Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 10, 2026
Application Purpose
Original Equipment
Equipment Note
VistaZ Power, VistaZ Go
Frequency Range
2402.00000000 - 2480.00000000
Company
Coolr Group Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗
↗

ID Label/Location Info

↗
↗

Internal Photos

↗
↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual V1.0 Rev0.06 PMN: VistaZ Power, VistaZ Go HVIN: CVP-0401, CVG-0401 Prepared by: Sandeep Maurya Release date: 17/03/2026 THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROPRIETARY OF COOLRGROUP AND IS CONFIDENTIAL. ANY PRODUCTION IN PART OR WHOLE WITHOUT PRIOR WRITTEN AUTHORIZATION OF COOLRGROUP IS PROHIBITED CoolR Group Inc | www.coolrgroup.com 1 | Page Contents 1. Pre-requisites 3 2. Steps to use or install VistaZ devices at client/user location: 3 3. FAQ 4 4. How to check CoolR mobile Application version? 5 5. How to login to CoolR mobile Application? 5 6. How to scan VistaZ Device? 5 7. How to check Vista device is connected/not connected? 10 8. How to check Firmware version? 12 9. How to check the battery voltage? 13 10. How to sync the device time? 14 11. How to capture Image manually? 15 12. How to download/view Image on mobile screen? 17 13. How to check events? 18 14. How to reboot the device? 20 15. How to Factory Reset? 21 16. How to upload the image on CoolR server over BLE? 23 17. How to enable Wi-Fi? 26 18. How to upload the image on portal over WIFI? 26 19. How to enable cellular mode? 27 20. How to upload the image on portal over Cellular? 28 21. How to set time slot for image capture? 28 22. How to enable door detection capability? 28 23. Device appearance and use case 29 24. FCC Warning: 30 25. IC Warning: 30 CoolR Group Inc | www.coolrgroup.com 2 | Page Note: This user manual applies to the following models: PMN: VistaZ Power, VistaZ Go | HVIN: CVP-0401, CVG-0401 1. Pre-requisites 1.1. VistaZ Power (CVP-0401) or VistaZ Go (CVG-0401). 1.2. Android Phone with internet connectivity*. 1.3. CoolR Mobile Application v3.9 1.4. CoolR App credentials Notes: 1. * iPhone can also be used for device operation but this manual focuses on Android phone. 2. CoolR Mobile app can be downloaded from https://drive.google.com/file/d/1N8yHpdhdj5RXXhk328SrgAiKVkVYaMuE/view?usp=sharing Please contact CoolR team if you are not able to download the apk from the link. 2. Steps to use or install VistaZ devices at client/user location: 1. Scan vistaZ device via CoolR mobile application. 2. Sync the device with mobile app. 3. Scan again. 4. Connect the Device with RN app. 5. As per client / user requirement enable wireless communication interface for Device: a. Wi-Fi mode. (Wi-Fi ID, password set, Wi-Fi on interval set etc) Or b. Cellular mode. (cellular APN, Band etc set) 6. As per client user requirement enable image-capture method. a. Manual image capture. b. Time slot-based image capture. c. Door based image capture. Note: 1. There are a lot of different features in device, which need to set when we install VistaZ device but above steps are basic settings which need to done to make device working. CoolR Group Inc | www.coolrgroup.com 3 | Page 3. FAQ 1. How to check CoolR mobile Application version? 2. How to login to CoolR RN mobile application? 3. How to scan VistaZ Device? 4. How to check VistaZ device is connected/not connected? 5. How to check Firmware version? 6. How to check the battery voltage? 7. How to sync the device time? 8. How to capture Image manually? 9. How to download/view Image on mobile screen? 10. How to check events? 11. How to reboot the device? 12. How to Factory Reset? 13. How to upload the image on portal over BLE? 14. How to enable Wi-Fi? 15. How to upload the image on portal over WIFI? 16. How to enable cellular mode? 17. How to upload the image on portal over Cellular? 18. How to set time slot for image capture? 19. How to enable door detection capability? 20. Other: a. How to Increase RN app disconnect time duration with the VistaZ device? b. How to search and connect multiple devices? c. How to set CoolR Server address in RN app? d. How to increase BLE ping interval? e. How to set Tx power of BLE? f. How to set APN, band, network mode (2G/LTE-CAT-M1/NB-IoT)? CoolR Group Inc | www.coolrgroup.com 4 | Page 4. How to check CoolR mobile Application version? 5. How to login to CoolR mobile Application? 6. How to scan VistaZ Device? Steps - 1. Make sure Android phone is connected with internet. 2. Click to open CoolR Mobile Application. 3. You can see the Application version CoolR Group Inc | www.coolrgroup.com 5 | Page 4. Click on LOGIN 5. Now enter the Login Id and password. (Note – please connect with CoolR team to get the Login credentials for the particular user) CoolR Group Inc | www.coolrgroup.com 6 | Page 6. After Successfully Login, Home screen will be visible, 7. Click on the Devices option. 8. Click on the Diagnostics/Configure. 9. Now Device Monitor screen will be visible. 10. Enter the last 5 digits of VistaZ seral No. in the search bar. You can get serial number from device serial number label on the device enclosure. CoolR Group Inc | www.coolrgroup.com 7 | Page 11. Click on 3 dots for start scan 12. Click on start scan. CoolR Group Inc | www.coolrgroup.com 8 | Page 13. Once device serial number is visible, Click on Sync before connection with VistaZ and wait until device is synced. CoolR Group Inc | www.coolrgroup.com 9 | Page 7. How to check Vista device is connected/not connected? Steps - 1. Click on Z icon to connect the device. 2. Once device is connected, a cross sign will be visible on the mid bottom of the screen. CoolR Group Inc | www.coolrgroup.com 10 | Page 3. Once the status screen is visible, we can connect to the device by clicking on the cross symbol at the bottom canter of the screen. CoolR Group Inc | www.coolrgroup.com 11 | Page 8. How to check Firmware version? Above is just example, based on actual firmware in your device it will show in the respective slot. CoolR Group Inc | www.coolrgroup.com 12 | Page 9. How to check the battery voltage? CoolR Group Inc | www.coolrgroup.com 13 | Page 10. How to sync the device time? Steps 1. Click on the circle pointed in the image, 2. Once time is synced, a pop-up will be visible on the screen to confirm the same. CoolR Group Inc | www.coolrgroup.com 14 | Page 11. How to capture Image manua…

Text truncated - open the document above for the full version.

Internal Photos

Appendix-CVP-0401-Photos Page 13 of 16 Model: CVG-0401 BT Antenna Appendix-CVP-0401-Photos Page 14 of 16 Appendix-CVP-0401-Photos Page 15 of 16 BT Antenna LTE Antenna Appendix-CVP-0401-Photos Page 16 of 16 ======End====== WiFi Antenna

Test Setup Photos

Appendix-CVP-0401-Photos Page 1 of 16 1. Test Setup photos Model CVP-0401 FCC ID: 2ARWCCVS-0401 1.1 Photograph – Conducted Emission For Conducted Emission Test Site 1# 1.2 Photograph – Radiated Emissions For 9kHz-30MHz Test Site 2# Appendix-CVP-0401-Photos Page 2 of 16 For 30MHz-1000MHz Test Site 2# For Above 1GHz Test Site 1#

Test Report

Approval sheet Page 1 of 9 ASC_RFANT3216120A5T_V09 Aug. 2018 RFANT Series – RoHS Compliance MULTILAYER CERAMIC ANTENNA Halogens Free Product 2.4 GHz ISM Band RF Application P/N: RFANT3216120A5T *Contents in this sheet are subject to change without prior notice. Approval sheet Page 2 of 9 ASC_RFANT3216120A5T_V09 Aug. 2018 FEATURES 1. Surface Mounted Devices with a small dimension of 3.2 X 1.6 X1.2 mm 3 meet future miniaturization trend. 2. LTCC process 3. High stability in Temperature / Humidity Change APPLICATIONS 1. 2.4GHz ISM band RF applications 2. Bluetooth, Wireless, HomeRF CONSTRUCTION DIMENSIONS Figure Symbol Dimension (mm) L 3.20 ± 0.20 W 1.60 ± 0.10 T 1.20 ± 0.10 A 0.25 ± 0.15 PINConnection 1 Feeding 2 Identification Mark 3 Soldering terminal Approval sheet Page 3 of 9 ASC_RFANT3216120A5T_V09 Aug. 2018 ELECTRICAL CHARACTERISTICS RFANT3216120A5T Specification Working Frequency Range 2450 ± 50 MHz Fc (GHz) 2.9 Gain (dBi) 2 (Typical) VSWR 2 max. Series 1 6.8nH Matching component value Series 2 - Power Capacity 3 W max. Maximum Input Power 5 Watts for 5 minutes Operation Temperature -40 ̊C ~ +85 ̊C Polarization Linear Azimuth Beamwidth Omni-directional * This frequency must be adjusted to 2.45GHz with matching circuit. SOLDER LAND PATTERN DESIGN Figure Approval sheet Page 4 of 9 ASC_RFANT3216120A5T_V09 Aug. 2018 Antenna on Test Board ( Thickness 1.2mm) Antenna S11 on Test Board Antenna VSWR on Test Board Approval sheet Page 5 of 9 ASC_RFANT3216120A5T_V09 Aug. 2018 RADIATION PATTERN Radiation Pattern and Gain were dependent on measurement board design. The specification of RFANT3216120A5T antenna was measured based on the PCB size and installation position as shown in the below figure Test Board Vertical Horizontal Y - Z Plane Average Gain= 0.948 dBi X Cut -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 Peak Gain = 2.93dBi Average Gain = 0.60dBi X Cut -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 Peak Gain= -5.60dBi Average Gain=-10.19dBi X - Z Plane Average Gain= -2.147 dBi X Cut -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 127.0 Peak Gain= -4.98 dBi Average Gain= -9.68dBi X Cut -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 Peak Gain= 1.61 dBi Average Gain= -2.99 dBi X - Y Plane Average Gain= -2.810 dBi X Cut -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 Peak Gain= -3.79 dBi Average Gain= -8.89dBi X Cut -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 Peak Gain= 0.77 dBi Average Gain= -4.04 dBi x Y Z x Y x Y Z X Z X Z Y Z Y Approval sheet Page 6 of 9 ASC_RFANT3216120A5T_V09 Aug. 2018 RELIABILITY TEST Test item Test condition / Test method Specification Solderability JIS C 0050-4.6 JESD22-B102D *Solder bath temperature:235  5C *Immersion time:2  0.5 sec Solder:Sn3Ag0.5Cu for lead-free At least 95% of a surface of each terminal electrode must be covered by fresh solder. Leaching (Resistance to dissolution of metallization) IEC 60068-2-58 *Solder bath temperature:260  5C *Leaching immersion time:30  0.5 sec Solder : SN63A Loss of metallization on the edges of each electrode shall not exceed 25%. Resistance to soldering heat JIS C 0050-5.4 *Preheating temperature:120~150°C, 1 minute. *Solder temperature:2705C *Immersion time:101 sec Solder:Sn3Ag0.5Cu for lead-free Measurement to be made after keeping at room temperature for 242 hrs No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Loss of metallization on the edges of each electrode shall not exceed 25%. Drop Test JIS C 0044 Customer’s specification. *Height:75 cm *Test Surface:Rigid surface of concrete or steel. *Times:6 surfaces for each units;2 times for each side. No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Vibration JIS C 0040 *Frequency:10Hz~55Hz~10Hz(1min) *Total amplitude:1.5mm *Test times:6hrs.(Two hrs each in three mutually perpendicular directions) No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Adhesive Strength of Termination JIS C 0051- 7.4.3 *Pressurizing force: 5N(≦0603);10N(>0603) *Test time:10±1 sec No remarkable damage or removal of the termination. Bending test JIS C 0051- 7.4.1 The middle part of substrate shall be pressurized by means of the pressurizing rod at a rate of about 1 mm/s per second until the deflection becomes 1mm/s and then pressure shall be maintained for 51 sec. Measurement to be made after keeping at room temperature for 242 hours No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Approval sheet Page 7 of 9 ASC_RFANT3216120A5T_V09 Aug. 2018 Temperature cycle JIS C 0025 1. 303 minutes at -40C3C, 2. 10~15 minutes at room temperature, 3. 303 minutes at +85C3C, 4. 10~15 minutes at room temperature, Total 100 continuous cycles Measurement to be made after keeping at room temperature for 242 hrs No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. High temperature JIS C 0021 *Temperature:85C2C *Test duration:1000+24/-0 hours Measurement to be made after keeping at room temperature for 242 hrs No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Humidity (steady conditions) JIS C 0022 *Humidity:90% to 95% R.H. *Temperature:402C *Time:1000+24/-0 hrs. Measurement to be made after keeping at room temperature for 242 hrs ※ 500hrs measuring the first data then 1000hrs data No mechanical damage. Electrical spe…

Text truncated - open the document above for the full version.

Test Report

Description: 2012 2.4GHz Chip Antenna PART NUMBER: ANT2012LL00R2400A In the effort to improve our products, we reserve the right to make changes judged to be necessary. CONFIDENTIAL AND PROPRIETARY INFORMATION This document contains confidential and proprietary information of Pulse Electronics, Inc. (Pulse) and is protected by copyright, trade secret and other state and federal laws. Its receipt or possession does not convey any rights to reproduce, disclose its contents, or to manufacture, use or sell anything it may describe. Reproduction, disclosure or use without specific written authorization of Pulse is strictly forbidden. For more information: Pulse Worldwide Headquarters Pulse/Larsen Antennas Europe Headquarters Pulse (Suzhou) Wireless Products Co, Inc. 15255 Innovation Drive #100 Pulse GmbH & Do, KG 99 Huo Ju Road(#29 Bldg,4 th Phase San Diego, CA 92128 Vancouver, WA 98683 Zeppelinstrasse 15 Suzhou New District USA USA Herrenberg, Germany Jiangsu Province, Suzhou 215009 PR China Tel:1-858-674-8100 Tel: 1-360-944-7551 - Tel: 49 7032 7806 0 Tel: 86 512 6807 9998 18110 SE 34 th St Bldg 2 Suite 250 Features: Applications: •Size : 2.0x1.2x1.1 mm •Working Frequency : 2.4~2.5GHz •Omni-directional Radiation •Tape & reel automatic mounting •Reflow process compatible •RoHS compliant •2.4GHz WiFi device •Bluetooth gadget •Zigbee device •ISM band equipment 1 In the effort to improve our products, we reserve the right to make changes judged to be necessary. CONFIDENTIAL AND PROPRIETARY INFORMATION This document contains confidential and proprietary information of Pulse Electronics, Inc. (Pulse) and is protected by copyright, trade secret and other state and federal laws. Its receipt or possession does not convey any rights to reproduce, disclose its contents, or to manufacture, use or sell anything it may describe. Reproduction, disclosure or use without specific written authorization of Pulse is strictly forbidden. Description: 2012 2.4GHz Chip Antenna PART NUMBER: ANT2012LL00R2400A 2 ELECTRICAL SPECIFICATIONS MECHANICAL DRAWING Working Frequency 2.45 GHz Bandwidth 370 MHz(Typ.) Return Loss 10.0 dB Min Polarization Linear Azimuth Beamwidth Omni-directional Peak Gain 3.77 dBi(Typ.) Impedance 50 Ω Operating Temperature - 40~105 °C Maximum Power 1 W Termination Ni / Sn (Environmentally-Friendly Leadless) Resistance to Soldering Heats 260 °C , 10sec. NOTE 1. The specification is defined on Pulse evaluation board Dimension L (mm) 2.00 ± 0.20 W (mm) 1.25 ± 0.20 T (mm) 1.10 ± 0.10 A (mm) 0.15 ± 0.10 Terminal name Function S1 Feeding Point S2 Soldering Point In the effort to improve our products, we reserve the right to make changes judged to be necessary. CONFIDENTIAL AND PROPRIETARY INFORMATION This document contains confidential and proprietary information of Pulse Electronics, Inc. (Pulse) and is protected by copyright, trade secret and other state and federal laws. Its receipt or possession does not convey any rights to reproduce, disclose its contents, or to manufacture, use or sell anything it may describe. Reproduction, disclosure or use without specific written authorization of Pulse is strictly forbidden. Description: 2012 2.4GHz Chip Antenna PART NUMBER: ANT2012LL00R2400A 3 REFERENCE DESIGN OF EVALUATION BOARD Outlook and dimension of evaluation board Details of soldering Pad In the effort to improve our products, we reserve the right to make changes judged to be necessary. CONFIDENTIAL AND PROPRIETARY INFORMATION This document contains confidential and proprietary information of Pulse Electronics, Inc. (Pulse) and is protected by copyright, trade secret and other state and federal laws. Its receipt or possession does not convey any rights to reproduce, disclose its contents, or to manufacture, use or sell anything it may describe. Reproduction, disclosure or use without specific written authorization of Pulse is strictly forbidden. Description: 2012 2.4GHz Chip Antenna PART NUMBER: ANT2012LL00R2400A 4 ELECTRICAL PERFORMANCES Return loss Radiation pattern Frequency = 2.45 GHz Max gain = 3.77 dBi, at (90,240) MEG (mean effective gain)= -193 dBi Directivity (dB) = 4.61 Efficiency = -0.84 dB, 82.93 % Marker data 1. 2.21GHz, -10dB 2. 2.45GHz, -28.5dB 3. 2.58GHz, -10dB In the effort to improve our products, we reserve the right to make changes judged to be necessary. CONFIDENTIAL AND PROPRIETARY INFORMATION This document contains confidential and proprietary information of Pulse Electronics, Inc. (Pulse) and is protected by copyright, trade secret and other state and federal laws. Its receipt or possession does not convey any rights to reproduce, disclose its contents, or to manufacture, use or sell anything it may describe. Reproduction, disclosure or use without specific written authorization of Pulse is strictly forbidden. Description: 2012 2.4GHz Chip Antenna PART NUMBER: ANT2012LL00R2400A 5 REVISION HISTORY Revision Date Description Version 1 Oct. 13, 2020 - New issue

Test Report

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Page 1 of 69 TEST REPORT Referen ce No. .................... : WTU26D02040331W003 FCC ID ................................ : 2ARWCCVS-0401 Applicant ............................ : Coolr Group Inc Address .............................. : 4451 Brookfield Corporate Dr. Suite 111, Chantilly, VA 20151, USA Manufacturer .................... : MIOT Wireless Solutions Co., Ltd. Address .............................. : Room 602, Building No.14, InnoWing Valley, No.135 Zhangji Road, Kunshan, Suzhou, Jiangsu, China. Product ............................... : VistaZ PMN .................................... : VistaZ Power, VistaZ Go Model(s). ............................ : CVP-0401, CVG-0401 Standards........................... : FCC 47CFR Part 15.247 Date of Receipt Sample .... : 2026-02-26 Date of Test ....................... : 2026-03-04 to 2026-03-24 Date of Issue ...................... : 2026-03-30 Test Result ......................... : Pass Remarks: The re sults shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China Tel: +86-769-2267 6998 Fax: +86-769-2267 6828 Compiled by: Approved by: Frank Yin / Project Engineer Deval Qin / Designated Reviewer Reference No.: WTU26D02040331W003 Page 2 of 69 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 2 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 CONTENTS ............................................................................................................................................... 2 3 REVISION HISTORY ................................................................................................................................. 4 4 GENERAL INFORMATION ....................................................................................................................... 5 4.1 GENERAL DESCRIPTION OF E.U.T. ....................................................................................................... 5 4.2 DETAILS OF E.U.T. .............................................................................................................................. 5 4.3 CHANNEL LIST ..................................................................................................................................... 5 4.4 TEST FACILITY .................................................................................................................................... 6 4.5 SUBCONTRACTED ................................................................................................................................ 6 4.6 ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................... 6 4.7 TEST MODE ........................................................................................................................................ 7 5 TEST SUMMARY ...................................................................................................................................... 8 6 EQUIPMENT USED DURING TEST ......................................................................................................... 9 6.1 EQUIPMENTS LIST ............................................................................................................................... 9 6.2 DESCRIPTION OF SUPPORT UNITS ...................................................................................................... 10 6.3 MEASUREMENT UNCERTAINTY ........................................................................................................... 10 6.4 TEST EQUIPMENT CALIBRATION ......................................................................................................... 10 7 DUTY CYCLE .......................................................................................................................................... 11 8 CONDUCTED EMISSION ....................................................................................................................... 13 8.1 E.U.T. OPERATION ............................................................................................................................ 13 8.2 EUT SETUP ...................................................................................................................................... 13 8.3 MEASUREMENT DESCRIPTION ............................................................................................................ 13 8.4 CONDUCTED EMISSION TEST RESULT ................................................................................................ 14 9 RADIATED EMISSIONS ......................................................................................................................... 16 9.1 EUT OPERATION ............................................................................................................................... 16 9.2 TEST SETUP ..................................................................................................................................... 17 9.3 SPECTRUM ANALYZER SETUP ............................................................................................................ 18 9.4 TEST PROCEDURE ............................................................................................................................. 19 9.5 CORRECTED AMPLITUDE & MARGIN CALCULATION .............................................................................. 19 9.6 SUMMARY OF TEST RESULTS .................................................…

Text truncated - open the document above for the full version.

Test Report

Reference No.: WTU26D02040331W002 Page 26 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Radiated Restricted Band Emission Low-2402: Antenna Polarization: Horizontal Reference No.: WTU26D02040331W002 Page 27 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Antenna Polarization: Vertical Reference No.: WTU26D02040331W002 Page 28 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn High-2480: Antenna Polarization: Horizontal Reference No.: WTU26D02040331W002 Page 29 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Antenna Polarization: Vertical Test Frequency: 18GHz~25GHz The measurements were more than 20 dB below the limit and not reported. Reference No.: WTU26D02040331W002 Page 30 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 9 Conducted Spurious Emissions Test Requirement: FCC CFR47 Part 15 Section 15.247 Test Method: KDB 558074 D01 15.247 Meas Guidance v05r02 April 2, 2019; ANSI C63.10-2020 Test Result: PASS Limit: In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in Section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), must also comply with the radiated emission limits specified in Section 15.209(a) (see Section 15.205(c)). 9.1 Test Procedure 1. Remove the antenna from the EUT and then connect a low RF cable from the antenna port to the spectrum; 2. Set the spectrum analyzer: Blow 30MHz: RBW = 100kHz, VBW = 300kHz, Sweep = auto Detector function = peak, Trace = max hold Above 30MHz: RBW = 100kHz, VBW = 300kHz, Sweep = auto Detector function = peak, Trace = max hold Reference No.: WTU26D02040331W002 Page 31 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 9.2 Test Result GFSK (LE 1M)_channel 0 Ref 9kHz-150kHz 150kHz-10MHz 10MHz-30MHz Reference No.: WTU26D02040331W002 Page 32 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 30MHz-25GHz Reference No.: WTU26D02040331W002 Page 33 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn GFSK (LE 1M)_channel 19 Ref 9kHz-150kHz 150kHz-10MHz 10MHz-30MHz Reference No.: WTU26D02040331W002 Page 34 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 30MHz-25GHz Reference No.: WTU26D02040331W002 Page 35 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn GFSK (LE 1M)_channel 39 Ref 9kHz-150kHz 150kHz-10MHz 10MHz-30MHz Reference No.: WTU26D02040331W002 Page 36 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 30MHz-25GHz Reference No.: WTU26D02040331W002 Page 37 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn GFSK (LE 2M)_channel 0 Ref 9kHz-150kHz 150kHz-10MHz 10MHz-30MHz Reference No.: WTU26D02040331W002 Page 38 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 30MHz-25GHz Reference No.: WTU26D02040331W002 Page 39 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn GFSK (LE 2M)_channel 19 Ref 9kHz-150kHz 150kHz-10MHz 10MHz-30MHz Reference No.: WTU26D02040331W002 Page 40 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 30MHz-25GHz Reference No.: WTU26D02040331W002 Page 41 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn GFSK (LE 2M)_channel 19 Ref 9kHz-150kHz 150kHz-10MHz 10MHz-30MHz Reference No.: WTU26D02040331W002 Page 42 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 30MHz-25GHz Reference No.: WTU26D02040331W002 Page 43 of 55 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 10 Band Edge Measurement Test Requirement: FCC 47CFR Part 15 Section 15.247 Test Method: KDB 558074 D01 15.247 Meas Guidance v05r02, April 2, 2019 Test Limit: Regulation 15.247 (d), in any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)). Test Mode: Transmitting 10.1 Test Produce 1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal from an external generator. 2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured frequency within its operating range, and make sure the instrument is operated in its linear range. 3. Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span including 100 kHz bandwidth from band edge. 4. Meas…

Text truncated - open the document above for the full version.

Test Report

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Page 1 of 55 TEST REPORT Referen ce No. .................... : WTU26D02040331W002 FCC ID ................................ : 2ARWCCVS-0401 Applicant ............................ : Coolr Group Inc Address .............................. : 4451 Brookfield Corporate Dr. Suite 111, Chantilly, VA 20151, USA Manufacturer ..................... : MIOT Wireless Solutions Co., Ltd. Address .............................. : Room 602…

Text truncated - open the document above for the full version.

Contact Information

Applicant

DURLABH JAIN
[email protected]Fax: 3478860538

Test Firm

WALTEK TESTING GROUP CO., LTD.Joy Zhou
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.60 mW
215C2.41 GHz - 2.46 GHz14.30 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The device supports 20MHz bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.