FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Satellite Electronic(Zhong Shan)Ltd./
  3. 2AQZU-18017

2AQZU-18017CEILING FAN WALL REMOTE CONTROLLER

Satellite Electronic(Zhong Shan)Ltd.
CEILING FAN WALL REMOTE CONTROLLER - FCC ID 2AQZU-18017 - Satellite Electronic(Zhong Shan)Ltd.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Sep 21, 2020
Application Purpose
Original Equipment
Date of Application
Sep 20, 2020
Equipment Note
CEILING FAN WALL REMOTE CONTROLLER
Frequency Range
304.25000000 - 304.25000000
Company
Satellite Electronic(Zhong Shan)Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

DC POWER CEILING FAN WALL CONTROL MANUAL ACTIVATING THE LEARNING PROCESS 1. After installation is complete, AC power is turned on within 30 seconds, press and hold the LEARN button for 1~3 seconds. The receiver will make sound, Bi, once. This will indicate the receiver has learned the ID that was previously selected on the transmitter. Then the wall transmitter can control the receiver. 2. If user cannot finish the setting within the 30 seconds time frame, the main power must be turned off and re-started again. This will reset the unit. Repeat step 1 until the LEARNING feature is activated as indicated. LIGHT FUNCTION SELECT SWITCH If installed energy light onto ceiling fan, please set the “light function select switch” “light function select switch” to O position. If installed tungsten light onto ceiling fan, please set the “light function select switch” to D position. WALL TRANSMITTER OPERATION Press button 1~6 to set fan speed Press this button to turn the fan off. Press this button to set fan wind direction up or down. ON/OFF—Press this button and release instantly to turn on or off the light. DIMMER—Press and hold to dim or brighten lights to the desired level and release. (Tungsten bulb only) When pressing remote button, the LED indicator would be on. TRANSMITTER Installing Wall Control (TRANSMITTER): Remove wall plate, disconnect and remove the toggle switch from wall junction box. Using the wire connectors, make the electrical connections to the wall control (transmitter) unit. Carefully push all connected wires inside wall switch box. Secure wall control unit with 2 screws previously removed. Face plate could be locked onto the transmitter. To assure continued FCC compliance: FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. CAUTION: To assure continued FCC compliance: Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. FCC ID:2AQZU-18017 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

ID Label/Location Info

Reference N Waltek Tes http://www EXHIBI Proposed Specificatio n it is visible durable to r expected lif e Proposed No.: WTH20X sting Group w.semtest.co T 1 - PRO FCC ID La ns: The label or easily acc emain fully l etime. Label Loca X08054462W (Shenzhen) m.cn ODUCT L abel Forma shall be secu cessible to th legible and in ation on EU W Co., Ltd. LABELIN at FCC ID urely affixed t he user, and ntact on the UT FCC NG : 2AQZU-1 to a permane shall not be device in al l ID Label Lo 18017 ently attached readily detac l normal cond cation d part of the d chable. The l ditions of use device, in a lo label shall be e throughout ocation where e sufficiently t the device’s e y s

Internal Photos

Reference N Waltek Tes http://www EXHIBI EUT Housi n Solder Boa r No.: WTH20X sting Group w.semtest.co T 3 - EUT ng and Boar rd-Compone X08054462W (Shenzhen) m.cn T INTER rd View 1 ent View 1 W Co., Ltd. NAL PHO OTOGRA APHS Reference N Waltek Tes http://www Solder Boa r Solder Boa r No.: WTH20X sting Group w.semtest.co rd-Compone rd-Compone X08054462W (Shenzhen) m.cn ent View 2 ent View 3 W Co., Ltd. SR RD Antenna. Reference N Waltek Tes http://www Solder Boa r Solder Boar No.: WTH20X sting Group w.semtest.co rd-Compone rd-Compone X08054462W (Shenzhen) m.cn ent View 4 ent View 5 W Co., Ltd. Reference N Waltek Tes http://www Solder Boa r No.: WTH20X sting Group w.semtest.co rd-Compone X08054462W (Shenzhen) m.cn ent View 6 W Co., Ltd.

Test Report

Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Page 1 of 24 TEST REPORT Reference No. .................... : WTH20X08054462W FCC ID ................................ : 2AQZU-18017 Applicant ........................... : Satellite Electronic(Zhong shan)Ltd. Address ............................. : No.8, Chuang Ye Road, Torch Development Zone, Zhongshan, Guangdong, China. Product Name ................... : CEILING FAN WALL REMOTE CONTROLLER Test Model. ........................ : TR340A-2 Standards .......................... : FCC Part 15.231 Date of Receipt sample .... : Aug.11, 2020 Date of Test........................ : Aug.11, 2020 to Aug.20, 2020 Date of Issue ..................... : Aug.20, 2020 Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Tested by: Reviewed By: Approved & Authorized By: Jack Huang / Project Engineer Lion Cai / RF Manager Silin Chen / Manager Reference No.: WTH20X08054462W Page 2 of 24 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn TABLE OF CONTENTS 1. GENERAL INFORMATION ................................................................................................................................... 4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ............................................................................... 4 1.2 TEST STANDARDS ................................................................................................................................................... 5 1.3 TEST METHODOLOGY ............................................................................................................................................. 5 1.4 TEST FACILITY ....................................................................................................................................................... 5 1.5 EUT SETUP AND TEST MODE ................................................................................................................................. 6 1.6 MEASUREMENT UNCERTAINTY .............................................................................................................................. 6 1.7 TEST EQUIPMENT LIST AND DETAILS ..................................................................................................................... 7 2. SUMMARY OF TEST RESULTS ........................................................................................................................... 8 3. ANTENNA REQUIREMENT .................................................................................................................................. 9 3.1 STANDARD APPLICABLE ......................................................................................................................................... 9 3.2 TEST RESULT.......................................................................................................................................................... 9 4. RADIATED EMISSIONS ....................................................................................................................................... 10 4.1 STANDARD APPLICABLE ....................................................................................................................................... 10 4.2 TEST PROCEDURE ................................................................................................................................................. 11 4.3 CORRECTED AMPLITUDE & MARGIN CALCULATION ............................................................................................ 12 4.4 SUMMARY OF TEST RESULTS/PLOTS .................................................................................................................... 12 5. 20DB BANDWIDTH ............................................................................................................................................... 15 5.1 STANDARD APPLICABLE ....................................................................................................................................... 15 5.1 TEST PROCEDURE ................................................................................................................................................. 15 5.2 SUMMARY OF TEST RESULTS/PLOTS .................................................................................................................... 15 6. TRANSMISSION TIME ......................................................................................................................................... 17 6.1 STANDARD APPLICABLE ....................................................................................................................................... 17 6.2 TEST PROCEDURE ................................................................................................................................................. 17 6.3 SUMMARY OF TEST RESULTS/PLOTS .................................................................................................................... 17 7. DUTY CYCLE ......................................................................................................................................................... 19 7.1 STANDARD APPLICABLE ....................................................................................................................................... 19 7.2 TEST PROCEDURE .....................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Reference N Waltek Tes http://www EXHIBI Conducted Radiation E No.: WTH20X sting Group w.semtest.co T 4 - TES Emission Te Emission Tes X08054462W (Shenzhen) m.cn ST SETUP est Setup st Setup (Belo W Co., Ltd. P PHOTO ow 30MHz) OGRAPH HS Reference N Waltek Tes http://www Radiation E Radiation E No.: WTH20X sting Group w.semtest.co Emission Tes Emission Tes X08054462W (Shenzhen) m.cn st Setup (30M st Setup (1GH W Co., Ltd. MHz to 1GHz Hz to 18GHz z) z) Reference N Waltek Tes http://www Radiation E No.: WTH20X sting Group w.semtest.co Emission Tes X08054462W (Shenzhen) m.cn st Setup (Abo W Co., Ltd. ove 18GHz)

Contact Information

Applicant

sean zheng(Manager)
[email protected]+8618933362018Fax: +86-0760-22582768

Test Firm

Waltek Testing Group (Shenzhen) Co., Ltd.Jandy So
[email protected]86 755 33663308Fax: 86-755-33663309

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231304.25 MHz - 304.25 MHz-
Confidentiality
Long Term

Other Applications from Satellite Electronic(Zhong Shan)Ltd.

CEILING FAN REMOTE CONTROL - FCC ID 2AQZU-18085 - Satellite Electronic(Zhong Shan)Ltd.
2AQZU-18085

CEILING FAN REMOTE CONTROL

Sep 10, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Ceiling Fan Wall Control - FCC ID 2AQZU-18083 - Satellite Electronic(Zhong Shan)Ltd.
2AQZU-18083

Ceiling Fan Wall Control

Aug 24, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
CEILING FAN REMOTE CONTROL - FCC ID 2AQZU-18073 - Satellite Electronic(Zhong Shan)Ltd.
2AQZU-18073

CEILING FAN REMOTE CONTROL

Dec 04, 2025

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
CEILING FAN REMOTE CONTROL - FCC ID 2AQZU-18071 - Satellite Electronic(Zhong Shan)Ltd.
2AQZU-18071

CEILING FAN REMOTE CONTROL

Nov 27, 2025

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
CEILING FAN REMOTE CONTROL - FCC ID 2AQZU-18075 - Satellite Electronic(Zhong Shan)Ltd.
2AQZU-18075

CEILING FAN REMOTE CONTROL

Nov 27, 2025

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter