FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shanghai Teraoka Electronic Co., Ltd/
  3. 2ARYWWB-20

2ARYWWB-20SMART CARD TERMINAL

Shanghai Teraoka Electronic Co., Ltd
SMART CARD TERMINAL - FCC ID 2ARYWWB-20 - Shanghai Teraoka Electronic Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 02, 2021
Application Purpose
Original Equipment
Date of Application
Jul 26, 2021
Equipment Note
SMART CARD TERMINAL
Frequency Range
2412.00000000 - 2462.00000000
Company
Shanghai Teraoka Electronic Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CONFIDENTIAL PE Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 1 of 12 WB-20 SMART WIFI MODULE Operation Manual Rev. Description Date 1.0 Preliminary release 2019/12/13 1.1 Define model name 2020/2/6 CONFIDENTIAL PE Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 2 of 12 Notice This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this product does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. FCC RF Safety Caution statement: To satisfy FCC RF exposure requirements for mobile and base station transmission devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during operation. To ensure compliance, operation at closer than this transmitter must not recommended. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The device has been evaluated to meet general RF exposure requirement. CONFIDENTIAL PE Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 3 of 12 Contents 1. General Layout .................................................................................................................. 4 2. Features .............................................................................................................................. 5 3. Operating Conditions ........................................................................................................ 5 4. Connectors ......................................................................................................................... 5 5. Network Setup ................................................................................................................... 5 CONFIDENTIAL PE Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 4 of 12 1. General Layout Bridge Mode In this mode, module connects AP with WIFI and emission WIFI itself, the ETH port is LAN,PC and other device could connect module with Ethernet cable CONFIDENTIAL PE Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 5 of 12 2. Features • Onboard A64 Quad-core ARM Cortex-A53 1.2GHz (Fanless) • 1G DDR3L co-layout memory • 8G co-layout eMMC NAND flash • WIFI 2.4G/5G 802.11a/b/g/n/ac • Bluetooth 4.2 • TF CARD • OS: Android 6.0 3. Operating Conditions • Power Source : DC5V/0.15A • Operating Temperature : 0 ~ +50°C • Operating Humidity : 15 ~ 85% RH • Power Consumption : 0.75W 4. Connectors • DC 5V input connector (Pin head) • 1x RS-232C interface (Pin head) • 2x USB2.0 interface (One is pin head, the other is Mirco-USB) • 2x LAN interface (One is pin head, the other is RJ45) • 1x TF card socket 5. Network Setup 5.1 Link with Wired Cable Only Set as normal scale 1. Set SPEC135=xxx (xxx is the last 3 digits of Lan IP) 2. Set SPEC50=1 (usually act as server) SPEC50=0 (only for cloud) 3. Set Rezero+0416=LAN IP 4. Set Rezero+0418=LAN Subnet Mask 5. Set Rezero+0421=LAN Gateway if necessary 6. Make sure in Rezero+0457, WIFI switch= Inhibit First Line screen Second Line Screen Remark S0.1 AMS HOST 0 Host name which could by found by other device in LAN like computer name S0.2 AMS STATIC SELECT ETHERNET TYPE Please always use X key to set it as STATIC S0.3 AMS 000000000000 ENTER ETHERNET DNS1 Reserved S0.4 AMS 000000000000 ENTER ETHERNET DNS2 Reserved S0.5 AMS INHIBIT SELECT WIFI SWITCH Use X key to set it to ALLOW 5.2 Link with Wireless Only 5.2.1 Method 1: Set on Scale side Set Rezero+0457 as below First Line screen Second Line Screen Remark S0.1 AMS HOST 0 Host name which could by found by other device in LAN like computer name S0.2 AMS STATIC SELECT ETHERNET TYPE Please always use X key to set it as STATIC S0.3 AMS 000000000000 ENTER ETHERNET DNS1 Reserved S0.4 AMS 000000000000 ENTER ETHERNET DNS2 Reserved S0.5 AMS ALLOW SELECT WIFI SWITCH Use X key to set it to ALLOW S0.6 AMS SSID 0 Input SSID (Specail symbol can be set by ASCII) P32 key to swtich between local or ASCII S0.7 AMS NO SELECT WIFI ENCRYPTION NO/WEP/WPA-PSK S0.8 CH-01 PWD 0 Enter password of WIFI CONFIDENTIAL PE Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 6 of 12 S0.9 AMS STATIC SELECT WIFI TYPE Please always use X key to set it as STATIC S0.10 AMS 000000000000 ENTER WIFI IP1 Set WIFI IP address S0.11 AMS 000000000000 ENTER WIFI SUBNET MASK1 Set WIFI subnet mask S0.12 AMS 000000000000 ENTER WIFI DNS1 Set DNS if needed S0.13 AMS 000000000000 ENTER WIFI IP2 Set only if customer use dual network segment S0.14 AMS 000000000000 ENTER WIFI SUBNET MASK2 S0.15 AMS 000000000000 ENTER WIFI DNS2 S0.16 AMS 000000000000 ENTER WIFI GATEWAY Set WIFI gateway S0.17 AMS ALLOW SELECT AM FTP SWITCH Please always use X key to set it as Allow S0.18 AMS 300…

Text truncated - open the document above for the full version.

External Photos

FIGURE 1 SMART CARD TERMINAL (M/N: WB-20) T OP VIEW F IGURE 2 SMART CARD TERMINAL (M/N: WB-20) BUTTOM VIEW FIGURE 3 SMART CARD TERMINAL (M/N: WB-20) F RONT VIEW F IGURE 4 SMART CARD TERMINAL (M/N: WB-20) BACK VIEW FIGURE 5 SMART CARD TERMINAL (M/N: WB-20) L EFT VIEW F IGURE 6 SMART CARD TERMINAL (M/N: WB-20) RIGHT VIEW

ID Label/Location Info

Label Location: Label spec.: Label Location

RF Exposure Info

Applicant: Shanghai Teraoka Electronic Co., Ltd. Product Name: SMART CARD TERMINAL Model Number: WB‐20 FCC ID: 2ARYWWB‐20 RADIO FRREQUENCY EXPOSURE COMPLIANCE RESULT: Test Standard: FCC CFR 47 §1.1310 : Radiofrequency radiation exposure limits. Note: (1) Occupational/controlled exposure limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when a person is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. (2) General population/uncontrolled exposure limits apply in situations in which the general public may be exposed, or in which persons who are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. MPE Calculation Standard: MPEሺSሻ ൌ PG/ሺ4휋푅 ଶ ) where: S = power density (in appropriate units, e.g. mW/ cm 2 ) P = power input to the antenna (in appropriate units, e.g., mW) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) Calculation Result: For this EUT, General population/uncontrolled exposure limits applied. The limit value 1.0mW/cm 2 is available for this EUT. Modulation Peak Output Power Antenna Gain MPE Limit (dBm) (mW) (dBi) (Numeric) (mW/cm 2 ) (mW/cm 2 ) BLE 5.559 3.59667 5 3.16228 0.00226 1.0 BT(BR/EDR) 6.327 4.2924 5 3.16228 0.0027 1.0 Wifi‐2.4G 21.01 126.183 5 3.16228 0.07938 1.0 Wifi‐5G 11.75 14.9624 5 3.16228 0.00941 1.0 For R = 20cm

