FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Radixon s.r.o/
  3. 2AQYWG6I9

2AQYWG6I9HF/VHF/UHF/SHF Receiver

Radixon s.r.o
HF/VHF/UHF/SHF Receiver - FCC ID 2AQYWG6I9 - Radixon s.r.o
Click to zoom

Application Details

Equipment Class
JAB - Part 15 Class B Digital Device
Date of Grant
Aug 14, 2024
Application Purpose
Original Equipment
Date of Application
Aug 14, 2024
Equipment Note
HF/VHF/UHF/SHF Receiver
Company
Radixon s.r.o
Country
Slovak Republic

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WiNRADiO ® by RADIXON ® WR-G69DDCe WR- G69DDCi Excelsior Ultra TM HF/VHF/UHF/SHF Receiver User’s Guide Ver. 1.42 WR-G69DDCe and WR-G69DDCi User’s Guide 2 All rights reserved. No part of this book may be reproduced or transmitted in any form or by any means without the written permission of the publisher. Trademarks WiNRADiO, G3, G69DDC and Excelsior Ultra are trademarks of WiNRADiO Communications All other brand and product names are trademarks of their respective owners. Published in Australia WR-G69DDCe and WR-G69DDCi User’s Guide 3 FCC Notice The WiNRADiO WR-G69DDC receiver has been tested and found to comply with the limits for a Class B digital device, pursuant to FCC CFR Title 47 Part 15 Subpart B. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and the receiver • Connect the computer into a different outlet so that the two devices are on different branch circuits • Consult an authorised dealer or an experienced radio/TV technician for help Caution To comply with the limits for the Class B digital device, pursuant to FCC CFR Title 47 Part 15 Subpart B, the WiNRADiO receiver must be attached to a computer certified to comply with the Class B limits. Only peripherals certified to comply with the Class B limits may be attached to the computer containing the WiNRADiO receiver. All cables used to connect the computer and peripherals must be shielded and grounded. Operation with non-certified peripherals may result in interference to radio and TV reception. Modifications Any changes or modifications to the WiNRADiO receiver not expressly approved in this book could void the user's authority to operate this equipment. Limitation of Liability and Remedies The information published in this book has been compiled from several sources. While every effort has been made to ensure its accuracy, neither the authors nor the publisher can guarantee that all information is entirely correct or up-to-date. Furthermore, neither the authors nor the publisher can take any responsibility for the use of this information or any consequences arising therefrom. WiNRADiO Communications shall have no liability for any damages due to lost profits, loss of use or anticipated benefits, or other incidental, special or punitive damages arising from the use of, or the inability to use, the WiNRADiO receiver, whether arising out of contract, negligence, tort or under any warranty, even if WiNRADiO Communications has been advised of the possibility of such damages. In no event shall WiNRADiO Communications' liability for damages exceed the amount paid for this product. WiNRADiO Communications neither assumes nor authorises anyone to assume for it any other liabilities. Warning In certain countries or states it may be illegal to monitor certain frequencies. We cannot accept any responsibility for the consequences of your non-compliance with government regulations. If you are in doubt about the regulations in your country or state, please contact your nearest radio communications regulatory authority. WR-G69DDCe and WR-G69DDCi User’s Guide 4 Table of Contents Table of Contents ......................................................................................... 4 Introduction ................................................................................................... 6 The Hardware ................................................................................................ 7 Installation ..................................................................................................... 9 Recommended System Requirements ....................................................... 9 Software and Hardware Installation .......................................................... 10 Setting up the Sound Card ....................................................................... 13 Connecting the Antenna ........................................................................... 14 Grounding ................................................................................................. 14 Getting Started ............................................................................................ 16 Achieving Best Selectivity ......................................................................... 19 Avoiding Front-End Overload ................................................................... 20 Inside the Excelsior Ultra .......................................................................... 21 Resizing the Application Window ............................................................. 25 Drop-Down Menu Controls ........................................................................ 26 Tuning the Excelsior Ultra ......................................................................... 27 Manual Frequency Entry ........................................................................... 27 Tuning Knob .............................................................................................. 30 Keyboard Tuning....................................................................................... 30 Multiple Receiver Operation ..................................................................... 31 Point-and-Click Tuning ............................................................................. 32 Dragging the Passband …

Text truncated - open the document above for the full version.

Attestation Statements

Radixon s.r.o Address: Opatska 19, 04018 Kosice-Krasna, Slovak Republic Tel: +421557292043 Email: [email protected] Date: 2024-06-24 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Attestation letter Dear Sir or Madam, Our product HF/VHF/UHF/SHF Receiver, model: WR-G69DDCi, FCC ID: 2AQYWG6I9, for marketing purpose, this product only supports Range 1: 8 kHz to 80 MHz; Range 2: 43 MHz to 8 GHz (FM and AM modes). The other functions, bands and modes was disabled to use by manufacturer in the software, the end user has no capability to activate it. Sincerely, Signature Branislav Kocper Managing Director

External Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 1 of 3 EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 2 of 3 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 3 of 3 Frequency reference input Frequency reference output Range 1 antenna input port Range 2 antenna input port

ID Label/Location Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)

Internal Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 1 of 14 EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 2 of 14 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 3 of 14 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 4 of 14 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 5 of 14 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 6 of 14 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 7 of 14 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 8 of 14 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 9 of 14 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 10 of 14 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 11 of 14 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 12 of 14 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 13 of 14 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S70030-RF Page 14 of 14

Test Report

Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF024-1 Page 1 of 103 Version 1.0 (2023/10/07) TEST REPORT Applicant Name: Radixon s.r.o Address: Opatska 19, 04018 Kosice-Krasna, Slovak Republic Report Number: 2401S70030-RF-00 FCC ID: 2AQYWG6I9 Test Standard (s) FCC Part 15, Subpart B (Class B) Sample Description Product Type: HF/VHF/UHF/SHF Receiver Model No.: WR-G69DDCi Multiple Model(s) No.: N/A Trade Mark: WiNRADiO Date Received: 2024/04/09 Issue Date: 2024/07/24 Test Result: Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By: Approved By: Bruce Lin Nancy Wang EMC Engineer EMC Supervisor Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S70030-RF-00 TR-EM-RF024-1 Page 2 of 103 Version 1.0 (2023/10/07) TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 3 GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 MEASUREMENT UNCERTAINTY .................................................................................................................................... 4 TEST FACILITY ............................................................................................................................................................. 5 SYSTEM TEST CONFIGURATION .......................................................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 6 OPERATION FREQUENCY AND TEST CHANNEL ............................................................................................................. 6 EUT EXERCISE SOFTWARE ........................................................................................................................................... 6 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 6 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 6 EXTERNAL I/O CABLE .................................................................................................................................................. 7 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 7 SUMMARY OF TEST RESULTS ............................................................................................................................... 9 TEST EQUIPMENT LIST ......................................................................................................................................... 10 FCC §15.107 - AC LINE CONDUCTED EMISSIONS ............................................................................................ 12 APPLICABLE STANDARD ............................................................................................................................................ 12 EUT SETUP ................................................................................................................................................................ 12 EMI TEST RECEIVER SETUP ....................................................................................................................................... 12 TEST PROCEDURE ...................................................................................................................................................... 13 LEVEL & OVER LIMIT CALCULATION ....................................................................................................................... 13 TEST DATA ................................................................................................................................................................ 13 FCC §15.109 - RADIATED EMISSIONS ................................................................................................................. 38 APPLICABLE STANDARD ............................................................................................................................................ 38 EUT SETUP ..................................................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S70030-RF Page 1 of 4 EXHIBIT A - TEST SETUP PHOTOGRAPHS Conducted Emissions - Front View Conducted Emissions - Side View Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S70030-RF Page 2 of 4 Radiated Emissions - Front View (Below 1 GHz) Radiated Emissions - Rear View (Below 1 GHz) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S70030-RF Page 3 of 4 Radiated Emissions - Front View (1-18 GHz) Radiated Emissions - Rear View (1-18 GHz) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S70030-RF Page 4 of 4 Radiated Emissions - Front View (18-40 GHz) Radiated Emissions - Rear View (18-40 GHz)

Contact Information

Applicant

Branislav Kocper
[email protected]+421557292043Fax: +421557292045

Test Firm

Bay Area Compliance Laboratories Corp (Shenzhen)Well Wang
[email protected]86-755-33320018

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from Radixon s.r.o

G6 external wideband receiver up to 8 GHz - FCC ID 2AQYWG6E9 - Radixon s.r.o
2AQYWG6E9

G6 external wideband receiver up to 8 GHz

Jan 24, 2021

Equipment Class

JAB - Part 15 Class B Digital Device