FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. RFE BROADCAST S.R.L./
  3. 2ARJIDS100

2ARJIDS100FM BROADCAST TRANSMITTER

RFE BROADCAST S.R.L.
FM BROADCAST TRANSMITTER - FCC ID 2ARJIDS100 - RFE BROADCAST S.R.L.
Click to zoom

Application Details

Equipment Class
TBC - Licensed Broadcast Station Transmitter
Date of Grant
Jun 29, 2020
Application Purpose
Original Equipment
Date of Application
Jun 29, 2020
Equipment Note
FM BROADCAST TRANSMITTER
Frequency Range
87.50000000 - 108.00000000
Company
RFE BROADCAST S.R.L.
Country
Italy

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 USER MANUAL - TRANSMITTER DS SERIES - 30 - 50 - 100 - 500 - 1000W Rev 1.3 USER MANUAL TRANSMITTERS DS SERIES 30|50|100|300|500|1000W Rev 1.3 USER MANUAL - TRANSMITTER DS SERIES - 30 - 50 - 100 - 300 - 500 - 1000W 2 Index Indice ...................................................................................................2 Introduction & general information structure ......................................................4 Hazardous Voltage Warning .............................................................................4 General Safety Recommendations ....................................................................5 Document structure ........................................................................................6 Scope of the document ................................................................................... 6 Introduction ...................................................................................................7 Features ........................................................................................................10 Diagram block ................................................................................................11 Technical Specifications ..................................................................................12 Installation and Use ........................................................................................13 Front panel ....................................................................................................13 Rear panel .....................................................................................................14 Operating instructions .....................................................................................15 RF On/Off Switching ....................................................................................16 Fault/Reset Key ...........................................................................................17 Installation ....................................................................................................18 Unpacking ..................................................................................................18 First power-on and setup ..............................................................................18 Quick start ....................................................................................................19 Menu ..............................................................................................................20 Menu - Frequency ........................................................................................21 Menu - Power ..............................................................................................22 Menu - Audio Settings ..................................................................................22 Menu - Settings ...........................................................................................25 Lan configuration ......................................................................................26 Date/Time Settings ....................................................................................28 DB25 Settings ..........................................................................................29 Address port RS485 ..................................................................................30 19kHz Output Amplitude/Dev Amplitude/Dev Ph ...........................................30 Power Reduction Settings .............................................................................31 Set FSK/ID-Code Settings ..............................................................................32 AES/EBU Settings ........................................................................................32 Audio C.O./Reserve audio source ...................................................................33 Options Status .............................................................................................33 Preset - Settings ............................................................................................34 Alarms/Log Event ...........................................................................................36 3 USER MANUAL - TRANSMITTER DS SERIES - 30 - 50 - 100 - 500 - 1000W Rev 1.3 DB25 and DB9 pinout .....................................................................................Appendix A Touch screen calibration .................................................................................Appendix B Upgrade Firmware ..........................................................................................Appendix C Log-event and Alarms list ................................................................................Appendix D Web Page Control-SNMP .................................................................................Appendix E Support system ..............................................................................................Appendix F Rev 1.3 USER MANUAL - TRANSMITTER DS SERIES - 30 - 50 - 100 - 300 - 500 - 1000W 4 Introduction & general information structure This manual contains all informaƟ on for installaƟ on and maintenance of DS transmiƩ ers and is divided into two parts: the fi rst concerning operator that has to use equipment, the other concerning maintenance technicians. The two secƟ ons are separated by one blue page to quickly idenƟ fy them. The operator who normally has experience in using the equipment should not try to perform any acƟ on which has been classifi ed as belonging to the maintenance technician. Any incorrect operaƟ on may cause damage to equipment electronics and can be also potenƟ ally dangerous for operator’s safety. The RF power amplifi er has been designed for conƟ nuous wave (CW) modes. Technological cuƫ ng-edge soluƟ ons and latest generaƟ on materials (such as sixth generaƟ on LDMOS) ensure a high standard of quality and robustness. Hazardous Voltage Warnin…

Text truncated - open the document above for the full version.

Cover Letter(s)

MAKING BROADCAST SMARTER Federal Communications Commission Authorization and Evaluation Division RFE BROADCAST srl [email protected] - Nww rfebroadcast.com VAT: IT03406950794 - Numero REA CZ-198217 05.12.2019 Confidentiality Request regarding application for certification of FCC ID: 2ARJIDS50, FCC ID: 2ARJIDS100, FCC ID: 2ARJIDS500, FCC ID: 2ARJIDS3000, 2ARJIDS6000 Pursuant to Sections 0.457 and 0.459 of the Commission's Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type Block diagram S chematics Circuit Description Parts List Tuning Procedure The above materials contain trade secrets and proprietary information not customarily released to the p ublic. The public disclosure of these materials may be harmful to the applicant and provide u njustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Head Office: Via Marevitano 26, 88042 Falerna (CZ) -Italy Ph: +39 0968 1945299 - Fax: +39 0968 93134 Sates Office: Via Lisbona 10. 35127 Padova - Italy Ph: +39 049 7386741 - Fax: +39 049 8172028

External Photos

DS100 Photographic documentation 1 External photos 1.1 Top 1.2 Bottom 1.3 Left 1.4 Right 1.5 Front 1.6 Back

ID Label/Location Info

Option: RDS AES/EBU SNMP Option: RDS AES/EBU SNMP GSM AOIP ABRTS SNMPV2 GSM AOIP ABRTS SNMPV2 DS100 100W Analog FM Transmitter RFE 87,5MHz-108MHz 100-260Vac; F3,15A-F6,3A; 50Hz-60H RFE BROADCAST s.r.l. 5 T100A0419078 S/N:Model: Supply / Fuse type: Power Out / Description: Frequency (CW): IP20 (kg) 1595 via Marevitano, 26 - 88042 Falerna (CZ) - Italy RFE BROADCAST s.r.l. DS100 Model: T100A0419078 S/N: FCC ID: 2ARJIDS100 IC: 24642-DS100

Internal Photos

DS100 – Photographic documentation Internal photos 1.1 Overview 1.2 Power board 1.3 Analog RF modulator Top view Bottom view 1.4 Logic board Top view Bottom view 1.5 Display With cover Top view Bottom view 1.6 RF amplifer board Top view Buttom view

RF Exposure Info

849 NW STATE ROAD 45 PHONE: 888.472.2424 OR 352.472.5500 NEWBERRY, FL 32669 USA EMAIL: [email protected] WEB: HTTP://WWW.TIMCOENGR.COM An IIA Company RF Exposure Evaluation Report APPLICANT RFE BROADCAST S.R.L. ADDRESS VIA MAREVITANO N. 26 FALERNA (CZ) 88042 ITALY FCC ID 2ARJIDS100 IC 24642-DS100 MODEL NUMBER DS100 PRODUCT DESCRIPTION FM BROADCAST TRANSMITTER FINAL TEST DATE 1/14/2018 PREPARED BY Franklin Rose TEST RESULTS PASS FAIL Report Number Report Version Description Issue Date 2270UT18 MPETestReport_ Rev1 Initial Issue 12/4/2019 Rev2 Updated power output 06/29/2020 THE ATTACHED REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL WITHOUT THE WRITTEN APPROVAL OF TIMCO ENGINEERING, INC. TABLE OF CONTENTS GENERAL REMARKS ........................................................................................................ 2 GENERAL INFORMATION ................................................................................................ 3 ANTENNA INFORMATION ............................................................................................... 3 FCC MPE DISTANCE ........................................................................................................ 4 ISED MPE DISTANCE ...................................................................................................... 5 APPLICANT: RFE BROADCAST S.R.L. FCC ID: 2ARJIDS100 IC: 24642-DS100 Report: 2270UT18 MPE_TestReport_Rev2 Page 2 of 5 GENERAL REMARKS Summary The device under test does: Fulfill the general approval requirements as identified in this test report and was selected by the customer. Not fulfill the general approval requirements as identified in this test report Attestations This equipment has been tested in accordance with the standards identified in this test report. To the best of my knowledge and belief, these tests were performed using the measurement procedures described in this report. All instrumentation and accessories used to test products for compliance to the indicated standards are calibrated regularly in accordance with ISO 17025 requirements. I attest that the necessary measurements were made at: Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Designation #: US1070 Prepared by: Name and Title Franklin Rose, Project Director / EMC Specialist Date 06/29/2020 APPLICANT: RFE BROADCAST S.R.L. FCC ID: 2ARJIDS100 IC: 24642-DS100 Report: 2270UT18 MPE_TestReport_Rev2 Page 3 of 5 GENERAL INFORMATION EUT Description FM BROADCAST TRANSMITTER Model Number DS100 EUT Power Source ☒110–120Vac, 50– 60Hz ☐ DC Power (13.8 VDC) ☐ Battery Operated Test Item ☐ Engineering Prototype ☒ Pre-Production ☐ Production Type of Equipment ☒ Fixed ☐ Mobile ☐ Portable Antenna Connector External, N Type Test Conditions The temperature was 26ºC Relative humidity of 50%. Modification to the EUT No Modification to EUT. Applicable Standards FCC CFR 47 Part 2.1091 Test Facility Timco Engineering Inc. at 849 NW State Road 45 Newberry, FL 32669 USA. Designation #: US1070 ANTENNA INFORMATION Antenna is Provided Type Max Gain (dBi) No n/a 0.0 RF POWER OUTPUT Model Stable over Input Voltage Variation (+/- %) Output Power (W) Min Power 90% (W) Max Power 105% (W) DS30 5% 100 90 105 APPLICANT: RFE BROADCAST S.R.L. FCC ID: 2ARJIDS100 IC: 24642-DS100 Report: 2270UT18 MPE_TestReport_Rev2 Page 4 of 5 FCC MPE Distance FCC MPE Calculations Separation Distance (cm) Pow e r De nsity (mW/cm 2 ) Separation Distance (cm) Pow e r De nsity (mW/cm 2 ) 0.2 mW/cm2 Controlled Occupational RF Exposure/MPE Guideline 91.4 cm 1 mW/cm2 Uncontrolled Public RF Exposure/MPE Guideline 204.4 cm ParameterValueUnit EUT Form Factor Lowest Frequency88.000 MHz Highest Frequency108.000 MHz Maximum Power105.000 Tune Up Tolerance0.000 Duty Cycle100% % Antenna Gain0.000 Coax Loss0.000 EIRP105.000W EUT Parameters RF Exposure Field Strength Limits Separation Distance Calculation Method Uncontrolled Sep. Distance @ 0.2 mW/cm2 Controlled Sep. Distance @ 1 mW/cm2 EUT Power Density at 20 cm Calculation Method EUT Pow er Density @ 20 cm Calculations Public Persons may be exposed up to: Worst-Case RF Field Strength Limit for the General Public (Uncontrolled Environment) 0.2 mW/cm2 1 mW/cm2 Distance from Radiating Element (cm) = SQRT (P(mW) / 4π S(mW/cm 2 )) 204.4 cm 91.41 cm Power Density (mW/cm 2 ) = P(mW) / 4π R(cm) 2 Occupational Persons may be exposed up to: Worst-Case RF Field Strength Limit for Controlled Use (Controlled Environment) Mandatory distance from radiating element: 20.889 mW/cm2 APPLICANT: RFE BROADCAST S.R.L. FCC ID: 2ARJIDS100 IC: 24642-DS100 Report: 2270UT18 MPE_TestReport_Rev2 Page 5 of 5 ISED MPE Distance ISED MPE Calculations Separation Distance (cm) Pow e r De nsity (W/m 2 ) Separation Distance (cm) Pow e r De nsity (W/m 2 ) 254.4 cm 1.291 W/m2 113 cm 6.46 W/m2 Controlled Occupational RF Exposure/MPE Guideline Uncontrolled Public RF Exposure/MPE Guideline ParameterValueUnit EUT Form Factor Lowest Frequency88.000 MHz Highest Frequency108.000 MHz Maximum Power105.000 Tune Up Tolerance0.000 Duty Cycle100% % Antenna Gain0.000 Coax Loss0.000 EIRP105.000W EUT Parameters RF Exposure Field Strength Limits Separation Distance Calculation Method Uncontrolled Sep. Distance @ 1.291 W/m2 Controlled Sep. Distance @ 6.46 W/m2 EUT Power Density at 20 cm Calculation Method EUT Pow er Density @ 20 cm Mandatory distance from radiating element: 113.77 cm Power Density (mW/cm 2 ) = P(mW) / 4π R(cm) 2 1.291 W/m2 6.46 W/m2 Calculations Distance from Radiating Element (cm) = SQRT (P(mW) / 4π S(mW/cm 2 )) 254.41 cm Worst-Case RF Field Strength Limit for the General Public (Uncontrolled Environment) Worst-Case RF Field Strength Limit for Controlled Use (Controlled Environment) Public Persons may be exposed up to: Occupational Persons may be exposed up to: 208.89 W/m2

Test Report

849 NW STATE ROAD 45 PHONE: 352.472.5500 NEWBERRY, FL 32669 USA EMAIL: [email protected] WEB: HTTP://WWW.TIMCOENGR.COM An IIA Company FCC PART 73G & BETS 6 LOW POWER FM BROADCAST STATIONS (LPFM) TEST REPORT APPLICANT RFE BROADCAST S.R.L. VIA MAREVITANO N. 26 FALERNA (CZ) 88042 ITALY FCC ID 2ARJIDS100 IC 24642-DS100 MODEL NUMBER DS100 PRODUCT DESCRIPTION FM BROADCAST TRANSMITTER DATE SAMPLE RECEIVED 12/31/2018 DATE TESTED 1/14/2019 TESTED BY Tim Royer APPROVED BY Franklin Rose TEST RESULTS PASS FAIL Report Number Report Version Description Issue Date 2270UT18TestReport Rev1 Initial Issue 01/14/2019 Rev2 Updated Power Measurement Section 06/29/2020 THE ATTACHED REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL WITHOUT THE WRITTEN APPROVAL OF TIMCO ENGINEERING, INC. TABLE OF CONTENTS GENERAL REMARKS ........................................................................................................................................... 1 GENERAL INFORMATION ................................................................................................................................... 2 RESULTS SUMMARY ........................................................................................................................................... 3 RF POWER OUTPUT ........................................................................................................................................... 4 T EST DATA: RF OUTPUT POWER, MODEL DS100 ..................................................................................................... 5 FCC PART 2.1033(C)(8) ..................................................................................................................................... 5 P OWER IN THE FINAL STAGE .................................................................................................................................... 5 MODULATION CHARACTERISTICS ..................................................................................................................... 6 AUDIO FREQUENCY RESPONSE .......................................................................................................................... 7 T EST DATA: AUDIO FREQUENCY RESPONSE PLOT ........................................................................................................... 7 AUDIO INPUT VS MODULATION ........................................................................................................................ 8 T EST DATA: MODULATION LIMITING ........................................................................................................................... 9 OCCUPIED BANDWIDTH & EMISSION MASK .................................................................................................... 10 T EST DATA: OCCUPIED BANDWIDTH TABLE .......................................................................................................... 11 20 DB OCCUPIED BANDWIDTH PLOT LOW END OF BAND ........................................................................................... 11 20 DB OCCUPIED BANDWIDTH PLOT MIDDLE OF BAND ............................................................................................. 12 20 DB OCCUPIED BANDWIDTH PLOT HIGH END OF BAND .......................................................................................... 13 EMISSION MASK PLOT LOW END OF BAND ............................................................................................................. 14 EMISSION MASK PLOT MIDDLE OF BAND ............................................................................................................... 15 EMISSION MASK PLOT HIGH END OF BAND ............................................................................................................ 16 SPURIOUS EMISSIONS AT ANTENNA TERMINALS (CONDUCTED) .................................................................... 17 T EST DATA: LOW FREQUENCY ......................................................................................................................... 18 T EST DATA: MIDDLE FREQUENCY .................................................................................................................... 18 T EST DATA: HIGH FREQUENCY ........................................................................................................................ 19 FIELD STRENGTH OF SPURIOUS EMISSIONS ................................................................................................... 20 T EST DATA: LOW FREQUENCY ......................................................................................................................... 21 T EST DATA: MIDDLE FREQUENCY .................................................................................................................... 21 T EST DATA: HIGH FREQUENCY ........................................................................................................................ 22 FREQUENCY STABILITY ................................................................................................................................... 23 T EST DATA: FCC FREQUENCY STABILITY TABLE ........................................................................................................... 24 T EST DATA: FCC FREQUENCY STABILITY PLOT ............................................................................................................ 24 T EST DATA: IC FREQUENCY STABILITY TABLE ............................................................................................................. 25 T EST DATA: IC FREQUENCY STABILITY PLOT............................................................................................................... 25 STATE OF THE MEASUREMENT UNCERTAINTITY .............................................................................................. 26 EQUIPMENT LIST .........................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

TEST SETUP PHOTOGRAPHS Applicant: RFE BROADCAST S.R.L. FCC ID: 2ARJIDS100 IC: 24642-DS100 Conducted Measurements TEST SETUP PHOTOGRAPHS Field Strength of Spurious Emissions TEST SETUP PHOTOGRAPHS Frequency Stability

Contact Information

Applicant

Elena Ditadi(Sales Manager)
[email protected]39 345 8452439Fax: 39 345 8452439

Test Firm

Timco Engineering, Inc.Bruno Clavier
[email protected]352-472-5500Fax: 352 472 2030

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
17387.5 MHz - 108 MHz100 W180KF3E161.0000000000 Hz
Confidentiality
Long Term
Grant Notes
Power listed is conducted. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

Other Applications from RFE BROADCAST S.R.L.

FM BROADCAST TRANSMITTER - FCC ID 2ARJIDS3000 - RFE BROADCAST S.R.L.
2ARJIDS3000

FM BROADCAST TRANSMITTER

Jul 06, 2020

Equipment Class

TBC - Licensed Broadcast Station Transmitter
FM BROADCAST TRANSMITTER - FCC ID 2ARJIDS50 - RFE BROADCAST S.R.L.
2ARJIDS50

FM BROADCAST TRANSMITTER

Jun 29, 2020

Equipment Class

TBC - Licensed Broadcast Station Transmitter