2ARTN-00001HVAC Controller

Honeywell (Beijing) Technology Solutions Labs Co.,Ltd.
HVAC Controller - FCC ID 2ARTN-00001 - Honeywell (Beijing) Technology Solutions Labs Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Aug 16, 2020
Application Purpose
Original Equipment
Date of Application
Jul 27, 2020
Equipment Note
HVAC Controller
Frequency Range
2402.00000000 - 2480.00000000
Company
Honeywell (Beijing) Technology Solutions Labs Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

INSTALLATION INSTRUCTIONS ComfortPoint ™ Open CPO-PC400-W/CPO-PC400-UW HVAC CONTROLLER CPO-PC400-W/CPO-PC400-UW HVAC CONTROLLER EN0B-0085 IE10 R04202 CONTENTS General Safety Information ...............................................3 Technical Data .......................................................................4 Electrical Data ...............................................................................4 Power Consumption ...................................................................4 Current Consumption ................................................................4 Operational Environment .........................................................4 Default IP Address ......................................................................4 Standards ........................................................................................4 Interfaces ...............................................................................5 Tx LEDs and Rx LEDs .................................................................6 Reset Button ..................................................................................6 General Information on the RS485 Standard ...................7 Ethernet Interfaces and LEDs ................................................7 Connection to Buses ...................................................................8 Communication Baud Rates ...................................................8 Connection to Panel Buses ......................................................8 Connection to BACnet MSTP Bus .........................................9 Connection to Field Buses .......................................................9 Connection to Modbus RTU ....................................................9 Connection to CP-IO Bus ..........................................................9 Connection to M-Bus .................................................................10 Power Supply .........................................................................10 Transformers ..................................................................................10 Switch Power Supply ..................................................................11 Fusing ...............................................................................................11 Power Supply of Field Devices ................................................11 Wiring and Set-up ................................................................13 General Safety Considerations ...............................................13 Wiring Terminals ...........................................................................13 Connecting Power Supply .........................................................13 Earth Grounding ...........................................................................13 Cable Specifications ....................................................................14 Wireless Connectivity ..........................................................15 Connectivity Frequency Range ...............................................15 General Information ....................................................................15 Automatic Resetting Fuse ..................................................16 Connection Examples ..........................................................17 Ring LED .................................................................................34 Troubleshooting with LEDs ................................................35 Troubleshooting with LEDs of RS485 Interfaces 1, 2, 3 ............................................................35 Troubleshooting with the Ethernet Interface LEDs ...........................................................35 Dimensions 36 CPO-PC400-W/CPO-PC400-UW ..........................................36 Appendix: Earth Grounding ...............................................37 ComfortPoint Open and SELV .................................................37 ComfortPoint Open and EN60204-1 ...................................37 Functional EMC Grounding ......................................................37 Controller Part Numbers ....................................................38 Accessories Part Numbers ........................................................38 Technical Literature ............................................................39 CPO-PC400-W/CPO-PC400-UW HVAC CONTROLLER 3EN0B-0085 IE10 R0420 GENERAL SAFETY INFORMATION • When performing any work (installation, mounting, start-up), all manufacturer instructions and in particular the Installation and Commissioning Instructions (EN1B-0077IE10) are to be observed. • The ComfortPoint™ Open System (including the CPO- PC400-W/CPO-PC400-UW HVAC Controller, Panel Bus I/O modules, manual disconnect modules, and the auxiliary terminal packages) may be installed and mounted only by authorized and trained personnel. •Rules regarding electrostatic discharge should be followed. •If the ComfortPoint™ Open System is modified in any way, except by the manufacturer, all warranties concerning operation and safety are invalidated. •Make sure that the local standards and regulations are observed at all times. Examples of such regulations are VDE 0800 and VDE 0100 or EN 60204-1 for earth grounding. •Use only accessory equipment which comes from or has been approved by Honeywell. •It is recommended that devices be kept at room temperature for at least 24 hours before applying power. This is to allow any condensation resulting from low shipping/storage temperatures to evaporate. •The ComfortPoint™ Open System must be installed in a manner (e.g., in a lockable cabinet) ensuring that uncertified persons have no access to the terminals. •Investigated according to United States Standard UL- 60730-1,UL-916, and UL60730-2-9. •Investigated according to Canadian National Standard(s) C22.2, No. 205-M1983 (CNL-listed). •Do not open the CPO-PC400-W/CPO-PC400-UW, as it contains no user-serviceable parts i…

Text truncated - open the document above for the full version.

External Photos

Pic.1: Top View Pic.2: Bottom View Pic.3: Side View Pic.4: Side View Pic.5: Side View Pic.6: Side View

ID Label/Location Info

Label Location

Internal Photos

Pic 1. Internal of view Pic 2. Internal of view Pic 3. Base board Pic 4. Base board Pic 5. SOM board Pic 6. SOM board Pic 7. LED board & USB board Pic 8. LED board & USB board Pic 9. LED board & USB board Pic 10. LED board & USB board Pic 11. RF module

RF Exposure Info

Certificate Number: 5055.02 The State Radio_monitoring_center Testing Center (SRTC) CONTENTS 1 GENERAL INFORMATION 2 DESCRIPTION OF THE DEVICE UNDER TEST 3 REFERENCE SPECIFICATION 4 RESULT SUMMARY 5 TEST RESULTS The State Radio_monitoring_center Testing Center (SRTC) 1 GENERAL INFORMATION 1.1 Notes of the test report 1.2 Information about the testing laboratory 1.3 Applicant’s details 1.4 Manufacturer’s details The State Radio_monitoring_center Testing Center (SRTC) 2 DESCRIPTION OF THE DEVICE UNDER TEST 2.1 Final Equipment Build Status The State Radio_monitoring_center Testing Center (SRTC) The State Radio_monitoring_center Testing Center (SRTC) 11 7 The State Radio_monitoring_center Testing Center (SRTC) The State Radio_monitoring_center Testing Center (SRTC) 3 REFERENCE SPECIFICATION The State Radio_monitoring_center Testing Center (SRTC) 4 RESULT SUMMARY The State Radio_monitoring_center Testing Center (SRTC) 5 TEST RESULTS 5.1 Average Power Output Test Result The State Radio_monitoring_center Testing Center (SRTC) The State Radio_monitoring_center Testing Center (SRTC) The State Radio_monitoring_center Testing Center (SRTC) 5.2 Calculation result The State Radio_monitoring_center Testing Center (SRTC)

Test Report

Certificate Number: 5055.02 TEST REPORT FOR BLUETOOTH TESTING Report No.:SRTC2018-9004(F)-18102401(D) Product Name: HVAC Controller Product Model: CPO-PC400-UW Applicant: Honeywell (Beijing) Technology Solutions Lab Co., Ltd. Manufacturer: Honeywell (Beijing) Technology Solutions Lab Co., Ltd. Specification: FCC Part 15, Subpart C (2019) FCC ID: 2ARTN-00001 The State Radio_monitoring_center Testing Center (SRTC) 15th Building, No.30Shixing Street, Shijingshan District, Beijing, P.R.China Tel: 86-10-57996183 Fax: 86-10-57996388 No.: SRTC2018-9004(F)-18102401(D) FCC ID: 2ARTN-00001 The State Radio_monitoring_center Testing Center (SRTC) Page number:1 of 66 Tel: 86-10-5799 6183 Fax:86-10-57996388 V3.0.0 CONTENTS 1. GENERAL INFORMATION .................................................................................................................................... 2 1.1 NOTES OF THE TEST REPORT .................................................................................................................................... 2 1.2 INFORMATION ABOUT THE TESTING LABORATORY ..................................................................................................... 2 1.3 APPLICANT’S DETAILS ................................................................................................................................................ 2 1.4 MANUFACTURER’S DETAILS ....................................................................................................................................... 2 1.5 TEST ENVIRONMENT .................................................................................................................................................. 3 2 DESCRIPTION OF THE DEVICE UNDER TEST .................................................................................................. 4 2.1 FINAL EQUIPMENT BUILD STATUS ............................................................................................................................. 4 2.2D ESCRIPTION OF TEST MODES .................................................................................................................................. 5 2.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ................................................................................. 5 2.3 DUTY CYCLE OF TEST SIGNAL ................................................................................................................................... 7 2.4 EUT OPERATING CONDITIONS .................................................................................................................................... 7 2.5 SUPPORT EQUIPMENT................................................................................................................................................ 7 3 REFERENCE SPECIFICATION ............................................................................................................................. 7 4 KEY TO NOTES AND RESULT CODES ............................................................................................................... 7 5 RESULT SUMMARY ............................................................................................................................................... 8 6 TEST RESULT ......................................................................................................................................................... 9 6.1 20DB BANDWIDTH ...................................................................................................................................................... 9 6.2 CHANNEL SEPARATION ............................................................................................................................................ 10 6.3 PEAK TRANSMITTER OUTPUT POWER ..................................................................................................................... 11 6.4 DWELL TIME ............................................................................................................................................................. 12 6.5 NUMBER OF HOPPING FREQUENCIES...................................................................................................................... 13 6.6 CONDUCTED OUT OF BAND EMISSION MEASUREMENT ............................................................................................ 14 6.7 BAND-EDGE MEASUREMENT .................................................................................................................................... 15 6.8 SPURIOUS RADIATED EMISSIONS ............................................................................................................................ 16 6.9 AC POWER LINE CONDUCTED EMISSION ................................................................................................................ 21 7 MEASUREMENT UNCERTAINTIES ................................................................................................................... 23 8 TEST EQUIPMENTS ............................................................................................................................................. 24 APPENDIX A – TEST DATA OF CONDUCTED EMISSION ................................................................................ 25 APPENDIX B – TEST DATA OF RADIATED EMISSION ...................................................................................... 52 No.: SRTC2018-9004(F)-18102401(D) FCC ID: 2ARTN-00001 The State Radio_monitoring_center Testing Center (SRTC) Page number:2 of 66 Tel: 86-10-5799 6183 Fax:86-10-57996388 V3.0.0 1. GENERAL INFORMATION 1.1 Notes of the test report The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written permission of The State Radio_monitoring_center Testing Center (SRTC). The test results relate only to individual items of the samples which have been tested. The certification and a…

Text truncated - open the document above for the full version.

Test Setup Photos

No.: SRTC2018-9004(I)-18102401(D) IC ID: 24552-00001 The State Radio_monitoring_center Testing Center (SRTC) Page number: 1 of 2 Tel: 86-10-5799 6183 Fax: 86-10-57996388 V3.0.0 TEST SETUP RF Conducted Test setup Spurious Radiated Emissions Test setup (30MHz~1GHz) 0.8m No.: SRTC2018-9004(I)-18102401(D) IC ID: 24552-00001 The State Radio_monitoring_center Testing Center (SRTC) Page number: 2 of 2 Tel: 86-10-5799 6183 Fax: 86-10-57996388 V3.0.0 Spurious Radiated Emissions Test setup (above 1GHz) 1.5m Conducted Emissions Test Setup (with charger)

Contact Information

Applicant

wei guo(Senior Hardware Architecture)
[email protected]+86 10 56696675Fax: +86 10 57560504

Test Firm

The State Radio_monitoring_center Testing CenterSun Yang
[email protected]+86-10-57996131

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.58 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Honeywell (Beijing) Technology Solutions Labs Co.,Ltd.

2ARTN-00014

INNCOM BLE Module

Jan 21, 2026

Equipment Class

DTS - Digital Transmission System
2ARTN-00012

Thermostat

Jan 08, 2026

Equipment Class

FDS - Part 15 Field Disturbance Sensor
2ARTN-00013

Thermostat

Jan 08, 2026

Equipment Class

FDS - Part 15 Field Disturbance Sensor
2ARTN-00011

Thermostat

Sep 18, 2024

Equipment Class

DTS - Digital Transmission System
BACnet IP/MSTP VAV Controller - FCC ID 2ARTN-00006 - Honeywell (Beijing) Technology Solutions Labs Co.,Ltd.
2ARTN-00006

BACnet IP/MSTP VAV Controller

Jul 01, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX