
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC ID:2AS9DTAPIO3 1#Adapter:RC0653-2402500CU: FCC ID:2AS9DTAPIO3 2#Adapter:P240W2500UG: FCC ID:2AS9DTAPIO3 FCC ID:2AS9DTAPIO3 FCC ID:2AS9DTAPIO3 FCC ID:2AS9DTAPIO3
FCC ID:2AS9DTAPIO3 FCC ID:2AS9DTAPIO3
Shenzhen Huaxia Testing Technology Co., Ltd 1F., Block A of Tongsheng Technology Building,Huahui Road, Dalang Street, Longhua District, Shenzhen, China Telephone: +86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com Report Template Version: V04 Repor tTemplate Revision Date: 2018-07-06 RF Exposure Evaluation Report The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full. Report No.:CQASZ20200600469E-02 Applicant:GuangDong Substanbo Technology Co.,Ltd. Address of Applicant:Room 2508, Bd.4, Tianan yungu 2nd Industrial Park, Longgang District Shenzhen, China. Equipment Under Test (EUT): EUT Name:2.1CH SOUNDBAR SYSTEM Model No.:Tapio III Brand Name:bomaker FCC ID:2AS9DTAPIO3 Standards: 47 CFR Part 1.1307 47 CFR Part 2.1093 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt:2020-06-03 Date of Test:2020-06-03 to 2020-07-02 Date of Issue:2020-07-02 Test Result:PASS* *In the configuration tested, the EUT complied with the standards specified above Tested By: (Tom Chen) Reviewed By: (Sheek Luo) Approved By: (Jack Ai) Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200600469E-02 Page: 2 of 6 1Version Revision History Of Report ReportNo.Version Description Issue Date CQASZ20200600469E-02Rev.01 Initial report 2020-07-02 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200600469E-02 Page: 3 of 6 2 Contents Page 1 VERSION......................................................................................................................................................................2 2CONTENTS..................................................................................................................................................................3 3 GENERAL INFORMATION........................................................................................................................................4 3.1 C LIENTINFORMATION................................................................................................................................................4 3.2 G ENERALDESCRIPTION OFEUT................................................................................................................................4 4 SAR EVALUATION.....................................................................................................................................................5 4.1 RF E XPOSURECOMPLIANCEREQUIREMENT..............................................................................................................5 4.1.1 Standard Requirement..................................................................................................................................5 4.1.2 Limits................................................................................................................................................................5 4.1.3 EUT RF Exposure..........................................................................................................................................6 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200600469E-02 Page: 4 of 6 3 General Information 3.1 Client Information Applicant: GuangDong Substanbo Technology Co.,Ltd. Address of Applicant: Room 2508, Bd.4, Tianan yungu 2nd Industrial Park, Longgang District Shenzhen, China. Manufacturer: Guan gDongSubstanbo TechnologyCo.,Ltd. Address of Manufacturer: Room 2508, Bd.4, Tianan yungu 2nd Industrial Park, Longgang District Shenzhen, China. Factory: Huizhou Clinav Industrial Development Limited Address of Factory: 2 nd Fool, Clinav Industrial Building, Yuanzhou Road, Shangnan Village, Yuanzhou Town, Boluo Count y,HuizhouCity,Guangdong,China 3.2 General Description of EUT Product Name:2.1CH SOUNDBAR SYSTEM Model No.: Tapio III Trade Mark:bomaker Hardware Version: SR253AD-32-80-MAIN V3.0 Software Version: SR253AD_93D4(1) Operation Frequency: 2402MHz~2480MHz Bluetooth Version: V5.0 Modulation Technique: Frequency Hopping Spread Spectrum(FHSS) Modulation Type: GFSK,π/4DQPSK, 8DPSK Number of Channel: 79 Transfer Rate:1Mbps/2Mbps/3Mbps Hopping Channel Type: Adaptive Frequency Hopping systems Sample Type: MobilePortableFix Location Test Software of EUT: MV FrequencyTool v0.2.6 (manufacturer declare) Antenna Type:PCB antenna Antenna Gain:3.38dBi Power Supply:1# Adapter: MODEL: RC0653-2402500CU INPUT: 100-240V~50/60Hz 1.5A OUTPUT: 24V 2500mA 2# Adapter: MODEL: P240W2500UG INPUT: 100-240V~50/60Hz 1.2A OUTPUT: 24V 2500mA 60W Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200600469E-02 Page: 5 of 6 4 SAR Evaluation 4.1 RF Exposure Compliance Requirement 4.1.1 Standard Requirement According to KDB447498D01 General RF Exposure Guidance v06 4.3.1. Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed below, is satisfied. 4.1.2 Limits The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)]≤3.0 for 1-g SAR and≤7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation 17 The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is≤50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion Shenzh…
Text truncated - open the document above for the full version.
Shenzhen Huaxia Testing Technology Co., Ltd 1F., Block A of Tongsheng Technology Building,Huahui Road, Dalang Street, Longhua District, Shenzhen, China Telephone: +86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com Report Template Version: V04 Report Template Revision Date: 2018-07-06 Test Report The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full. Report No.:CQASZ20200600469E-01 Applicant:GuangDong Substanbo Technology Co.,Ltd. Address of Applicant:Room 2508, Bd.4, Tianan yungu 2nd Industrial Park, Longgang District Shenzhen, China. Equipment Under Test (EUT): EUT Name:2.1CH SOUNDBAR SYSTEM Model No.:Tapio III Brand Name:bomaker FCC ID:2AS9DTAPIO3 Standards:47 CFR Part 15, Subpart C Date of Receipt:2020-06-03 Date of Test:2020-06-03 to 2020-07-02 Date of Issue:2020-07-02 Test Result:PASS* *In the configuration tested, the EUT complied with the standards specified above Tested By: (Tom Chen) Reviewed By: (Sheek Luo) Approved By: (Jack Ai) Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200600469E-01 Page: 2 of 111 1Version Revision History Of Report Report No.Version Description Issue Date CQASZ20200600469E-01Rev.01 Initial report 2020-07-02 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200600469E-01 Page: 3 of 111 2 Test Summary Test ItemTest RequirementTest methodResult Antenna Requirement 47 CFR Part 15, Subpart C Section 15.203/15.247 (c) ANSI C63.10 (2013)PASS AC Power Line Conducted Emission 47 CFR Part 15, Subpart C Section 15.207 ANSI C63.10 (2013)PASS Conducted Peak Output Power 47 CFR Part 15, Subpart C Section 15.247 (b)(1) ANSI C63.10 (2013)PASS 20dB Occupied Bandwidth 47 CFR Part 15, Subpart C Section 15.247 (a)(1) ANSI C63.10 (2013)PASS Carrier Frequencies Separation 47 CFR Part 15, Subpart C Section 15.247 (a)(1) ANSI C63.10 (2013)PASS Hopping Channel Number 47 CFR Part 15, Subpart C Section 15.247 (a)(1) ANSI C63.10 (2013)PASS Dwell Time 47 CFR Part 15, Subpart C Section 15.247 (a)(1) ANSI C63.10 (2013)PASS Pseudorandom Frequency Hopping Sequence 47 CFR Part 15, Subpart C Section 15.247(b)(4)&TCB Exclusion List (7 July 2002) ANSI C63.10 (2013)PASS Band-edge for RF Conducted Emissions 47 CFR Part 15, Subpart C Section 15.247(d) ANSI C63.10 (2013)PASS RF Conducted Spurious Emissions 47 CFR Part 15, Subpart C Section 15.247(d) ANSI C63.10 (2013)PASS Radiated Spurious emissions 47 CFR Part 15, Subpart C Section 15.205/15.209 ANSI C63.10 (2013)PASS Restricted bands around fundamental frequency (Radiated Emission) 47 CFR Part 15, Subpart C Section 15.205/15.209 ANSI C63.10 (2013)PASS Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200600469E-01 Page: 4 of 111 3 Contents Page 1 VERSION....................................................................................................................................................................2 2 TEST SUMMARY......................................................................................................................................................3 3CONTENTS................................................................................................................................................................4 4 GENERAL INFORMATION.....................................................................................................................................5 4.1 C LIENTINFORMATION...........................................................................................................................................5 4.2 G ENERALDESCRIPTION OFEUT...........................................................................................................................5 4.3 A DDITIONALINSTRUCTIONS..................................................................................................................................7 4.4 T ESTENVIRONMENT..............................................................................................................................................8 4.5 D ESCRIPTION OFSUPPORTUNITS..........................................................................................................................8 4.6 S TATEMENT OF THE MEASUREMENT UNCERTAINTY..............................................................................................9 4.7 T ESTLOCATION...................................................................................................................................................10 4.8 T ESTFACILITY.....................................................................................................................................................10 4.9 A BNORMALITIES FROMSTANDARDCONDITIONS................................................................................................10 4.10 O THERINFORMATIONREQUESTED BY THECUSTOMER......................................................................................10 4.11 E QUIPMENTLIST................................................................................................................................................. 11 5 TEST RESULTS AND MEASUREMENT DATA............................................................................................... 12 5.1 A NTENNAREQUIREMENT.................................................................................................................................... 12 5.2 C ONDUCTEDEMISSIONS......................................................................................................................................13 5.3 C ONDUCTEDPEAKOUTPUTPOWER....................................................................................................................19 5.4 20 DBOCCUPYBANDWIDTH..............................................................................................................................…
Text truncated - open the document above for the full version.
FCC ID:2AS9DTAPIO3 1 Photographs - EUT Test Setup 1.1 Radiated Emission 9kHz~30MHz: 1# Adapter:RC0653-2402500CU: 2# Adapter:P240W2500UG: FCC ID:2AS9DTAPIO3 30MHz~1GHz: 1# Adapter:RC0653-2402500CU: 2# Adapter:P240W2500UG: FCC ID:2AS9DTAPIO3 Above 1GHz: 1# Adapter:RC0653-2402500CU: 2# Adapter:P240W2500UG: FCC ID:2AS9DTAPIO3 1.2 Conducted Emission 1# Adapter:RC0653-2402500CU: 2# Adapter:P240W2500UG:
1F., Block A of Tongsheng Technology Building, · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 400.00 µW |

LCD Monitor
Equipment Class
DTS - Digital Transmission System
2.1 Channel Soundbar with Active Subwoofer
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Remote Controller
Equipment Class
DTS - Digital Transmission System
2.1CH SOUNDBAR SYSTEM
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
TWS headphone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter