dongdian Testing Service Co., Ltd. Add.: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City, Guangdong Province, China, 523808 Tel.: +86-0769-38826678, E-mail: [email protected], http://www.dgddt.com Applicant : Globe Electric Company Inc. Address : 150 Oneida, Montreal, Quebec, Canada, H9R 1A8 Equipment under Test : RGB Beacon Smart Strip Light Model No. : 50618* Trade Mark : Globe FCC ID : 2AQUQGE50618A IC : 8290A-GE50618A Manufacturer : Globe Electric Company Inc. Address : 150 Oneida, Montreal, Quebec, Canada, H9R 1A8 Report No.:DDT-RE23072835-2E01 Issued Date: Aug. 16, 2023 Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-RE23072835-2E01 TRF No.: FCC Part 15C and RSS-247 BLE Ver.1.0 Page 2 of 57 Table of Contents Test report declares.......................................................................................................4 1. Summary of Test Results ............................................................................................... 6 2. General Test Information ............................................................................................... 7 2.1. Description of EUT ......................................................................................................... 7 2.2. Accessories of EUT ........................................................................................................ 7 2.3. Assistant equipment used for test .................................................................................. 7 2.4. Block diagram of EUT configuration for test .................................................................. 8 2.5. Test environment conditions .......................................................................................... 8 2.6. Deviations of test standard............................................................................................. 8 2.7. Test laboratory ............................................................................................................... 8 2.8. Measurement uncertainty ............................................................................................... 9 3. Equipment Used During Test ....................................................................................... 10 4. 6 dB Bandwidth ............................................................................................................ 11 4.1. Block diagram of test setup .......................................................................................... 11 4.2. Limits ............................................................................................................................ 11 4.3. Test procedure ............................................................................................................. 11 4.4. Test result ..................................................................................................................... 12 4.5. Test graphs .................................................................................................................. 12 5. 99% Bandwidth ............................................................................................................ 14 5.1. Block diagram of test setup .......................................................................................... 14 5.2. Limits ............................................................................................................................ 14 5.3. Test procedure ............................................................................................................. 14 5.4. Test Result ................................................................................................................... 14 5.5. Test Graphs .................................................................................................................. 15 6. Maximum Peak Output Power ..................................................................................... 16 6.1. Block diagram of test setup .......................................................................................... 16 6.2. Limits ............................................................................................................................ 16 6.3. Test procedure ............................................................................................................. 16 6.4. Test result ..................................................................................................................... 17 6.5. Test graphs .................................................................................................................. 17 7. Power Spectral Density ................................................................................................ 19 7.1. Block diagram of test setup .......................................................................................... 19 7.2. Limits ............................................................................................................................ 19 7.3. Test procedure ............................................................................................................. 19 7.4. Test result ..................................................................................................................... 20 7.5. Test graphs .................................................................................................................. 20 Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-RE23072835-2E01 TRF No.: FCC Part 15C and RSS-247 BLE Ver.1.0 Page 3 of 57 8. Band Edge Compliance (Conducted Method) ............................................................. 22 8.1. Block diagram of test setup .......................................................…
Text truncated - open the document above for the full version.
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-RE23072835-2E01 TRF No.: FCC Part 15C and RSS-247 BLE Ver.1.0 Page 55 of 57 15. Test Setup Photograph Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-RE23072835-2E01 TRF No.: FCC Part 15C and RSS-247 BLE Ver.1.0 Page 56 of 57
Dongguan · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 500.00 µW |
A19 LED bulb
Equipment Class
DTS - Digital Transmission SystemSMART PLUG
Equipment Class
DTS - Digital Transmission SystemSmart Plug
Equipment Class
DTS - Digital Transmission SystemA19 LED bulb
Equipment Class
DTS - Digital Transmission SystemCeiling fan
Equipment Class
DTS - Digital Transmission System