FCC ID:2ASE9-ZMCSBM01 Test mode No.: ZCSLASC01 FCC ID:2ASE9-ZMCSBM01 FCC ID:2ASE9-ZMCSBM01 FCC ID:2ASE9-ZMCSBM01
FCC ID:2ASE9-ZMCSBM01 FCC ID:2ASE9-ZMCSBM01 FCC ID:2ASE9-ZMCSBM01
Shenzhen Huaxia Testing Technology Co., Ltd 1F., Block A of Tongsheng Technology Building,Huahui Road, Dalang Street, Longhua District, Shenzhen, China Telephone: +86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com Report Template Version: V03 Report Template Revision Date: Mar.1st, 2017 Test Report * In the configuration tested, the EUT complied with the standards specified above. The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full. Report No.: CQASZ20190800701E-01 Applicant:Zeos India Pvt. Ltd Address of Applicant:Plot No. 394, Road No. 81 Jubilee Hills, Hyderabad - 500033 Telangana, India Equipment Under Test (EUT): Product: ZEOS Smart Battery Module Model No.: ZMCSBM01 Brand Name: Zeos FCC ID:2ASE9-ZMCSBM01 Standards:47 CFR Part 15, Subpart C Date of Receipt:2019-08-13 Date of Test:2019-08-19 to 2019-08-27 Date of Issue:2019-08-28 Test Result :PASS* Tested By: (Tom Chen) Reviewed By: (SheekLuo) Approved By: ( Jack Ai) Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20190800701E-01 Page: 2 of 28 1Version Revision History Of Report ReportNo.Version Description Issue Date CQASZ20190800701E-01Rev.01 Initial report 2019-08-28 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20190800701E-01 Page: 3 of 28 2 Test Summary Test ItemTest RequirementTest methodResult Antenna Requirement 47 CFR Part 15, Subpart C Section 15.203 ANSI C63.10 2013PASS AC Power Line Conducted Emission 47 CFR Part 15, Subpart C Section 15.207 ANSI C63.10 2013PASS 20dB Occupied Bandwidth 47 CFR Part 15, Subpart C Section 15.215 ANSI C63.10 2013PASS Radiated Emission , Radiated Spurious Emissions 47 CFR Part 15, Subpart C Section 15.209 ANSI C63.10 2013PASS Remark: The tested sample(s) and the sample information are provided by the client. Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20190800701E-01 Page: 4 of 28 3 Contents Page 1 VERSION....................................................................................................................................................................2 2 TEST SUMMARY......................................................................................................................................................3 3CONTENTS................................................................................................................................................................4 4 GENERAL INFORMATION.....................................................................................................................................5 4.1 C LIENTINFORMATION...........................................................................................................................................5 4.2 G ENERALDESCRIPTION OFEUT........................................................................................................................5 4.3 T ESTENVIRONMENT.............................................................................................................................................6 4.4 D ESCRIPTION OFSUPPORTUNITS......................................................................................................................6 4.5 S TATEMENT OF THE MEASUREMENT UNCERTAINTY............................................................................................7 4.6 T ESTLOCATION....................................................................................................................................................7 4.7 T ESTFACILITY......................................................................................................................................................7 4.8 D EVIATION FROMSTANDARDS.............................................................................................................................7 4.9 O THERINFORMATIONREQUESTED BY THECUSTOMER....................................................................................7 4.10 E QUIPMENTLIST...................................................................................................................................................8 5 TEST RESULTS AND MEASUREMENT DATA.................................................................................................9 5.1 A NTENNAREQUIREMENT.....................................................................................................................................9 5.2 C ONDUCTEDEMISSIONS....................................................................................................................................10 5.3 20 DBOCCUPYBANDWIDTH..............................................................................................................................13 5.4 R ADIATEDSPURIOUSEMISSION&RESTRICTED BANDS..................................................................................15 5.4.1 Spurious Emissions.................................................................................................................................15 6 PHOTOGRAPHS - EUT TEST SETUP...............................................................................................................20 6.1 R ADIATEDEMISSION..........................................................................................................................................20 6.2 C ONDUCTEDEMISSION......................................................................................................................................21 7 PHOTOGRAPHS - EUT CONSTRUCTIONAL DETAILS................................................................................22 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20190800701E-01 Page: 5 of 28 4 General Information 4.1 Client Information Applicant: Zeos India Pvt. Ltd Address of Applicant: PlotNo.394,RoadNo.81 Jubilee Hills, Hyderabad - 50…
Text truncated - open the document above for the full version.
Shenzhen Huaxia Testing Technology Co., Ltd 1F., Block A of Tongsheng Technology Building,Huahui Road, Dalang Street, Longhua District, Shenzhen, China Telephone: +86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com Report Template Version: V03 Report Template Revision Date: Mar.1st, 2017 RF Exposure Evaluation Report * In the configuration tested, the EUT complied with the standards specified above. The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full. Report No.: CQASZ20190800701E-02 Applicant:Zeos India Pvt. Ltd Address of Applicant:PlotNo.394,RoadNo.81 Jubilee Hills, Hyderabad - 500033 Telangana, India Equipment Under Test (EUT): Product: ZEOS Smart Battery Module Model No.: ZMCSBM01 Brand Name: Zeos FCC ID:2ASE9-ZMCSBM01 Standards: 47 CFR Part 1.1307 47 CFR Part 1.1310 KDB 680106 D01 RF Exposure Wireless Charging Base App v03 Date of Receipt:2019-08-13 Date of Test:2019-08-19 to 2019-08-27 Date of Issue:2019-08-28 Test Result :PASS* Tested By: (Tom Chen) Reviewed By: (SheekLuo) Approved By: ( Jack Ai) Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20190800701E-02 Page: 2 of 11 1Version Revision History Of Report ReportNo.Version Description Issue Date CQASZ20190800701E-02Rev.01 Initial report 2019-08-28 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20190800701E-02 Page: 3 of 11 2 Contents Page 1 VERSION ...................................................................................................................................................................... 2 2CONTENTS .................................................................................................................................................................. 3 3 GENERAL INFORMATION ....................................................................................................................................... 4 3.1 C LIENTINFORMATION ................................................................................................................................................ 4 3.2 G ENERALDESCRIPTION OFEUT ............................................................................................................................. 4 3.3 T ESTENVIRONMENT ................................................................................................................................................. 5 3.4 D ESCRIPTION OFSUPPORTUNITS ........................................................................................................................... 5 3.5 T ESTLOCATION ......................................................................................................................................................... 6 3.6 T ESTFACILITY ........................................................................................................................................................... 6 3.7 E QUIPMENTLIST ........................................................................................................................................................ 6 4 RF EXPOSURE EVALUATION ................................................................................................................................ 7 4.1 RF E XPOSURECOMPLIANCEREQUIREMENT ........................................................................................................... 7 4.1.1 Limits ............................................................................................................................................................... 7 4.1.2 Test Procedure ............................................................................................................................................... 7 4.1.3 Test Setup ....................................................................................................................................................... 8 4.1.4 Test Results .................................................................................................................................................... 8 APPENDIX A: PHOTOGRAPHS OF TEST SETUP ..................................................................................................... 11 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20190800701E-02 Page: 4 of 11 3 General Information 3.1 Client Information Applicant: Zeos India Pvt. Ltd Address of Applicant: Plot No. 394, Road No. 81 Jubilee Hills, Hyderabad - 500033 Telan gana, India Manufacturer: Zeos India Pvt. Ltd Address of Manufacturer: Plot No. 394, Road No. 81 Jubilee Hills, Hyderabad - 500033 Telangana, India 3.2 General Description of EUT Product Name: ZEOS Smart Battery Module Model No.: ZMCSBM01 Brand Name: Zeos Hardware Version: V1.0 Software Version: V1.0 Equipment Category Non-ISM frequency Operation Frequency range 110-205KHz Modulation Type: Load Modulation Antenna Type: Loop Antenna Antenna Gain: 0dBi EUT Power Supply: DC5V 1A, DC9V 2A USB Cable:146cm(Shielded) Note: 1. In section 15.31(m), regards to the operating frequency range less 1 MHz. Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20190800701E-02 Page: 5 of 11 3.3 Test Environment Operating Environment: Temperature: 25 C Humidity:56 % RH Atmospheric Pressure: 992mbar Test Mode: Mode a: Wireless charging Mode at 5V (Full load) Mode b: Wireless charging Mode at 5V (half load) Mode c: Wireless charging Mode at 5V (Null load) 3.4 Description of Support Units The EUT has been tested with associated equipment below. 1)Support equipment DescriptionManufacturerModel No.Certification Supplied by AdapterXUNYUEAC001 FCCClient Wireless electronic Load -- -CQA Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20190800701E-02 Page: 6 of 11 3.5 Test Location Shenzhen Huaxia Testing Technology Co., Ltd, 1F., Block A of Tongsheng Technology Building…
Text truncated - open the document above for the full version.
FCC ID:2ASE9-ZMCSBM01 1 Photographs - EUT Test Setup 1.1 Radiated Emission 9KHz~30MHz: 30MHz~1GHz: FCC ID:2ASE9-ZMCSBM01 1.2 Conducted Emission
1F., Block A of Tongsheng Technology Building, · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |