FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Arzin Motocam Intelligent Co.,Ltd/
  3. 2AS8F-R1

2AS8F-R1Wireless Charger

Arzin Motocam Intelligent Co.,Ltd
Wireless Charger - FCC ID 2AS8F-R1 - Arzin Motocam Intelligent Co.,Ltd
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Apr 05, 2020
Application Purpose
Original Equipment
Date of Application
Apr 05, 2020
Equipment Note
Wireless Charger
Frequency Range
0.11150000 - 0.20500000
Company
Arzin Motocam Intelligent Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

RF Exposure Info

↗

Test Report

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Model Difference Declaration To Whom It May Concern, We, Arzin Motocam Intelligent Co., Ltd Product: Wireless Charger Trademark: N/A Model Number: R1, R2, X1, X2 All model’s the function, software and electric circuit are the same, only with a product color, shape, nameplate and model named different. Test sample model: R1 Please contact me if you have any question. Name: Abigail Luo Date: Mar. 24, 2020 Title: Business Manager Signature of applicant:

Cover Letter(s)

Date: Mar. 24, 2020 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AS8F-R1 Product Name: Wireless Charger Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...) • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature> Name: Abigail Luo Title: Business Manager Company: Arzin Motocam Intelligent Co., Ltd

Cover Letter(s)

Date: Mar. 24, 2020 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen CTB Testing Technology Co., Ltd. Add: Floor 1&2, Building A, No. 26 of Xinhe Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, China to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Arzin Motocam Intelligent Co., Ltd Add: Room 222, Wan Yuan Business Building 2, Liuxian Road 2, Baoan District, Shenzhen China <Signature> Name: Abigail Luo Title: Business Manager Company: Arzin Motocam Intelligent Co., Ltd

External Photos

M/N: R1 M/N: R1 M/N: R1 M/N: R1

ID Label/Location Info

FCC ID LABEL: Label Location: FCC ID: 2AS8F-R1 Product name: Wireless Charger Model No.: R1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Long:3cm Width:1cm

RF Exposure Info

Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB200303002RFX RF EXPOSURE REPORT Compiled by: Reviewed by: Approved by: Victory Rita Xiao Sherwin Qian/ Director The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen HUAK Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. Product Name: wireless charger FCC ID: 2AS8F- R1 Trademark: N/A Model Number: R1, R2, X1, X2 Prepared For: Arzin Motocam Intelligent Co., Ltd Address: Room 222, Wan Yuan Business Building 2, Liuxian Road 2,Baoan District Shenzhen China Manufacturer: Arzin Motocam Intelligent Co., Ltd Address: Room 222, Wan Yuan Business Building 2, Liuxian Road 2,Baoan District Shenzhen China Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: Floor 1&2, Building A, No. 26 of Xinhe Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong China Sample Received Date: Mar. 10, 2020 Sample tested Date: Mar. 10, 2020 to Mar. 18, 2020 Issue Date: Mar. 18, 2020 Report No.: CTB200303002RFX Test Standards FCC CFR 47 part1, 1.1307(b), 1.1310 47 CFR§2.1091; 47 CFR§2.1093 Test Results PASS Remark: This is wireless charger EMF report. EMF Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com.cn Page 1 of 8 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB200303002RFX Table of Contents Page 1 . GENERAL INFORMATION 3 1.1 . Independent Operation Mode 3 1.2 . Test Supporting System 3 2 .LIST OF T EST AND MEASUREMENT I NSTRUMENTS 4 2.1 . For conducted emission at the mains terminals test 4 3. METHOD OF MEASUREMENT 5 3. 1.Applicable Standard 5 4. TEST RESULT 5 4.1. Conducted Emission at the Mains Terminals Test 5 4.2. Equipment Approval Considerations: 6 4.3. E and H field Strength 6 5. Photographs of test set-up 8 EMF Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com.cn Page 2 of 8 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB200303002RFX 1. GENERAL INFORMATION 1.1. Independent Operation Mode The basic operation mode is: 1.1.1. wireless charger power: 15W 1.2. Test Supporting System Adapter Description : Adapter Model No. : HKA03612030-7B Power Input : AC100-240V~ 1.0A 50/60Hz Output: 12V 3A DC Line : Unshielded, Detachable 0.2m Mobile phone Model No. : IPHONE 11 EMF Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com.cn Page 3 of 8 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB200303002RFX 2.LIST OF TEST AND MEASUREMENT INSTRUMENTS 2.1. For conducted emission at the mains terminals test Item Equipment Brand Model No. Frequency Range Last calibration Calibrated until 1 Broadband Field Meter NARDA NBM-550 - Nov. 02, 2019 Nov. 01, 2020 2 Magnetic Field Meter NARDA ELT-400 1 – 400kHz Nov. 02, 2019 Nov. 01, 2020 3 Magnetic Probe NARDA HF-3061 300kHz – 30MHz Nov. 02, 2019 Nov. 01, 2020 4 Magnetic Probe NARDA HF-0191 27 – 1000MHz Nov. 02, 2019 Nov. 01, 2020 5 Broadband Field Meter NARDA NBM-550 - Nov. 02, 2019 Nov. 01, 2020 6 Electric Field Meter COMBINOV A EFM 200 5Hz – 400kHz Nov. 02, 2019 Nov. 01, 2020 7 E- Field Probe NARDA EF-0391 100kHz – 3GHz Nov. 02, 2019 Nov. 01, 2020 8 E- Field Probe NARDA EF-6091 100MHz – 60GHz Nov. 02, 2019 Nov. 01, 2020 EMF Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com.cn Page 4 of 8 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB200303002RFX 3. METHOD OF MEASUREMENT 3. 1.Applicable Standard According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1093 RF exposure is calculated. According KDB680106 D01v03: RF Exposure Wireless Charging Apps v02. 4. TEST RESULT 4.1. Conducted Emission at the Mains Terminals Test Note: Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device Test Procedure: a) The RF exposure test was performed on 360 degree turn table in anechoic chamber. b) The measurement probe was placed at test distance (15cm) which is between the edge of the charger and the geometric centre of probe. c) The turn table was rotated 360d degree to search of highest strength. d) The highest emission level was recorded and compared with limit as soon as measurement of each points were completed. e) The EUT were measured according to the dictates of KDB 680106D01v03. EMF Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com.cn Page 5 of 8 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB200303002RFX 4.2. Equipment Approval Considerations: The EUT does comply with item 5(b) of KDB 680106 D01v03 1) Power transfer frequency is less than 1MHz Ye s , the device operate in the frequency range from 111.5 KHz to 205 KHz 2) Output power from each primary coil is less than or equal to 15 watts. Ye s , the maximum output power of the primary coil is 15W. 3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that able to detect and allow coupling onlybetween individual pair of coils. Ye s , the transfer system includes only single primary and secondary coils. 4) Client device is inserted in or placed directly in contact with the transmitter. Ye s , client device is placed directly in contact with the transmitter. 5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). Ye s , the EUT is a Mobile Wireless Charger 6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Ye s , the EUT field strength levels are 50%…

Text truncated - open the document above for the full version.

Test Setup Photos

M/N: R1 Radiated Emission test M/N: R1 M/N: R1 Conducted Emission test

Contact Information

Applicant

Abigail Luo
[email protected]0755-27269223Fax: N/A

Test Firm

Shenzhen CTB Testing Technology Co., Ltd.Rita Xiao
[email protected]86-13538218145

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1115 MHz - 0.205 MHz-
Confidentiality
Long Term