FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Jamr Technology Co., Ltd/
  3. 2AS8AC05T

2AS8AC05TBlood Pressure Monitor

Shenzhen Jamr Technology Co., Ltd
Blood Pressure Monitor - FCC ID 2AS8AC05T - Shenzhen Jamr Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 15, 2026
Application Purpose
Original Equipment
Equipment Note
Blood Pressure Monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Jamr Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 ShenzhenJamrTechnologyCo.,Ltd. A101-301,D101-201,JamrScience&TechnologyPark, No.2GuiyuanRoad,GuixiangCommunity,GuanlanStreet, LonghuaDistrict,518100Shenzhen,PEOPLE'SREPUBLICOFCHINA ShanghaiInternationalHoldingCorp.GmbH(Europe) Eiffestrasse80,20537Hamburg,Germany VersionNumber:1.0 Revisondate:2025.04.25 2 BloodPressureMonitor ModelNumber:C05T ---------------------------------------------------------------- USER’SMANUAL 3 CONTENTS 1IntroductionandIntendedUse................................................................................................4 2ImportantInformationonBloodPressureanditsMeasurement.............................................6 3ComponentsofYourBloodPressureMonitor.........................................................................7 4UsingyourMonitorfortheFirstTime......................................................................................8 5MeasurementProcedure.........................................................................................................9 6CareandMaintenance..........................................................................................................15 7Warranty/Service...................................................................................................................16 8Certifications..........................................................................................................................16 9TechnicalSpecification..........................................................................................................16 10FCCStatement....................................................................................................................17 11EMCDeclaration.................................................................................................................18 4 1IntroductionandIntendedUse Thedeviceisafullyautomaticdigitalbloodpressuremeasuringdeviceusing oscillometrictechniquetomeasuresystolicanddiastolicbloodpressureas wellasthepulseforadultsthatagesaremorethan12yearsoldbywrapping aroundtheupperarmwithcuffcircumferencerangingfrom22cmto42cm.The devicecanbeusedinmedicalfacilitiesorathome,andonlyforindooruse. Contraindication:Thedeviceisnotusedforpatientsunderdialysistherapyor onanticoagulant,antiplatelets,orsteroids. Thedeviceisprovideaccuratebloodpressuremeasurementvaluesthatare effective andsuitableforclinicalandhomeuse. Beforeusing,pleasereadthisinstructionmanualcarefullyandthenkeep itinasafeplace. 1.1Remember... •Onlyahealth-careprofessionalisqualifiedtointerpretbloodpressure measurements. •ThisdeviceisNOTintendedtoreplaceregularmedicalcheckups. •Thedeviceisnotintendedforusepregnantpatient.Theeffectivenesshasnot beenestablishedinpregnant(includingpre-eclamptic)patients. •Incasesofirregularheartbeat,measurementsmadewiththisinstrument shouldonlybeevaluatedafterconsultationwithaphysician. •Theproducts,includingaccessories,shallbeprocessedinaccordancewith localregulationsafterreachingthelifecycle. •Anyseriousincidentthathasoccurredinrelationtothedeviceshouldbe reportedtothemanufacturerandthecompetentauthorityoftheMemberState inwhichtheuserand/orpatientisestablished. 1.2WarningsandPrecautions Warning:DonotusetheACadapteriftheunitorthepowercordisdamaged. Turnoffthepowerandunplugthepowercordimmediately. Warning:Thedeviceisnotsuitableforuseinthepresenceofflammable anestheticmixtureswithairorwithoxygenornitrousoxide. Warning:Ifthepatientisanintendedoperator,thefunctionsofmonitoring bloodpressureandpulseratecanbesafelyusedbypatient.Theroutineclean andchangingbatteriescanbeperformedbythepatient. Warning:ThedeviceprovidesaDCinputportconnectedtoexternalac adapter.Itisrecommendedthatusetheadapterspecifiedbythemanufacturer. 5 Theadaptershouldmeetthefollowingconditions:classIIequipment,output voltage:DC5V,current:≥1A,andcomplywithIEC60950,IEC60601-1orIEC 62368-1,provideatleasttwoMOOPinsulationbetweenacinputanddcoutput. ExternaladapterconnectedtomedicalelectricalequipmentthroughtheDC inputportmustcomplywiththerespectiveIECorISOstandards(e.g.IEC 60950orIEC62368-1fordataprocessingequipment).Furthermoreall configurationsshallcomplywiththerequirementsformedicalelectrical systems(seeIEC60601-1-1orclause16ofthe3Ed.ofIEC60601-1, 60601-1-2,respectively).Anybodyconnectingexternaladaptertomedical electricalequipment configurationsamedicalsystemandisthereforeresponsiblethatthesystem complieswiththerequirementsformedicalelectricalsystems.Attentionis drawntothefactthatlocallawstakepriorityovertheabovementioned requirements.Ifindoubt,consultyourlocalrepresentativeorthetechnical servicedepartment. Warning:ToofrequentmeasurementscancauseinjurytothePATIENTdueto bloodflowinterference. Warning:Don’tplacethecuffoverwoundpart. Warning:PressurizationoftheCUFFcantemporarilycauselossoffunctionof simultaneouslyusedmonitoringMEEQUIPMENTonthesamelimb. Warning:Regularlycheckingtheoperationofthebloodpressuremonitorto ensurethatitdoesnotcauselong-termdamagetothepatient'sblood circulation. Warning:ApplyCUFFanditspressurizationonthesideofthepatient's mastectomyor lymphnoderemovalcancauseinjury. Warning:Toavoidanypossibilityofaccidentalstrangulation,keepthisdevice awayfromchildrenanddonotdrapetubingaroundyourneck. Caution:Theusermustcheckthattheequipmentfunctionssafelyandseethat itisinproperworkingconditionbeforebeingused. Caution:Toavoiddamagingthedevice,keepthisunitawayfromchildrenand pets. Caution:Thestandardmaterialusedforthebladderandtubingislatex-free. Caution:Thedeviceisintendedtomonitor,nottodiagnose.Unusualvalues havetobealwaysdiscussedwithaphysician.Underanycircumstance,you shouldnotalterthedosagesofanydrugsprescribedbyaphysician. Caution:ThedevicecannotbeusedtosubstitutetheprofessionalECG monitordeviceformonitoringthefrequencyofheartbeat. Caution:ThisdevicecannotbeusedtogetherwithHFsurgicalequipment. Note:Toobtainthegreatestaccuracyfromyourbloodpressuremonitor,itis recommendedthattheinstrumentbeusedwithinthespecifiedtemperature andtherelativehumidity,pleaseseetheTechnicalSpecifications. Note:T…

Text truncated - open the document above for the full version.

Attestation Statements

EUT Name Upper Arm Type Blood Pressure Monitor Model No. Inverted-L Antenna Environmental Conditions 21.4°C/43%RH/101kPa Test Scene Scene 1 Power Supply / Tested By Xu Xing Qiu Test Date 2023/3/13 Sample No. E202212139826-0003 Antenna polarizatiob / Impedance 50Ω Antenna photo and length(mm) Frequency(MHz)Gain(dBi)Efficiency(%) AverageGain(dBi) Effciency(dB) 2400-7.3716.20%-12.801-12.079 2410-6.966.76%-12.312-11.7 2420-6.5827.45%-11.891-11.279 2430-6.9786.92%-12.292-11.602 2440-7.3786.32%%-12.698-11.996 2450-7.2376.42%-12.586-11.925 2460-7.0956.71%-12.233-11.735 2470-6.8117.36%-11.631-11.333 2480-6.3018.53%-10.864-10.692 2490-6.0759.13%-10.614-10.394 2500-6.1068.77%-10.998-10.571 Frequency(MHz)24002410242024302440245024602470248024902500 Gain(dBi)-7.371-6.96-6.58-6.98-7.378-7.237-7.095-6.811-6.301-6.075-6.106 Frequency(MHz)24002410242024302440245024602470248024902500 Efficiency(%)6.20%6.76%7.45%6.92%6.32%6.42%6.71%7.36%8.53%9.13%8.77% 2400Mhz 90 Total(H-XY) 2400Mhz 0 Total(E1-XZ) 2400Mhz 90 Total(E2-YZ) 2410Mhz 90 Total(H-XY) 2410Mhz 0 Total(E1-XZ), 2410Mhz 90 Total(E2-YZ) 2420Mhz 90 Total(H-XY) 2420Mhz 0 Total(E1-XZ), 2420Mhz 90 Total(E2-YZ) 2430Mhz 90 Total(H-XY) 2430Mhz 0 Total(E1-XZ) 2430Mhz 90 Total(E2-YZ) 2440Mhz 90 Total(H-XY) 2440Mhz 0 Total(E1-XZ), 2440Mhz 90 Total(E2-YZ) 2450Mhz 90 Total(H-XY) 2450Mhz 0 Total(E1-XZ), 2450Mhz 90 Total(E2-YZ) 2460Mhz 90 Total(H-XY) 2460Mhz 0 Total(E1-XZ), 2460Mhz 90 Total(E2-YZ) 2470Mhz 90 Total(H-XY) 2470Mhz 0 Total(E1-XZ), 2470Mhz 90 Total(E2-YZ) 2480Mhz 90 Total(H-XY) 2480Mhz 0 Total(E1-XZ) 2480Mhz 90 Total(E2-YZ) 2490Mhz 90 Total(H-XY) 2490Mhz 0 Total(E1-XZ), 2490Mhz 90 Total(E2-YZ) 2500Mhz 90 Total(H-XY) 2500Mhz 0 Total(E1-XZ) 2500Mhz 90 Total(E2-YZ) 2400 2450 2500

