FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Linklite Smart Lighting Co., Ltd/
  3. 2ASF2-R03MW

2ASF2-R03MW3M Neon Rope Light, Monitor Back Light-Wi-Fi Version

Shenzhen Linklite Smart Lighting Co., Ltd
3M Neon Rope Light, Monitor Back Light-Wi-Fi Version - FCC ID 2ASF2-R03MW - Shenzhen Linklite Smart Lighting Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 18, 2024
Application Purpose
Original Equipment
Date of Application
Mar 18, 2024
Equipment Note
3M Neon Rope Light, Monitor Back Light-Wi-Fi Version
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Linklite Smart Lighting Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

The device has been evaluated to meet general RF exposure requirement, This equipment should be installed and operated with a minumum distance of 20 cm between the radiator and your body. 302, Building 4, Rongcheng Scienti昀椀c Research Town, Xinfeng Road, Sunshine Community,Xili Street, Nanshan District, Shenzhen, Guangdong Province, China 3M Neon Rope Light

Users Manual

Rino Sma爀琀 App allows you to control and customize your controls for Monitor Back Light-Wi-Fi Version via your sma爀琀 device, Search for the latest version on Apple App sto re or Google Play. Monitor Back Light-Wi-Fi Version The device has been evaluated to meet general RF exposure requirement, This equipment should be installed and operated with a minumum distance of 20 cm between the radiator and your body. 302, Building 4, Rongcheng Scienti昀椀c Research Town, Xinfeng Road, Sunshine Community,Xili Street, Nanshan District, Shenzhen, Guangdong Province, China

Attestation Statements

Shenzhen Linklite Smart Lighting Co., Ltd 2024-03-05 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2ASF2-R03MW) [Shenzhen Linklite Smart Lighting Co., Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Richard Zhang General Manager Shenzhen Linklite Smart Lighting Co., Ltd 302, Building 4,Rongcheng Scientific Research Town, Xinfeng Road, Sunshine Community,Xili Street,Nanshan District, Shenzhen, Guangdong Province, China Shenzhen Linklite Smart Lighting Co., Ltd 2024-03-05 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for(FCC ID: 2ASF2-R03MW ) [Shenzhen Linklite Smart Lighting Co., Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Richard Zhang General Manager Shenzhen Linklite Smart Lighting Co., Ltd 302, Building 4,Rongcheng Scientific Research Town, Xinfeng Road, Sunshine Community,Xili Street,Nanshan District, Shenzhen, Guangdong Province, China

Cover Letter(s)

Shenzhen Linklite Smart Lighting Co., Ltd Declaration on model difference We the undersigned hereby confirm that these models are identical, and all models have the same RF module and antenna, PCB layout, schematics and component, except the adapter, LED light strip and colours are different. For more detailed information, please refer to the table below Production name Trademark FCC ID Model no. Model Difference 3M Neon Rope Light LINKLITE, EDUP IN 2ASF2-R03MW R03MW-3, EH-R03MW, EH-R03MW-S,EH-R03MW-P All models have the same RF module and antenna, PCB layout, schematics and component, except the model name and colours Monitor Back Light-Wi-Fi Version LINKLITE, EDUP IN 2ASF2-R03MW S03MB,S03MB-S,EH-S03MB, EH-S03MB-S,EH-S03MB-P All models have the same RF module and antenna, PCB layout, schematics and component, except the model name and colours Note: 3M Neon Rope Light and Monitor Back Light-Wi-Fi Version have the same RF module and antenna, PCB layout, schematics and component, except the adapter, LED light strip and colours are different. Sincerely, Richard Zhang General Manager Shenzhen Linklite Smart Lighting Co., Ltd 302, Building 4,Rongcheng Scientific Research Town, Xinfeng Road, Sunshine Community,Xili Street,Nanshan District, Shenzhen, Guangdong Province, China

External Photos

External Model: R03MW-3 Model: R03MW-3 Model: R03MW-3 Model: R03MW-3 Model: R03MW-3 Model: R03MW-3 Model: R03MW-3 Model: R03MW-3 Model: R03MW-3 Model: R03MW-3 Model: R03MW-3 Model: R03MW-3 Model: S03MB Model: S03MB Model: S03MB Model: S03MB Model: S03MB Model: S03MB Model: S03MB Model: S03MB Model: S03MB Model: S03MB Model: S03MB Model: S03MB

ID Label/Location Info

Model: R03MW-3 Input: AC100-240V DC24V⎓1.5A Power: 28W FCC ID: 2ASF2-R03MW 3M Neon Rope Light 60mm 25mm

ID Label/Location Info

Model: S03MB Input: AC100-240V DC24V⎓0.75A Power: 10W FCC ID: 2ASF2-R03MW Monitor Back Light-Wi-Fi Version 60mm 25mm

Internal Photos

Internal Model: R03MW-3 Model: S03MB Antenna

RF Exposure Info

RF EXPOSURE EVALUATION EUT Specification EUT 3M Neon Rope Light, Monitor Back Light - Wi-Fi Version Model R03MW-3, S03MB Series Model EH-R03MW, EH-R03MW-S, EH-R03MW-P, S03MB-S, EH-S03MB, EH-S03MB-S, EH-S03MB-P FCC ID 2ASF2-R03MW Antenna Gain 3.42dBi Operation Frequency 2412 MHz to 2462 MHz Modulation 802.11b: DSSS(DBPSK/DQPSK/CCK) 802.11g/n: OFDM(BPSK/QPSK/16QAM/64QAM) Input Rating AC100-240V 50/60Hz Max. output power IEEE 802.11b: 16.78 dBm IEEE 802.11g: 15.68 dBm IEEE 802.11n-HT20: 14.35 dBm IEEE 802.11n-HT40: 13.55 dBm Test Requirement: According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency(RF) Radiation as specified in §1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density(mW/cm 2 ) Average Time (A) Limits for Occupational/Control Exposures 300-1500 -- -- F/300 6 1500-100000 -- -- 5 6 (B) Limits for General Population/Uncontrol Exposures 300-1500 -- -- F/1500 6 1500-100000 -- -- 1 30 Friis transmission formula: Pd= (Pout*G)\ (4*pi*R 2 ) Where Pd= Power density in mW/cm 2 Pout=output power to antenna in mW G= Numeric gain of the antenna relative to isotropic antenna Pi=3.1416 R= distance between observation point and center of the radiator in cm=20cm Pd the limit of MPE, 1mW/cm 2 . If we know the maximum gain of the nd total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached. Measurement Result Antenna gain: 3.42dBi WIFI: Mode Channe l Freq. (MHz) Measured power (dBm) Tune-up power (dBm) Max tune-up power (dBm) Antenna Gain (Numeric) Evaluation result (mW/cm 2 ) Power density Limits (mW/cm 2 ) 802.11b 2412 16.78 17±1 18 2.198 0.027603 1 2437 16.56 17±1 18 2.198 0.027603 1 2462 16.26 16±1 17 2.198 0.021926 1 802.11g 2412 15.68 16±1 17 2.198 0.021926 1 2437 15.39 15±1 16 2.198 0.017416 1 2462 15.1 15±1 16 2.198 0.017416 1 802.11n HT20 2412 14.35 14±1 15 2.198 0.013834 1 2437 14.32 14±1 15 2.198 0.013834 1 2462 14.1 14±1 15 2.198 0.013834 1 802.11n HT40 2412 13.49 13±1 14 2.198 0.010989 1 2437 13.55 14±1 15 2.198 0.013834 1 2462 13.05 13±1 14 2.198 0.010989 1 Signature: Tiger Xu Date: 2023-03-12

Test Report

OTA TEST REPORT Applicant Espressif Systems Product ESP ANT B Model ESP ANT B Report No. Y1806A0621-T1V1 Issue Date December 21, 2018 TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in ANSI/IEEE Std 149-2008. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Performed by: Jiangpeng Lan Approved by: Kai Xu TA Technology (Shanghai) Co., Ltd. No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China TEL: +86‐021‐50791141/2/3 FAX: +86‐021‐50791141/2/3‐8000 OTA Test Report Report No: Y1806A0621-T1V1 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 2 of 15 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENTS 1. General Information ....................................................................................................................... 3 1.1. Notes of the Test Report ................................................................................................... 3 1.2. Test facility ........................................................................................................................ 3 1.3. Testing laboratory .............................................................................................................. 4 1.4. Laboratory Environment .................................................................................................... 4 2. General Description of Equipment under Test ............................................................................... 5 2.1. Applicant Information ......................................................................................................... 5 2.2. Manufacturer Information .................................................................................................. 5 2.3. Information of EUT ............................................................................................................ 5 2.4. Test Date ........................................................................................................................... 5 2.5. Applied Standards ............................................................................................................. 6 3. Test Conditions .............................................................................................................................. 7 3.1. Test Configuration ............................................................................................................. 7 3.2. Test Measurement ............................................................................................................. 7 4. Test Results ................................................................................................................................... 8 4.1. Gain and Efficiency ............................................................................................................ 8 4.2. Voltage Standing Wave Ratio (VSWR) .............................................................................. 9 4.3. Antenna S11 .................................................................................................................... 10 5. Test Equipment List ..................................................................................................................... 11 APPENDIX A: 2-D Pattern Plots ............................................................................................................. 12 APPENDIX B: The EUT Appearance and Test Configuration .................................................................. 14 B.1 EUT Appearance ................................................................................................................... 14 B.2 Test Configuration ................................................................................................................. 15 OTA Test Report Report No: Y1806A0621-T1V1 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 3 of 15 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1. General Information 1.1. Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA technology (shanghai) co., Ltd.The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein .Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. This report must not be used by the client to claim product certification, approval, or endorsement by any government agencies. 1.2. Test facility CNAS (accreditation number:L2264) TA Technology (Shanghai) Co., Ltd. has obtained the accreditation of China National Accreditation Service for Conformity Assessment (CNAS). FCC (Designation number: CN1179, Test Firm Registration Number: 446626) TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. IC (recognition number is 8510A) TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic emission measurement. A2LA (Certificate Number: 3857.01) TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory Accreditation to perform electromagnetic emission measurement. OTA Test Report Report No: Y1806A0621-T1V1 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 4 of 15 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1.3. Testing laboratory Company: TA Technology (Shanghai) Co., Ltd. Address: No.145, Jintang Rd, Tangzhen Industry Park, Pudong Ci…

Text truncated - open the document above for the full version.

Test Report

1 / 73 Appendix A Duty Cycle Condition Mode Frequency (MHz) Antenna Duty Cycle (%) Correction Factor (dB) 1/T (kHz) NVNT b 2412 Ant1 89.84 0.47 0.99 NVNT b 2437 Ant1 90.02 0.46 0.99 NVNT b 2462 Ant1 89.84 0.47 0.99 NVNT g 2412 Ant1 90.09 0.45 1.62 NVNT g 2437 Ant1 90.09 0.45 1.62 NVNT g 2462 Ant1 90.09 0.45 1.62 NVNT n20 2412 Ant1 89.74 0.47 1.63 NVNT n20 2437 Ant1 90.03 0.46 1.63 NVNT n20 2462 Ant1 90.03 0.46 1.63 NVNT n40 2422 Ant1 90.03 0.46 1.63 NVNT n40 2437 Ant1 89.74 0.47 1.63 NVNT n40 2452 Ant1 90.03 0.46 1.63 2 / 73 Test Graphs Duty Cycle NVNT b 2412MHz Ant1 Duty Cycle NVNT b 2437MHz Ant1 3 / 73 Duty Cycle NVNT b 2462MHz Ant1 Duty Cycle NVNT g 2412MHz Ant1 4 / 73 Duty Cycle NVNT g 2437MHz Ant1 Duty Cycle NVNT g 2462MHz Ant1 5 / 73 Duty Cycle NVNT n20 2412MHz Ant1 Duty Cycle NVNT n20 2437MHz Ant1 6 / 73 Duty Cycle NVNT n20 2462MHz Ant1 Duty Cycle NVNT n40 2422MHz Ant1 7 / 73 Duty Cycle NVNT n40 2437MHz Ant1 Duty Cycle NVNT n40 2452MHz Ant1 8 / 73 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Duty Factor (dB) Total Power (dBm) Limit (dBm) Verdict NVNT b 2412 Ant1 16.78 0 16.78 30 Pass NVNT b 2437 Ant1 16.56 0 16.56 30 Pass NVNT b 2462 Ant1 16.26 0 16.26 30 Pass NVNT g 2412 Ant1 15.68 0 15.68 30 Pass NVNT g 2437 Ant1 15.39 0 15.39 30 Pass NVNT g 2462 Ant1 15.1 0 15.1 30 Pass NVNT n20 2412 Ant1 14.35 0 14.35 30 Pass NVNT n20 2437 Ant1 14.32 0 14.32 30 Pass NVNT n20 2462 Ant1 14.1 0 14.1 30 Pass NVNT n40 2422 Ant1 13.49 0 13.49 30 Pass NVNT n40 2437 Ant1 13.55 0 13.55 30 Pass NVNT n40 2452 Ant1 13.05 0 13.05 30 Pass 9 / 73 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT b 2412 Ant1 9.09 0.5 Pass NVNT b 2437 Ant1 9.56 0.5 Pass NVNT b 2462 Ant1 9.55 0.5 Pass NVNT g 2412 Ant1 16.32 0.5 Pass NVNT g 2437 Ant1 16.35 0.5 Pass NVNT g 2462 Ant1 16.35 0.5 Pass NVNT n20 2412 Ant1 17.57 0.5 Pass NVNT n20 2437 Ant1 17.57 0.5 Pass NVNT n20 2462 Ant1 17.58 0.5 Pass NVNT n40 2422 Ant1 36.34 0.5 Pass NVNT n40 2437 Ant1 36.33 0.5 Pass NVNT n40 2452 Ant1 36.33 0.5 Pass 10 / 73 Test Graphs -6dB Bandwidth NVNT b 2412MHz Ant1 -6dB Bandwidth NVNT b 2437MHz Ant1 11 / 73 -6dB Bandwidth NVNT b 2462MHz Ant1 -6dB Bandwidth NVNT g 2412MHz Ant1 12 / 73 -6dB Bandwidth NVNT g 2437MHz Ant1 -6dB Bandwidth NVNT g 2462MHz Ant1 13 / 73 -6dB Bandwidth NVNT n20 2412MHz Ant1 -6dB Bandwidth NVNT n20 2437MHz Ant1 14 / 73 -6dB Bandwidth NVNT n20 2462MHz Ant1 -6dB Bandwidth NVNT n40 2422MHz Ant1 15 / 73 -6dB Bandwidth NVNT n40 2437MHz Ant1 -6dB Bandwidth NVNT n40 2452MHz Ant1 16 / 73 Occupied Channel Bandwidth Condition Mode Frequency (MHz) Antenna 99% OBW (MHz) NVNT b 2412 Ant1 13.169 NVNT b 2437 Ant1 13.148 NVNT b 2462 Ant1 13.15 NVNT g 2412 Ant1 16.752 NVNT g 2437 Ant1 16.719 NVNT g 2462 Ant1 16.745 NVNT n20 2412 Ant1 17.896 NVNT n20 2437 Ant1 17.88 NVNT n20 2462 Ant1 17.905 NVNT n40 2422 Ant1 36.694 NVNT n40 2437 Ant1 36.677 NVNT n40 2452 Ant1 36.706 17 / 73 Test Graphs OBW NVNT b 2412MHz Ant1 OBW NVNT b 2437MHz Ant1 18 / 73 OBW NVNT b 2462MHz Ant1 OBW NVNT g 2412MHz Ant1 19 / 73 OBW NVNT g 2437MHz Ant1 OBW NVNT g 2462MHz Ant1 20 / 73 OBW NVNT n20 2412MHz Ant1 OBW NVNT n20 2437MHz Ant1 21 / 73 OBW NVNT n20 2462MHz Ant1 OBW NVNT n40 2422MHz Ant1 22 / 73 OBW NVNT n40 2437MHz Ant1 OBW NVNT n40 2452MHz Ant1 23 / 73 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/3kHz) Duty Factor (dB) Total PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT b 2412 Ant1 -9.02 0 -9.02 8 Pass NVNT b 2437 Ant1 -11.19 0 -11.19 8 Pass NVNT b 2462 Ant1 -11.01 0 -11.01 8 Pass NVNT g 2412 Ant1 -13.83 0 -13.83 8 Pass NVNT g 2437 Ant1 -13.82 0 -13.82 8 Pass NVNT g 2462 Ant1 -14.51 0 -14.51 8 Pass NVNT n20 2412 Ant1 -13.11 0 -13.11 8 Pass NVNT n20 2437 Ant1 -13.2 0 -13.2 8 Pass NVNT n20 2462 Ant1 -13.83 0 -13.83 8 Pass NVNT n40 2422 Ant1 -13.32 0 -13.32 8 Pass NVNT n40 2437 Ant1 -13.92 0 -13.92 8 Pass NVNT n40 2452 Ant1 -13.9 0 -13.9 8 Pass 24 / 73 Test Graphs PSD NVNT b 2412MHz Ant1 PSD NVNT b 2437MHz Ant1 25 / 73 PSD NVNT b 2462MHz Ant1 PSD NVNT g 2412MHz Ant1 26 / 73 PSD NVNT g 2437MHz Ant1 PSD NVNT g 2462MHz Ant1 27 / 73 PSD NVNT n20 2412MHz Ant1 PSD NVNT n20 2437MHz Ant1 28 / 73 PSD NVNT n20 2462MHz Ant1 PSD NVNT n40 2422MHz Ant1 29 / 73 PSD NVNT n40 2437MHz Ant1 PSD NVNT n40 2452MHz Ant1 30 / 73 Band Edge Condition Mode Frequency (MHz) Antenna Max Value (dBc) Limit (dBc) Verdict NVNT b 2412 Ant1 -48.752 -20 Pass NVNT b 2462 Ant1 -53.907 -20 Pass NVNT g 2412 Ant1 -35.405 -20 Pass NVNT g 2462 Ant1 -46.446 -20 Pass NVNT n20 2412 Ant1 -33.074 -20 Pass NVNT n20 2462 Ant1 -42.597 -20 Pass NVNT n40 2422 Ant1 -25.522 -20 Pass NVNT n40 2452 Ant1 -39.931 -20 Pass 31 / 73 Test Graphs Band Edge NVNT b 2412MHz Ant1 Ref Band Edge NVNT b 2412MHz Ant1 Emission 32 / 73 Band Edge NVNT b 2462MHz Ant1 Ref Band Edge NVNT b 2462MHz Ant1 Emission 33 / 73 Band Edge NVNT g 2412MHz Ant1 Ref Band Edge NVNT g 2412MHz Ant1 Emission 34 / 73 Band Edge NVNT g 2462MHz Ant1 Ref Band Edge NVNT g 2462MHz Ant1 Emission 35 / 73 Band Edge NVNT n20 2412MHz Ant1 Ref Band Edge NVNT n20 2412MHz Ant1 Emission 36 / 73 Band Edge NVNT n20 2462MHz Ant1 Ref Band Edge NVNT n20 2462MHz Ant1 Emission 37 / 73 Band Edge NVNT n40 2422MHz Ant1 Ref Band Edge NVNT n40 2422MHz Ant1 Emission 38 / 73 Band Edge NVNT n40 2452MHz Ant1 Ref Band Edge NVNT n40 2452MHz Ant1 Emission 39 / 73 Conducted RF Spurious Emission Condition Mode Frequency (MHz) Antenna Max Value (dBc) Limit (dBc) Verdict NVNT b 2412 Ant1 -44.02 -20 Pass NVNT b 2437 Ant1 -42.53 -20 Pass NVNT b 2462 Ant1 -41.7 -20 Pass NVNT g 2412 Ant1 -35.64 -20 Pass NVNT g 2437 Ant1 -35.48 -20 Pass NVNT g 2462 Ant1 -33.62 -20 Pass NVNT n20 2412 Ant1 -33.55 -20 Pass NVNT n20 2437 Ant1 -35.14 -20 Pass NVNT n20 2462 Ant1 -34.69 -20 Pass NVNT n40 2422 Ant1 -30.4 -20 Pass NVNT n40 2437 Ant1 -28.29 -20 Pass NVNT n40 2452 Ant1 -29.84 -20 Pass 40 / 73 Test Graphs Tx. Spurious NVNT b 2412MHz Ant1 Ref Tx. Spurious N…

Text truncated - open the document above for the full version.

Test Report

TRF No.: 01-E001-1A TRF Originator: GTG TRF Date: 2022-07-01 Web: www.gtggroup.com E-mail: [email protected] Tel.: 86-400 755 8988 CFR 47 FCC PART 15 SUBPART C(DTS) TEST REPORT For 3M Neon Rope Light, Monitor Back Light - Wi-Fi Version MODEL NUMBER: R03MW-3, EH-R03MW, EH-R03MW-S, EH-R03MW-P, S03MB, S03MB-S, EH-S03MB, EH-S03MB-S, EH-S03MB-P REPORT NUMBER: E01A24010761F00101 ISSUE DATE: March 12, 2024 FCC ID: 2ASF2-R03MW Prepared for Shenzhen Linklite Smart Lighting Co., Ltd 302, Building 4, Rongcheng Scientific Research Town, Xinfeng Road, Sunshine Community,Xili Street, Nanshan District, Shenzhen, Guangdong Province, China Prepared by Guangdong GTG Testing Technology Co., Ltd. 1-2/F., Building A, and 1/F., Building B, No. 11, Zongbu 2nd Road, Songshan Lake High-Tech Industrial Development Zone, Dongguan, Guangdong, China This report shall not be reproduced, except in full, without the written approval of Guangdong GTG Testing Technology Co., Ltd. REPORT NO.: E01A24010761F00101 Page 2 of 47 TRF No.: 01-E001-1A Global Testing , Great Quality. Revision History Rev. Issue Date Revisions Revised By V0 March 13, 2024 Initial Issue REPORT NO.: E01A24010761F00101 Page 3 of 47 TRF No.: 01-E001-1A Global Testing , Great Quality. Summary of Test Results Test Item Clause Limit/Requirement Result Antenna Requirement N/A FCC Part 15.203/15.247 (c) Pass AC Power Line Conducted Emission ANSI C63.10-2013, Clause 6.2 FCC Part 15.207 Pass Conducted Output Power ANSI C63.10-2013, Clause 11.9.1.3 FCC Part 15.247 (b)(3) Pass 6dB Bandwidth and 99% Occupied Bandwidth ANSI C63.10-2013, Clause 11.8.1 FCC Part 15.247 (a)(2) Pass Power Spectral Density ANSI C63.10-2013, Clause 11.10.2 FCC Part 15.247 (e) Pass Conducted Band edge and spurious emission ANSI C63.10-2013, Clause 11.11 FCC Part 15.247(d) Pass Radiated Band edge and Spurious Emission ANSI C63.10-2013, Clause 11.11 & Clause 11.12 FCC Part 15.205/15.209 Pass Duty Cycle ANSI C63.10-2013, Clause 11.6 None; for reporting purposes only. Pass *This test report is only published to and used by the applicant, and it is not for evidence purpose in China. *The measurement result for the sample received is <Pass> according to <CFR 47 FCC PART 15 SUBPART C(DTS)> when <Accuracy Method> decision rule is applied. REPORT NO.: E01A24010761F00101 Page 4 of 47 TRF No.: 01-E001-1A Global Testing , Great Quality. CONTENTS 1. ATTESTATION OF TEST RESULTS ..................................................................................... 5 2. TEST METHODOLOGY ......................................................................................................... 6 3. FACILITIES AND ACCREDITATION ..................................................................................... 6 4. CALIBRATION AND UNCERTAINTY ................................................................................... 7 4.1. MEASURING INSTRUMENT CALIBRATION ........................................................... 7 4.2. MEASUREMENT UNCERTAINTY ............................................................................ 7 5. EQUIPMENT UNDER TEST .................................................................................................. 8 5.1. DESCRIPTION OF EUT ........................................................................................... 8 5.2. CHANNEL LIST ........................................................................................................ 8 5.3. MAXIMUM Peak EIRP .............................................................................................. 9 5.4. TEST CHANNEL CONFIGURATION ........................................................................ 9 5.5. THE WORSE CASE POWER SETTING PARAMETER ............................................ 9 5.6. DESCRIPTION OF AVAILABLE ANTENNAS ......................................................... 10 5.7. SUPPORT UNITS FOR SYSTEM TEST ................................................................. 10 5.8. SETUP DIAGRAM .................................................................................................. 11 6. MEASURING EQUIPMENT AND SOFTWARE USED......................................................... 12 7. ANTENNA PORT TEST RESULTS ..................................................................................... 14 7.1. Conducted Output Power ........................................................................................ 14 7.2. 6dB Bandwidth ........................................................................................................ 15 7.3. Power Spectral Density ........................................................................................... 17 7.4. Conducted Band edge and spurious emission ........................................................ 18 7.5. Duty Cycle .............................................................................................................. 20 8. RADIATED TEST RESULTS ............................................................................................... 21 9. ANTENNA REQUIREMENT ................................................................................................ 26 10. AC POWER LINE CONDUCTED EMISSION ......................................................... 27 11. TEST DATA ............................................................................................................ 29 12. PHOTOGRAPHS OF TEST CONFIGURATION ..................................................... 30 13. PHOTOGRAPHS OF THE EUT .............................................................................. 33 REPORT NO.: E01A24010761F00101 Page 5 of 47 TRF No.: 01-E001-1A Global Testing , Great Quality. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: Shenzhen Linklite Smart Lighting Co., Ltd Address: 302, Building 4, Rongcheng Scientific Research Town, Xinfeng Road, Sunshine Community,Xili Street, Nanshan District, Shenzhen, Guangdong Province, China Manufacturer Information Company Name: Shenzhen Linkl…

Text truncated - open the document above for the full version.

Test Setup Photos

AC Power Line Conducted Emission Model: R03MW-3 Model: S03MB Radiated Band edge and Spurious Emission Model: R03MW-3 Model: S03MB Model: R03MW-3

Contact Information

Applicant

Richard Zhang(General Manager)
[email protected]+86 15190289533Fax: NA

Test Firm

Guangdong GTG Testing Technology Co., Ltd.Kingbo Hu
[email protected]86-769- 8507 5888

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz47.60 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The device supports 20MHz and 40MHz bandwidths. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.

Other Applications from Shenzhen Linklite Smart Lighting Co., Ltd

Smart table device - FCC ID 2ASF2-KTA03E - Shenzhen Linklite Smart Lighting Co., Ltd
2ASF2-KTA03E

Smart table device

Sep 15, 2020

Equipment Class

DTS - Digital Transmission System