FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. CALTTA TECHNOLOGIES CO., LTD./
  3. 2AQV7PR900V

2AQV7PR900VDigital Repeater, VHF DMR (Digital Mobile Radio)

CALTTA TECHNOLOGIES CO., LTD.
Digital Repeater, VHF DMR (Digital Mobile Radio) - FCC ID 2AQV7PR900V - CALTTA TECHNOLOGIES CO., LTD.
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
May 25, 2021
Application Purpose
Original Equipment
Date of Application
May 25, 2021
Equipment Note
Digital Repeater, VHF DMR (Digital Mobile Radio)
Frequency Range
136.00000000 - 174.00000000
Company
CALTTA TECHNOLOGIES CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

secret▲ Allrightsreserved.NospreadingabroadwithoutpermissionofCaltta. 1 QUICKREFERENCEGUIDE PR900DIGITALREPEATER secret▲ Allrightsreserved.NospreadingabroadwithoutpermissionofCaltta. 2 PR900 EditionDateAuthorReviewerRemarks V1.02019/3/20 secret▲ Allrightsreserved.NospreadingabroadwithoutpermissionofCaltta. 3 LegalInformation ©2019CalttaTechnologies.Allrightsreserved. 2019CopyrightCalttaTechnologiesCo.,Ltd.Allrightsreserved Copyrightstatement: ThecopyrightofthisdocumentbelongstoCalttaTechnologiesCo.,Ltd.Textcontains proprietaryinformationownedbyCalttaTechnologiesCo.,Ltd.,withoutthewritten permissionofCalttaTechnologiesCo.,Ltd.,anyunitorindividualshallnotuseorleakany documentandpictures,thisdocumentcontainstables,picture,dataandother information. TheinformationinthisdocumentcontainsthedevelopmentprogressofCaltta TechnologiesCo.,Ltd.productsandtechnologywillcontinuetoupdate,Caltta TechnologiesCo.,Ltd.wouldnotnoticesuchinformationupdates. Userinstructions Anyuseofradiotransmitterswithingovernmentcontrolledareaswithoutthe authority'spermissionisforbiddenbythelaw. Penaltieswillbegivenonthosewhousetransmittersillegally. Maintenancecanonlybecarriedoutbyprofessionals. Disclaimer Duringthepreparationprocessofthismanual,wesoughtforaccuracyandcompleteness ofitscontents.Shouldtherebeanyerrorsoromissions,wewillnotbearanyresponsibility. Duetocontinuousdevelopmentoftechnology,wereservestherightnottogivefurther noticeonchangesofdesignandspecificationsofourproducts. RFradiationinformation ThisproductonlymeetstheapplicationrequirementsonRFenergyradiation.Theuser mustbeacutelyawareofthehazardsbroughtbyRFradiation,andabletotake correspondingmeasurestomeettheprescribedrequirementsofRFradiation. secret▲ Allrightsreserved.NospreadingabroadwithoutpermissionofCaltta. 4 Catalog 1UnpackingandChecking............................................................................................................6 2RadioOverview............................................................................................................................6 2.1LEDIndicators...................................................................................................................7 2.2MMPConnector.................................................................................................................7 2.3MAPConnector..................................................................................................................8 2.4ACCableConnector..........................................................................................................9 2.5DCConnector.....................................................................................................................9 2.6PowerON/OFFButton.......................................................................................................9 2.7OperationButton................................................................................................................9 3Operations..................................................................................................................................10 3.1PoweringOn/Off..............................................................................................................10 3.1.1ACPowerSupply.......................................................................................10 3.1.2DCPowerSupply.......................................................................................10 3.2VoiceandDataTransfer..................................................................................................11 3.3IPConnecting...................................................................................................................11 3.4Warning............................................................................................................................11 4CPS-Menu..................................................................................................................................11 4.1File11 4.2Model................................................................................................................................12 4.3Program............................................................................................................................13 4.4Tools.................................................................................................................................15 4.5View..................................................................................................................................16 5CommonSetting........................................................................................................................16 5.1CommonSetting-GeneralSetting....................................................................................16 5.1.1CommonSetting-GeneralSetting-CommonSetting........................................16 secret▲ Allrightsreserved.NospreadingabroadwithoutpermissionofCaltta. 5 5.1.2CommonSetting-GeneralSetting-DigitalSetting............................................20 5.1.3CommonSetting-GeneralSetting-AnalogSetting............................................22 5.2CommonSetting-UISetting.............................................................................................23 5.2.1CommonSetting-UISetting..............................................................................23 5.2.2CommonSetting-UISetting-Backlight.............................................................25 5.2.3CommonSetting-UISetting-Button.................................................................25 5.2.4CommonSetting-UISetting-Menu...................................................................27 6ConventionalSetting.................................................................................................................28 6.1.1ConventionalSetting-Password........................................................................28 6.1.2ConventionalSetting-Zone.......................…

Text truncated - open the document above for the full version.