Attestation Statements

ShenzhenJamrTechnologyCo.,Ltd 2026-01-05 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:AttestationStatementsPart2.911(d)(5)(i)requestfor(FCCID:2AS8AC05T) [ShenzhenJamrTechnologyCo.,Ltd]certifiesthattheequipmentforwhich authorizationissoughtisnot“covered”equipmentprohibitedfromreceivingan equipmentauthorizationpursuanttosection2.903oftheFCCrules. Wealsocertifythat,asofthedateofthefilingoftheapplication,theequipmentdoes notutilizecyber-securityoranti-virussoftwarefromKasperskyLab,Inc,oranyofits successorsandassignees,whichisalsoonthe“coveredlist”. Sincerely, FushengLuo ShenzhenJamrTechnologyCo.,Ltd 2025-01-05 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:AttestationStatementsPart2.911(d)(5)(ii)requestfor(FCCID:2AS8AC05T) [ShenzhenJamrTechnologyCo.,Ltd]certifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredListasanentityproducing “covered”equipment. Sincerely, FushengLuo

Cover Letter(s)

ShenzhenJamrTechnologyCo.,Ltd AgentAuthorizationLetter 2026-01-05 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 USA RE:LETTEROFAGENTAUTHORIZATION ToWhomItMayConcern: We,theundersigned,herebyauthorizeShenzhenMostTechnologyServiceCo.,Ltd.toact onourbehalfinallmattersrelatingtoapplicationforequipmentauthorization,includingthe signingofalldocumentsrelatingtothesematters. Wealsoherebycertifythatnopartytotheapplicationauthorizedhereunderissubjecttothe denialofbenefits,includingFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuse Actof1988,21U.S.C.853(a). Thisagreementexpiresoneyearfromthecurrentdate. Sincerely, Name:FushengLuo Position:RAManager CompanyName:ShenzhenJamrTechnologyCo.,Ltd Address:A101-301,D101-201,JamrScience&TechnologPark,No.2Guiyuan Road,GuanlanStreet,LonghuaDistrict,China Tel/Fax86-755-85292057/86-755-27980758 E-Mail:[email protected]

Cover Letter(s)

ShenzhenJamrTechnologyCo.,Ltd LongTermConfidentialityRequestLetter 2026-01-05 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 USA RE:CONFIDENTIALITYREQUESTFOR(FCCID:2AS8AC05T) ToWhomItMayConcern: Thisletterservesasanofficialrequestforconfidentialityundersections0.457and0.459of CFR47.Wehaverequestedthatthe -e.g.Blockdiagram -e.g.SCH -e.g.OperationalDescription requiredtobesubmittedwiththisapplicationbepermanentlywithheldfrompublicreview. Theabovedocumentsarecompanyproprietaryinformationthatcouldnevergetinto thepossessionofyourcompetition. Pleasecontactmeifthereisanyinformationyoumayneed. Sincerely, Name:FushengLuo Position:RAManager CompanyName:ShenzhenJamrTechnologyCo.,Ltd Address:A101-301,D101-201,JamrScience&TechnologPark,No.2Guiyuan Road,GuanlanStreet,LonghuaDistrict,China Tel/Fax86-755-85292057/86-755-27980758 E-Mail:[email protected]

External Photos

ModelNo.:C05T FRONTVIEWOFSAMPLE BACKVIEWOFSAMPLE ModelNo.:C05T LEFTVIEWOFSAMPLE RIGHTVIEWOFSAMPLE ModelNo.:C05T TOPVIEWOFSAMPLE BOTTOMVIEWOFSAMPLE ModelNo.:C05T PHOTOOFTHEENTIRESAMPLE ADAPTERPHOTOOFTHESAMPLE ModelNo.:C05T Photoofopeningthebatterycover

ID Label/Location Info

血压计 C05T 铭牌在机身上的位置

Internal Photos

Model No.: C05T Page 1 of 3 INTERNAL PHOTO OF SAMPLE INTERNAL PHOTO OF SAMPLE PCB Model No.: C05T Page 2 of 3 INTERNAL PHOTO OF SAMPLE PCB INTERNAL PHOTO OF SAMPLE PCB Model No.: C05T Page 3 of 3 INTERNAL PHOTO OF SAMPLE PCB INTERNAL PHOTO OF SAMPLE PCB BT antenna

RF Exposure Info

Shenzhen Most Technology Service Co., Ltd. No.5, 2nd Langshan Road, North District, Hi-tech Industrial Park, Nanshan, Shenzhen, Guangdong, China. RF Exposure Evaluation Report Report Reference No........................: FCC ID.................................................: MTEB25120060-H 2AS8AC05T Compiled by ( position+printed name+signature) .. :File administrators Alisa Luo Supervised by ( position+printed name+signature)..: Test Engineer Sunny Deng Approved by ( position+printed name+signature)..: Manager Yvette Zhou Date of issue.........................................:Dec.05,2025 Representative Laboratory Name.:Shenzhen Most Technology Service Co., Ltd. Address.................................................: No.5, 2nd Langshan Road, North District, Hi-tech Industrial Park, Nanshan, Shenzhen, Guangdong, China. Applicant’s name ............................... :Shenzhen Jamr Technology Co., Ltd. Address.................................................: A101-301, D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road, Guixiang Community,Guanlan Street, Longhua District, 518100 Shenzhen, PEOPLE'S REPUBLIC OF CHINA Test specification/Standard............: 47 CFR Part 1.1307 47 CFR Part 2.1093 TRF Originator......................................:Shenzhen Most Technology Service Co., Ltd. Shenzhen Most Technology Service Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Most Technology Service Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen Most Technology Service Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ........................ : Blood Pressure Monitor Trade Mark ............................................ : N/A Model/Type reference ......................... :C05T Listed Models......................................:N/A Modulation Type..................................:GFSK Operation Frequency..........................:From 2402MHz to 2480MHz HardwareVersion................................... JMR-PCB-B09-AC825A8-A-V1.0 SoftwareVersion.................................... V1 Rating.....................................................: DC 5V by Adapter DC 4.5V by batteries Result.....................................................: PASS Report No.: MTEB25120060-HPage 2 of 5 T E S T R E P O R T Equipment under Test:Blood Pressure Monitor Model /Type:C05T Listed Models:N/A RemarkN/A Applicant:Shenzhen Jamr Technology Co., Ltd. Address: A101-301, D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road, Guixiang Community,Guanlan Street, Longhua District, 518100 Shenzhen, PEOPLE'S REPUBLIC OF CHINA Manufacturer:Shenzhen Jamr Technology Co., Ltd. Address : A101-301, D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road, Guixiang Community,Guanlan Street, Longhua District, 518100 Shenzhen, PEOPLE'S REPUBLIC OF CHINA Test Result : PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: MTEB25120060-HPage 3 of 5 1. Revi sion Histor y RevisionIssue DateRevisionsRevised By 002025.12.05Initial IssueAlisa Luo Report No.: MTEB25120060-HPage 4 of 5 2. SAR Evalu ati on 2.1 RF Exposure Compliance Requirement 2.1.1 Standard Requirement According to KDB447498D01 General RF Exposure Guidance v06 4.3.1. Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed below, is satisfied. 2.1.2 Limits The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances≤50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHz)] ≤3.0 for 1-g SAR and≤7.5 for 10-g extremity SAR, where The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion Report No.: MTEB25120060-HPage 5 of 5 2.1.3 EUT RF Exposure Measurement Data BLE GFSK Test channel Peak Output Power (dBm) Tune up tolerance (dBm) Maximum tune-up Power (dBm) Lowest(2402MHz)2.792.79±13.79 Middle(2440MHz)2.372.37±13.37 Highest(2480MHz)2.832.83±13.83 Worst case: GFSK Channel Maximum Peak Conducted Output Power (dBm) Maximum tune-up Power Calculated value Exclusion threshold SAR Test Exclusion (dBm)(mW) Highest(2480MHz)2.833.832.420.763.0Yes .......................THE END OF REPORT.........................

Test Report

ShenzhenMostTechnologyServiceCo.,Ltd. No.5,2ndLangshanRoad,NorthDistrict,Hi-techIndustrialPark,Nanshan, Shenzhen,Guangdong,China. TESTREPORT FCCRulesPart15.247 ReportReferenceNo........................: FCCID................................................: MTEB25120060-R 2AS8AC05T Compiledby (position+printedname+signature)..:FileadministratorsAlisaLuo Supervisedby (position+printedname+signature)..:TestEngineerSunnyDeng Approvedby (position+printedname+signature)..: ManagerYvetteZhou Dateofissue.........................................:Dec.05,2025 RepresentativeLaboratoryName.:ShenzhenMostTechnologyServiceCo.,Ltd. Address ................................................. : No.5,2ndLangshanRoad,NorthDistrict,Hi-techIndustrialPark, Nanshan,Shenzhen,Guangdong,China. Applicant’sname...............................:ShenzhenJamrTechnologyCo.,Ltd. Address.................................................: A101-301,D101-201,JamrScience&TechnologyPark,No.2 GuiyuanRoad,GuixiangCommunity,GuanlanStreet,Longhua District,518100Shenzhen,PEOPLE'SREPUBLICOFCHINA Testspecification/Standard ............ : FCCRulesPart15.247 TRFOriginator......................................:ShenzhenMostTechnologyServiceCo.,Ltd. ShenzhenMostTechnologyServiceCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenMostTechnologyServiceCo.,Ltd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenMostTechnologyServiceCo.,Ltd.takesnoresponsibilityforandwillnotassume liabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. Testitemdescription........................: BloodPressureMonitor TradeMark...........................: N/A Model/Typereference ......................... :C05T ListedModels ..................................... :N/A ModulationType..................................:GFSK OperationFrequency..........................:From2402MHzto2480MHz HardwareVersion.................................... JMR-PCB-B09-AC825A8-A-V1.0 SoftwareVersion..................................... V1 Rating.....................................................: DC5VbyAdapter DC4.5Vbybatteries Result.....................................................:PASS ReportNo.:MTEB25120060-RPage 2 of 37 TESTREPORT EquipmentunderTest:BloodPressureMonitor Model/Type:C05T ListedModels:N/A RemarkN/A Applicant:ShenzhenJamrTechnologyCo.,Ltd. Address: A101-301,D101-201,JamrScience&TechnologyPark,No.2 GuiyuanRoad,GuixiangCommunity,GuanlanStreet,Longhua District,518100Shenzhen,PEOPLE'SREPUBLICOFCHINA Manufacturer:ShenzhenJamrTechnologyCo.,Ltd. Address : A101-301,D101-201,JamrScience&TechnologyPark,No.2 GuiyuanRoad,GuixiangCommunity,GuanlanStreet,Longhua District,518100Shenzhen,PEOPLE'SREPUBLICOFCHINA TestResult:PASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. ReportNo.:MTEB25120060-RPage 3 of 37 Contents 1.REVISIONHISTORY.........................................................................................................................4 2.TESTSTANDARDS............................................................................................................................5 3.SUMMARY...............................................................................................................................................6 3.1.GeneralRemarks.........................................................................................................................................6 3.2.ProductDescription....................................................................................................................................6 3.3.EquipmentUnderTest................................................................................................................................6 3.4.ShortdescriptionoftheEquipmentunderTest(EUT)............................................................................6 3.5.EUToperationmode....................................................................................................................................7 3.6.BlockDiagramofTestSetup......................................................................................................................7 3.7.TestItem(EquipmentUnderTest)Description*.......................................................................................7 3.8.AuxiliaryEquipment(AE)Description.......................................................................................................7 3.9.AntennaInformation*..................................................................................................................................8 3.10.EUTconfiguration......................................................................................................................................8 3.11.Modifications..............................................................................................................................................8 4.TESTENVIRONMENT.......................................................................................................................9 4.1.Addressofthetestlaboratory...................................................................................................................9 4.2.Environmentalconditions...........................................................................................................................9 4.3.TestDescription.........................................................................................................................................10 4.4.Statementofthemeasurementuncertainty...........................................................................................10 4.5.EquipmentsUsedduringtheTest...........................................................................................................11 5.TESTCONDITIONSANDRESULTS............................…

Text truncated - open the document above for the full version.

Test Setup Photos

Model No.: C05T CE TEST SETUP RE TEST SETUP Model No.: C05T RE TEST SETUP

Contact Information

Applicant

Luo Fusheng(RA Manager)
[email protected]Fax: 86-755-27980758

Technical Contact

UUX GROUP INCJack Fu
[email protected]Fax: 213-3753998

1312 17th Street #692 · Denver, CO80202 · United States

Test Firm

Shenzhen Most Technology Service Co., Ltd.Sunny Deng
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.92 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.