Test Report

Shanghai Teraoka Electronic Co., Ltd. FCC ID: 2ARYWWB-20 Page 1 of 46 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F21108 Prepared For: Shanghai Teraoka Electronic Co., Ltd. Tinglin Industry Development Zone, Jinshan District, Shanghai, China Prepared By: Audix Technology (Shanghai) Co., Ltd. 3F and 4F, 34Bldg, 680 Guiping Rd., Caohejing Hi-Tech Park, Shanghai 200233, China Tel: +86-21-64955500 File No. : C1D2011005 Report No. : ACI-F21108 Date of Test : 2020.11.11-2021.04.20 Date of Report : 2021.05.26 TEST REPORT On behalf of Shanghai Teraoka Electronic Co., Ltd. Product Name: SMART CARD TERMINAL Model No.: WB-20 FCC ID: 2ARYWWB-20 The statement is based on a single evaluation of one sample of the above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab logo. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. TESTING NVLAP LAB CODE 200371-0 Shanghai Teraoka Electronic Co., Ltd. FCC ID: 2ARYWWB-20 Page 2 of 46 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F21108 TABLE OF CONTENTS Page 1 SUMMARY OF STANDARDS AND RESULTS .......................................................................... 5 1.1 Description of Standards and Results ......................................................................................... 5 2 GENERAL INFORMATION .......................................................................................................... 6 2.1 Description of Equipment Under Test ........................................................................................ 6 2.2 EUT Specifications Assessed in Current Report ........................................................................ 7 2.3 Test Information ......................................................................................................................... 7 2.4 Sample Description .................................................................................................................... 7 2.5 Supported equipment .................................................................................................................. 8 2.6 Description of Test Facility ........................................................................................................ 8 3 CONDUCTED EMISSION TEST .................................................................................................. 9 3.1 Test Equipment ........................................................................................................................... 9 3.2 Block Diagram of Test Setup ..................................................................................................... 9 3.3 Conducted Emission Limits (§15.207) ..................................................................................... 10 3.4 Test Configuration .................................................................................................................... 10 3.5 Operating Condition of EUT .................................................................................................... 10 3.6 Test Procedures ........................................................................................................................ 10 3.7 Test Results .............................................................................................................................. 11 4 RADIATED EMISSION TEST ..................................................................................................... 13 4.1 Test Equipment ......................................................................................................................... 13 4.2 Block Diagram of Test Setup ................................................................................................... 13 4.3 Radiated Emission Limit (§15.209) ......................................................................................... 14 4.4 Test Configuration .................................................................................................................... 14 4.5 Operating Condition of EUT .................................................................................................... 15 4.6 Test Procedures ........................................................................................................................ 15 4.7 Test Results .............................................................................................................................. 16 5 6 DB BANDWIDTH MEASUREMENT ...................................................................................... 21 5.1 Test Equipment ......................................................................................................................... 21 5.2 Block Diagram of Test Setup ................................................................................................... 21 5.3 Specification Limits (§15.247(a)(2)) ........................................................................................ 21 5.4 Operating Condition of EUT .................................................................................................... 21 5.5 Test Procedure .......................................................................................................................... 21 5.6 Test Results .............................................................................................................................. 22 6 MAXIMUM PEAK OUTPUT POWER MEASUREMENT ...................................................... 25 6.1 Test Equipment ......................................................................................................................... 25 6.2 Block Diagram of Test Setup .................................................................................................. . 25 6.3 Specification Limits ((§15.247(b)(3)) ...............…

Text truncated - open the document above for the full version.

Test Report

Shanghai Teraoka Electronic Co., Ltd. FCC ID: 2ARYWWB-20 Page 1 of 15 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F21123 Prepared For: Shanghai Teraoka Electronic Co., Ltd. Tinglin Industry Development Zone, Jinshan District, Shanghai, China Prepared By: Audix Technology (Shanghai) Co., Ltd. 3F and 4F, 34Bldg, 680 Guiping Rd., Caohejing Hi-Tech Park, Shanghai 200233, China Tel: +86-21-64955500 File No. : C1D2011005 Report No. : ACI-F21123 Date of Test : 2021.01.17 Date of Report : 2021.05.25 TEST REPORT On behalf of Shanghai Teraoka Electronic Co., Ltd. Product Name: SMART CARD TERMINAL Model No.: WB-20 FCC ID: 2ARYWWB-20 The statement is based on a single evaluation of one sample of the above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab logo. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. TESTING NVLAP LAB CODE 200371-0 Shanghai Teraoka Electronic Co., Ltd. FCC ID: 2ARYWWB-20 Page 2 of 15 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F21123 TABLE OF CONTENTS Page 1 SUMMARY OF STANDARDS AND RESULTS .......................................................................... 4 1.1 Description of Standards and Results ......................................................................................... 4 2 GENERAL INFORMATION .......................................................................................................... 5 2.1 Description of Equipment Under Test ........................................................................................ 5 2.2 Test Information ......................................................................................................................... 6 2.3 Sample Description .................................................................................................................... 6 2.4 Supported equipment .................................................................................................................. 6 2.5 Description of Test Facility ........................................................................................................ 6 3 DFS MEASUREMENT .................................................................................................................... 7 3.1 Test Equipment ........................................................................................................................... 7 3.2 Block Diagram of Test Setup ..................................................................................................... 7 3.3 Specification Limits ................................................................................................................... 7 3.4 Operating Condition of EUT ...................................................................................................... 9 3.5 Test Procedure ............................................................................................................................ 9 3.6 Threshold Level .......................................................................................................................... 9 3.7 Test Results .............................................................................................................................. 10 4 DEVIATION TO TEST SPECIFICATIONS .............................................................................. 14 5 MEASUREMENT UNCERTAINTY LIST ................................................................................. 15 Shanghai Teraoka Electronic Co., Ltd. FCC ID: 2ARYWWB-20 Page 3 of 15 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F21123 JAREY LU / Supervisor BYRON WU / Deputy Assistant Manager BYRON KWO/Assistant General Manager TEST REPORT Applicant : Shanghai Teraoka Electronic Co., Ltd. EUT Description : SMART CARD TERMINAL (A) Model No. : Refer to Sec.2.1 (B) Power Supply : DC5V (C) Test Voltage : DC5V (Via Adaptor) Test Procedure Used: FCC RULES AND REGULATIONS PART 15 SUBPART E AND ANSI C63.10-2013 The device described above is tested by Audix Technology (Shanghai) Co., Ltd. to determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC Part 15 Subpart E limits. The test results are contained in this test report and Audix Technology (Shanghai) Co., Ltd. is assumed full responsibility for the accuracy and completeness of these measurements. This report also shows that the EUT (M/N: Refer to Sec2.1), which was tested is technically compliance with the FCC limits. This report applies to above tested Sample only. This report shall not be reproduced in part without written approval of Audix Technology (Shanghai) Co., Ltd. The test results for EUT's BLE/ WIFI (2.4G)/BT / WIFI (5G) function are contained in No.ACI-F21108, ACI-F21109, ACI-F21121, ACI-F21122 report. Date of Test : 2021.01.17 Date of Report : 2021.06.04 Producer : Reviewer : Signatory : Shanghai Teraoka Electronic Co., Ltd. FCC ID: 2ARYWWB-20 Page 4 of 15 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F21123 1 SUMMARY OF STANDARDS AND RESULTS 1.1 Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below: Description / Test Item Test Standard Results Meets Limit EMISSION Transmit Power Control (TPC) FCC RULES AND REGULATIONS PART 15 SUBPART E AND ANSI C63.10:2013 N/A 15.247(h)(1) DFS Non-Occupancy Period FCC RULES AND REGULATIONS PART 15 SUBPART E AND ANSI C63.10:2013 N/A 15.247(h)(2) DFS Detection Threshold N/A Channel Availability Check Time N/A U-NII Detection Bandwidth N/A DFS Detection Threshold N/A Channel Closing Transmission Time Pass Channel Move Time Pass U-NII Detection Bandwidth N/A N/A is an abbreviation for Not Applicable. Shanghai Teraoka Electronic Co., Ltd. FCC ID: 2ARYWWB-20 Page 5 of 15 Audix Technology (Shanghai) Co., Ltd. Report No.…

Text truncated - open the document above for the full version.

Test Report

Shanghai Teraoka Electronic Co., Ltd. FCC ID: 2ARYWWB-20 Page 1 of 72 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F21109 Prepared For: Shanghai Teraoka Electronic Co., Ltd. Tinglin Industry Development Zone, Jinshan District, Shanghai, China Prepared By: Audix Technology (Shanghai) Co., Ltd. 3F and 4F, 34Bldg, 680 Guiping Rd., Caohejing Hi-Tech Park, Shanghai 200233, China Tel: +86-21-64955500 File No. : C1D2011005 Report No. : ACI-F21109 Date of Test : 2020.11.11-2021.04.20 Date of Report : 2021.05.26 TEST REPORT On behalf of Shanghai Teraoka Electronic Co., Ltd. Product Name: SMART CARD TERMINAL Model No.: WB-20 FCC ID: 2ARYWWB-20 The statement is based on a single evaluation of one sample of the above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab logo. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. TESTING NVLAP LAB CODE 200371-0 Shanghai Teraoka Electronic Co., Ltd. FCC ID: 2ARYWWB-20 Page 2 of 72 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F21109 TABLE OF CONTENTS Page 1 SUMMARY OF STANDARDS AND RESULTS .......................................................................... 5 1.1 Description of Standards and Results ......................................................................................... 5 2 GENERAL INFORMATION .......................................................................................................... 6 2.1 Description of Equipment Under Test ........................................................................................ 6 2.2 EUT Specifications Assessed in Current Report ........................................................................ 7 2.3 Test Information ......................................................................................................................... 7 2.4 Sample Description .................................................................................................................... 7 2.5 Supported equipment .................................................................................................................. 8 2.6 Description of Test Facility ........................................................................................................ 8 3 CONDUCTED EMISSION TEST .................................................................................................. 9 3.1 Test Equipment ........................................................................................................................... 9 3.2 Block Diagram of Test Setup ..................................................................................................... 9 3.3 Conducted Emission Limits (§15.207) ..................................................................................... 10 3.4 Test Configuration .................................................................................................................... 10 3.5 Operating Condition of EUT .................................................................................................... 10 3.6 Test Procedures ........................................................................................................................ 10 3.7 Test Results .............................................................................................................................. 11 4 RADIATED EMISSION TEST ..................................................................................................... 13 4.1 Test Equipment ......................................................................................................................... 13 4.2 Block Diagram of Test Setup ................................................................................................... 13 4.3 Radiated Emission Limit (§15.209) ......................................................................................... 14 4.4 Test Configuration .................................................................................................................... 14 4.5 Operating Condition of EUT .................................................................................................... 15 4.6 Test Procedures ........................................................................................................................ 15 4.7 Test Results .............................................................................................................................. 16 5 6 DB BANDWIDTH MEASUREMENT ...................................................................................... 24 5.1 Test Equipment ......................................................................................................................... 24 5.2 Block Diagram of Test Setup ................................................................................................... 24 5.3 Specification Limits (§15.247(a)(2)) ........................................................................................ 24 5.4 Operating Condition of EUT .................................................................................................... 24 5.5 Test Procedure .......................................................................................................................... 24 5.6 Test Results .............................................................................................................................. 25 6 MAXIMUM PEAK OUTPUT POWER MEASUREMENT ...................................................... 31 6.1 Test Equipment ......................................................................................................................... 31 6.2 Block Diagram of Test Setup .................................................................................................. . 31 6.3 Specification Limits ((§15.247(b)(3)) ...............…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Set-Up Photos 1. Conducted Test 2. Radiated Test (B ELOW 1GHZ) (ABOVE 1GHZ) 3. Antenna-port Conducted Test

Test Setup Photos

Test Set-Up Photos 1. DFS Test

Test Setup Photos

Test Set-Up Photos 1. Conducted Test 2. Radiated Test (B ELOW 1GHZ) (ABOVE 1GHZ) 3. Antenna-port Conducted Test

Contact Information

Applicant

Yongping Shi
[email protected]+86-021-57234888Fax: +86-021-57234090

Technical Contact

Audix Technology (Shanghai) Co., Ltd.Byron Kwo
[email protected]86-21-64955500

3F 34Bldg 680 Guiping Rd., Caohejing Hi-Tech Park · Shanghai · China

Non-Technical Contact

Audix Technology (Shanghai) Co., Ltd.Alan He
[email protected]86-21-64955500

Test Firm

Audix Technology (Shanghai) Co., Ltd.Kathy Wang
[email protected]86-21-64955500Fax: 86-21-64955491

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz126.20 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. Device is a 802.11b/g/n device as described in this filing. The device has been certified for mobile use and any co-location must be done through the use of FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device only has a 20 MHz bandwidth mode, it contains Bluetooth and 5 GHz WLAN transmitter.