Cover Letter(s)

CALTTA TECHNOLOGIES CO., LTD. ADD: Floor12, Building G2, international E-City Nanshan District, Shenzhen, China Tel: 0755- 26773333; Fax: 0755-26774670 Email: [email protected] FCC Confidential Authorization Date: 2021-05-08 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AQV7PR900V In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, CALTTA TECHNOLOGIES CO., LTD. hereby requests long-term confidential treatment of information accompanying this application as outlined below: • Block Diagram • Schematics • Operation Description • Parts List/Tune up procedure (for licensed devices) The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Chris Lau Certification Engineer

Cover Letter(s)

CALTTA TECHNOLOGIES CO., LTD. ADD: Floor12, Building G2, international E-City Nanshan District, Shenzhen, China Tel: 0755- 26773333; Fax: 0755-26774670 Email: [email protected] Date: 2021-05-08 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Extended Frequencies Justification Dear Sir/Madam, The Radio with FCC ID: 2AQV7PR900V was designed to operate in the frequency bands 136-174MHz To aid equipment authorization in other countries which accept the United States FCC Grant for Certification, CALTTA TECHNOLOGIES CO., LTD. is requesting that the FCC lists the frequencies 136-174MHz, under FCC Rule Part 90 on the FCC Grant. CALTTA TECHNOLOGIES CO., LTD. attests that the radio will not be marketed to USA users with the frequency band which is not allowed by the rule part 90. Per the FCC’s KDB634817 guidance, as an alternative to listing the exact frequencies, we acknowledge that it’s a violation of the FCC Rules if this device operates on unauthorized frequencies. Frequency Range (MHz) FCC Rule Part 136-150.8 For FEDERAL 150.8-152.855 FCC Part 90 152.855-154 FCC Part 90 154-156.2475 FCC Part 90 157.1875-157.45 FCC Part 90 157.45-161.575 FCC Part 90 161.775-161.9625 FCC Part 90 162.0375-173.2 FCC Part 90 173.2-173.4 FCC Part 90 173.4-174 For FEDERAL Also, equipment programming is the responsibility of Authorized Service Personnel, the radio complies with 47 CFR Part 90.203(e), in that the operator cannot directly program the transmit frequencies using the normally accessible external controls. Sincerely, Signature Chris Lau Certification Engineer

Cover Letter(s)

CALTTA TECHNOLOGIES CO., LTD. ADD: Floor12, Building G2, international E-City Nanshan District, Shenzhen, China Tel: 0755- 26773333; Fax: 0755-26774670 Email: [email protected] Date: 2021-05-08 To: FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Attestation statement regarding the Digital Portable Radio spectrum efficiency TYPE OF EQUIPMENT: Digital Repeater, VHF DMR(Digital Mobile Radio) Model number: PR900 VHF FCC ID: 2AQV7PR900V Dear Sir or Madam We, CALTTA TECHNOLOGIES CO., LTD. declare that the time division multiple access (TDMA) technology provides two paths in a 12.5 kHz channel bandwidth, thus meeting the one voice path per 6.25 kHz of spectrum requirement. This radio also provides data rate of 9600 bps in a 12.5 kHz channel, thus meeting the minimum data rate of 4800 bps in a 6.25 kHz channel. Please contact the undersigned if you have any questions or need any further information. Sincerely, Signature Chris Lau Certification Engineer

External Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 1 of 4 EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 2 of 4 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 3 of 4 TX antenna port RX antenna port GPS antenna port Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 4 of 4

ID Label/Location Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label 1 FCC ID Label Location Information Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF FCC ID Label 2 FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)

Internal Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 1 of 16 EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 2 of 16 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 3 of 16 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 4 of 16 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 5 of 16 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 6 of 16 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 7 of 16 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 8 of 16 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 9 of 16 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 10 of 16 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 11 of 16 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 12 of 16 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 13 of 16 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 14 of 16 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 15 of 16 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: SZ1210412-10911E-RF Page 16 of 16

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ1210412-10911E-00 FCC Part 90 Page 10 of 53 §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) Applicable Standard According to subpart 2.1091 systems operating under the provisions of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in excess of the communication guidelines. Limits for Occupational/Controlled Exposure Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (Minutes) 0.3-1.34 614 1.63 *(100) 6 1.34-30 1824/f 4.89/f *(900/f 2 ) 6 30-300 61.4 0.163 1.0 6 300-1500 / / f/300 6 1500-100,000 / / 5.0 6 f = frequency in MHz * = Plane-wave equivalent power density Result Calculated Formulary: Predication of MPE limit at a given distance S = 2 4R PG  S = power density (in appropriate units, e.g. mW/cm 2 ) P = power input to the antenna (in appropriate units, e.g., mW). G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain. R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) Frequency (MHz) Antenna Gain Max Tune Up Output Power MPE Limit (mW/cm 2 ) Minimum Distance (cm) (dBi) (numeric) (W) 136-174 8.5 7.08 28.1 1.0 126 Note: The maximum tune-up output power is 47.5dBm (56.2W), 50% duty cycle was used, so maximum tune-up output power is 28.1W To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 126cm from nearby persons. Result: compliance.

Test Report

Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government. This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”. BACL is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 90 TEST REPORT For CALTTA TECHNOLOGIES CO., LTD. Floor12, Building G2, international E-City Nanshan District, Shenzhen, China FCC ID: 2AQV7PR900V Report Type: Original Report Product Type: Digital Repeater, VHF DMR(Digital Mobile Radio) Re port Number: SZ1210412-10911E-00 Re port Date: 2021-05-10 Reviewed B y: Jacob Kong RF Engineer Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West), 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: SZ1210412-10911E-00 FCC Part 90 Page 2 of 53 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 TEST METHODOLOGY .................................................................................................................................................. 4 MEASUREMENT UNCERTAINTY .................................................................................................................................... 5 TEST FACILITY ............................................................................................................................................................. 5 SYSTEM TEST CONFIGURATION .......................................................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 6 EUT EXERCISE SOFTWARE .......................................................................................................................................... 6 SPECIAL ACCESSORIES ................................................................................................................................................. 6 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 6 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 6 EXTERNAL I/O CABLE .................................................................................................................................................. 6 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 7 SUMMARY OF TEST RESULTS ............................................................................................................................... 8 TEST EQUIPMENT LIST ........................................................................................................................................... 9 §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) ....................................................................................... 10 APPLICABLE STANDARD ............................................................................................................................................ 10 RESULT ...................................................................................................................................................................... 10 FCC §2.1046 & §90.205 - RF Output Power ............................................................................................................. 11 APPLICABLE STANDARD ............................................................................................................................................ 11 TEST PROCEDURE ...................................................................................................................................................... 11 TEST DATA ................................................................................................................................................................ 11 FCC §2.1047 & §90.207 - MODULATION CHARACTERISTIC .......................................................................... 19 APPLICABLE STANDARD ............................................................................................................................................ 19 TEST PROCEDURE ...................................................................................................................................................... 19 TEST DATA ................................................................................................................................................................ 19 FCC §2.1049 & §90.209 & §90.210 – OCCUPIED BANDWIDTH & EMISSION MASK ...…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Chris Lau
[email protected]0755-26773333Fax: 0755-26774670

Test Firm

Bay Area Compliance Laboratories Corp. (Shenzhen)Well Wang
[email protected]+86 (0) 755 33320018

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
39136 MHz - 174 MHz50 W7K60F1E2.5 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is Maximum rated conducted at antenna terminal. Minimum output setting is 1 W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 126 cm from all persons. A label, as described in this filing must be displayed on the device to direct users to the specific training information required for meeting RF exposure requirements. RF exposure compliance may be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of Section 1.1307(b)(3).

Other Applications from CALTTA TECHNOLOGIES CO., LTD.

Bluetooth PTT - FCC ID 2AQV7AH300 - CALTTA TECHNOLOGIES CO., LTD.
2AQV7AH300

Bluetooth PTT

Aug 03, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Digital Portable Radio - FCC ID 2AQV7PH6X0UHF - CALTTA TECHNOLOGIES CO., LTD.
2AQV7PH6X0UHF

Digital Portable Radio

Jul 17, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Broadband Portable Radio - FCC ID 2AQV7E360 - CALTTA TECHNOLOGIES CO., LTD.
2AQV7E360

Broadband Portable Radio

Jan 03, 2021

Equipment Class

TNF - Licensed Non-Broadcast Transmitter Held to Face