2AQVU0074Arm-type Fully Automatic Digital Blood Pressure Monitor

JOYTECH HEALTHCARE CO., LTD.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 29, 2026
Application Purpose
Original Equipment
Equipment Note
Arm-type Fully Automatic Digital Blood Pressure Monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
JOYTECH HEALTHCARE CO., LTD.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗
↗

ID Label/Location Info

↗
↗
↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

ID Label/Location Info

size:45*12mm Arm-Type Fully Automatic Digital Blood Pressure Monitor Model:DBP-62H1B ( (11)260526 (10)260526 01)06942284623091 Power: DC5.0V,1A,5W; (or Batteries 4×1.5V AAA) IP21 ! Manufactured by JOYTECH Healthcare Co., Ltd. No.365, Wuzhou Road, Hangzhou,311100 Zhejiang,P.R. China Manufacturing Date: 2026.05.26 2AQVU0074 Series number:62H1B260500001 FCC ID: Made in China LOT 2026.05.26

ID Label/Location Info

Blood Pressure Monitor Model VHC 211-2112B size:45*12mm Manufacturers for:Veridian Healthcare 1175 Lakeside Drive, Gurnee,IL 60031Customer Service:1-866-326-1313 Made in China Battery mode:4 x AAA 6V AC adapter mode:5V 1A(not included) Firmware Version:V1.0.7 2AQVU0074FCC ID: IP21 LOT 5100280426 (01)06942284623091 (21)62H1B260400001R SN

RF Exposure Info

MRT Technology (Taiwan) Co., Ltd Report No.: 2606TW0118-U2 Phone: +886-3-3288388 Report Version V1.0 Web: www.mrt-cert.com Issue Date: 2026-07-23 Page Number: 1 of 8 RF Exposure Evaluation Declaration FCC ID : 2AQVU0074 Applicant : JOYTECH Healthcare Co., Ltd. Product : Arm-type Fully Automatic Digital Blood Pressure Monitor Model No. : DBP-62H1B Serial Model No. : VHC 211-2112B FCC Rule Part(s) : FCC Part 2.1093 Received Date : 2026-06-16 Reviewed By : ( Paddy Chen ) Approved By : ( Chenz Ker) The test results relate only to the samples tested. The test results shown in the test report are traceable to the national/international standards through the calibration of the equipment and evaluated measurement uncertainty herein. The test report shall not be reproduced except in full without the written approval of MRT Technology (Taiwan) Co., Ltd. Report No.: 2606TW0118-U2 Page Number: 2 of 8 Revision History Report No. Version Description Issue Date Note 2606TW0118-U2 V1.0 Original Report 2026-07-23 Valid Report No.: 2606TW0118-U2 Page Number: 3 of 8 CONTENTS Description Page 1. General Information ............................................................................................................ 4 1.1. Applicant .................................................................................................................... 4 1.2. Manufacturer ............................................................................................................. 4 1.3. Testing Facility ........................................................................................................... 4 2. PRODUCT INFORMATION ................................................................................................... 5 2.1. Feature of Equipment under Test .............................................................................. 5 2.2. Description of Available Antennas .............................................................................. 5 2.3. Device Classification .................................................................................................. 6 2.4. Applied Standards ..................................................................................................... 6 3. RF Exposure Evaluation ..................................................................................................... 7 3.1. Limits ......................................................................................................................... 7 3.2. Test Result of RF Exposure Evaluation ...................................................................... 8 Report No.: 2606TW0118-U2 Page Number: 4 of 8 1. General Information 1.1. Applicant JOYTECH Healthcare Co., Ltd. No.365, Wuzhou Road, 311100 Hangzhou, Zhejiang Province, PEOPLE’S REPUBLIC OF CHINA. 1.2. Manufacturer JOYTECH Healthcare Co., Ltd. No.365, Wuzhou Road, 311100 Hangzhou, Zhejiang Province, PEOPLE’S REPUBLIC OF CHINA. 1.3. Testing Facility Test Site 1 - MRT Taiwan Laboratory Laboratory Location No. 38, Fuxing 2nd Rd., Guishan Dist., Taoyuan City 333, Taiwan (R.O.C.) Laboratory Accreditations TAF: 3261 FCC: 291082, TW3261 ISED: TW3261 Test Site 2 - MRT Taiwan Laboratory Laboratory Location No. 64, Wenming Rd., Guishan Dist., Taoyuan City 333, Taiwan (R.O.C.) Laboratory Accreditations TAF: 3261 FCC: 291082, TW3261 ISED: TW3261 Report No.: 2606TW0118-U2 Page Number: 5 of 8 2. PRODUCT INFORMATION 2.1. Feature of Equipment under Test 2.2. Description of Available Antennas Product Name Arm-type Fully Automatic Digital Blood Pressure Monitor Model No. DBP-62H1B Serial Model No. VHC 211-2112B Specification Bluetooth Single mode, BLE Only Accessory Adapter#1 Brand: CHANGZHOU TAIYU ELECTRICAL EQUIPMENT CO., LTD. Model No: MPSUL0501000 Input: AC 100V - 240V, 50/60Hz, 0.25A Output: DC 5V, 1000mA Note: 1.The information of the EUT (Equipment Under Test) was provided by the manufacturer. The accuracy, completeness, and validity of the information are solely the responsibility of the manufacturer. 2.Model Difference: The difference of models only for marketing different, the other hardware was the same. (declared by the manufacturer) 3.The test was performed base on DBP-62H1B. No. Manufacturer Part No. Antenna Type Peak Gain 1 HAIYUN JMD1102/JMD1105/JMD1106 PCB Antenna -1.37dBi Report No.: 2606TW0118-U2 Page Number: 6 of 8 2.3. Device Classification According to the user manual, this device is classified as a Portable Device. So, the RF exposure evaluation requirements of § 2.1093 for Portable device exposure conditions subject to MPE limits. 2.4. Applied Standards According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards: FCC Part 2.1093 & KDB 447498 D04 Interim General RF Exposure Guidance v01 Report No.: 2606TW0118-U2 Page Number: 7 of 8 3. RF Exposure Evaluation 3.1. Limits According to FCC KDB 447498 D04V01 - SAR-Based Exemption This method shall only be used at separation distances from 0.5 cm to 40 cm and at frequencies from 0.3 GHz to 6 GHz (inclusive). Pth is given by Formula . and f is in GHz, d is the separation distance (cm), and ERP 20cm is per Formula. The example values shown as below are for illustration only. Note: when 10-g extremity SAR applies, SAR test exemption may be considered by applying a factor of 2.5 to the SAR-based exemption thresholds. Report No.: 2606TW0118-U2 Page Number: 8 of 8 3.2. Test Result of RF Exposure Evaluation Product Arm-type Fully Automatic Digital Blood Pressure Monitor Test Item RF Exposure Evaluation Mode Frequency Band (MHz) Output Power (dBm) Output Power (mW) Antenna Gain (dBi) EIRP (mW) FCC Extremity SAR Test Exclusion Threshold (mW) BLE 2402~2480 1.47 1.403 -1.37 1.023 3 So, this device can comply the SAR test exclusion. The End

Test Report

MRT Technology (Taiwan) Co., Ltd. Report No.: 2606TW0118-U1 Phone: +886-3-3288388 Report Version: V1.0 Web: www.mrt-cert.com Issue Date: 2026-07-23 Template Version: 2.2 1 of 56 RF MEASUREMENT REPORT FCC ID: 2AQVU0074 Applicant: JOYTECH Healthcare Co., Ltd. Product: Arm-type Fully Automatic Digital Blood Pressure Monitor Model No.: DBP-62H1B Serial Model No.: VHC 211-2112B FCC Classification: Digital Transmission System (DTS) FCC Rule Part(s): Part 15 Subpart C (Section 15.247) Result: Complies Received Date: 2026-06-16 Test Date: 2026-06-23~2026-07-06 Reviewed By: Paddy Chen Approved By: Chenz Ker The test results relate only to the samples tested. This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report. Testing was performed in accordance with the applicable measurement procedures. The test results reported herein apply only to the specific item(s) tested. The test report shall not be reproduced except in full without the written approval of MRT Technology (Taiwan) Co., Ltd. Report No.: 2606TW0118-U1 2 of 56 Revision History Report No. Version Description Issue Date Note 2606TW0118-U1 V1.0 Original Report 2026-07-23 Valid Report No.: 2606TW0118-U1 3 of 56 CONTENTS Description Page 1. General Information ................................................................................................................................ 5 1.1. Applicant ...................................................................................................................................... 5 1.2. Manufacturer ................................................................................................................................ 5 1.3. Testing Facility ............................................................................................................................. 5 1.4. Product Information ...................................................................................................................... 6 1.5. Radio Specification under Test .................................................................................................... 7 1.6. Working Frequencies ................................................................................................................... 8 2. Test Configuration ................................................................................................................................... 9 2.1. Test Mode ..................................................................................................................................... 9 2.2. Test System Connection Diagram.............................................................................................. 10 2.3. Test Software ............................................................................................................................. 10 2.4. Applied Standards ....................................................................................................................... 11 2.5. Test Environment Condition ........................................................................................................ 11 3. Antenna Requirements ......................................................................................................................... 12 4. Measuring Instrument ........................................................................................................................... 13 5. Decision Rules and Measurement Uncertainty .................................................................................. 14 5.1. Decision Rules ........................................................................................................................... 14 5.2. Measurement Uncertainty .......................................................................................................... 14 6. Test Result .............................................................................................................................................. 15 6.1. Summary .................................................................................................................................... 15 6.2. 6 dB Bandwidth Measurement ................................................................................................... 16 6.2.1. Test Limit .................................................................................................................................... 16 6.2.2. Test Procedure ........................................................................................................................... 16 6.2.3. Test Setting ................................................................................................................................ 16 6.2.4. Test Setup .................................................................................................................................. 16 6.2.5. Test Result ................................................................................................................................. 16 6.3. Output Power Measurement ...................................................................................................... 17 6.3.1. Test Limit .................................................................................................................................... 17 6.3.2. Test Procedure ........................................................................................................................... 17 6.3.3. Test Setting ................................................................................................................................ 17 6.3.4. Test Setup .................................................................................................................................. 17 6.3.5. Test Result ..............................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Report No.: RF8230406039-L1-R Page 1 of 10 Antenna Test Report Product Name: Bluetooth Module Report No. : RF8230406039-L1-R Product Model: JMD1102/JMD1105/JMD1106 Security Classification: Open Version:V1.0 Total Page: 10 HAIYUN Laboratory Report Prepared By: Checked By: Approved By: Krain Wu Vic Cai Flank Wang Report No.: RF8230406039-L1-R Page 2 of 10 Antenna Test Report Equipment: Bluetooth Module Model: JMD1102/JMD1105/JMD1106 Applicant: JOYTECH Healthcare Co., Ltd. Applicant address: No.365,Wuzhou Road311100 Hangzhou, Zhejiang ProvincePEOPLE'S REPUBLIC OF CHINA Manufacture: JOYTECH Healthcare Co., Ltd. Address: No.365,Wuzhou Road311100 Hangzhou, Zhejiang ProvincePEOPLE'S REPUBLIC OF CHINA Date of Receipt: Apr 7.2023 Date of Test: Apr 1.2023~May 10.2023 Issue Date: May 10.2023 Tested by: Shenzhen HAIYUN Testing Co., Ltd. Laboratory TEL: 0755-89990666-21508 FAX:0755-26801723 Note: This report shall not be reproduced except in full, without the written approval of Shenzhen HAIYUN Testing Co., Ltd. Laboratory. This document may be altered or revised by Shenzhen HAIYUN Testing Co., Ltd. Laboratory. personnel only, and shall be noted in the revision section of the document. The test results of this report relate only to the tested sample identified in this report. Report No.: RF8230406039-L1-R Page 3 of 10 TABLE OF CONTENTS 1.Purose & Environment .................................................................................................................................. 4 1.1 Purpose ................................................................................................................................................. 4 1.2 Environment ......................................................................................................................................... 4 2.Test photos、Test Condition and DUT Antenna .......................................................................................... 5 2.1 Test photos ............................................................................................................................................ 5 2.2 Test Condition ...................................................................................................................................... 5 2.3 DUT Antenna ....................................................................................................................................... 6 3.2D-3D Radiation pattern ............................................................................................................................... 7 3.1 2D Radiation pattern test results ........................................................................................................... 7 3.2 3D Radiation pattern test results ........................................................................................................... 8 4.Peak Gain ...................................................................................................................................................... 9 3.3 Test results ........................................................................................................................................... 9 Report No.: RF8230406039-L1-R Page 4 of 10 1.Purose & Environment 1.1 Purpose • Meet the electrical performance index; • Confirm the antenna scheme to meet the design requirements; 1.2 Environment • Test Condition: the network analyzer(E5071C) and SATIMO microwave anechoic chamber • Passive measurement results are presented Report No.: RF8230406039-L1-R Page 5 of 10 2.Test photos、Test Condition and DUT Antenna 2.1 Test photos Microwave anechoic chamber 2.2 Test Condition The network Analyzer Report No.: RF8230406039-L1-R Page 6 of 10 2.3 DUT Antenna Antenna Report No.: RF8230406039-L1-R Page 7 of 10 3 2D Radiation pattern 3.1 2D Radiation pattern test results Antenna_2D Report No.: RF8230406039-L1-R Page 8 of 10 3 3D Radiation pattern 3.2 3D Radiation pattern test results Antenna_3D Report No.: RF8230406039-L1-R Page 9 of 10 4 Peak Gain 4.1Test results Antenna_Peak Gain Frequency(MHz) Peak_Gain . dBi 2400 -3.52746 2410 -2.85367 2420 -2.15516 2430 -1.78412 2440 -1.69437 2450 -1.55137 2460 -1.49915 2470 -1.37612 2480 -1.49079 2490 -1.57472 2500 -1.7318 Report No.: RF8230406039-L1-R Page 10 of 10 STATEMENT a) The test report applies only to the specific samples tested under conditions. b) The test report is invalid without the Inspection Seal. c) The test report is invalid without the signature of the test engineer, auditor, Approver. d) The test report is invalid if it is altered or copied. e) Partial replica is prohibited without permission of Shenzhen HAIYUN Testing Co., Ltd. Laboratory f) The test results presented in this report is only valid on the tested samples. g) Objections to this report should be submitted to the inspection organization in 15 days of receipting the report. It is not accepted if overdue. Shenzhen HAIYUN Testing Co., Ltd. Laboratory Address: No. 2 Danzi North Road, Kengzi Street, Pingshan District,Shenzhen,Guangdong, China Tel: 0755-26021222 Fax: 0755-26021723 (END OF REPORT)

Contact Information

Applicant

Lan Yingting(QA)
[email protected]Fax: 0571-81957750

Technical Contact

CTI U.S. Inc.Robin Zhang
[email protected]

Suite 230,1455 CTI U.S.Inc.Lincoln Parkway · Atlanta, Georgia, 30346 · United States

Test Firm

MRT Technology (Taiwan) Co.,LtdChenz Ker
[email protected]Fax: +886-3-328-8918

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.90 mW
Confidentiality
Long Term
Grant Notes
Power Output is conducted. This is a portable device. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance.