FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. D2G Group LLC/
  3. 2ASCB-55ROTDIG

2ASCB-55ROTDIG55inch Indoor Floor Standing Rotary Screen All-in-one Machine, IR Touch

D2G Group LLC
55inch Indoor Floor Standing Rotary Screen All-in-one Machine, IR Touch - FCC ID 2ASCB-55ROTDIG - D2G Group LLC
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 18, 2024
Application Purpose
Original Equipment
Date of Application
Mar 18, 2024
Equipment Note
55inch Indoor Floor Standing Rotary Screen All-in-one Machine, IR Touch
Frequency Range
2412.00000000 - 2462.00000000
Company
D2G Group LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

55inch Indoor Floor Standing Rotary Screen All-in-one Machine, IR Touch USER MANUAL SKU: DF055TRB FCC ID: 2ASCB-55ROTDIG This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)this device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation. Any changes/modifications to this equipment not approved by the party responsible for compliance could void the user’s authority to operate the equipment. 2 Thank you for purchasing this product from Displays2go. It’s our mission to help you connect with the world and build your brand with products that are personalized to your needs. Your product has been manufactured with great care using only the finest quality materials and expert workmanship. Our Quality Assurance team inspects all electronics during assembly process to assure reliable operation. This product comes with a 12-month warranty. Scan the QR code to visit the product page and learn more about your warranty. Need assistance? We are available for expert advice and all of your customer service needs. Chat Us DISPLAYS2GO.COM Email Us INFO@ DISPLAYS2GO.COM Call Us 1-844-221-3388 3 T ABLE O F CONTENTS Before Use Safety Warnings and Precautions 4 Packing List 7 Interface Diagram 7 Assembly 8 How to rotate the screen direction 9 Operation Power On/Off 10 Remote Control 10 HDMI Connection 10 Navigation 11 Android 11 Quick Start Guide 11 DiViEX 12 Reference Technical Specifications 15 Cleaning and Maintenance 16 Troubleshooting Guide 17 Names and Contents of Toxic and Hazardous 19 Substances or Elements in the Product FCC Compliance Notice 20 4 Warning: May cause personal injury or death The operation is prohibited Caution: May cause damage or property loss BEFORE USE Safety Warnings and Precautions Thank you for purchasing the high-performance multi-functional LED backlight Digital Signage from Displays2Go. We have considered the factors to ensure personal safety in product design and have tested rigorously at the factory. However, improper installation and use may result in electric shock and fire. In order to safely use, maximize performance of the unit and extend the life of the product, please read and follow all instructions carefully before using the product. Keep the instructions for future reference. We strongly recommend using a surge protector, or a power strip with internal circuit breaker to prevent damages to the digital signage. If any of the following occurs: • Power outage or instable voltage. • Abnormal sound or smell from the unit. • AC power cord is damaged. • Digital Signage is damaged due to drop, knock or impact. • Any liquid or foreign matters fall into the enclosure. Turn off the Digital Signage immediately, pull out the plug from the power outlet, and ask the authorized personnel for maintenance timely. If coal gas or other flammable gas leaks, do not pull out the plug of the LCD digital signage or other electrical appliances; instead, turn off the gas valve immediately, and open the doors and windows quickly. 5 WARNING • Cut off the power supply before connecting or disconnecting any cables. • Do not place the Digital Signage on any instable positions, or else it may be damaged or cause fire. • Do not place the Digital Signage in the positions such as: • The environment subject to direct strong sunlight, moisture, extreme temperature or too much dust, • The environment with flammable or explosive materials, • The environment with flammable or corrosive gases, • Do not use damaged or inappropriate power outlets, and ensure that the plugs and outlets contact properly. • Do not let dust or metal deposits adhere to the plugs and outlets. • Do not damage the power cords: • Do not modify the power cords, • Do not place heavy objects on the power cords, • Keep the power cords away from heat source, • Do not pull the cord to remove the plug. • Do not connect too many plugs to one outlet in parallel, or else it may cause fire due to excessive power consumption. • Do not approach the Digital Signage with open flame (e.g. a lighted candle), or else it may cause electric shock or fire. • Do not put any sharp objects, metal or liquid into the vents or let them touch the signal terminals to avoid short circuit, product damage, and electric shock. • The openings in the enclosure are designed for ventilation and cooling, to ensure long time reliable running of components inside the enclosure and prevent overheating. Do not block the openings when place the unit. Do not touch the plugs with wet fingers, or else it will cause electric shock. Do not use the Digital Signage in stormy weather, especially when there is lightning, instead, please disconnect the power and antenna plugs to avoid lightning strike. Do not disassemble the Digital Signage without permission, or else it may cause electric shock or fire. Please ask qualified technician for repair. 6 CAUTION • Do not let children climb onto the Digital Signage. • Keep the small parts away from children to prevent them from swallowing. • If the Digital Signage won’t be used for a long time, please turn it off and pull out the power plug. • To adjust the position of the Digital Signage, please disconnect all power cords and move slowly to avoid tip over. • Do not scratch or knock the LCD with hard object, or twist and squeeze the LCD. • Do not turn on the unit immediately when it is moved from a place with low temperature to high temperature, or else it will cause condensation and malfunction. • Before cleaning the Digital Signage, please pull out the power plug, wipe with soft cloth, do not use industrial chemicals, prevent foreign matters from entering the machine. Improper cleaning (such as cleaning solution, water) may damage the product, erase the printed information, and even cause damage of the components if fluid flows in, resulting in machine failure. • If the unit displays t…

Text truncated - open the document above for the full version.

Attestation Statements

-D2GGroupLLC- FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 3/14/24 U.S.AgentDesignation [D2GGroupLLC]acknowledgestheirconsentforthefollowingcontactlocatedintheUnitedStatestoactas theiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCCID:2ASCB- 55ROTDIG): NameandcompanyofU.S.agent:D2GGroupLLC PhysicalU.S.addressofagent:81CommerceDrive,FallRiver,Massachusetts,02720,UnitedStates FRNofU.S.agent:0028157329 EmailaddressofU.S.agent:[email protected] [D2GGroupLLC]acknowledgestheirobligationtoacceptserviceofprocessonbehalfof[D2GGroupLLC]. [D2GGroupLLC]withtheFRN[0028157329]acceptsitsobligationtomaintainanagentforserviceofprocess intheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminatedallmarketing andimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission-related administrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature [RodWashington] [VP,Merchandising] [D2GGroupLLC] Signature [RodWashington] [VP,Merchandising] [D2GGroupLLC] 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5

Attestation Statements

-D2GGroupLLC- TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB986446D01. FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 3/14/24 Towhomitmayconcern: We,[D2GGroupLLC],herebycertifythattheequipmentforwhichauthorizationissought(FCCID: 2ASCB-55ROTDIG)isnot“covered”equipmentprohibitedfromreceivinganequipmentauthorization pursuantto§2.903oftheFCCrules. Wealsocertifythat,asofthedateofthefilingoftheapplication,wearenotidentifiedontheCovered List(https://www.fcc.gov/supplychain/coveredlist)asanentityproducing“covered”equipment. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirements listedunder§2.911(b)and(d)(5)and(6). Sincerely, Signature [RodWashington] [VP,Merchandising] [D2GGroupLLC] 6 2 _ [ m o d e l ] C o v e r e d E q u _ 2 . 9 1 1 ( d ) ( 5 ) ( i ) a n d ( i i ) - U , V 0 2

External Photos

ProjectNo.:18220WC400260Page 1 of 7 AppendixII--ExternalPhotograph ProjectNo.:18220WC400260Page 2 of 7 ProjectNo.:18220WC400260Page 3 of 7 ProjectNo.:18220WC400260Page 4 of 7 ProjectNo.:18220WC400260Page 5 of 7 ProjectNo.:18220WC400260Page 6 of 7 ANT: ProjectNo.:18220WC400260Page 7 of 7

ID Label/Location Info

Model: DF055TRB 55inch Indoor Floor Standing Rotary 2ASCB-55ROTDIG Rated Voltage: AC 100-240V Rated Current: 0.7-1.5A Rated Frequency: 50/60Hz Max Power Consumption: 120W This device complies with Part 15 of the FCC Rules. Operation is subject to the Made in China following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes/modifications to this equipment not approved by the party responsible for compliance could void the user’s authority to operate the equipment. D2G GROUP LLC 81 Commerce Drive, Fall River, MA 02720 Contains FCC ID: www.displays2go.com 1-844-221-3393 CAUTION / PRUDENCE RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ÉLECTRIQUE NE PAS OUVRIR Screen All-in-one Machine, IR Touch

RF Exposure Info

MAXIMUMPERMISSIBLEEXPOSURE KDB447498D01MobileandPortableDevicesRFExposureProceduresand EquipmentAuthorizationPoliciesv06. AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeused toevaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF) Radiationasspecifiedin§1.1307(b) EUTSpecification FCCID2ASCB-55ROTDIG EUT55inchIndoorFloorStandingRotaryScreenAll-in-one Machine,IRTouch Frequencyband (Operating) BT:2.402GHz~2.480GH WLAN:2.412GHz~2.462GHz RLAN:5.180GHz~5.240GHz RLAN:5.260GHz~5.320GHz RLAN:5.500GHz~5.700GHz RLAN:5.745GHz~5.825GHz Others: Devicecategory Portable(<20cmseparation) Mobile(>20cmseparation) Others___ Exposureclassification Occupational/Controlledexposure GeneralPopulation/Uncontrolledexposure Antennadiversity Singleantenna Multipleantennas Txdiversity Rxdiversity Tx/Rxdiversity Max.outputpower BLE:8.53dBm(0.0071W) WiFi2.4G:16.46dBm(0.0443W) WiFi5.2G:21.66dBm(0.1466W) WiFi5.3G:16.44dBm(0.0441W) WiFi5.6G:16.92dBm(0.0492W) WiFi5.8G:16.73dBm(0.0471W) Antennagain(Max) BLE:4.92dBi WiFi2.4G:4.92dBi WiFi5.2G:5.06dBi WiFi5.3G:5.17dBi WiFi5.6G:5.21dBi WiFi5.8G:5.28dBi Evaluationapplied MPEEvaluation SAREvaluation LimitsforMaximumPermissibleExposure(MPE) Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm 2 ) Average Time (A)LimitsforOccupational/ControlExposures 300-1500----F/3006 1500-100000----56 (B)LimitsforGeneralPopulation/UncontrolExposures 300-1500----F/150030 1500-100000----130 Friistransmissionformula:Pd=(Pout*G)\(4*pi*R2) Where Pd=PowerdensityinmW/cm 2 Pout=outputpowertoantennainMw G=gainofantennainlinearscale Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorincm PdthelimitofMPE.Ifweknowthemaximumgainoftheantennaandtotal powerinputtotheantenna,throughthecalculation,wewillknowthedistance wheretheMPElimitisreached. MaxMeasurementResult OperatingMode Measured Power Tuneup tolerance Max.Tune upPower Antenna Gain Powerdensity at20cm Powerdensity Limits (mW/cm 2 ) (dBm)(dBm)(dBm)(dBi)(mW/cm 2 ) BLE8.538.53±19.534.920.00551 WiFi2.4G16.4616.46±117.464.920.03441 WiFi5.2G21.6621.66±122.665.060.11771 WiFi5.3G16.4416.44±117.445.170.03631 WiFi5.6G16.9216.92±117.925.210.04091 WiFi5.8G16.7316.73±117.735.280.03981 Theratioscannotsimultaneoustransmission. Result:NoStandaloneSARtestisrequired.

Test Report

Page1of22 AppendixTestData ReportNo.:18220WC40026001TestSampleNo.:1-2-2 StartTestDate:2024.2.27FinishTestDate:2024.2.27 TestEngineer:Auditor: Temperature:25.3 °C RelativeHumidity:48% Pressure:101kPa AppendixA:DTSBandwidth TestResult TestModeAntennaFrequency[MHz] DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24020.6842401.6402402.3240.5PASS 24400.7242439.6242440.3480.5PASS 24800.6722479.6562480.3280.5PASS Page2of22 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page3of22 Page4of22 AppendixB:OccupiedChannelBandwidth TestResult TestModeAntennaFrequency[MHz]OCB[MHz]FL[MHz]FH[MHz] BLE_1MAnt1 24021.03282401.47092402.5037 24401.04272439.46562440.5083 24801.02542479.46912480.4945 Page5of22 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page6of22 Page7of22 AppendixC:Maximumconductedoutputpower TestResultPeak TestModeAntennaFrequency[MHz] ConductedPeak Power[dBm] Conducted Limit[dBm] Verdict BLE_1MAnt1 24028.36≤30PASS 24408.53≤30PASS 24807.85≤30PASS Page8of22 TestGraphsPeak BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page9of22 Page10of22 AppendixD:Maximumpowerspectraldensity TestResult TestModeAntennaFrequency[MHz]Result[dBm/3kHz]Limit[dBm/3kHz]Verdict BLE_1MAnt1 2402-7.87≤8.00PASS 2440-6.80≤8.00PASS 2480-7.82≤8.00PASS Page11of22 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page12of22 Page13of22 AppendixE:Bandedgemeasurements TestResult TestModeAntennaChName Frequency [MHz] RefLevel[dBm]Result[dBm]Limit[dBm]Verdict BLE_1MAnt1 Low24026.99-48.62≤-13.02PASS High24807.16-56.58≤-12.84PASS Page14of22 TestGraphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 Page15of22 AppendixF:ConductedSpuriousEmission TestResult TestModeAntenna Frequency [MHz] FreqRange [MHz] RefLevel [dBm] Result[dBm]Limit[dBm]Verdict BLE_1MAnt1 2402 Reference6.826.82---PASS 30~10006.82-66.83≤-13.18PASS 1000~265006.82-42.76≤-13.18PASS 2440 Reference7.157.15---PASS 30~10007.15-66.37≤-12.85PASS 1000~265007.15-40.94≤-12.85PASS 2480 Reference5.965.96---PASS 30~10005.96-67.02≤-14.04PASS 1000~265005.96-51.3≤-14.04PASS Page16of22 TestGraphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 Page17of22 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 Page18of22 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference BLE_1M_Ant1_2480_30~1000 Page19of22 BLE_1M_Ant1_2480_1000~26500 Page20of22 AppendixG:DutyCycle TestResult TestModeAntennaFrequency[MHz] ONTime [ms] Period [ms] DutyCycle [%] DutyCycle Factor[dB] BLE_1MAnt1 24022.132.5085.200.70 24402.132.5085.200.70 24802.132.5085.200.70 Page21of22 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page22of22 ---end---

Test Report

ReportNo.:18220WC40026001FCCID:2ASCB-55ROTDIGPage1of30 FCCTestReport Applicant:D2GGroupLLC Address: 81CommerceDrive,FallRiver,Massachusetts, 02720,UnitedStates ProductName: 55inchIndoorFloorStandingRotaryScreenAll- in-oneMachine,IRTouch ReportDate:Mar.14,2024 ShenzhenAnbotekComplianceLaboratoryLimited ReportNo.:18220WC40026001FCCID:2ASCB-55ROTDIGPage2of30 Contents 1.GeneralInformation.................................................................................................................................6 1.1.ClientInformation...........................................................................................................................6 1.2.DescriptionofDevice(EUT)..........................................................................................................6 1.3.AuxiliaryEquipmentUsedDuringTest..........................................................................................7 1.4.Operationchannellist....................................................................................................................7 1.5.DescriptionofTestModes.............................................................................................................7 1.6.MeasurementUncertainty.............................................................................................................8 1.7.TestSummary................................................................................................................................8 1.8.DescriptionofTestFacility.............................................................................................................9 1.9.Disclaimer......................................................................................................................................9 1.10.TestEquipmentList...................................................................................................................10 2.Antennarequirement..............................................................................................................................12 2.1.Conclusion...................................................................................................................................12 3.ConductedEmissionatACpowerline..................................................................................................13 3.1.EUTOperation.............................................................................................................................13 3.2.TestSetup....................................................................................................................................13 3.3.TestData......................................................................................................................................14 4.OccupiedBandwidth..............................................................................................................................16 4.1.EUTOperation.............................................................................................................................16 4.2.TestSetup....................................................................................................................................16 4.3.TestData......................................................................................................................................16 5.MaximumConductedOutputPower......................................................................................................17 5.1.EUTOperation.............................................................................................................................17 5.2.TestSetup....................................................................................................................................17 5.3.TestData......................................................................................................................................17 6.PowerSpectralDensity..........................................................................................................................18 6.1.EUTOperation.............................................................................................................................18 6.2.TestSetup....................................................................................................................................18 6.3.TestData......................................................................................................................................18 7.Emissionsinnon-restrictedfrequencybands.......................................................................................19 7.1.EUTOperation.............................................................................................................................19 7.2.TestSetup....................................................................................................................................19 7.3.TestData......................................................................................................................................19 8.Bandedgeemissions(Radiated)..........................................................................................................20 8.1.EUTOperation.............................................................................................................................20 8.2.TestSetup....................................................................................................................................20 8.3.TestData......................................................................................................................................21 9.Emissionsinfrequencybands(below1GHz).......................................................................................22 9.1.EUTOperation.............................................................................................................................22 9.2.TestSetup......................…

Text truncated - open the document above for the full version.

Test Report

Page1of75 AppendixTestData ReportNo.:18220WC40026002TestSampleNo.:1-2-2 StartTestDate:2024.2.26FinishTestDate:2024.2.27 TestEngineer:Auditor: Temperature:25.3 °C RelativeHumidity:48% Pressure:101kPa AppendixA:DTSBandwidth TestResult TestModeAntennaFrequency[MHz] DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt1 24127.6402408.2002415.8400.5PASS 24378.0802432.9202441.0000.5PASS 24627.8002457.9602465.7600.5PASS 11GAnt1 241216.5602403.7202420.2800.5PASS 243716.4802428.7202445.2000.5PASS 246216.5202453.7202470.2400.5PASS 11N20SISOAnt1 241217.6002403.2002420.8000.5PASS 243717.6402428.1602445.8000.5PASS 246217.6802453.1202470.8000.5PASS 11N40SISOAnt1 242236.3202403.8402440.1600.5PASS 243735.4402418.8402454.2800.5PASS 245236.5602433.6802470.2400.5PASS 11AX20SISOAnt1 241219.0002402.5202421.5200.5PASS 243718.8802427.4802446.3600.5PASS 246219.0402452.4402471.4800.5PASS 11AX40SISOAnt1 242237.9202402.8802440.8000.5PASS 243737.8402417.9602455.8000.5PASS 245237.7602433.1202470.8800.5PASS Page2of75 TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page3of75 11G_Ant1_2412 11G_Ant1_2437 Page4of75 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 Page5of75 11N20SISO_Ant1_2462 11N40SISO_Ant1_2422 Page6of75 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 11AX20SISO_Ant1_2412 Page7of75 11AX20SISO_Ant1_2437 11AX20SISO_Ant1_2462 Page8of75 11AX40SISO_Ant1_2422 11AX40SISO_Ant1_2437 11AX40SISO_Ant1_2452 Page9of75 Page10of75 AppendixB:OccupiedChannelBandwidth TestResult TestModeAntenna Channel Frequency[MHz] OCB [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt1 241212.1202405.95972418.0797------ 243712.1392430.91302443.0520------ 246212.1392455.94502468.0840------ 11GAnt1 241217.4832403.24982420.7328------ 243717.4712428.20692445.6779------ 246217.4792453.28662470.7656------ 11N20SISOAnt1 241218.4132402.81772421.2307------ 243718.3942427.76362446.1576------ 246218.3722452.80392471.1759------ 11N40SISOAnt1 242236.4962403.75102440.2470------ 243736.6512418.67032455.3213------ 245236.7082433.62192470.3299------ 11AX20SISOAnt1 241219.3212402.38002421.7010------ 243719.2312427.36892446.5999------ 246219.3212452.33142471.6524------ 11AX40SISOAnt1 242237.9272403.06002440.9870------ 243737.9812418.00742455.9884------ 245238.0572432.95762471.0146------ Page11of75 TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page12of75 11G_Ant1_2412 11G_Ant1_2437 Page13of75 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 Page14of75 11N20SISO_Ant1_2462 11N40SISO_Ant1_2422 Page15of75 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 11AX20SISO_Ant1_2412 Page16of75 11AX20SISO_Ant1_2437 11AX20SISO_Ant1_2462 Page17of75 11AX40SISO_Ant1_2422 11AX40SISO_Ant1_2437 11AX40SISO_Ant1_2452 Page18of75 Page19of75 AppendixC:Maximumconductedoutputpower TestResult TestModeAntennaFrequency[MHz] AverageOutput Power[dBm] Conducted Limit[dBm] 11BAnt1 241215.41≤30.00 243716.46≤30.00 246213.64≤30.00 11GAnt1 241215.26≤30.00 243715.54≤30.00 246215.83≤30.00 11N20SISOAnt1 241215.62≤30.00 243715.64≤30.00 246215.81≤30.00 11N40SISOAnt1 242215.11≤30.00 243715.48≤30.00 245214.80≤30.00 11AX20SISOAnt1 241216.36≤30.00 243716.31≤30.00 246216.39≤30.00 11AX40SISOAnt1 242215.72≤30.00 243715.84≤30.00 245215.31≤30.00 Note:TheDutyCycleFactor(10*log(1/D))andcablelossarecompensatedinthegraph. Page20of75 TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page21of75 11G_Ant1_2412 11G_Ant1_2437 Page22of75 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 Page23of75 11N20SISO_Ant1_2462 11N40SISO_Ant1_2422 Page24of75 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 11AX20SISO_Ant1_2412 Page25of75 11AX20SISO_Ant1_2437 11AX20SISO_Ant1_2462 Page26of75 11AX40SISO_Ant1_2422 11AX40SISO_Ant1_2437 11AX40SISO_Ant1_2452 Page27of75 Page28of75 AppendixD:Maximumpowerspectraldensity TestResult TestModeAntenna Frequency [MHz] Result [dBm/30kHz] Result [dBm/3kHz] Limit [dBm/3kHz] Verdict 11BAnt1 2412-7.06-17.06≤8.00PASS 2437-6.12-16.12≤8.00PASS 2462-9.79-19.79≤8.00PASS 11GAnt1 2412-14.60-24.60≤8.00PASS 2437-13.63-23.63≤8.00PASS 2462-13.82-23.82≤8.00PASS 11N20SISOAnt1 2412-14.72-24.72≤8.00PASS 2437-14.12-24.12≤8.00PASS 2462-14.48-24.48≤8.00PASS 11N40SISOAnt1 2422-18.00-28.00≤8.00PASS 2437-17.43-27.43≤8.00PASS 2452-18.67-28.67≤8.00PASS 11AX20SISOAnt1 2412-15.73-25.73≤8.00PASS 2437-14.81-24.81≤8.00PASS 2462-16.14-26.14≤8.00PASS 11AX40SISOAnt1 2422-19.51-29.51≤8.00PASS 2437-19.14-29.14≤8.00PASS 2452-20.53-30.53≤8.00PASS Note: 1.TheDutyCycleFactor(10*log(1/D))andcablelossarecompensatedinthegraph. 2.PSD(dBm/3kHz)=PSD(dBm/30kHz)-(10*log(30/3)) Page29of75 TestGraphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page30of75 11G_Ant1_2412 11G_Ant1_2437 Page31of75 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 Page32of75 11N20SISO_Ant1_2462 11N40SISO_Ant1_2422 Page33of75 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 11AX20SISO_Ant1_2412 Page34of75 11AX20SISO_Ant1_2437 11AX20SISO_Ant1_2462 Page35of75 11AX40SISO_Ant1_2422 11AX40SISO_Ant1_2437 11AX40SISO_Ant1_2452 Page36of75 Page37of75 AppendixE:Bandedgemeasurements TestResult TestModeAntennaChName Frequency [MHz] RefLevel [dBm] Result[dBm]Limit[dBm]Verdict 11BAnt1 Low24125.01-49.2≤-24.99PASS High24622.60-53.97≤-27.4PASS 11GAnt1 Low24120.25-42.71≤-29.75PASS High2462-0.35-48.96≤-30.35PASS 11N20SISOAnt1 Low24120.56-38.98≤-29.44PASS High2462-1.08-49.23≤-31.08PASS 11N40SISOAnt1 Low2422-3.64-47.49≤-33.64PASS High2452-4.71-51.14≤-34.71PASS 11AX20SISOAnt1 Low2412-0.09-39.35≤-30.09PASS High2462-1.40-47.96≤-31.4PASS 11AX40SISOAnt1 Low2422-3.90-44.87≤-33.9PASS High2452-3.86-50.59≤-33.86PASS Page38of75 TestGraphs 11B_Ant1_Low_2412 11B_Ant1_High_2462 11G_Ant1_Low_2412 Page39of75 11G_Ant1_High_2462 11N20SISO_Ant1_Low_2412 Page40of75 11N20SISO_Ant1_High_2462 11N40SISO_Ant1_Low_2422 11N40SISO_Ant1_High_2452

Test Report

Page41of75 11AX20SISO_Ant1_Low_2412 11AX20SISO_Ant1_High_2462 Page42of75 11AX40SISO_Ant1_Low_2422 11AX40SISO_Ant1_High_2452 Page43of75 AppendixF:ConductedSpuriousEmission TestResult TestModeAntennaFrequency[MHz] FreqRange [Mhz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 11BAnt1 2412 Reference3.293.29---PASS 30~10003.29-66.53≤-26.71PASS 1000~265003.29-50.64≤-26.71PASS 2437 Reference1.861.86---PASS 30~10001.86-66.46≤-28.14PASS 1000~265001.86-51.44≤-28.14PASS 2462 Reference1.121.12---PASS 30~10001.12-67.35≤-28.88PASS 1000~265001.12-51.43≤-28.88PASS 11GAnt1 2412 Reference-2.31-2.31---PASS 30~1000-2.31-66.81≤-32.31PASS 1000~26500-2.31-52.58≤-32.31PASS 2437 Reference-3.09-3.09---PASS 30~1000-3.09-66.38≤-33.09PASS 1000~26500-3.09-52.65≤-33.09PASS 2462 Reference-2.39-2.39---PASS 30~1000-2.39-66.35≤-32.39PASS 1000~26500-2.39-51.49≤-32.39PASS 11N20SISOAnt1 2412 Reference-3.23-3.23---PASS 30~1000-3.23-66.13≤-33.23PASS 1000~26500-3.23-52.41≤-33.23PASS 2437 Reference-2.76-2.76---PASS 30~1000-2.76-67.14≤-32.76PASS 1000~26500-2.76-52.55≤-32.76PASS 2462 Reference-2.06-2.06---PASS 30~1000-2.06-65.69≤-32.06PASS 1000~26500-2.06-51.56≤-32.06PASS 11N40SISOAnt1 2422 Reference-5.94-5.94---PASS 30~1000-5.94-66.03≤-35.94PASS 1000~26500-5.94-52.56≤-35.94PASS 2437 Reference-2.56-2.56---PASS 30~1000-2.56-66.55≤-32.56PASS 1000~26500-2.56-52.09≤-32.56PASS 2452 Reference-5.18-5.18---PASS 30~1000-5.18-65.44≤-35.18PASS 1000~26500-5.18-50.44≤-35.18PASS 11AX20SISOAnt12412Reference-2.00-2.00---PASS Page44of75 30~1000-2.00-67.17≤-32PASS 1000~26500-2.00-52.21≤-32PASS 2437 Reference-2.44-2.44---PASS 30~1000-2.44-67.81≤-32.44PASS 1000~26500-2.44-52.45≤-32.44PASS 2462 Reference-2.69-2.69---PASS 30~1000-2.69-65.95≤-32.69PASS 1000~26500-2.69-51.98≤-32.69PASS 11AX40SISOAnt1 2422 Reference-5.20-5.20---PASS 30~1000-5.20-65.64≤-35.2PASS 1000~26500-5.20-53.07≤-35.2PASS 2437 Reference-5.24-5.24---PASS 30~1000-5.24-66.33≤-35.24PASS 1000~26500-5.24-52.36≤-35.24PASS 2452 Reference-6.36-6.36---PASS 30~1000-6.36-66.45≤-36.36PASS 1000~26500-6.36-51.21≤-36.36PASS Page45of75 TestGraphs 11B_Ant1_2412_0~Reference 11B_Ant1_2412_30~1000 11B_Ant1_2412_1000~26500 Page46of75 11B_Ant1_2437_0~Reference 11B_Ant1_2437_30~1000 Page47of75 11B_Ant1_2437_1000~26500 11B_Ant1_2462_0~Reference 11B_Ant1_2462_30~1000 Page48of75 11B_Ant1_2462_1000~26500 11G_Ant1_2412_0~Reference Page49of75 11G_Ant1_2412_30~1000 11G_Ant1_2412_1000~26500 11G_Ant1_2437_0~Reference Page50of75 11G_Ant1_2437_30~1000 11G_Ant1_2437_1000~26500 Page51of75 11G_Ant1_2462_0~Reference 11G_Ant1_2462_30~1000 11G_Ant1_2462_1000~26500 Page52of75 11N20SISO_Ant1_2412_0~Reference 11N20SISO_Ant1_2412_30~1000 Page53of75 11N20SISO_Ant1_2412_1000~26500 11N20SISO_Ant1_2437_0~Reference 11N20SISO_Ant1_2437_30~1000 Page54of75 11N20SISO_Ant1_2437_1000~26500 11N20SISO_Ant1_2462_0~Reference Page55of75 11N20SISO_Ant1_2462_30~1000 11N20SISO_Ant1_2462_1000~26500 11N40SISO_Ant1_2422_0~Reference Page56of75 11N40SISO_Ant1_2422_30~1000 11N40SISO_Ant1_2422_1000~26500 Page57of75 11N40SISO_Ant1_2437_0~Reference 11N40SISO_Ant1_2437_30~1000 11N40SISO_Ant1_2437_1000~26500 Page58of75 11N40SISO_Ant1_2452_0~Reference 11N40SISO_Ant1_2452_30~1000 Page59of75 11N40SISO_Ant1_2452_1000~26500 11AX20SISO_Ant1_2412_0~Reference 11AX20SISO_Ant1_2412_30~1000 Page60of75 11AX20SISO_Ant1_2412_1000~26500 11AX20SISO_Ant1_2437_0~Reference Page61of75 11AX20SISO_Ant1_2437_30~1000 11AX20SISO_Ant1_2437_1000~26500 11AX20SISO_Ant1_2462_0~Reference Page62of75 11AX20SISO_Ant1_2462_30~1000 11AX20SISO_Ant1_2462_1000~26500 Page63of75 11AX40SISO_Ant1_2422_0~Reference 11AX40SISO_Ant1_2422_30~1000 11AX40SISO_Ant1_2422_1000~26500 Page64of75 11AX40SISO_Ant1_2437_0~Reference 11AX40SISO_Ant1…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Rod Washington(VP, Merchandising)
[email protected]5086897117Fax: 888-875-4507

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedJeff Zhu
[email protected]13798230942

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz44.30 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. This device supports 20 and 40MHz bandwidth operation.

Other Applications from D2G Group LLC

2ASCB-DP015TLW14

15.6inch Digital Touch Portable

Sep 04, 2026

Equipment Class

DTS - Digital Transmission System
2ASCB-DDNT55SP14

55inch Digital Signage Floor Standing 2-Sided

Sep 04, 2026

Equipment Class

DTS - Digital Transmission System
55-inch NoTCH WALL MOUNTED AND 14 OS DUAL BAND - FCC ID 2ASCB-DH055NLB - D2G Group LLC
2ASCB-DH055NLB

55-inch NoTCH WALL MOUNTED AND 14 OS DUAL BAND

Jul 27, 2026

Equipment Class

DTS - Digital Transmission System
24-inch Outdoor PCAP TCH Battery Operated BLK 14 OS - FCC ID 2ASCB-DW024CLB - D2G Group LLC
2ASCB-DW024CLB

24-inch Outdoor PCAP TCH Battery Operated BLK 14 OS

Jul 22, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
2ASCB-55ROTDIG14

55inch Floor Standing Digital Signage Rotating Screen

Jul 17, 2026

Equipment Class

DTS - Digital Transmission System