Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
HavenLock Inc - 10x stronger than the deadbolt v 1.0 Patent pending in one or more countries Âź âą HAVEN CONNECT Z High-strength, Z-Wave enabled smart lock. Safety, Warnings, Regulations Warranty Getting Started Preparing Your HAVEN Installation LED and Sounds Z-Wave Operation Troubleshooting Important Safeguards 1 3 4 5 6 9 10 16 16 User Manual Need help? Contact us at [email protected] HAVEN will not prevent someone from accessing your home via other means. HAVEN will not prevent someone from getting through your door if they use special tools. HAVEN is designed as barrier to prevent a closed door from being forced inward into a dwelling when blunt forced is used against the middle section of the door near the outside door handle. Any other entry attempt does not fall under the product definition or purpose of HAVEN Lock. For instance, a person who uses a special tool to remove the door or any elements of the door or attempts to cross the barrier of the door through an opening does not fall under the defined use of HAVEN Lock. If you experienced a break in attempt with HAVEN installed we recommend that you replace your HAVEN. Do not attempt to disassemble unit or remove components that are not explicitly stated in the installation manual. Do not press down on the pedal and locking gate at the same time. Owner is responsible for providing alternative access to the building in the event of fire, potential smoke inhalation, carbon dioxide event, or other home emergency not listed explicitly here. Owner is responsible to ensure proper fit and correct installation. Owner is responsible for safety of themselves and others. If you are unsure if this product is WARNING ! This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. CAUTION, used without the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in harm to yourself and others. NOTICE is used to address safe-use practices not related to personal injury. WARNING CAUTION CAUTION NOTICE Explanation of Attention Words and Symbols used in this guide Important Safety Instructions 1 HAVEN CONNECT Z WARNING: Changes or modifications which are not expressly approved by HavenLock Inc could void the userâs authority to operate the equipment. AVERTISSEMENT: Les changements ou modifications qui ne sont pas approuvĂ©s par HavenLock Inc pourrait annuler l'autoritĂ© de l'utilisateur de faire fonctionner l'Ă©quipement This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadaâs licence-exempt RSS(s). Operation is subject to the following two conditions: 1) This device may not cause interference. 2) This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil contient des Ă©metteurs / rĂ©cepteurs exemptĂ©s de licence conformes aux RSS (RSS) d'Innovation, Sciences et DĂ©veloppement Ă©conomique Canada. Le fonctionnement est soumis aux deux conditions suivantes: 1) Cet appareil ne doit pas causer d'interfĂ©rences. 2) Cet appareil doit accepter toutes les interfĂ©rences, y compris celles susceptibles de provoquer un fonctionnement indĂ©sirable de l'appareil. This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health Canada Safety Code 6. The system must be installed at a minimum separation distance from the antenna to a general bystander of xx inches (xx cm) to maintain compliance with the General Population limits. Lâexposition aux radiofrĂ©quences de ce systĂšme a Ă©tĂ© Ă©valuĂ©e selon la norme RSS-102 et est jugĂ©e conforme aux limites Ă©tablies par le Code de sĂ©curitĂ© 6 de SantĂ© Canada. Le systĂšme doit ĂȘtre installĂ© Ă une distance minimale de xx pouces (xx cm) sĂ©parant lâantenne dâune personne prĂ©sente en conformitĂ© avec les limites permises dâexposition du grand public This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. HAVEN Connect Z HavenLock Inc Model: HL1-CNT-001-Z FCC ID: 2ARFQHL1CNT001Z IC: 24389-HL1CNT001Z Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: âą Reorient or relocate the receiving antenna âą Increase the separation between the equipment and receiver âą Connect the equipment into an outlet on a different circuit from the one the receiver is connected âą Consult the dealer or an experienced radio/TV technician for help REGULATORY INFORMATION NOTICE To avoid damage to the unit, do not use on wet surfaces or damp locations. The product is designed for indoor use only. Do not expose to weather elements as this may affect functionality. To avoid potential damage to your unit, do not simulate a break in. Damage to the unit mâŠ
Text truncated - open the document above for the full version.
HavenLock Inc - 10x stronger than the deadbolt v 1.0 Patent pending in one or more countries Âź âą HAVEN Lockdown Z High-strength, Z-Wave enabled smart lock. Safety, Warnings, Regulations Warranty Getting Started Preparing Your HAVEN Installation LED and Sounds Z-Wave Operation Troubleshooting Important Safeguards 1 3 4 5 6 9 10 16 16 User Manual Need help? Contact us at [email protected] HAVEN will not prevent someone from accessing your home via other means. HAVEN will not prevent someone from getting through your door if they use special tools. HAVEN is designed as barrier to prevent a closed door from being forced inward into a dwelling when blunt forced is used against the middle section of the door near the outside GRRUKDQGOH$Q\RWKHUHQWU\DWWHPSWGRHVQRWIDOOXQGHUWKHSURGXFWGHÈŽQLWLRQRUSXUSRVHRI HAVEN Lock. For instance, a person who uses a special tool to remove the door or any elements of the door or attempts to cross the barrier of the door through an opening does QRWIDOOXQGHUWKHGHÈŽQHGXVHRI+$9(1/RFN If you experienced a break in attempt with HAVEN installed we recommend that you replace your HAVEN. Do not attempt to disassemble unit or remove components that are not explicitly stated in the installation manual. Do not press down on the pedal and locking gate at the same time. 2ZQHULVUHVSRQVLEOHIRUSURYLGLQJDOWHUQDWLYHDFFHVVWRWKHEXLOGLQJLQWKHHYHQWRIÈŽUH potential smoke inhalation, carbon dioxide event, or other home emergency not listed explicitly here. 2ZQHULVUHVSRQVLEOHWRHQVXUHSURSHUÈŽWDQGFRUUHFWLQVWDOODWLRQ Owner is responsible for safety of themselves and others. If you are unsure if this product is WARNING ! This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. CAUTION, used without the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in harm to yourself and others. NOTICE is used to address safe-use practices not related to personal injury. WARNING CAUTION CAUTION NOTICE Explanation of Attention Words and Symbols used in this guide Important Safety Instructions 1 HAVEN CONNECT Z WARNING: Changes or modi!cations which are not expressly approved by HavenLock Inc could void the userâs authority to operate the equipment. AVERTISSEMENT: Les changements ou modi!cations qui ne sont pas approuvĂ©s par HavenLock Inc pourrait annuler l'autoritĂ© de l'utilisateur de faire fonctionner l'Ă©quipement This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadaâs licence-exempt RSS(s). Operation is subject to the following two conditions: 1) This device may not cause interference. 2) This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil contient des Ă©metteurs / rĂ©cepteurs exemptĂ©s de licence conformes aux RSS (RSS) d'Innovation, Sciences et DĂ©veloppement Ă©conomique Canada. Le fonctionnement est soumis aux deux conditions suivantes: 1) Cet appareil ne doit pas causer d'interfĂ©rences. 2) Cet appareil doit accepter toutes les interfĂ©rences, y compris celles susceptibles de provoquer un fonctionnement indĂ©sirable de l'appareil. This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits speci!ed by Health Canada Safety Code 6. The system must be installed at a minimum separation distance from the antenna to a general bystander of xx inches (xx cm) to maintain compliance with the General Population limits. Lâexposition aux radiofrĂ©quences de ce systĂšme a Ă©tĂ© Ă©valuĂ©e selon la norme RSS-102 et est jugĂ©e conforme aux limites Ă©tablies par le Code de sĂ©curitĂ© 6 de SantĂ© Canada. Le systĂšme doit ĂȘtre installĂ© Ă une distance minimale de xx pouces (xx cm) sĂ©parant lâantenne dâune personne prĂ©sente en conformitĂ© avec les limites permises dâexposition du grand public This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. HAVEN Lockdown Z HavenLock Inc Model: HL1-CNT-001-LDZ FCC ID: 2ARFQHL1CNT001Z IC: 24389-HL1CNT001Z Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o" and on, the user is encouraged to try to correct the interference by one or more of the following measures: âą Reorient or relocate the receiving antenna âą Increase the separation between the equipment and receiver âą Connect the equipment into an outlet on a di"erent circuit from the one the receiver is connected âą Consult the dealer or an experienced radio/TV technician for help REGULATORY INFORMATION NOTICE To avoid damage to the unit, do not use on wet surfaces or damp locations. The product is designed for indoor XVHRQO\'RQRWH[SRVHWRZHDWKHUHOHPHQWVDVWKLVPD\DÎHFWIXQFWLRQDOLW\ 7RDYRLGSRWHQWLDOGDPDJHWR\RXUXQLWGRQRWVLPXODWHDEUHDNLQ'DPDJHWRWKHXQLWPD\DâŠ
Text truncated - open the document above for the full version.
Date: April 16,2020 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: 2ARFQHL1CNT001Z To whom it may concern: We, the undersigned, hereby authorize SGS North America, Inc. to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with HavenLock, Inc. This authorization is valid until further written notice from the applicant. Name (Printed): Alex Bertelli Title: CEO Signature: On behalf of Company: HavenLock, Inc. Telephone: 615.478.4331
To: SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: HavenLock Inc. 188 Front Street Suite 116-112 Franklin, TN 37064 Regarding: Confidentiality Request regarding application for FCC ID 2ARFQHL1CNT001Z LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commissionâs rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. SHORT TERM CONFIDENTIALITY Additionally, the applicant requests the following documents be held confidential until the device is marketed or 180 days from the grant date, whichever is less. If the device is marketed within 180 days of the Grant Date, the applicant will notify the TCB per FCC KDB 726920 D01 Confidentiality Request Procedures. External Photos Internal Photos Test Setup Photos User manual(s) Sincerely, Aaron S. Froehlich EMC Test Engineer, SGS North America Authorized Agent for: HavenLock Inc. 28 April 2020
EXTERNAL PHOTOS FCC ID: 2ARFQHL1CNT001Z IC: 24389-HL1CNT001Z 2 © SGS SA 2016 ALL RIGHTS RESERVED 3 © SGS SA 2016 ALL RIGHTS RESERVED 4 © SGS SA 2016 ALL RIGHTS RESERVED WWW.SGS.COM
INTERNAL PHOTOS FCC ID: 2ARFQHL1CNT0001Z IC: 24389-HL1CNT001Z 2 © SGS SA 2016 ALL RIGHTS RESERVED 3 © SGS SA 2016 ALL RIGHTS RESERVED 4 © SGS SA 2016 ALL RIGHTS RESERVED 5 © SGS SA 2016 ALL RIGHTS RESERVED 6 © SGS SA 2016 ALL RIGHTS RESERVED 7 © SGS SA 2016 ALL RIGHTS RESERVED WWW.SGS.COM
Test Report Number: 4602458EMC03 Rev: 0 HavenLock Inc. / HL1-CNT-001-Z Page: 1 of 5 Remarks: This report details the results of the testing carried out on one sample, the results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This document is issued by the Company under its General Conditions of Service accessible at http://www.sgs.com/en/Terms-and- Conditions.aspx. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Companyâs findings at the time of its intervention only and within the limits of Clientâs instructions, if any. The Companyâs sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. RF Exposure Report Project Number: 4602458 Proposal Number: 10607 Report Number: 4602458EMC03 Revision Level: 0 Client: HavenLock Inc. Equipment Under Test: Electrically Operated Security Door Lock PMN: Haven Connect Z Model: HL1-CNT-001-Z FCC ID: 2ARFQHL1CNT001Z Applicable Standards: 47 CFR §§ 2.1093; FCC KDB 447498 D01 General RF Exposure Guidance v06 Report issued on: 28 April 2020 Test Result: SAR Evaluation Exempt Prepared by: Aaron S. Froehlich, EMC Project Engineer Reviewed by: Stephen Whalen, Lab Manager Test Report Number: 4602458EMC03 Rev: 0 HavenLock Inc. / HL1-CNT-001-Z Page: 2 of 5 SGS North America Inc. Consumer and Retail 620 Old Peachtree Road NW, Suite 100, Suwanee, GA 30024 t (770) 570-1800 www.sgs.com Member of the SGS Group (SGS SA) TABLE OF CONTENTS 1 GENERAL INFORMATION ............................................................................................................................................. 3 1.1 CLIENT INFORMATION ................................................................................................................................................... 3 1.2 TEST LABORATORY ....................................................................................................................................................... 3 1.3 GENERAL INFORMATION OF EUT .................................................................................................................................. 3 1.4 TRANSMITTER SPECIFICATION ....................................................................................................................................... 3 1.5 OPERATING MODES AND CONDITIONS .......................................................................................................................... 3 2 RF EXPOSURE ................................................................................................................................................................... 4 3 REVISION HISTORY ........................................................................................................................................................ 5 Test Report Number: 4602458EMC03 Rev: 0 HavenLock Inc. / HL1-CNT-001-Z Page: 3 of 5 SGS North America Inc. Consumer and Retail 620 Old Peachtree Road NW, Suite 100, Suwanee, GA 30024 t (770) 570-1800 www.sgs.com Member of the SGS Group (SGS SA) 1 General Information 1.1 Client Information Name: HavenLock Inc. Address: 188 Front Street Suite 116-112 City, State, Zip, Country: Franklin, TN 37064 1.2 Test Laboratory Name: SGS North America, Inc. Address: 620 Old Peachtree Road NW, Suite 100 City, State, Zip, Country: Suwanee, GA 30024, USA Accrediting Body: A2LA Type of lab: Testing Laboratory Certificate Number: 3212.01 1.3 General Information of EUT Product Marketing Name (PMN): Haven Connect Z Model Number (HVIN): HL1-CNT-001-Z Electrically Identical (HVIN): HL1-CNT-001-LDZ Serial Number: 5244 Rated Voltage: 100-240Vac, 50/60Hz 1.4 Transmitter Specification Modulation Techniques: GFSK (Z Wave) Frequency Range: 908.4 â 908.4 MHz Antenna Type PCB Trace Antenna Frequency Range: 902 â 928 MHz 1.5 Operating Modes and Conditions Highest Reported Power levels were utilized for all calculations. Test Report Number: 4602458EMC03 Rev: 0 HavenLock Inc. / HL1-CNT-001-Z Page: 4 of 5 SGS North America Inc. Consumer and Retail 620 Old Peachtree Road NW, Suite 100, Suwanee, GA 30024 t (770) 570-1800 www.sgs.com Member of the SGS Group (SGS SA) 2 RF Exposure The maximum output power has been used to demonstrate compliance. Input Select Units Unit correction Max Power: -4.1dBm0.389045145 Min separation distance: 5mm5 Frequency, f: 908.4MHz908.4 Value reference Number v10mW v25mm v30.953 a) 1g Exclusion Threshold:15.7mW 10g Exlusion Threshold:39.3mW Values used for Calculation For 100 MHz to 6 GHz and test separation distances †50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: Conclusions: 447498 D01 General RF Exposure Guidance v06 SAR test exclusion calculations Section 4.3: General SAR test exclusion guidance / Section 4.3.1: Standalone SAR test exclusion considerations Reference number definition [max. power of channel, including tune-up tolerance, mW] 'Rounded to nearest mW [min. test separation distance, mm] 'Rounded to nearest mm [âf(GHz)] [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [âf(GHz)] †3.0 for 1-g SAR, and †7.5 for 10-g extremity SAR, <== 3 * v2 / v3 <== 7.5 * v2 / v3 The EUT max power is BELOW the threshold. SAR Testing is NOT required for Body applications The EUT max power is BELOW the threshold. SAR Testing is NOT required for Extremity applications Test Report Number: 4602458EMC03 Rev: 0 HavenLock IâŠ
Text truncated - open the document above for the full version.
Test Report Number: 4602458EMC02 Rev: 1 HavenLock Inc. / HL1-CNT-001-Z Page: 1 of 22 Remarks: This report details the results of the testing carried out on one sample, the results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This document is issued by the Company under its General Conditions of Service accessible at http://www.sgs.com/en/Terms-and- Conditions.aspx. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Companyâs findings at the time of its intervention only and within the limits of Clientâs instructions, if any. The Companyâs sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. RF Test Report Project Number: 4602458 Proposal Number: 10607 Report Number: 4602458EMC02 Revision Level: 1 Client: HavenLock Inc. Equipment Under Test: Electrically Operated Security Door Lock Product Marketing Name: Haven Connect Z HVIN HL1-CNT-001-Z FCC ID: 2ARFQHL1CNT001Z IC: 24389-HL1CNT001Z Applicable Standards: FCC Part 15 Subpart C, § 15.249 RSS-210, Issue 10, December 2019 (Annex F) RSS-GEN, Issue 5, March 2019 Amendment 1 ANSI C63.10: 2013 Report issued on: 6 May 2020 Test Result: Compliant Prepared by: Aaron S. Froehlich, EMC Project Engineer Reviewed by: Martin Taylor, EMC Project Engineer Test Report Number: 4602458EMC02 Rev: 1 HavenLock Inc. / HL1-CNT-001-Z Page: 2 of 22 SGS North America Inc. Consumer and Retail 620 Old Peachtree Road NW, Suite 100, Suwanee, GA 30024 t (770) 570-1800 www.sgs.com Member of the SGS Group (SGS SA) TABLE OF CONTENTS 1 SUMMARY OF TEST RESULTS ..................................................................................................................................... 3 1.1 MODIFICATIONS REQUIRED FOR COMPLIANCE .............................................................................................................. 3 2 GENERAL INFORMATION ............................................................................................................................................. 4 2.1 CLIENT INFORMATION ................................................................................................................................................... 4 2.2 TEST LABORATORY ....................................................................................................................................................... 4 2.3 GENERAL INFORMATION OF EUT .................................................................................................................................. 4 2.4 OPERATING MODES AND CONDITIONS .......................................................................................................................... 5 2.5 EUT CONNECTION BLOCK DIAGRAM ............................................................................................................................ 5 2.6 SYSTEM CONFIGURATIONS ............................................................................................................................................ 5 2.7 CABLE LIST ................................................................................................................................................................... 5 3 FIELD STRENGTH OF FUNDAMENTAL ..................................................................................................................... 6 3.1 TEST RESULT ................................................................................................................................................................. 6 3.2 TEST METHOD ............................................................................................................................................................... 6 3.3 TEST SITE ...................................................................................................................................................................... 6 3.4 TEST EQUIPMENT .......................................................................................................................................................... 6 3.5 TEST DATA .................................................................................................................................................................... 7 4 FIELD STRENGTH OF SPURIOUS RADIATION ........................................................................................................ 8 4.1 TEST RESULT ................................................................................................................................................................. 8 4.2 TEST METHOD ............................................................................................................................................................... 8 4.3 TEST SITE ...................................................................................................................................................................... 9 4.4 TEST EQUIPMENT .......................................................................................................................................................... 9 4.5 TEST DATA .................................................................................................................................................................. 10 5 BANDWIDTH .........................................................................................................................................âŠ
Text truncated - open the document above for the full version.
TEST SETUP PHOTOS FCC ID: 2ARFQHL1CNT0001Z IC: 24389-HL1CNT001Z 2 © SGS SA 2016 ALL RIGHTS RESERVED 3 © SGS SA 2016 ALL RIGHTS RESERVED 4 © SGS SA 2016 ALL RIGHTS RESERVED 5 © SGS SA 2016 ALL RIGHTS RESERVED WWW.SGS.COM
620 Old Peachtree Road NW · Suwanee, Georgia · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 908.4 MHz - 908.4 MHz | - |