Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
54.34 mm
[ShenzhenSowakElectronicCo.,Ltd.] [No.88,JinkangRoad,JinshaCommunity,KengziStreet,PingshanDist.,Shenzhen, Guangdong,China] Date:[2025.10.29] FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 FCCID:2AS3I-V40106W FRN:0028404507 USAgent–AttestationStatement/Part2.911(d)(7) [ShenzhenSowakElectronicCo.,Ltd]certifies,thatasof[2025.10.29],wehavedesignated SakarInternational,InctoacceptserviceofprocessonourbehalfforFCCID:2AS3I-V40106W [ShenzhenSowakElectronicCo.,Ltd],acceptstomaintainanagentofserviceofprocessinthe UnitedStatesfornolessthanoneyearafterherthegranteehaspermanentlyterminatedall marketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofany Commission-relatedadministrativeorjudicialproeitceedinginvolvingtheequipment,whicheveris later. SakarInternational,Inc,acceptsasofthedateofthefilingofthisapplication,theobligationof beingthedesignatedagentforthepurposeofacceptingserviceofprocessonbehalfof [ShenzhenSowakElectronicCo.,Ltd]forFCCID:2AS3I-V40106W DesignatedAgentInformation: CompanyName:SakarInternational,Inc FRN:0028102671 Address:195CarterDriveEdison,Edison,NJ8817UnitedStates ContactPerson: DAWNLEITAO Phone: ( 800 ) 637-1090 Email:[email protected] Sincerely, Company:[ShenzhenSowakElectronicCo., Ltd] DesignatedAgent:[SakarInternational,Inc] CompanyRepresentative:[YiZhang]DesignatedAgentRepresentative:[DAWNLEITAO] Signature: Signature:
Rev1/26/2023 (ShenzhenSowakElectronicCo.,Ltd.) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2025.11.24 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2AS3I-V40106W ShenzhenSowakElectronicCo.,Ltd.(“theapplicant”)certifiesthattheequipmentforwhich authorizationissoughtisnot“covered”equipmentprohibitedfromreceivinganequipment authorizationpursuanttosection2.903oftheFCCrules. ShenzhenSowakElectronicCo.,Ltd.(“theapplicant”)certifiesthattheequipmentforwhich authorizationissoughtdoesnotincludecybersecurityoranti-virussoftwareproducedorprovidedby KasperskyLab,Inc.oranyofitssuccessorsandassignees,includingequipmentwithintegratedKaspersky Lab,Inc.(oranyofitssuccessorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24- 886andKDB986446D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, YiZhang Rev1/26/2023 (ShenzhenSowakElectronicCo.,Ltd.) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2025.11.24 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2AS3I-V40106W ShenzhenSowakElectronicCo.,Ltd.(“theapplicant”)certifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofits subsidiariesoraffiliates)asanentityproducing“covered”equipment. Sincerely, YiZhang
ShenzhenSowakElectronicCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Date:2025.11.24 SUBJECT:FCCID:2AS3I-V40106W ToWhomItMayConcern: I,theundersigned,herebystatesthisequipmenthasbeentestedandfoundtocomply withthelimitsforaClassBdigitaldevice,pursuanttopart15oftheFCCRules,and willapplytheSupplier'sDeclarationofConformityproceduretotheclassB computerperipheralportionofthiscompositedevice.IunderstandthefollowingFCC requirements: 1.DevicessubjecttotheSDoCprocedurearerequiredtobetestedtoshow compliancewiththeFCCtechnicalregulationsbyarecognizedaccreditedtesting laboratory.ThetestinglaboratorymustbeaccreditedbyaCommissionapproved accreditationbodyordesignatedunderthetermsofagovernment-to-government MutualRecognitionAgreement(MRA).Alistingofthoseaccreditedtesting laboratoriesthathavebeenrecognizedbytheCommissionispublishedontheFCC Webpage:https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm(Selectthe "accredited"optiontosearchforFCCrecognizedaccreditedtestfirms.) 2.Pt2.1077containsthelistofinformationthatmustbeincludedintheSupplier's DeclarationofConformity,whichmustbesuppliedwitheachproductsold.The SDoCcomplianceinfoshallbeincludedintheUser’sManualorasaseparate sheet.Theinfomustcontainthename,address,andphonenumberofthe responsibleparty,whichmustbelocatedwithintheUnitedStates.Accordingto 2.909(b),theresponsiblepartyiseithertheManufactureroriftheproductis importedtheImporter. Regards, ShenzhenSowakElectronicCo.,Ltd. ------------------------------- (YiZhang)
Rev11/20/07 ShenzhenSowakElectronicCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationof FCCID:2AS3I-V40106W PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName BlockDiagram Schematics OperationalDescription BlockDiagram Schematics OperationalDescription Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateoftheGrant forthisapplication. PursuanttoDA04-1705June15,2004oftheCommission’spublicnotice,Wealsorequestingthe commissiontograntshort-termconfidentialityrequestonthefollowingattachmentsuntil180 daysaftertheGrantDateofEquipmentAuthorizations. ExhibitTypeFileName Date:2025.11.24 Sincerely, YiZhang
ShenzhenSowakElectronicCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7453OaklandMillsRoad Columbia,MD21046 Date:2025.11.24 SUBJECT:FCCApplicationfor(FCCID:2AS3I-V40106W) ToWhomItMayConcern: We,theundersigned,herebyauthorizeSamLvatEMTEK(DONGGUAN)CO.,LTD.on ourbehalf,toapplytotheFederalCommunicationsCommissiononourequipment.Any andallactscarriedoutbyEMTEK(DONGGUAN)CO.,LTD.onourbehalfshallhave thesameeffectasactsofourown. ThisistoadvisethatweareinfullcompliancewiththeAnti-DrugAbuseAct.We,the applicant,arenotsubjecttoadenialoffederalbenefitspursuanttoSection5301ofthe Anti-DrugActof1988,21USC853a,andnopartytotheapplicationissubjecttoadenial offederalbenefitspursuanttothatsection. Regards, Sincerely, YiZhang
ReportNo.ENS2510300257W004Page1of6Ver.1.0 FCCID:2AS3I-V40106W ReportNo.ENS2510300257W004Page2of6Ver.1.0 ReportNo.ENS2510300257W004Page3of6Ver.1.0 ReportNo.ENS2510300257W004Page4of6Ver.1.0 ReportNo.ENS2510300257W004Page5of6Ver.1.0 ReportNo.ENS2510300257W004Page6of6Ver.1.0
The FCC ID is in the user manual due to the size of the device and the FCC ID is included on the device packaging.
ReportNo.ENS2510300257W004Page1of2Ver.1.0 FCCID:2AS3I-V40106W ReportNo.ENS2510300257W004Page2of2Ver.1.0 BTANT
ReportNo.ENS2510300257W00402RPage1of7Ver.1.0 $二维码$ TESTREPORT ProductName:ActiveNoiseCancellingTrueWirelessEarbuds ModelNumber:V40106W FCCID : 2AS3I-V40106W Preparedfor:ShenzhenSowakElectronicCo.,Ltd. Address:No.88,JinkangRoad,JinshaCommunity,KengziStreet, Pingshan,Shenzhen,518122,China Preparedby:EMTEK(SHENZHEN)CO.,LTD. Address:Building69,MajialongIndustryZone,NanshanDistrict, Shenzhen,Guangdong,China TEL:(0755)26954280 FAX:(0755)26954282 ReportNumber:ENS2510300257W00402R Dateofsamplereceipt:Oct30,2025 Date(s)ofTests:Oct30,2025toNov20,2025 Dateofissue:Nov21,2025 ReportNo.ENS2510300257W00402RPage2of7Ver.1.0 TableofContents 1.TESTRESULTCERTIFICATION...............................................................................................................................................3 2.EUTSPECIFICATION.................................................................................................................................................................5 3.TESTREQUIREMENT................................................................................................................................................................6 4.MEASUREMENTRESULT.........................................................................................................................................................7 ReportNo.ENS2510300257W00402RPage3of7Ver.1.0 1.TESTRESULTCERTIFICATION Applicant:ShenzhenSowakElectronicCo.,Ltd. Address: No.88,JinkangRoad,JinshaCommunity,KengziStreet,Pingshan,Shenzhen, 518122,China Manufacturer:ShenzhenSowakElectronicCo.,Ltd. Address: No.88,JinkangRoad,JinshaCommunity,KengziStreet,Pingshan,Shenzhen, 518122,China Factory:ShenzhenSowakElectronicCo.,Ltd. Address: No.88,JinkangRoad,JinshaCommunity,KengziStreet,Pingshan,Shenzhen, 518122,China EUT:ActiveNoiseCancellingTrueWirelessEarbuds ModelName:V40106W Trademark:N/A MeasurementProcedureUsed: APPLICABLESTANDARDS STANDARDTESTRESULT §15.247(i),§2.1093 PASS TheaboveequipmentwastestedbyEMTEK(SHENZHEN)CO.,LTD.Thetestdata,dataevaluation,test procedures,andequipmentconfigurationsshowninthisreportweremadeinaccordancewiththeprocedures giveninANSIC63.10(2020)andtheenergyemittedbythesampleEUTtestedasdescribedinthisreportisin compliancewiththerequirementsofFCCRulesFCC§15.247(i),§2.1093. Thetestresultsofthisreportrelateonlytothetestedsampleidentifiedinthisreport DateofTest:Oct30,2025toNov20,2025 Preparedby: UnaYu/Editor Reviewer: JoeXia/Supervisor Approve&AuthorizedSigner:LisaWang/Manager ReportNo.ENS2510300257W00402RPage4of7Ver.1.0 ModifiedHistory VersionReportNo.RevisionDateSummary ENS2510300257W00402R/OriginalReport ReportNo.ENS2510300257W00402RPage5of7Ver.1.0 2. EUTSpecification CharacteristicsDescription Product:ActiveNoiseCancellingTrueWirelessEarbuds ModelNumber:V40106W Sample:1# DataRate: 1MbpsforGFSKmodulation 2Mbpsforπ/4-DQPSKmodulation 3Mbpsfor8DPSKmodulation Modulation: GFSK,π/4-DQPSK,8DPSK OperatingFrequency Range(s): 2402-2480MHz NumberofChannels: 79channels TransmitPowerMax: 0.81dBm(0.001205W) AntennaGain:-0.81dBi Powersupply: DC5VfromUSB DC3.7Vfrombattery Evaluationapplied:MPEEvaluation SAREvaluation ReportNo.ENS2510300257W00402RPage6of7Ver.1.0 3. TestRequirement SAREvaluation Accordingto447498D01V06,systemsoperatingundertheprovisionsofthissectionshallbeoperatedina mannerthatensuresthatthepublicisnotexposedtoradiofrequencyenergylevelinexcessofthe Commission’sguidelines. RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,usingmeasurementsorcomputer simulation.WhenroutineSARevaluationisnotrequired,portabletransmitterswithoutputpowergreaterthan theapplicablelowthresholdrequireSARevaluationtoqualityforTCBapproval. OneantennaisavailablefortheEUT.Theminimumseparationdistanceis5mm. ReportNo.ENS2510300257W00402RPage7of7Ver.1.0 4. MeasurementResult Antennagain:-0.81dBi Transmit Frequency (MHz) Mode Measured Power (dBm) Tuneup Power (dBm) Maxtune uppower (dBm) Calculation Result Calculation threshold(1 -gSAR) 2402GFSK-1.47 -1±10 0.31003 2441GFSK-1.45-1±100.31253 2480GFSK-0.110±110.39653 2402Π/4-DQPSK-0.930±110.39023 2441Π/4-DQPSK-1.02-1±100.31253 2480Π/4-DQPSK0.330±110.39653 2402 8DPSK -0.570±110.39023 2441 8DPSK -0.460±110.39343 2480 8DPSK 0.810±110.39653 AccordingtoKDB447498D01V06,nostand-alonerequiredforBTantenna,andnosimultaneousSAR measurementisrequired. ***EndofReport***
dipole antenna Specification Summary ITEM ANT SPEC Model Name 2.4G ANT Horizontal Vertical 2400MHz 2450MHz2500MHz2400MHz2450MHz 2500MHz Center Frequency -1.73dBi -0.84dBi -0.81dBi -6.15dBi -3.70dBi -2.32dBi MAX. Gain -0.81dBi Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance 50 Ohm Antenna Length 3.8mm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Gain(dB) Frequency (MHz) Max Min Avg 2400 -1.73178 -30.0815 -8.48713 2450 -0.845801 -38.5605 -7.88012 2500 -0.81257-24.0318 -6.79139 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Gain(dB) Frequency (MHz) Max Min Avg 2400 -6.1530 -24.1420 -13.0295 2450 -3.7054 -26.5836 -10.6700 2500 -2.32122 -30.4301 -9.70536 ANT Test Labs:Attestation of Global Compliance Co., Ltd.
ReportNo.ENS2510300257W00401RPage1of73Ver.1.0 TESTREPORT ProductName:ActiveNoiseCancellingTrueWirelessEarbuds ModelNumber:V40106W FCCID:2AS3I-V40106W Preparedfor:ShenzhenSowakElectronicCo.,Ltd. Address:No.88,JinkangRoad,JinshaCommunity,KengziStreet, Pingshan,Shenzhen,518122,China Preparedby:EMTEK(SHENZHEN)CO.,LTD. Address:Building69,MajialongIndustryZone,NanshanDistrict, Shenzhen,Guangdong,China TEL:(0755)26954280 FAX:(0755)26954282 ReportNumber:ENS2510300257W00401R Dateofsamplereceipt:Oct30,2025 Date(s)ofTests:Oct30,2025toNov20,2025 Dateofissue:Nov21,2025 $二维码$ ReportNo.ENS2510300257W00401RPage2of73Ver.1.0 TableofContents 1TESTRESULTCERTIFICATION..................................................................................................................................................3 2EUTTECHNICALDESCRIPTION.................................................................................................................................................5 3SUMMARYOFTESTRESULT.....................................................................................................................................................6 4TESTMETHODOLOGY.................................................................................................................................................................7 4.1GENERALDESCRIPTIONOFAPPLIEDSTANDARDS......................................................................................................7 4.2MEASUREMENTEQUIPMENTUSED..................................................................................................................................7 4.3DESCRIPTIONOFTESTMODES..........................................................................................................................................8 5FACILITIESANDACCREDITATIONS........................................................................................................................................9 5.1FACILITIES..............................................................................................................................................................................9 5.2EQUIPMENT............................................................................................................................................................................9 5.3LABORATORYACCREDITATIONSANDLISTINGS.........................................................................................................9 6TESTSYSTEMUNCERTAINTY.................................................................................................................................................10 7SETUPOFEQUIPMENTUNDERTEST.....................................................................................................................................11 7.1RADIOFREQUENCYTESTSETUP1.................................................................................................................................11 7.2RADIOFREQUENCYTESTSETUP2.................................................................................................................................11 7.3CONDUCTEDEMISSIONTESTSETUP.............................................................................................................................13 7.4BLOCKDIAGRAMCONFIGURATIONOFTESTSYSTEM.............................................................................................14 7.5SUPPORTEQUIPMENT........................................................................................................................................................14 8FREQUENCYHOPPINGSYSTEMREQUIREMENTS...............................................................................................................15 8.1StandardApplicable.................................................................................................................................................................15 8.2EUTPseudorandomFrequencyHoppingSequence................................................................................................................15 8.3EqualHoppingFrequencyUse................................................................................................................................................16 8.4FrequencyHoppingSystem.....................................................................................................................................................16 9TESTREQUIREMENTS...............................................................................................................................................................17 9.120DB&99%BANDWIDTH.....................................................................................................................................................17 9.2CARRIERFREQUENCYSEPARATION..............................................................................................................................28 9.3NUMBEROFHOPPINGFREQUENCIES............................................................................................................................31 9.4AVERAGETIMEOFOCCUPANCY(DWELLTIME)........................................................................................................34 9.5MAXIMUMPEAKCONDUCTEDOUTPUTPOWER.........................................................................................................44 9.6CONDUCTEDSUPRIOUSEMISSION.................................................................................................................................50 9.7RADIATEDSPURIOUSEMISSION.....................................................................................................................................60 9.8CONDUCTEDEMISSIONTEST...........................................................................................................................................69 9.9ANTENNAAPPLICATION........................................................................................................…
Text truncated - open the document above for the full version.
ReportNo.ENS2510300257W00401RPage40of73Ver.1.0 2DH5-Ant1-Hop-PASS ReportNo.ENS2510300257W00401RPage41of73Ver.1.0 3DH1-Ant1-Hop-PASS ReportNo.ENS2510300257W00401RPage42of73Ver.1.0 3DH3-Ant1-Hop-PASS ReportNo.ENS2510300257W00401RPage43of73Ver.1.0 3DH5-Ant1-Hop-PASS ReportNo.ENS2510300257W00401RPage44of73Ver.1.0 9.5MAXIMUMPEAKCONDUCTEDOUTPUTPOWER 9.5.1ApplicableStandard AccordingtoFCCPart15.247(b)(1)andKDB558074D0115.247MEASGUIDANCEv05r02 AccordingtoICRSS-247.5.4andRSS-Gen6.12 9.5.2ConformanceLimit ThemaxForfrequencyhoppingsystemsoperatinginthe2400-2483.5MHzbandemployingatleast75 non-overlappinghoppingchannels:1watt.Forallotherfrequencyhoppingsystemsinthe2400-2483.5MHzband: 0.125watts. 9.5.3TestConfiguration Testaccordingtoclause7.1radiofrequencytestsetup1 9.5.4TestProcedure Asanalternativetoapeakpowermeasurement,compliancewiththelimitcanbebasedonameasurementofthe maximumconductedoutputpower. Usethefollowingspectrumanalyzersettings: SetSpan=approximately5timesthe20dBbandwidth,centeredonahoppingchannel(about8MHz) SetRBW>the20dBbandwidthoftheemissionbeingmeasured(about3MHz) SetVBW RBW SetSweep=auto SetDetectorfunction=peak SetTrace=maxhold Allowthetracetostabilize.Usethemarker-to-peakfunctiontosetthemarkertothepeakoftheemissionto determinethepeakamplitudelevel. TestResults Temperature: 25 ̊ C RelativeHumidity:45% ATMPressure:1011mbar Note:N/A Test Mode AntennaFrequency[MHz] ConductedPeak Powert[dBm] Conducted Limit[dBm] Verdict DH5Ant12402-1.47≤20.97PASS DH5Ant12441-1.45≤20.97PASS DH5Ant12480-0.11≤20.97PASS 2DH5Ant12402-0.93≤20.97PASS 2DH5Ant12441-1.02≤20.97PASS 2DH5Ant124800.33≤20.97PASS 3DH5Ant12402-0.57≤20.97PASS 3DH5Ant12441-0.46≤20.97PASS 3DH5Ant124800.81≤20.97PASS ReportNo.ENS2510300257W00401RPage45of73Ver.1.0 DH5-Ant1-2402-PASS DH5-Ant1-2441-PASS ReportNo.ENS2510300257W00401RPage46of73Ver.1.0 DH5-Ant1-2480-PASS 2DH5-Ant1-2402-PASS ReportNo.ENS2510300257W00401RPage47of73Ver.1.0 2DH5-Ant1-2441-PASS 2DH5-Ant1-2480-PASS ReportNo.ENS2510300257W00401RPage48of73Ver.1.0 3DH5-Ant1-2402-PASS 3DH5-Ant1-2441-PASS ReportNo.ENS2510300257W00401RPage49of73Ver.1.0 3DH5-Ant1-2480-PASS ReportNo.ENS2510300257W00401RPage50of73Ver.1.0 9.6CONDUCTEDSUPRIOUSEMISSION 9.6.1ApplicableStandard AccordingtoFCCPart15.247(d)andKDB558074D0115.247MEASGUIDANCEv05r02 AccordingtoICRSS-2475.5 9.6.2ConformanceLimit Inany100kHzbandwidthoutsidethefrequencybandinwhichthespreadspectrumintentionalradiatoris operating,theradiofrequencypowerthatisproducedbytheintentionalradiatorshallbeatleast20dBbelowthat inthe100kHzbandwidthwithinthebandthatcontainsthehighestlevelofthedesiredpower,basedoneitheran RFconducted,providedthetransmitterdemonstratescompliancewiththepeakconductedpowerlimits. 9.6.3TestConfiguration Testaccordingtoclause7.1radiofrequencytestsetup1 9.6.4TestProcedure Thetransmitteroutput(antennaport)wasconnectedtothespectrumanalyzer Referencelevelmeasurement Establishareferencelevelbyusingthefollowingprocedure: SetinstrumentcenterfrequencytoDSSchannelcenterfrequency. SetSpan=approximately5timesthe20dBbandwidth,centeredonahoppingchannel. SettheRBW=100kHz.SettheVBW≥3xRBW. SetDetector=peak.SetSweeptime=autocouple. SetTracemode=maxhold.Allowtracetofullystabilize. UsethepeakmarkerfunctiontodeterminethemaximumMaximumconducetedlevel. Notethatthechannelfoundtocontainthemaximumconducetedlevelcanbeusedtoestablishthereference level. Band-edgemeasurement Usethefollowingspectrumanalyzersettings: Span=wideenoughtocapturethepeakleveloftheemissionoperatingonthechannelclosesttotheband-edge, aswellasanymodulationproductswhichfalloutsideoftheauthorizedbandofoperation SetRBW 1%ofthespan=100kHzSetVBW 3xRBW SetSweep=autoSetDetectorfunction=peakSetTrace=maxhold Allowthetracetostabilize.Setthemarkerontheemissionatthebandedge,oronthehighestmodulation productoutsideoftheband,ifthislevelisgreaterthanthatatthebandedge.Enablethemarker-deltafunction, thenusethemarker-to-peakfunctiontomovethemarkertothepeakofthein-bandemission.Themarker-delta valuenowdisplayedmustcomplywiththelimitspecifiedinthisSection. Now,usingthesameinstrumentsettings,enablethehoppingfunctionoftheEUT.Allowthetracetostabilize. Followthesameprocedurelistedabovetodetermineifanyspuriousemissionscausedbythehoppingfunction alsocomplywiththespecifiedlimit. Emissionlevelmeasurement Usethefollowingspectrumanalyzersettings: Span=wideenoughtocapturethepeaklevelofthein-bandemissionandallspuriousemissions(e.g.,harmonics) fromthelowestfrequencygeneratedintheEUTupthroughthe10thharmonic.(30MHzto25GHz).SetRBW= 100kHzSetVBW RBW SetSweep=autoSetDetectorfunction=peakSetTrace=maxhold Allowthetracetostabilize.Setthemarkeronthepeakofanyspuriousemissionrecorded.Theleveldisplayed mustcomplywiththelimitspecifiedinthisSection. ReportNo.ENS2510300257W00401RPage51of73Ver.1.0 9.6.5TestResults Temperature: 25 ̊ C RelativeHumidity:45% ATMPressure:1011mbar Note:N/A Alltheantennaandmodesmodehavebeentested,andtheworstresultrecordedwasreportasbelow: Bandedgemeasurements TestModeAntennaChNameFrequency[MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant1Low2402-2.70-46.26≤-22.7PASS DH5Ant1High2480-1.31-45.62≤-21.31PASS DH5Ant1LowHop_2402-2.77-42.09≤-22.77PASS DH5Ant1HighHop_2480-0.96-45.49≤-20.96PASS ReportNo.ENS2510300257W00401RPage52of73Ver.1.0 DH5-Ant1-2402-PASS DH5-Ant1-2480-PASS ReportNo.ENS2510300257W00401RPage53of73Ver.1.0 DH5-Ant1-Hop_2402-PASS DH5-Ant1-Hop_2480-PASS ReportNo.ENS2510300257W00401RPage54of73Ver.1.0 ConductedSpuriousEmission TestModeAntennaFrequency[MHz] FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant124020~Reference-2.45-2.45---PASS DH5Ant1240230~1000-2.45-60.38≤-22.45PASS DH5Ant124021000~26500-2.45-42.79≤-22.45PASS DH5Ant124410~Reference-2.44-2.44---PASS DH5Ant1244130~1000-2.44-60.91≤-22.44PASS DH5Ant124411000~26500-2.44-50.86≤-22.44PASS DH5Ant124800~Reference-1.32-1.32---PASS DH5Ant1248030~1000-1.32-59.92≤-21.32PASS DH5Ant124801000~26500-1.32-46.21≤-21.32PASS ReportNo.ENS2510300257W00401RPage55of73Ver.1.0 DH5-Ant1-2402-0~Reference-PASS DH5-Ant1-2402-30~100…
Text truncated - open the document above for the full version.
ReportNo.ENS2510300257W004Page1of2Ver.1.0 FCCID:2AS3I-V40106W ReportNo.ENS2510300257W004Page2of2Ver.1.0
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.20 mW |

Flocked true wireless earbuds
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
True Wireless Earphones with charging Case
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Wireless Headphones with Solar Charging
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Open Wearable True Wireless Earbuds
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
True Connect View ENC TWS earphones with digital display
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter