Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
OTHER WARNINGS Risk of Fire Risk of Electrical Shock Risk of Burns MEDICAL EQUIPMENT CAUTION - PLEASE READ! This device is intended for installation in accordance with the National Electric Code and local regulations in the United States, or the Canadi- an Electrical Code and local regulations in Canada. If you are unsure or uncomfortable about performing this installation consult a qualified electrician. CONTROLLING APPLIANCES Please exercise EXTREME CAUTION when using Z-Wave devices to control appliances. Reason being is because the appliance you want to control may be in a separate room and if unintentional behavior occurs (such as a device turning on or off - either intentionally via schedules, or unintentionally via network error) this event may lead to a hazardous condition. For these reasons, please note the following suggestions: 1) Do not include Z-Wave devices in Groups or Scenes if they control appliances. 2) Do not use Z-Wave devices to control electric heaters or any other appliances which may present a hazardous condition due to unattend- ed, unintentional, or automatic power control. WARNING - SHOCK HAZARD TURN OFF THE POWER to the circuit for the switch and lighting fixture at the service panel (circuit breaker) prior to installation. ALL WIRING CONNECTIONS MUST BE MADE WITH THE POWER OFF to avoid personal injury and/or damage to the switch. Please DO NOT use this switch to control Medical or Life Support equipment. Z-Wave devices should never be used to control the On/Off status of Medical and/or Life Support equipment. Model: ZW315 Power: 125VAC, 60Hz Frequency: 908.42 MHz Maximum Load:150W LED, 500W incandescent (300W with both sides of heat sink tabs off) Minimum Load: 5W for LED bulbs Range: Up to 100 feet line of sight Operating Temperature Range: 32-104° F (0-40° C) For indoor use. Specifications subject to change without notice due to continuing product improvement Approval: Z-Wave Plus Certified switch x1 V1.0 2020.12 Z-WAVE INTEROPERABILITY This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applica- tions. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network. This Device supports Lifeline (association group 1) supporting 1 node for lifeline communication. Group 1 must be assigned the Node ID of the primary controller where unsolicited notifications will be sent. The Z-Wave controller should set this association automatically aer inclusion. Lifeline association only supports the “Device Reset Locally” function. Refer to the instructions of your controller for any available details on how this can be set. wiring x1 Part 1. Introduction Contents A quick note before we give out the wiring schematics. Please do not try installing this device if you are unsure of how electrical circuits operate within your home. As exciting as it is to have a smart switch installed, it can be dangerous and even life-threatening if you do not install this correctly. Please consult a qualified electrician if necessary. With that said, here are a few other warnings we’d like to point out for your safety: A Few Quick Reminders Note before installation 1) The Z-Wave In-wall Smart Switch must not exceed 150W LED, 500W incandescent. 2) Work with regular 3-way on/off for 2 locations control. It can only be connected with regular 3-way on/off switch, don't use a smart switch or a dimmer switch! Couldn't work with an add-on switch! 3) The colors of your wires may not match the ones in our diagrams so please make sure you've identified all wires correctly based on their source, not color only. 4) Please check your original 3-way wiring circuit in your home before installation, and then follow the wiring diagram option 1 or 2 in the manual. 5) Install the smart switch in the switch box which directly connects to the power Line and Neutral. 6) This switch requires a Neutral for installation, or the installation will not succeed. 7) Not recommended for fan. • Locally button function • LED Indicator • Auto Turn-Off Timer • Auto Turn-On Timer • Restores state aer power failure • Dimmer speed (ON/OFF Control) • Dimmer speed (only for local press & hold) • Multilevel minimum value can be set • Multilevel maximum value can be set • Association Group • Locally Button Press function • Command classes Function description • LED indicator/ Button function • Adding / reset the device ( Factory setting) • Min & Max Brightness Value Setting • Wiring instructions • Single pole and 3-way wiring diagram •Adding Device To Z-Wave Network •To Remove The Device • To Return The Device To Factory Defaults • Association Group • Product introduction • Installation steps Part 1. Introduction Part 2. Wiring Diagram Part 4. Manual Control Part 3. Network Configuration • Solutions to some common problems Part 6. Troubleshooting CHANGING THE COLOR OF THE PADDLE(OPTIONAL) This step is optional. Before you start you may want to change the color of the paddle to match your wallplate or decor. 1. Push side tabs in on one side and then the other to release paddle. Li the cover up and off. 2. Simply put the new paddle onto the switch by side tabs and snap securely into place.Once this step has been completed please proceed to part 2 wiring. HOW TO INSTALL THE WIRES 3. STRIP WIRE AT 3/8-1/2” 1. Unscrew: carefully turn the screw counterclockwise to leave enough space for the wire to be inserted. Do not unscrew the screws completely. 2. Press down: Once loosened, use your finger so it catches the thread. 3. Insert the wire: make sure the wire is completely straight, then insert it into the terminal while holding down the screw. Do not wrap the wire around the screw! 4. Tighten: Turn the screw clockwise to tighten the wire. Make sure the wires are locked! Note: There are 2 holes for each terminal can be used in the connection.You can use a jump wire or the second ho…
Text truncated - open the document above for the full version.
NIE-TECHCO.,LTD CoveredEquipmentCertificationAttestationLetter 2/2/2026 NemkoNorthAmerica,Inc. 303RiverRoad Ottawa K1V1H2 Canada ATTN.:ReviewingEngineer FCCID:2AQURZW315 NIE-TECHCO.,LTD(“theapplicant”)certifiesthattheequipmentforwhichauthorization issoughtisnot“covered”equipmentprohibitedfromreceivinganequipment authorizationpursuanttosection2.903oftheFCCrules. Note:Iftheequipmentforwhichtheapplicantseeksauthorizationisproducedby anyoftheentitiesidentifiedonthecurrentCoveredList,theapplicantshould includeanexplanationonwhytheequipmentisnot“covered”equipment. NIE-TECHCO.,LTD(“theapplicant”)certifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredListasanentityproducing “covered”equipment. NIE-TECHCO.,LTD(“theapplicant”)certifiesthattheequipmentforwhichauthorization issoughtdoesnotincludecybersecurityoranti-virussoftwareproducedorprovidedby KasperskyLab,Inc.oranyofitssuccessorsandassignees,includingequipmentwith integratedKasperskyLab,Inc.(oranyofitssuccessorsandassignees)cybersecurityor anti-virussoftwarepursuanttoDA-24-886andKDB986446D01CoveredEquipment GuidancesectionB(2a). Signed: Printedname:JianghaiNie Title:Manager CompanyName:NIE-TECHCO.,LTD Date:2/2/2026
NIE-TECHCO.,LTD 2/2/2026 NemkoNorthAmerica,Inc. 303RiverRoad Ottawa,Ontario,Canada K1V1H2 REQUESTFORCONFIDENTIALITY-FCC FCCID:2AQURZW315 PursuanttoSections0.457(d)(1)(ii)and0.459oftheCommission’sRulesandFCCGuidance document726920,weherebyrequestconfidentialtreatmentofinformationaccompanyingthis applicationasoutlinedbelow: PERMANENTLONG-TERMCONFIDENTIALITY: Schematics BlockDiagrams TheoryofOperation Theaboveinformationcontainstradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthisinformationmightbeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors.TheApplicantunderstandsthatpursuanttoRule 0.457(d)(1)(ii),disclosureofthisApplicationandallaccompanyingmaterialswillnotbemadebefore thedateoftheGrantforthisApplication. Sincerely, Signed: Printedname:JianghaiNie Title:Manager
FCCID:2AQURZW315 FCCID:2AQURZW315 FCCID:2AQURZW315
Ground Terre ZW315 Model: ZW315FCC ID: 2AQURZW315Indoor use onlyZ-Wave In-Wall Dimmer Switch 17 mm 15 mm 12x15mm Dimmer ZW315 125VAC/120VCA 60Hz 600W 2-gang 500W 2 compartiments 500W 3-gang 400W 3 compartiments 400W 300W dimmable CFL/LED 300W gradateur CFL/DEL Operating temperature Température de service 32-104°F(0-40°C) Gradateur Pour utilisation intérieure uniquement. Sert à commander des appareils àDEL,CFL,incandescence installés de facon permanente seulement. For indoor use only. For control of permanently installed LED, CFL and incandescent fixtures only. 5030071 MODEL(): ZW315 镭雕(越南生产) BRAND():
FCCID:2AQURZW315 FCCID:2AQURZW315 FCCID:2AQURZW315 FCCID:2AQURZW315 ANT
ReportNo.:PTC25122304203E-FC03 Page1of8 FCCTESTREPORT FCCID:2AQURZW315 Product:Z-WaveInWallDimmerSwitch ModelName:ZW315 Brand:N/A ReportNo.:PTC25122304203E-FC03 Preparedfor NIE-TECHCo.,Ltd Jiliancommercialcenter9001,JinxiuroadNo.2,ChanganTown,DongguanCity,GuangDongProv., CHINA Preparedby PreciseTesting&CertificationCo.,Ltd. Building1,No.6,TongxinRoad,DongchengStreet,Dongguan,Guangdong,China ReportNo.:PTC25122304203E-FC03 Page2of8 TESTRESULTCERTIFICATION Applicant’sname:NIE-TECHCo.,Ltd Address: Jiliancommercialcenter9001,JinxiuroadNo.2,Changan Town,DongguanCity,GuangDongProv.,CHINA Manufacture'sname:UltraTechIndustriesCompanyLimited Address: NONSAOINDUSTRIALCLUSTER,TANDINHCOMMUNE,Bac NinhProvince,VIETNAM Productname:Z-WaveInWallDimmerSwitch Modelname:ZW315 Testprocedure:FCCCFR47Part1.1307(b)(1) TestDate:Jan.09,2026toJan.23,2026 DateofIssue:Jan.23,2026 TestResult:PASS ThisdevicedescribedabovehasbeentestedbyPTC,andthetestresultsshowthatthe equipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditisapplicable onlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofPTC,this documentmaybealteredorrevisedbyPTC,personalonly,andshallbenotedinthe revisionofthedocument. TestEngineer: Jackzhou/Engineer TechnicalManager: SimonPu/Manager ReportNo.:PTC25122304203E-FC03 Page3of8 Contents Page 2TESTSUMMARY...............................................................................................................................................4 3GENERALINFORMATION..............................................................................................................................5 3.1GENERALDESCRIPTIONOFE.U.T..........................................................................................................5 4RFEXPOSURE..................................................................................................................................................6 4.1REQUIREMENTS........................................................................................................................................6 4.2THEPROCEDURES/LIMIT........................................................................................................................6 4.3MPECALCULATIONMETHOD..................................................................................................................7 4.4MANUFACTURINGTOLERANCE.................................................................................................................7 4.5TESTRESULT...........................................................................................................................................8 ReportNo.:PTC25122304203E-FC03 Page4of8 2TestSummary TestItemsTestRequirementResult MaximumPermissibleExposure (ExposureofHumanstoRFFields) 15.247(i)PASS Remark: N/A:NotApplicable ReportNo.:PTC25122304203E-FC03 Page5of8 3GeneralInformation 3.1GeneralDescriptionofE.U.T. ProductName : Z-WaveInWallDimmerSwitch ModelName : ZW315 OperationFrequency : 908.40MHz 908.42MHz 916.00MHz 912MHz 920MHz TypeofModulation : 2FSKfor908.40MHz 2FSKfor908.42MHz 2GFSKfor916.00MHz DSSSOQPSKLRfor912MHzand920MHz Antennainstallation : PCBAntenna AntennaGain : -11.59dBi Powersupply: Input:125V60Hz Output:125V60Hz600W HardwareVersion : N/A SoftwareVersion : N/A ReportNo.:PTC25122304203E-FC03 Page6of8 4RFExposure TestRequirement :FCCPart1.1307(b)(1) EvaluationMethod :KDB447498D01GeneralRFExposureGuidancev06 4.1Requirements Systemsoperatingundertheprovisionsofthissectionshallbeoperatedinamannerthatensuresthat thepublicisnotexposedtoradiofrequencyenergylevelsinexcesslimitformaximumpermissible exposure.Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeen definedasamobiledevicewherebyadistanceof0.2mnormallycanbemaintainedbetweentheuser andthedevice. 4.2Theprocedures/limit (A)LimitsforOccupational/ControlledExposure FrequencyRangeElectricFieldMagneticFieldPowerDensity(S)AveragingTime 0.3-3.06141.63(100)*6 3.0-301842/f4.89/f(900/f)*6 30-30061.40.1631.06 300-1500F/3006 1500-100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure FrequencyRangeElectricFieldMagneticFieldPowerDensity(S)AveragingTime 0.3-1.346141.63(100)*30 1.34-30824/f2.19/f(180/f)*30 30-30027.50.0730.230 300-1500F/150030 1500-100,0001.030 Note:f=frequencyinMHz;*Plane-waveequivalentpowerdensity ReportNo.:PTC25122304203E-FC03 Page7of8 4.3MPECalculationMethod E(V/m)= d GP30 PowerDensity:Pd(W/m²)= 377 2 E E = Electricfield(V/m) P=PeakRFoutputpower(W) G=EUTAntennanumericgain(numeric) d=Separationdistancebetweenradiatorandhumanbody(m) Theformulacanbechangedto Pd = 2 377 30 d GP θφ FromthepeakEUTRFoutputpower,theminimummobileseparationdistance,d=0.2m,aswellas thegainoftheusedantenna,theRFpowerdensitycanbeobtained 4.4Manufacturingtolerance Freq. (MHz) Fieldstrength(max)(dBuV/m) EIRP(max) (dBm) 908.4089.98-5.22 908.4290.12-5.08 916.0089.68-5.52 Note:EIRP=E-104.8+20logD, Where EistheelectricfieldstrengthindBμV/m EIRPistheequivalentisotropicallyradiatedpowerindBm disthespecifiedmeasurementdistanceinm whereD=3,EIRP=E-95.2. ReportNo.:PTC25122304203E-FC03 Page8of8 4.5TestResult Mode Antenna Gain (numeric) Max.PeakOutput Power(dBm) Tuneup tolerance (dBm) MaxTuneUp Power(mW) PowerDensity (mW/cm2) LimitofPower Density (mW/cm2) Result 912MHz0.07-0.854-0.854±11.0341890.0001440.608000Pass 920MHz0.07-1.69-1.69±10.85310.0001190.613333Pass 908.40MHz0.07-5-5±10.3981070.0000550.605600Pass 908.42MHz0.07-5-5±10.3981070.0000550.605613Pass 916.00MHz0.07-5.5-5.5±10.3548130.0000490.610667Pass SimultaneousSAREvaluation: Thedevicecan'tsupportsimultaneoustransmitter. ******THEENDREPORT******
Page1of47 FCCTESTREPORT FCCID:2AQURZW315 Product: Z-WaveInWallDimmerSwitch ModelName: ZW315 Brand: N/A ReportNo.: PTC25122304203E-FC02 Preparedfor NIE-TECHCo.,Ltd Jiliancommercialcenter9001,JinxiuroadNo.2,ChanganTown,DongguanCity, GuangDongProv.,CHINA Preparedby PreciseTesting&CertificationCo.,Ltd Building1,No.6,TongxinRoad,DongchengStreet,Dongguan,Guangdong,China ReportNo.:PTC25122304203E-FC02 Page2of47 1TESTRESULTCERTIFICATION Applicant’sname: NIE-TECHCo.,Ltd Address: Jiliancommercialcenter9001,JinxiuroadNo.2,Changan Town,DongguanCity,GuangDongProv.,CHINA Manufacture'sname: UltraTechIndustriesCompanyLimited Address: NONSAOINDUSTRIALCLUSTER,TANDINHCOMMUNE,BacNinh Province , VIETNAM Productname: Z-WaveInWallDimmerSwitch Modelname: ZW315 Standards:FCCCFR47Part15Section15.247 Testprocedure:ANSIC63.10-2020 TestDate: Dec.26,2026toJan.23,2026 DateofIssue: Jan.23,2026 TestResult:Pass ThisdevicedescribedabovehasbeentestedbyPTC,andthetestresultsshowthatthe equipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlyto thetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofPTC,thisdocument maybealteredorrevisedbyPTC,personalonly,andshallbenotedintherevisionofthedocument. TestEngineer: Jackzhou/Engineer TechnicalManager: SimonPu/Manager ReportNo.:PTC25122304203E-FC02 Page3of47 Contents Page 1TESTRESULTCERTIFICATION...............................................................................................................................2 2TESTSUMMARY..........................................................................................................................................................5 2.1TESTSITE............................................................................................................................................................6 3GENERALINFORMATION.......................................................................................................................................7 3.1GENERALDESCRIPTIONOFE.U.T.....................................................................................................................7 3.2CHANNELLIST.....................................................................................................................................................8 4EQUIPMENTDURINGTEST....................................................................................................................................9 4.1EQUIPMENTSLIST.............................................................................................................................................9 4.2MEASUREMENTUNCERTAINTY.........................................................................................................................11 4.3DESCRIPTIONOFSUPPORTUNITS...................................................................................................................12 5CONDUCTEDEMISSION..........................................................................................................................................13 5.1E.U.T.OPERATION............................................................................................................................................13 5.2EUTSETUP.......................................................................................................................................................13 5.3TESTSET-UP(BLOCKDIAGRAMOFCONFIGURATION).................................................................................14 5.4MEASUREMENTPROCEDURE............................................................................................................................14 5.5CONDUCTEDEMISSIONLIMIT...........................................................................................................................14 5.6MEASUREMENTDESCRIPTION..........................................................................................................................14 5.7CONDUCTEDEMISSIONTESTRESULT.............................................................................................................14 6RADIATEDSPURIOUSEMISSIONS......................................................................................................................17 6.1EUTOPERATION...............................................................................................................................................17 6.2TESTSETUP......................................................................................................................................................18 6.3SPECTRUMANALYZERSETUP..........................................................................................................................19 6.4TESTPROCEDURE.............................................................................................................................................20 6.5SUMMARYOFTESTRESULTS...........................................................................................................................21 7CONDUCTBANDEDGEANDSPURIOUSEMISSIONSMEASUREMENT....................................................27 7.1TESTPROCEDURE.............................................................................................................................................27 7.2TESTSETUP......................................................................................................................................................27 7.3TESTRESULT....................................................................................................................................................28 ReportNo.:PTC25122304203E-FC02 Page4of47 86DBBANDWIDTHMEASUREMENT......................................................................................................................32 TESTPROCEDURE....................................................................................................................................…
Text truncated - open the document above for the full version.
ReportNo.:RFI-LAB-RF-202307-GG25 QP030-E41 Page1of9 TestingReport CustomerName:NIE-TECHCo.,Ltd ProductName:ZWN4015ANT SampleModel:ZWN4015ANT ReferenceStandard:GB/T9410-2008;ANSI/IEEEStd149-1979 IssueDate:2023.7.27 Engineer:Date: Auditor:Date: Approver:Date: ReportNo.:RFI-LAB-RF-202307-GG25 QP030-E41 Page2of9 Version VersionNo.DateDescriptionFormulateApproval A02023.7.27Forthefirsttime,formulateZkrisEason Contents 1.GeneralInformation.........................................................................................................................3 1.1Generalinformationoftestinginstitutions...........................................................................3 1.2Testingprinciple...................................................................................................................3 1.3Testequipment......................................................................................................................4 1.4Testenvironment...................................................................................................................4 1.5Statement..............................................................................................................................4 2.SampleInformation.........................................................................................................................5 2.1Clientinformation.................................................................................................................5 2.2DescriptionofEUT(S)..........................................................................................................5 2.3EUTappearance....................................................................................................................6 2.4EUTsetupphotooffreespaceOTAtesing..........................................................................6 3.TestResults......................................................................................................................................7 3.1Teststandard.........................................................................................................................7 3.2Testuncertainty.....................................................................................................................7 3.3Testdata................................................................................................................................7 3.3.1Typicalfreespaceefficiencyandgain......................................................................7 3.3.2Typicalfreespaceradiationpattern...........................................................................8 (Thefollowingisblank)................................................................................................................9 ReportNo.:RFI-LAB-RF-202307-GG25 QP030-E41 Page3of9 1.GeneralInformation 1.1Generalinformationoftestinginstitutions Name ShenzhenRFI-LABCommunicationTechnologyCo.,Ltd. Address 10/FA,LingyunBld,LiufangRd,BaoanDistrict,SZ Tel 13682621346 E-mail [email protected] Equipment AlltheequipmentusedinthereportisfixedinZoneB,WestSideof1/F,Building1, TingweiIndustrialPark,No.6LiufangRoad,Bao'anDistrict,Shenzhen 1.2Testingprinciple ReportNo.:RFI-LAB-RF-202307-GG25 QP030-E41 Page4of9 1.3Testequipment EquipmentModelNo.SerialNo.Manufacturer Calibration date Next calibration date OTATest System RayZone-5000 RFI-LAB-RF -D00 GTS2023.3.142025.3.13 Network Analyzer E5071C RFI-LAB-RF -D01 KEYSIGHT2023.5.112024.5.10 Network Analyzer E5071C RFI-LAB-RF -C02 KEYSIGHT2023.5.112024.5.10 1.4Testenvironment Temperature 23.6°C Humidity 58%RH Pressure 100.14kPa 1.5Statement (1)Thetestresultsinthereportareonlyapplicabletothetestedsamplesandthetestedsamples workundertheenvironmentdescribedinthereport. (2)OnlyShenzhenRFI-LABCommunicationTechnologyCo.,Ltd.havetherighttomodifythe report,andthemodificationinformationshallbeannotatedintherevisionform. (3)Anyobjectiontothisreportshallberaisedwithin30daysafterformalconfirmationofthe report. (4)Thisreportisinvalidifthereisanyevidencethatthesampleinformationprovidedisfalsified. (5)Thereportisinvalidwithoutthesignatureoftheauditorandapprover. ReportNo.:RFI-LAB-RF-202307-GG25 QP030-E41 Page5of9 2.SampleInformation 2.1Clientinformation Name NIE-TECHCo.,Ltd Address / Contacts / Tel / E-mail / Manufacturer / 2.2DescriptionofEUT(S) ProductName ZWN4015ANT SampleModel ZWN4015ANT AntennaSize / SerialNo. / AntennaType PCBAntenna TestItem Antennagain;Efficiency;Radiationpattern FrequencyRange 902MHz-928MHz ReceivedDate 2023.7.26 TestDate 2023.7.26 Remark ThelengthoftheRFcableis90mm ReportNo.:RFI-LAB-RF-202307-GG25 QP030-E41 Page6of9 2.3EUTappearance 2.4EUTsetupphotooffreespaceOTAtesing Planform Frontview ReportNo.:RFI-LAB-RF-202307-GG25 QP030-E41 Page7of9 3.TestResults 3.1Teststandard NameParameterMethodStandardno. Mobile communication antenna Antennagain Genericspecification forantennasusedinthe mobilecommunications GB/T 9410-2008 Radiationpattern Antenna Radiationefficiency IEEEStandardTest ProceduresforAntennas ANSI/IEEEStd 149-1979 Gainanddirectivity 3.2Testuncertainty TheuncertaintywascalculatedonthebasisoftheGUMpublishedbyISO,usingthe inclusionfactorofK=2andthe95%confidenceleveltoexpresstheextended uncertainty. ItemUncertainty Antennagain±0.72dB Radiationefficiency±0.72dB 3.3Testdata 3.3.1Typicalfreespaceefficiencyandgain Frequency/MHz 902904906908910912914916918920922924926928 PeakGain/dBi -12.48-12.33-12.28-12.19-12.10-12.13-12.13-12.08-11.93-11.82-11.66-11.63-11.59-11.63 Efficiency/% 1.911.952.002.062.112.132.152.192.272.362.452.512.572.64 ReportNo.:RFI-LAB-RF-202307-GG25 QP030-E41 Page8of9 3.3.2Typicalfreespaceradiationpattern (1)X-ZPlane(unit:dBi): (2)Y-ZPlane(unit:dBi): ReportNo.:RFI-LAB-RF-202307-GG25 QP030-E41 Page9of9 (3)X-YPlane(unit:dBi): (4)TypicalFreeSpace3DRadiationPatternat926MHz(unit:dBi): -------------------------------------------------End------------------------------------------------ (Thefollowingisblank)
FCCID:2AQURZW315 ConductedEmissions RadiatedSpuriousEmissions From30MHz-1000MHz FCCID:2AQURZW315 TestfrequencyfromAbove1GHz
230 Rt 206 STE 401 Flanders · Flanders, New Jersey, 7836 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 912 MHz - 912 MHz | 820.00 µW |
| 2 | 15C | 920 MHz - 920 MHz | 680.00 µW |